1.                          Connection details  Integral cable    VE   White   VE   Yellow  Case earth   Grey       52 414 2164 01    
2. PTX 22  amp  PTX 23  PRESSURE  TRANSMITTERS   INSTALLATION  GUIDE           Designed  manufactured and supported by      LSTATUS   gt  INSTRUMENTS    Green Lane  Tewkesbury  Glos  GL20 8DE  UK  Telephone   01684 296818  Fax   01684 293746  Email  support status co uk    Every effort has been taken to ensure the accuracy of this  specification  however we do not accept responsibility for  damage  injury  loss or expense resulting from errors and  omissions  and we reserve the right of amendment without  notice     Stock code   52 414 2164 01 Issue  01             1 0 RECEIVING  amp  UNPACKING    THIS PACKAGE CONTAINS DELICATE MEASUREMENT EQUIPMENT  THAT REQUIRES CAREFUL HANDLING    Instruments are packed individually using packing materials which afford  excellent protection for normal handling     The external condition of the carton should be noted  with particular  attention for signs of damage from impact or puncture    When the goods are opened for inspection  ensure that the  Operating Instructions and Calibration Certificate  if requested  are  not accidentally lost or destroyed    Open the box to expose the transmitter including the electronics   and any other accessories if applicable     If the product has been specified for service with a critical media  requiring special cleaning  the outer protection should not be  removed unless under conditions of controlled cleanliness    All products are supplied in a calibrated condition  Do not change  any instrument setting
3. s when undertaking an examination for  damage in transit    Do not touch  blow down or press against the measurement  diaphragm as this can cause irreparable damage     2 0 SPECIFICATION  Pressure Range Standard DIN Ranges from  0 100 mBar to 0 to 25 Bar   0 1 to 0 5 bar   3 bar   0 5 to 2 bar   3 x FS  3 bar min   2 to 25 bar   3 x FS   Burst Pressure  gt  200 Bar    Over Pressure    Range 0 1 to 0 5 0 5to2 0 2 to 25 bar  Stability Zero 0 to 70  C 0 06 0 03 0 015   FS PC   25 to 85  C 0 08 0 04 0 02   Span 0 to 70  C 0 015 0 015 0 015   25 to 85  C0 02 0 02 0 02  Long term  lt 4mbar  lt 4mbar  lt 0 2  FS    Supply Voltage 11 to 33 VDC   Load Resistor  V_supply  11  x 10   ohms maximum  20   Output Signal 2 Wire  4 20mA    Operating Temp   Range Effects  Standard 0  C to  70  C  100 500 mbar 4  FS  500 mbar   2 bar 2  FS   gt 2 bar 1  FS  Accuracy Combined Non Linearity  Hysteresis  and Repeatability  The Output will not deviate from the  straight line connecting Zero and FS  output by more than  0 5  FS   Option  0 25  version  Electrical Connection By sealed cable with integral vent tube  either Pur or Teflon  Fluids compatible with a fully welded  assembly of stainless steel and  associated cable   Viton seal  Option  EDPM  Kalrez    Process Compatibility    If in doubt contact Sales Office who will be pleased to advise compatibility   3 0 INSTALLATION   For connection details see sections 6  amp  7     The installation should be undertaken in accordance with BS6739    Bri
4. tish Standard Code of practice for  Instrumentation in Process  Control Systems   Installation Design and Practice      All Status Instruments Ltd transmitters are designed to withstand  conditions normally found in process applications  however for maximum  instrument life and ease of maintenance the following guidelines should  be observed     Prior to installation  ensure the pressure source is not under pressure   Avoid installing the instrument in close proximity to motors  pumps   valves and heat sources  Excessive vibration or pressure peaks  may falsify the sensor readings or even damage the sensor    In most cases  the equipment is shipped with a protective cap   remove the cover and tighten the sensor assembly with a torque of  35Nm    Use screened vented cable with the screen connected to earth at  one end only    Maximum supply voltage should not exceed 33V DC     4 0 INITIAL COMMISSIONING    The instrument is supplied factory calibrated  No user adjustments are  available     5 0 CALIBRATION  In normal operation  calibration checks should be made on a regular  basis to ensure the accuracy of the transmitter system  Return the    instrument to the supplier if recalibration adjustment is required     6 0 WIRING DIAGRAM                                    7 0 MECHANICAL   CONNECTION DETAILS    7 1 PTX22 Submersible Version                      Connection details  Integral cable    VE   White   VE   Yellow  Case Earth   Grey    7 2 PTX23 Aggressive Chemical Version   
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
La Stratégie 2ed Edition - Seductdz`s Academy  尺寸:441*150mm - elRectangulo  Onkyo C-7070 Product Sheet  Informativo Comercial-2014_CABO-P-ESPELHO    HYDROMETTE BL COMPACT Istruzioni d`uso  Manual Kamstrup 382M  SL120 User Manual For Android  Cables Direct 3SR3-OUT  VGP-AC19V10 Operating Instructions    Copyright © All rights reserved. 
   Failed to retrieve file