1. PowerStar Horticultural righting Contactor User Guide Technics Introduction Most growers choose to use High Intensity Discharge lighting in there Growrooms HID lighting is the most effective possible form of lighting for horticultural use Sodium amp Metal Halide lights are most commonly used and are of the HID Variety HID lamps require large amounts of current to flow when they are first turned on the amount of power required to start the lamp can be up to twice the normal running power and will increase as the lamp gets older Most growers use a 24 Hour timer to set the day length in their grow rooms However most 24 Hour timers are not designed to allow high current switching and normally fail very quickly when used with HID lighting loads due to this high power relays are normally used to switch the power to the lighting system so the timer is only used for control The large startup current is caused by a number of factors Firstly there is a very large initial inrush current drawn by the ballast unit this is only present for a fraction of a second Secondly a situation known as Lamp Rectification rectification occurs when the two ends of the lamp heat up at different rates causing a DC current to flow in the lamp this DC current causes saturation of the ballast core which reduces the impedance of the ballast causing more current to flow through the lamp this situation only lasts for a few seco
2. Timer Powerstar October 2011 document revision Safety Advice ALWAYS OBSERVE THE FOLLOWING When connecting disconnecting all cables grasp the connector itself never pull on the cable This way you will avoid causing shorts or damage to the cable s internal elements Do not excessively twist or bend the power cord or place heavy objects on it Doing so can damage the cord producing severed elements and short circuits Damaged cords are fire and shock hazards In households with small children an adult should provide supervision which is essential for the safe operation of any electrical appliances in the home All cords and cables should be placed so they are out of the reach of children Try to prevent cords and cables from becoming entangled Before moving the unit disconnect the power cable from the mains supply and any cords coming from external devices Never handle an AC adaptor or electrical plugs with wet hands when plugging into or unplugging from an outlet or this unit Before cleaning the unit turn off the power and unplug the AC adaptor from the outlet Do not force the unit s power supply cord to share an outlet with an unreasonable number of other devices Be especially careful when using extension cords the total power used by all devices you have connected to the extension cord s outlet must never exceed the power rating watts amperes for the extension cord Ex
3. cessive loads can cause the insulation on the cord to heat up and eventually melt through Protect the unit from strong impact Do not drop it Before using the unit in a foreign country consult with your retailer or an authorized distributor Whenever you suspect the possibility of lightning in your area disconnect the unit from the power outlet Do not attempt to repair the unit or replace parts within it Refer all servicing to your retailer or an authorized distributor When moved from one location to another where the temperature and or humidity is very different water droplets condensation may form inside the unit Damage or malfunction may result if you attempt to use the unit in this condition Therefore before using the unit you must allow it to stand for several hours until the condensation has completely evaporated TE _ ECOTECHNICS PRODUCT GUARANTEE Thank you for choosing an Ecotechnics product for use in your growroom As manufacturers of horticultural eee we parts amp labor guarantee and should to the retailer along with a _ the origi al purchase receipt i ge un caused Ka Shop Dealer 3 Purchase Date x EA DMMYY BT serial Number sum P 6 I Technics www ecotechnics co uk
4. nds whilst the lamp is warming up and stops once lamp operating temperature is reached This situation will always occur but tends to get worse as the lamp gets older for this reason it is best to over rate contactor systems by about 30 to allow for lamp degradation Load Recommendations Due to the reasons stated above it can be seen that starting currents are considerably higher than running currents typically as shown in the table below Lamp Start up current in amps Running current in amps 250w Son T 400w Son T 600w Son T 1000w Son T Setup and Use The Ecotechnics PowerStar Contactors have been specifically designed to allow the timed switching of horticultural lighting and appliances In use the PowerStar Contactor is very simple and should provide years of trouble free use Locate CONTACTOR in a suitable position in your growroom Plug lights and appliances into 4 way power outlet Set TIMER in normal way Insert TIMER PLUG into a 24Hr TIMER Plug TIMER and POWER IN PLUG into power points and switch on a 1 The lights and appliances plugged into your contactor will now be controlled by the timer Digital or Analogue timers can be used and will last their full service life Recommended Maximum Loads For PowerStar Contactors 1 way 2 way 3 way 4 way 1Kw PowerStar 2Kw PowerStar 3Kw PowerStar 3Kw PowerStar contactor contactor contactor contactor Connection Diagram
Download Pdf Manuals
Related Search
Related Contents
Série 4000 Guide d`installation ー耐久性能抜群のオールステンレスを採用〝 ー耐久 703429-WB Rev F - Multiple Language Control Unit User's Manual TE70X, TE70XP, TE77X and TE77XP User Manual 取扱説明書 South Shore Furniture 3210070 Instructions / Assembly COBRA Procedures and Basic Compliance Rules for Employers 取扱説明書 - オンキヨー Mise en garde XMT 5 Series User`s Manual V2.10 - Koncept-L Copyright © All rights reserved.
Failed to retrieve file