1. 2 x Dowty washer 3 4 BSP 1 x Dowty washer 3 8 BSP Issue 0 TIL Eng Spec 069 Page 15 of 24 Tritech International Ltd ZipJet Ultra OM The procedure to fit a Tritech AMI Volvo Protector is as follows Remove any existing port fittings from the F11 10 Volvo motor Ensure that the top face of the F11 10 Volvo motor is free from any debris i e paint dirt and grit etc Clean and degrease surface Insert the three protector O rings into the grooves of the protector as shown in Picture 1 Picture 1 Place the protector onto the motor with the grooved face facing down Ensure the O rings remain in their groove during this process Place the dowty washers over the protector and screw in the fittings as shown in Picture 2 Picture 2 Issue 0 TIL Eng Spec 069 Page 16 of 24 Tritech International Ltd ZipJet Ultra OM Once the fittings have been inserted and tightened blanking caps should then be fitted The motor assembly is fitted to the Zip Jet Ultra as shown in Picture 3 Picture 3 Safety Note Never use the same size fitting for pressure hoses and the case drain If this is done there is a significant risk of incorrect hook up causing pressure to be applied to the motor case which could cause the case to Danger burst explosively with high risk of personal injury Required hydraulic flow For the Volvo F11 10 motor The vehicle hydraulic system should be
2. been developed from the highly successful Zip Pump and ZipJet range of products The integrated eductor based excavation system is designed to pump mud sand gravel drill cuttings shale etc without risk of blockage A heavy duty cylinder reverses the flow at the nozzle to eject any object which may be causing an obstruction A second cylinder operates a diverter valve to provide a powertul direct jet to break up heavy and cohesive seabed mud and sand prior to excavation PRINCIPLES OF OPERATION Suction Operation The ZipJet Ultra pump is based on the principles of the annular eductor pump It has a monoblock configuration in which the eductor pump and power pump are contained within a common body The power for the eductor section of the pump is provided by a stream of clean water driven by the centrifugal impeller section Clean water is drawn into the inlet passes through the impeller of the power pump and is then injected into the main suction stream via the annular eductor nozzle SS ae Afh IY 3 cman 077 i zer Issue 0 TIL Eng Spec 069 Page 9 of 24 Tritech International Ltd ZipJet Ultra OM The main suction stream can convey heavy contamination of sand mud gravel and drilling debris The pump has a retro flush valve just behind the eductor When this is closed operating cylinder extended the power fluid is then directed to the suction nozzle This feature can be used to clear blocked
3. shaft right up to the shoulder Assemble the retainer onto the shaft end and secure the setscrew using a small quantity of Loctite Replace the impeller on the boss and secure the four countersunk screws with Loctite Retro flush core Check that the core is a loose fit in the valve body and that the dirt relief grooves are clear Push the core into the body and refit to the case using the 4 long countersunk screws to locate the valve core in the body Tighten the four screws carefully to about 10 ft lbs torque in a diagonal pattern Check that the valve core continues to turn freely If the bolts are over tightened the valve core will start to bind Issue 0 TIL Eng Spec 069 Page 22 of 24 Tritech International Ltd ZipJet Ultra OM Divertor valve Vane Line up the vane with the operating shaft and replace the two setcrews using a small amount of Loctite Divertor vane adjustment The divertor valve actuator arm will require adjustment to ensure the vane lies correctly when set in either mode of operation Fit the rod end of the actuator to the operating shaft and leave the cylinder end free from the mounting nut Close the actuator fully and place the vane in the suction direction Fully clockwise when viewed from the motor side Adjust the cylinder end bearing to align with the actuator mounting nut Lock the setting using the locknut and a small amount of Loctite Issue 0 TIL Eng Spec 069 Page
4. 23 of 24 Tritech International Ltd Parts List OONOO BW ND DEL TRI ZJU 89 01 DEL TRI ZJU 89 02 DEL TRI ZJU 89 03 DEL TRI ZJU 89 04 DEL TRI ZJU 89 05 DEL TRI ZJU 89 06 DEL TRI ZJU 89 07 DEL TRI ZJU 89 08 DEL TRI ZJU 89 09 DEL TRI ZJU 89 10 DEL TRI ZJU 89 11 DEL TRI ZJU 89 12 DEL TRI ZJU 89 14 DEL TRI ZJU 89 15 DEL TRI ZJU 89 16 DEL TRI ZJU 89 17 TI SZJU 10 90 0 RSE or D16 90 TI SZJU 10 27 0 RSE or D16 27 Issue 0 ZipJet Ultra OM Motor Volvo F11 010 MB CHK 000 c w Speedi Sleeve DEF11 10MBCHK 99098 Retro valve body Pump case retro valve side Pump case motor side Clean water inlet body Retro valve core Impeller Impeller boss Impeller retainer Suction inlet body Pressure jet outlet Diverter blade Diverter valve actuator arm Motor mounting disc Retro valve actuator arm Actuator mounting nut Retro valve actuator cylinder Diverter valve actuator cylinder TIL Eng Spec 069 Page 24 of 24
5. Tritech S International Limited ZipJet ULTRA Operators Manual The electronic version of this document is the controlled copy Therefore all printed versions of this document are uncontrolled Issue 0 TIL Eng Spec 069 ZipJet Ultra Operator Manual COPYRIGHT Tritech International Limited The copyright in this document is the property of Tritech International Limited The document is supplied by Tritech International Limited on the understanding that it may not be copied used or disclosed to others except as authorised in writing by Tritech International Limited Tritech International Limited reserves the right to change modify and update designs and specifications as part of their ongoing product development programme F063 1 Tritech International Ltd CONTENTS WARRANTY POLICY SAFETY STATEMENTS amp CE MARKING TECHNICAL SUPPORT INTRODUCTION PRINCIPLES OF OPERATION Suction Operation Jetting Operation INSTALLATION Mechanical Installation Water Hose Installation Hoses Fittings Clean Suction intake screen Dredge Suction Nozzle Jet Nozzle Hydraulic Installation Hydraulic oil Filtration Hydraulic Hook up Tritech Volvo Protector Retro fitting the Volvo Protector Safety Note Required hydraulic flow Testing In Air Hydraulic motor shaft seals Issue 0 TIL Eng Spec 069 ZipJet Ultra OM Page 4 of 24 14 15 15 17 18 18 Trit
6. ading the motor when the supply is stopped it is essential to provide the check valve shown This will allow the motor to run down steadily rather than coming to an abrupt stop Issue 0 TIL Eng Spec 069 Page 14 of 24 Tritech International Ltd ZipJet Ultra OM Specification for check valve 1 2 check valve cracking pressure 0 5 bar Recommended valve Integrated Hydraulics FPR 1 22 0 5 Hydraulic fittings The following fittings are supplied as standard Motor A amp B ports No 12 JIC male Motor case drain No 6JlC male If it is desired to change these for any reason then the motor port threads are Motor A amp B ports 3 4 BSP parallel Motor case drain 3 8 BSP parallel Tritech Volvo Protector The Zip Jet Ultra pumps serial numbered ZJU89025 onwards are factory fitted with the Tritech Volvo Protector This removes the necessity to fit an external check valve as described above To establish whether a Volvo Protector is fitted to the pump examine the Volvo motor hydraulic ports and compare with picture 3 The Volvo Protector is clearly identifiable and will be stamped with the serial number AMI VP XXX Note The BSP Volvo ports are no longer available with the Tritech Volvo Protector fitted Retro fitting the Volvo Protector A Volvo Protector kit comprises 1 x VVF 001 Check valve body 2 x VVF 002 JIC 12 fittings 1 x VVF 003 JIC 6 fitting 2 x O ring No 024 1 x O ring No 017
7. aulic Installation Hydraulic oil The pump should be operated using a premium grade mineral based hydraulic oil of ISO VG 22 to 32 Filtration The hydraulic system filtration must be to a minimum of 10um absolute standard A 10um nominal standard is regarded as inadequate The recommended filtration is UN elements produced by Pall Industrial Hydraulics Ltd or equivalent products Hydraulic Hook up RETURN B PRESSURE A The pump is configured for correct rotation when the hydraulic supply is connected to the A port of the Volvo motor and the return line to the B port It is mandatory that the drain connection from the motor back to tank is a minimum of 3 8 bore The drain line should return straight to tank without restriction It is permissible to connect the drain line back into a larger bore drain manifold which has been correctly sized to accommodate all drains attached to it It is not permissible to common up the drain line with return flow lines used on the drain line Use of such fittings is at the users risk If sucha connection is used then it is mandatory to ensure that it has been fully and correctly fitted prior to starting the motor Failure to do so may result in pressurisation of the motor casing which could explosively burst under system hydraulic pressure with considerable risk of personal injury It is strongly recommended that self sealing quick disconnects are not A Danger To avoid shock lo
8. ay be removed and replaced with longer bolts to provide supplementary mounts It is recommended that the pump be supported along its lower edge and a bracket used to secure it to the main 16mm diameter mounting point The pump should not be mounted using the motor or hose nozzles as attachment points Water Hose Installation Hoses Clean water inlet hose 100mm ID Dredge suction hose 75mm ID Discharge hose 100mm ID Recommended hose type Kanaline AW Hydrasun Arizona Kanaline AW has plastic reinforcement and a semi transparent wall which assists visual inspection for damage and blockages Being all plastic it is light in water Alternative makes of suction and discharge hose may be used provided that they have a smooth internal bore Issue 0 TIL Eng Spec 069 Page 11 of 24 Tritech International Ltd ZipJet Ultra OM If the above hose types are unavailable then the hose can be any crush resistant PVC coil strengthened hose Layflat style hoses are not recommended for discharge Fittings Use standard Kanaline fittings or heavy duty worm drive clips Use of heavy duty two bolt clamps will result in damage to the hose connections on the pump unit Jet hose 25mm ID Recommended hose type Kanaline AW Hydrasun Arizona Clean Suction intake screen It is recommended that a Tritech supplied suction strainer be used with the pump If the user supplies his own strainer then it must meet t
9. capable of supplying a minimum 50I min at 195 bar to the motor ports Less than this will adversely affect performance The maximum permissible flow is 65l min at 240bar Achieving these flows in an unloaded condition is no guarantee that the supply can actually be met in the working condition It is recommended that the installation be checked using a hydraulic flowmeter equipped with a loading valve which can simulate the motor running under load In order to avoid pressure losses it is mandatory that a minimum of 1 2 bore pipework or hoses is used on the flow and return lines to the motor 3 4 or larger is recommended Issue 0 TIL Eng Spec 069 Page 17 of 24 Tritech International Ltd ZipJet Ultra OM Testing In Air Under no circumstances must the flow be allowed to exceed 70I mi when testing in air There is no back pressure on the impeller to control its speed and many vehicle hydraulic systems are capable of higher deliveries when there are no thrusters running Over speeding the Caution motor can cause catastrophic failure To avoid excessive wear and the possibility of ceasing the impeller and body the unit should not be run for extended periods out of the water More than 30 seconds This is especially true when the unit is new Absence of water around the plastic removes the natural cooling mechanism and may result in the moving parts becoming misshapen due to heat Retro flush valve and diverter act
10. e majority of leading edges are eroded more than 3 5mm back from the bore of the inlet nozzle then consideration should be given to replacing the impeller Basic fault finding Poor performance Check that the clean water suction strainer is clear and that there are no blockages in the hose Check that the retro flush valve is opening fully Check that the suction hose reinforcement is intact and that there is no sign of the hose collapsing under suction Check that the discharge hose is not damaged or kinked Remove the clean water suction hose from the pump and check that the face of the impeller is not obstructed by material like rope fibre or shreds of plastic bags Check that the hydraulic motor runs freely without excessive noise or vibration Check that the hydraulic flow meets the specification Issue 0 TIL Eng Spec 069 Page 20 of 24 Tritech International Ltd ZipJet Ultra OM Dismantling Tools and materials The following tools are required to work on the pump 19mm open ended spanner 19mm socket short extension bar and ratchet 10mm open ended spanner 10mm Allen key 4mm Allen key Dead blow hammer 3 jaw puller Loctite Studlock for reassembly Removal of hydraulic motor and power pump impeller Disconnect all hydraulic hoses from the motor and fit caps to the ports Remove the 6 bolts holding the motor mounting plate to the pump this will include removing an actuator mounting post Remove the m
11. ech International Ltd MAINTENANCE Basic maintenance procedures Pre Dive Storage Basic fault finding Dismantling Removal of hydraulic motor and power pump impeller Removal of the retro flush valve Removal of the diverter valve vane Reassembly Hydraulic Motor and Impeller Retro flush core Divertor valve Vane Parts List Issue 0 TIL Eng Spec 069 ZipJet Ultra OM Page 5 of 24 Tritech International Ltd ZipJet Ultra OM WARRANTY POLICY Tritech International Limited herein after referred to as TIL TIL warrants that at the time of shipment all products shall be free from defects in material and workmanship and suitable for the purpose specified in the product literature The unit system warranty commences immediately from the date of customer acceptance and runs for a period of 365 days Customer acceptance will always be deemed to have occurred within 72 hours of delivery Note Any customer acceptance testing if applicable must be performed at either TIL premises or at one of their approved distributors unless mutually agreed in writing prior to despatch Conditions These include but are not limited to the following The warranty is only deemed to be valid if the equipment was sold through TIL or one of its approved distributors The equipment must have been installed and commissioned in strict accordance with approved technical standards and specifications and for the purpose that the system was d
12. esigned The warranty is not transferable except or as applies to Purchaser first then to client TIL must be notified immediately in writing of any suspected defect and if advised by TIL the equipment subject to the defect shall be returned by the customer to TIL via a suitable mode of transportation and shall be freight paid The warranty does not apply to defects that have been caused by failure to follow the recommended installation or maintenance procedures Or defects resulting from normal wear amp tear incorrect operation fire water ingress lightning damage or fluctuations in vehicles supply voltages or from any other circumstances that may arise after delivery that is out with the control of TIL Note The warranty does not apply in the event where a defect has been caused by isolation incompatibilities The warranty does not cover the transportation of personnel and per diem allowances relating to any repair or replacement The warranty does not cover any direct indirect punitive special consequential damages or any damages whatsoever arising out of or connected with misuse of this product Any equipment or parts returned under warranty provisions will be returned to the customer freight prepaid by TIL The warranty shall become invalid if the customer attempts to repair or modify the equipment without appropriate written authority being first received from TIL TIL retains the sole right to accept or reject any warra
13. he following specifications Mesh types Both rectangular and circular aperture suction screens may be used Square mesh max 4mm aperture Circular perforations max 6mm dia Total free flow area min 0 016m The pump should not be operated in any circumstances without a suction screen meeting the above specification Dredge Suction Nozzle If the user wishes to make up special nozzles the following specification should be met to optimise performance Suction nozzles should be designed with a nozzle cross section area of 3800mm Smaller nozzles may be used for special tasks but material removal rates will be reduced Larger nozzles are of no benefit and will reduce performance A nozzle guard should be fitted that will pass a maximum of a 40mm dia sphere or 35mm sided cube The pump can pass single objects of a larger size but if the pump takes in a stream of objects of larger size than blockages can occur by bridging Issue 0 TIL Eng Spec 069 Page 12 of 24 Tritech International Ltd ZipJet Ultra OM Jet Nozzle The user may make up jet nozzles as required The recommended size are 14 19 mm diameter or an equivalent area The optimum size will need to be determined by trial because the water output from the power pump will vary depending on the oil pressure and flow available from the ROV s hydraulic system Issue 0 TIL Eng Spec 069 Page 13 of 24 Tritech International Ltd ZipJet Ultra OM Hydr
14. nts that could lead to injury or loss of life will be highlighted Danger to the operator by indications in the margin identified as opposite Throughout the manual certain safety related comments and requirements that could result in damage to the product or other Caution property will be highlighted to the operator by indications in the margin identified as opposite Issue 0 TIL Eng Spec 069 Page 7 of 24 Tritech International Ltd ZipJet Ultra OM TECHNICAL SUPPORT Contact your local agent or Tritech International Ltd Tritech International Lid Peregrine Road Wesithill Business Park Westhill Aberdeen AB32 6JL UK Telephone 44 0 1224 744111 Fax 44 0 1224 741771 Email support tritech co uk Web www tritech co uk An out of hours emergency number is available by calling the above telephone number If you have cause to use our Technical Support service please ensure that you have the following details at hand prior to calling System Serial Number if applicable Fault Description Any remedial action implemented Software Revision if applicable Due to the expansion of equipment capabilities and the fact that new sub modules are continually being introduced this manual cannot detail every aspect of the operation Issue 0 TIL Eng Spec 069 Page 8 of 24 Tritech International Ltd ZipJet Ultra OM INTRODUCTION The new ZipJet ULTRA has
15. nty claim Each product is carefully examined and checked before it is shipped It should therefore be visually and operationally checked as soon as it is received If it is damaged in anyway a claim should be filed with the courier and TIL notified of the damage Note TIL reserve the right to change specifications at any time without notice and without any obligation to incorporate new features in instruments previously sold Note If the instrument is not covered by warranty or if it is determined that the fault is caused by misuse repair will be billed to the customer and an estimate submitted for customer approval before the commencement of repairs Issue 0 TIL Eng Spec 069 Page 6 of 24 Tritech International Ltd ZipJet Ultra OM SAFETY STATEMENTS amp CE MARKING The installation of the pump is fully the responsibility of the user It is powered by high pressure hydraulics and contains moving parts Full consideration has been given to the requirements for CE marking and the relevant safety information is contained within this manual Since the pump as supplied as a subsystem and its safe use is installation specific actual compliance is the responsibility of the installer It must be operated in accordance with the following instruction manual Failure to follow the recommendations of this manual may lead to safety hazards or equipment failure Throughout the manual certain safety related comments and requireme
16. ounting plate motor impeller assembly Remove the four countersunk setscrews securing the impeller to the boss these will be tight since they are retained by Loctite Remove the impeller Remove the retaining setscrew and endcap from the end of the motor shaft Using a suitable 3 jaw puller remove the impeller boss from the motor shaft Removal of the retro flush valve This requires splitting the pump casing Disconnect all hoses and remove the pump from the vehicle Remove the motor as above Remove the 7 remaining case bolts and separate the casing Issue 0 TIL Eng Spec 069 Page 21 of 24 Tritech International Ltd ZipJet Ultra OM Remove the actuator from the valve core arm Unscrew the four long countersunk screws securing the valve body to the pump and then pull off the valve body The valve core is located by the four long screws so it is now free to be withdrawn from the valve body Removal of the diverter valve vane This also requires splitting the pump case Proceed as above as far as separating the case sections Access is now available to remove the two setscrews retaining the vane onto its operating shaft Remove these two screws and lift out the vane blade Reassembly Reassembly is the reverse of the procedures above but with particular attention to the following Hydraulic Motor and Impeller Apply some anti seize grease to the motor shaft before fitting the impeller Press the impeller boss onto the
17. suction nozzle or to complete a deburial operation by blowing away the last sand and mud from around an object The optimum performance will be obtained with the nozzle pushed deep into the debris and agitated gently Where a great deal of debris is encountered it will be necessary to keep withdrawing the nozzle Jetting Operation The body of the pump contains a diverter vane The purpose of the vane is to switch the flow of the power pump water between the suction eductor and the jetting outlet The diverter should be operated fully in one direction or the other attempting to share the flow between the eductor and the jet nozzle by using a mid position will result in effectual performance from both The diverter is set for suction when the cylinder is retracted and for jetting with the cylinder extended INSTALLATION Do not power up the pump or hydraulic valve actuators until all hoses are properly connected to the pump A There is a serious risk of injury to fingers if inserted into the water port Danger If the user wishes to power up the motor or actuator before the installation is complete it is his responsibility to ensure that suitable safety measures are in place to prevent injury Issue 0 TIL Eng Spec 069 Page 10 of 24 Tritech International Ltd ZipJet Ultra OM Mechanical Installation The pump may be mounted in any orientation on the vehicle There is one main mounting point but any of the case bolts m
18. uards or other safety measures are in place to prevent injury The pump is designed for low maintenance operation The main materials are stainless steel and wear resistant polymer plastics The only internal moving parts that may need maintenance are The power pump impeller The hydraulic motor The retro flush valve spool The divertor valve vane The eductor set may need replacement after prolonged use with extremely abrasive materials or if aggressive chemicals have been encountered Basic maintenance procedures Pre Dive Visual check for external damage Check hoses are secure Check mountings are secure Check clean water suction strainer is in place and clear In active time If the vehicle will be in active for more than 48 hours or at demob Run a fresh water hose into the clean water suction strainer for a few minutes then spin the hydraulic motor for about 15 seconds taking care not to allow it to over speed Issue 0 TIL Eng Spec 069 Page 19 of 24 Tritech International Ltd ZipJet Ultra OM Storage If the pump is removed from the vehicle then the hydraulic ports should be blanked off with metal caps and the unit washed out with fresh water Leave the actuator valves in their retracted position Visually inspect the leading edges of the power pump impeller for damage and erosion Up to four blades may have leading edge damage of 5mm width and 4 mm depth before replacement becomes essential If th
19. uators Two independent controls are required one for each actuator The actuators can be connected to any standard three position 4 way solenoid valve Pilot operated check valves can be advantageous but a closed centre spool valve is adequate If either actuator is not used then they must be filled with oil and securely capped This is particularly important for the diverter which could easily be pilled open severely reducing efficiency The minimum supply pressure for reliable operation is 11Obar The actuators are rated for working pressures of up to 240bar Actuator connection fittings The actuators are supplied with No 4 JIC male fittings Hydraulic motor shaft seals Volvo produce two seals N type coloured blue and H type coloured red The H type is a high pressure seal and fitted as standard on the ZIPJet Ultra Replacement of seals with anything other than a genuine Volvo seal or Caution Tritech supplied seal will invalidate warranty Issue 0 TIL Eng Spec 069 Page 18 of 24 Tritech International Ltd ZipJet Ultra OM MAINTENANCE Do not power up the pump or hydraulic valve actuators until all hoses are properly connected to the pump There is a serious risk of injury to fingers if inserted in either the power Danger water intake or the pump delivery port If the user wishes to power up the motor or actuator before the installation is complete it is his responsibility to ensure that suitable g