Installation and User Guide SHOWER PUMP

image

Contents

1. 10 20 30 40 50 60 FLOW l min Mira Enduro Shower Pump Performance Graph Plumbing Connections 6 1 Inlet and outlet Kohler Mira recommend only the use of their 22 mm flexible hoses The hose is fitted with plastic push in connectors on one end which must only be connected with the following a 22 mm diameter copper pipe to BS EN 1057 R250 half hard Table 3 b 22 mm plastic pipe to BS 7291 part 1 and part 2 Table 1 or part 3 Table 1 plus internal support sleeve Note The internal bore of the plastic pipe must be supported against collapse with the pipe manufacturers recommended support sleeve pipe insert Appropriate plumbing fittings from the John Guest speedfit push in plumbing fitting range Note Other manufacturers fittings are not necessarily compatible and may not provide a water tight connection INSTALLATION Key to symbols used in the system layouts Servicing Valve gt Check Valve Pressure Switch Mixing Valve Pressure Accumulator S Float Operated Valve Float Type Automatic Air Vent Bottle Valve Shower Handset DHW Fixed Shower Head Domestic Hot Water 15 mm Diameter Pipe 22 Diameter Pipe Plumbing Installation must be carried out in accordance with these instructions and must be conducted by designated qualified and competent personnel 1 ATT
2. DHW Lo I 22 Mixing Valve System Layout for Mira Enduro Pump Figure 4 12 10 11 12 13 14 15 Care should be taken to ensure that all pipework fittings and connections are secure This is particularly important on the pump inlet pipework network due to the potential for air to be drawn into the system should suction conditions exist All connection pipework must be adequately and rigidly supported The flexible hoses supplied are primarily for vibration isolation and should be installed straight They may be bent to a maximum of 30 in which case they must be allowed to form a uniform swept curve and must not be stressed in any way by the plumbing configuration The pump motor is air cooled and it is important that the flow of air is not impeded around the appliance Damage to fabrics may occur if allowed to foul the motor air vents avoid a position in which the product could become frozen Do not rigidly secure pump unit to the mounting surface Install inlet and outlet pipework to meet pump flexible hoses flush through pipework fully before connecting to pump and then complete plumbing installation q Cistern Mixing Valve Unsuitable Layout for Mira Enduro Pump Figure 5 13 Unsuitable Layout for Mira Enduro Pump Figure 6 Mixing Valve gt
3. SHOWER PUMP Installation and User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER CONTENTS IMPORTANT SAFETY INFORMATION 3 WARNING aiii EE 3 CAUTION p 4 5 DESCRIPTION 5 PUMP LOCATION 5 OPERATION cas 6 PACK CONTENT ornat etin uto iine tuna suus 6 Documentation 6 DIMENSIONS EA TEE E 7 SPECIFICATIONS orrore kssr rte eir ae cadens iate rasa 8 INSTALLATION 10 Pl mbilg 10 Plumbing push in connectors cette eddie 15 Electrical 16 reme P P 17 COMMISSIONING erre 18 FAULT DIAGNOSIS nuoc ne etre ananasais 19 LM ugz hU leud 22 General anus aun 22 jer 22 DECLARATION OF CONFORMITY ener 22 SPARE E 23 Sparo eto 23 5 ve ens 23 CUSTOMER SERVICE eene rano een 24 IMPORTANT SAF
4. Unsuitable Layout for Mira Enduro Pump Figure 7 14 Plumbing push in connectors Do not use stainless steel chrome or nickel plated pipe with the flexible hose push in plumbing connections Do not introduce solder flux into the joint or surrounding area as plastics will be attacked and may fail All solder joints should be completed before final connection to push in connections on the flexible hose Flux residues must be removed Do not allow contact with oil or cellulose based paints paint thinners or strippers acid based descalents or aggressive cleaning agents 1 Make sure that the pipe is free from all score marks and deformities in the area of the insertion depth and cut the pipe square removing all burrs and sharp edges to prevent damage to the O seal Before inserting the pipe into the fitting mark the insert depth on the wall of the pipe with a soft pencil at a distance of 33 mm from the end to be inserted refer to illustration Check in the mouth of the fitting that the O seal nylon washer and collet are in position refer to illustration Collet Nylon Washer 22 mm Pipe Seal Pipe Stop Push the pipe firmly into the fitting until the pencil mark is level with the top of the collet and the pipe stop resistance is felt Pull on the pipe to make sure that it is secure and fitted correctly To release the joint push the pipe firmly into the fitting hold the collet d
5. START METHOD FLOWSWITCH REED S1 Schematic Wiring Diagram Figure 8 16 BLUE Link Wire BLUE BLACK BROWN BLUE N BROWN L 2 52 IMPORTANT CABLE SHOULD BE Dojo 5 ROUTED AS SHOWN 1 51 END OF OUTER ems SHEATH TO BE LEVEL omo Or WITH TERMINAL BLOCK AS SHOWN OX 7 FLOWSWITCH f n A REED LEADS SUPPLY LEAD FLOWSWITCH FLOWSWITCH REED Upper Electrical Box Wiring Diagram Figure 9 Earthing This appliance must be earthed via the supply cord which must be correctly connected to the earth point located in the terminal box Copper or metallic pipework must have supplementary earth bonding where the continuity has been broken by flexible hoses or plastic components Adjacent suction and delivery pipes should be fitted with earthing clamps to BS 951 and connected with earthing wire size 4 mm refer to the following illustration Certain installations may require additional earthing arrangements such as equipotential bonding Reference should be made to the relevant regulations concerning this subject to make sure of compliance Diagram of earth continuity connections 17 COMMISSIONING Commissioning must be carried out in accordance with these ins
6. 01 459 1344 E mail sales modernplant ie Fax Dublin 01 459 2329 Post Otter House Naas Road Clondalkin Dublin 22 mira SHOWERS QUALITY MANAGEMENT FM 14648 Kohler Mira Limited August 2009
7. Pipework configuration and or water supply conditions are causing air induction 4 The pump a Installation 1 Vibration from the pump body is noisy in fault transmitted through reverberant operation material Checkthe pump position N B All pumps and pipework securings generate some Note The pump should be free noise Installation standing on its rubber feet and conditions may not screwed down allow this to be 2 Fault in the supply to the pump amplified refer to symptom 3 b Pump impeded 1 Check for debris and or damage internally in impeller housing 2 Mechanical seal worn damaged Renew Motor fault refer to symptom 5 d 5 The pump a Power supply 1 Check all fuses and RCD Make switches off while fault sure the power supply is available in use at the pump terminal box b Water supply 1 Refer to symptom 3 fault c Motor thermal 1 Allow the motor to cool up to switch tripped 1 hour 2 Check the ambient air temperature around the pump does not exceed 40 C 3 Make sure adequate free ventilation is provided minimum clearance of 80 mm around all sides of the pump 4 Pump impeded internally refer to symptom 4 b 20 Symptom Cause Rectification 5 Pump switches d Motor fault off while in use Contact Customer Service referto the back page of this guide for details continued 6 Leak from a Seal worn 1 If the leak is from rear of the
8. ENTION Damage is likely to occur to the pump unit if it is allowed to run dry A minimum pump inlet head pressure of 1 metre must be ensured at all times 2 Do not fit a non return valve in suction line inlet pipework to the pump The pump must be free to vent to the supply tanks at all times 3 Pressure loss throughout the inlet pipework network must be kept to the minimum possible to avoid operational difficulties This will mean the use of shortest pipe runs adequately sized for the maximum flow demand and with the minimum of restriction through elbows and fittings Long pipe runs should be avoided and are best reserved for pipework from the pump outlet to shower fittings 4 Pipework configurations which can allow air locks to form should be avoided For inlet pipework this should be achieved by utilising pipe runs with a continuous fall For outlet pipework either provide a continuously rising pipe run or if an up and over pipe run is unavoidable fit a float type automatic air vent at the highest point as shown in Figure 3 and 4 5 The pump must be sited as low as possible in relation to the water source and mounted in a horizontal position with the outlet connection vertically upwards The operation of the flow switch will be impaired in any other position 10 6 The hot feed from the cylinder must be as illustrated in Figure 2 Side entry cylinder bosses are not recommended A drop in cylinder water level could expose a t
9. ETY INFORMATION A WARNING 10 11 12 Products manufactured by us are safe and without risk provided they are installed used and maintained in good working order in accordance with our instructions and recommendations THIS APPLIANCE MUST BE EARTHED ENSURE SUPPLEMENTARY BONDING COMPLIES WITH THE REQUIREMENTS FOR ELECTRICAL INSTALLATIONS In accordance with the current edition of The Plugs and Sockets Safety Regulations in force at the time of installation this Mira Enduro is intended to be permanently connected to the fixed electrical wiring of the mains system The Mira Enduro must not be fitted where it may be exposed to freezing conditions Make sure that any pipework that could become frozen is properly insulated DO NOT operate the Mira Enduro if it is frozen Allow the Mira Enduro to thaw before using again DO NOT operate the Mira Enduro if water leaks from the unit maintenance will be required before the Mira Enduro can be safely used DO NOT allow the Mira Enduro to be run dry DO NOT run the pump without the guards and covers correctly fitted DO NOT obstruct the flow of air around the motor and it must be dust free as the pump motor is air cooled The inclusion of a Residual Current Device RCD Earth trip with a trip current of 30 mA is recommended This may already be part of the consumer unit There are no user serviceable components beneath the cover of the Mira Enduro Only a compet
10. ally achieve the flow rate required However long pipe runs or restrictive terminal fittings will increase the gravity head required to produce the required flow To overcome an initial low flow rate in the outlet pipe itis possible to by pass the function of the flow switch by the addition of a momentary action switch connected in parallel with the flow switch as shown in Figure 8 When the mixing valve is set to on and the switch operated the pump will run The pump will maintain the necessary flow rate in the outlet pipe and will continue to operate until the mixing valve is set to off PACK CONTENTS Examine the contents of the pack and tick the appropriate boxes to familiarise yourself with the part names and to confirm that all parts are included 1 x Mira Enduro Pump 4 x Flexible Hoses L Documentation 1 x Installation and User Guide 1 x Customer Support Brochure 4 x Fibre Washer All dimensions are nominal and in millimetres Figure 1 SPECIFICATIONS 1 Weight Mira Enduro Shower Pump 7 7 kg Packed 2 Ambient Temperature The ambient temperature arou
11. e commencing installation Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering Particular consideration should be given to the young the elderly the infirm or anyone inexperienced in the correct operation of the controls When the Mira Enduro has reached the end of its serviceable life it should be disposed of in a safe manner in accordance with current local authority recycling or waste disposal policy 4 INTRODUCTION Thank you for purchasing a quality Mira product To enjoy the full potential of your new product please take time to read this guide thoroughly having done so keep it safe for future reference DESCRIPTION The Mira Enduro twin impeller regenerative pump is designed to receive a hot and cold gravity supply and provide a pressurised hot and cold supply to a mixing valve refer to Figures 2 3 and 4 Pump Location The pump is more effective when pushing water along a pipe rather than pulling Thus the pump is best positioned as close to the hot water or blend water source as possible to reduce cavitation air bubbles in the pipes The greater the static inlet water pressure on the pump the better it will operate refer to the Mira Enduro Shower Pump Performance Graph Thus positioning a pump at high level is not advantageous and may result in inferior performance If it is not possible to locate the pump in the preferred area due to
12. ent tradesperson should remove the cover If any of the following conditions occur isolate the electricity and water supplies 11 1 If the guards and covers are not correctly fitted and water has entered 11 2 If the guards or covers are damaged 11 3 If the Mira Enduro begins to make an odd noise smell or smoke 11 4 If the Mira Enduro shows signs of a distinct change in performance indicating a need for maintenance 11 5 If the Mira Enduro is frozen Contact Customer Service refer to the back page of this guide for details Turn off the electrical and water supplies before removing guards or covers The electricity must be turned off at the mains and the appropriate circuit fuse removed if applicable 13 14 15 16 Mains connections are exposed when the guards and covers are removed Moving parts are exposed when the guards and covers are removed Refer to the wiring diagram before making any electrical connections Ensure all electrical connections are tight to prevent overheating CAUTION 1 2 3 Read all of these instructions and retain this guide for later use Pass on this guide in the event of change of ownership of the installation site Follow all warnings cautions and instructions contained in this guide Follow all warnings cautions and instructions contained on or inside the Mira Enduro The electrical installation must comply with the Requirements for Electrical Installations c
13. fault diagnosis section should determine the cause and rectification for any difficulty experienced with the operation of this pump If further assistance is required contact Customer Service refer to the back page of this guide for details Storage If this product is not installed immediately upon receipt make sure that it is stored in a dry frost and vibration free environment in its original packing DECLARATION OF CONFORMITY 98 37 EC BS EN ISO 12100 1 BS EN ISO 12100 2 BS EN 809 2006 95 EC BS EN 60335 1 BS EN 60335 2 41 EN 50366 2004 108 EC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY ON THAMES OXFORDSHIRE RG9 2AD ENGLAND Signed Quality Manager Stuart Turner are an approved company to BS EN ISO 9001 2000 Manufactured on behalf of Kohler Mira by Stuart Turner Ltd Henley on Thames Oxfordshire RG9 2AD 22 SPARE PARTS Spare Parts List 465 01 O Seal Pack including Mechanical Seal components identified 465 02 Flow Switch Module 465 03 Flow Switch Mechanism 465 04 Flexible Hose Assembly 465 05 Rubber Feet 465 06 Screw Pack n
14. he isolating valves are 0 6 l min fully open and other restrictions 4 Check the system has adequate static head and flow potential refer to Operation 5 The flow switch mechanism is sticking c Internal 1 New installation Check the problem wiring in the electrical boxes refer to Figure 8 2 Check continuity of the flow switch reed refer to Note 1 at end of this section 3 Pump impeded internally refer to symptom 6 b The pump has d Motor thermal 1 Allow the motor to cool up to been in use and switch tripped 1 hour refer to symptom 6 c stopped within a short period 2 The pump a Flow switch 1 Air pocket after pump Locate and operates operating make sure adequate venting momentarily when due to water 2 Air pocket in the pump supply not required movement in hot expanding due to system pipework heating Correct pipework layout to eliminate thermal flow fit a single check valve close to and after pump outlet refer to Note 2 at end of this section b Flow switch 1 Local source of strong reed PCB electromagnetic radio tripping transmission Shield flow switch reed tinfoil Symptom Cause Rectification 3 Pumped a Water supply 1 Check that hot and cold storage flow pressure is fault volumes are sufficient for initially adequate demand but reduces after 2 Check that all supply strainers short time including the mixing valve are clean 3
15. m approved stockists or merchants locations on request Spare parts will normally be despatched within two working days Payment can be made using most major Credit or Debit cards at the time of ordering Should payment by cheque be preferred a pro forma invoice will be sent All spares are guaranteed for 12 months from the date of purchase Spares that have been supplied directly from us can be returned within one month from the date of purchase providing that they are in good order and the packaging is unopened Note Returned spares will be subject to a 1596 restocking charge and authorisation must be obtained before return Please contact our Customer Services Team Note In the interests of safety spares requiring exposure to mains voltages should only be fitted by competent persons Service Repairs Our Service Force is available to provide a quality service ata reasonable cost You will have the assurance of a Mira trained engineer agent genuine Mira spare parts and a 12 month guarantee on the repair Payment should be made directly to the engineer agent who will accept most major Credit or Debit cards or a cheque supported by a banker s card To Contact Us England Scotland Wales and Northern Ireland Mira Showers Customer Services Telephone 0844 571 5000 E mail technical mirashowers com Fax 01242 282595 By Post Cromwell Road Cheltenham Gloucestershire GL52 5EP Eire Modern Plant Ltd Dublin Telephone
16. nd the pump must not exceed 40 C 3 Electrical 3 1 Protection the motor is fitted with a self resetting thermal overload trip Enclosure protection to IP22 Class F insulation 3 2 Duty continuously rated 3 3 Power Supply single phase 230 240 V 50 Hz fused supply through a double pole switched connection unit fitted with a 5 A fuse and with a minimum of 3 mm contact separation gap between terminals 3 4 Absorbed Power approximately 420 W at 1 8 amps 4 Water 4 1 Maximum Hot Water Temperature 65 C The use of hot water above 60 C is not recommended as this may lead to an increased risk of cavitation air bubbles which increases the pump noise generated and can lead to a reduction in the ultimate service life It is recommended that the stored temperature of water should never exceed 65 C A stored water temperature of 60 C is considered sufficient to meet all normal requirements and will minimize the deposition of scale in hard water areas 4 2 Delivery Rates See Pump Performance Graph This is for the pump with external flow switch only Terminal fittings and associated pipe work will reduce this figure 4 3 Inlet Pressure Minimum inlet static pressure 0 1 bar must be maintained at all times Maximum static inlet pressure 1 4 bar 5 Standards and Approvals The Mira Enduro complies with all relevant directives for CE marking 6 20 HEAD Metres o
17. ommonly referred to as the IEE Wiring Regulations or any particular regulations and practices specified by the local electricity supply company in force at the time of installation The installation should be carried out by an electrician or contractor who is registered or is a member of an association such as 5 1 National Inspection Council for Electrical Installation and Contracting NICEIC throughout the UK 5 2 Electrical Contractors Association ECA England and Wales 5 3 The Electrical Contractors Association of Scotland ECAS The plumbing installation must comply with Water Supply Regulations Bye laws Scotland Building Regulations or any particular regulations and practices specified by the local water company or water undertakers The installation should be carried out by a plumber or contractor who is registered or is a member of an association such as 6 1 Institute of Plumbing IPHE throughout the UK 6 2 National Association of Plumbing Heating and Mechanical Services Contractors NAPH amp MSC England and Wales 6 3 Scottish and Northern Ireland Plumbing Employers Federation SNIPEF Scotland and Northern Ireland System configurations or pump applications other than those shown refer to Figures 2 3 and 4 may cause inefficient or impaired operation of the system which may damage the pump unit If the system configurations shown are not possible consult Kohler Mira for advice befor
18. op entry immersion element Air in water gathers at the edge of the cylinder and in the centre during the heating process before travelling up the vent 7 Water pumps can develop leaks and should therefore not be located where seepage may go undetected or cause damage The pump must be installed such that it is accessible for servicing or removal When servicing or disconnecting small amounts of water may drain from the unit and pipework 8 Care should be taken when using soldering flux Protect the pump from damage whilst making soldered connections as some fluxes cause damage to plastic components 9 It is recommended that inlet and outlet isolation valves eg gate valves are fitted to permit isolation of the pump for servicing C 25 mm an Warning Pipe Or i Overflow LOM 5 Oe E 85 Cisten DHW Cylinder Cold Feed to Minimum Feed Mixing Valve 1 5m n with other Siasa simultaneous hot water services 2 0 30 to 60 Air Separation Connections Other Hot Water Services System Layout for Mira Enduro Pump Figure 2 11 e Mixing Valve System Layout for Mira Enduro Pump Figure 3 ED
19. ot illustrated 465 08 Impeller Assembly 465 09 Push Fit Pack for flexible hose 465 11 Inlet Housing Connector 872 56 Cable Tie 1587 002 Motor Control PCB not illustrated Spare Parts Diagram CUSTOMER SERVICE Guarantee of Quality Mira Showers guarantee your product against any defect in materials or workmanship provided that it is installed and maintained in accordance with the instructions given in this guide To validate the guarantee please return your completed registration card within 30 days of product installation Within the guarantee period we will resolve defects free of charge by repairing or replacing parts or modules as we may choose To be free of charge service work must only be undertaken by Mira Showers or our approved agents Service under this guarantee does not affect the expiry date of the guarantee The guarantee on any exchanged parts or product ends when the normal product guarantee period expires Not covered by this guarantee Planned maintenance or replacement parts required to comply with the servicing requirements of the TMV 2 and TMV 3 healthcare schemes where applicable Damage or defects arising from incorrect installation improper use or lack of maintenance including build up of limescale Damage or defects if the product is taken apart repaired or modified by any persons not authorised by Mira Showers or our approved agents This guarantee is in addition to your stat
20. own and gently remove the pipe Caution Be careful when draining any residual water QE sE 5 o 15 Electrical A Before starting work on the electrical installation make sure that the power supply is isolated Cable selection and corresponding fuse size should be chosen in accordance with the current involved and surrounding conditions All electrical installation work should be carried out by a competent person 1 The unit is fitted with 1 3 metres of supply cable Should this cable be too short a suitable length of three core cable minimum 0 75 mm per core should be obtained and connected to the terminal block in the electrical box refer to Figure 8 Remove the electrical box cover by unscrewing the four retaining screws The supply cable and internal wiring within the terminal box are routed and secured for compliance with the electrical standard EN60335 1 After replacing the supply cable make sure that the factory routing and securing of all wiring is always maintained as shown in Figure 9 2 Do not use long cable lengths as this may cause substantial voltage drop poor pump performance and could also result in motor overload MAIN WINDING CAPACITOR 2 5 2 a 9 START WINDING a 8 BLUE N 230 VAC RIRAN 1 Ph 50 Hz N M N L 51 52 52 81 GREEN YELLOW E SUPPLY FLOWSWITCH OPTONALALIERNATWE REED 52
21. pump housing damaged impeller housing at junction with the motor assembly the mechanical seal requires renewal If the leak is from the perimeter of the impeller housing then the housing seals require renewal b Inlet pressure above maximum permitted Refer to Specifications Note 1 The flow switch continuity should be checked with the power switched off and one flow switch lead disconnected Use appropriate continuity meter Correct operation is open circuit with no flow and closed circuit with flow Note 2 Fitting a check valve is a secondary measure initially the cause of water surge should be investigated and rectified The single check valve should be of spring loaded pattern and fitted in the discharge pipework This may increase the minimum head pressure required to operate the flow switch 21 MAINTENANCE General Mira products are precision engineered and should give continued superior and safe performance Providing that the pump has been correctly installed and operated as advised in this booklet difficulties should not arise A WARNING ISOLATE POWER SUPPLY BEFORE REMOVING THE PUMP TERMINAL BOX COVER Components are precision made so care must be taken during servicing to avoid damage When ordering spare parts please state product type i e Mira Enduro and identify part name and number refer to Spare Parts List Regular preventative maintenance is not required The
22. site limitations and it is necessary to position the pump at high level or in a position above the secondary tapping that feeds the pump then there is an increased risk of air locks This risk must be eliminated Due consideration should be given to the pump position as any noise generated may be amplified by installation conditions such as reverberant panels bare floorboards etc Make sure adequate free ventilation is provided minimum clearance of 80 mm around all sides of pump The hot water storage temperature should not exceed 60 C Operation at this temperature will also reduce the rate of formation of limescale in the system The stored hot and cold water volumes should be sufficient for the required duty typical flow rates for a shower outlet are 10 I min Instantaneous or combination heaters are not suitable It is not recommended that other services use the same feed pipework as the mixer valve or pump unit as operation problems may occur OPERATION The pump would normally start automatically when the mixing valve is set to open When the flow rate through the outlet pipe is more than 0 6 l min a magnetic float lifts and closes the contacts of the flow switch sensor When this occurs the electrical circuit to the motor is completed and the pump operates The opposite action occurs when the flow stops Avertical distance of 100 mm between the water discharge point of the shower outlet and the base of the cistern would typic
23. tructions and must be conducted by designated qualified and competent personnel 1 2 3 Make sure the pump is isolated electrically Make sure that all isolating valves are fully open and the pump chamber is flooded Open an outlet e g shower control Water should flow from the outlet under pressure of gravity Leave an outlet open for a short period to allow air to be expelled from system ATTENTION The flow rate must be at least 0 6 l min for the flow switch to operation Close the outlet Switch on the power supply to the pump If the pump operates repeat the commissioning steps 1 4 if this fails refer to the Fault Diagnosis N AN WARNING The motor casing can become very hot under normal operating conditions Care must be taken to make sure that it cannot be touched or covered during normal operation Open an outlet and check that the pump operates automatically If the pump does not operate repeat the commissioning procedure refer to Fault Diagnosis 18 FAULT DIAGNOSIS Symptom Cause Rectification 1 Pump does not No power 1 Check all fuses and RCD Make start supply sure power supply is available at the pump terminal box If fuse blows repeatedly refer to symptom 6 b b flow 1 Clean the shower heads and through make sure the flow controls are terminal fittings operating correctly flow switch 2 Check for air locks needs typically 3 Check t
24. utory and other legal rights What to do if something goes wrong If when you first use your shower it doesn t function correctly first contact your installer to check that installation and commissioning are satisfactory and in accordance with the instructions in this manual We are on hand to offer you or your installer any advice you may need Should this not resolve the difficulty simply contact our Customer Services Team who will give every assistance and if necessary arrange for our service engineer to visit If the performance of your shower declines consult this manual to see whether simple home maintenance is required Please call our Customer Services Team to talk the difficulty through request a service under guarantee if applicable or take advantage of our comprehensive After Sales service As part of our quality and training programme calls may be recorded or monitored Our Customer Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit 5 0135181042285 1074846 W2 D P81B 18719 2209 1 04 Mira is a registered trade mark of Kohler Mira Limited The company reserves the right to alter product specifications without notice www mirashowers co uk Spare Parts We maintain an extensive stock of spares and aim to provide support throughout the product s expected life Genuine Mira spares can be purchased direct from Customer Services or fro