        Installation Instructions and User Guide
         Contents
1.    1  The designation of the thermostatic  mixing valve matches the intended  application     2   he supply pressures are within the  range of operating pressures for the  designation of the valve     3  The supply temperatures are within the  range permitted for the valve and by  guidance Information on the prevention  of legionella etc     4  Isolating valves  and strainers preferred   are provided     If all these conditions are met  proceed to  set the temperature as stipulated in the  maintenance section     The mixed water temperature at the  terminal fitting must never exceed 46  C     Itis a requirement that all TMV3 approved  valves shall be verified against the original  set temperature results once a year  When  commissioning   testing is due the  following performance checks shall be  carried out     e Measure the mixed water temperature  at the outlet     e Carry out the cold water supply Isolation  test by isolating the cold water supply to  the TMV  Thermostatic Mixer Valve      walt for five seconds  If the water Is still  flowing check that the temperature Is  below 46  C     If there is no Significant change to the set  temperature     2  C or less change from  the original settings  and the fail safe shut  off is functioning  then the valve Is working  correctly and no further service work Is  required     Notes  If there is a residual flow during the  commissioning or the annual verification   cold water supply isolation test   then this  is acceptable pro
2.    APP  PR     lt 9  TNA  ov    BRISTAN    Installation Instructions    and User Guide    Opac Lever Ihermostatic  Shower Valve          Models covered  OP 151503 EL C   OP 151503 CL C  OP 151503 ISOL C   OP TS1503 SCL C    Please keep this booklet for future  Reference    Installer  when you have read these  instructions please ensure you leave them  with the user     Contents    Thank you for choosing Bristan  the UK s leading taps and showers expert  We have  designed this product with your enjoyment in mind  To ensure that it works to its  full potential  it needs to be fitted correctly  These fitting Instructions have been  created to give you all of the Information you need and  If you need any further help     please do not hesitate to give us a call on 0844 701 6273     Important Safety Information         cece cece ct esseeteeseeeee       Gonera IAO aO aese ina Mr mene meen Sere en eee 4  Product F evs 0  pos een eR erty oa Pete eer eee moreno en arte eer er ore o  IPCI AUO a a a a 6  D A gisterree ere ene ence eer E ener terre ONS 7 10    Installation Requirements 0    cece see csecesteectesetcsesesteeetstseseeeee 11712    FOW ne clO   hehG  cow meme ete ee ene Tete nn Miter aera Snennemn nett Cak  EEE E OU AE EN ANE AAEE TEE EEEE E 19 20  Operation  amp  Temperature Setting oo    eee cee retterne tnrterers reenen 21     olga gi O gle lmmene ne merece E Pe RT em etme tre Neem Retr ae 22  IM OErVCE TES UNT eraeeemenetr merit E e eecan erin nena eee ree 23 24    Maint
3.    Adaptor    Flow  Regulator    4  Attach the shower valve        Insert the 15mm hot and cold water  Isolation    Elbow  tighten the nuts  Ensure the olives and Compression    Supply pipes Into the Inlet connections and  filter are in place  Nut    Secure the shower valve to the backplate  by tightening the backplate grub screw     9  Fit the concealing plate Fixings        Once the valve Is installed into position  within the wall cavity screw the concealing  plate fixing onto the finished wall surface    using the fixings supplied  Concealing   Plate F  Slide the concealing plate over PERYA a ae  the sleeve of the valve me NY    firmly against the wall aS  surface ensuring the P     concealing seal is fitted   M aN     between the concealing        Concealing  plate and the concealing AN     Plate Fixing  plate fixing  eand l Concealing   J Plate Seal  bss AA    18 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Installation cont        OP 151503 SCL C    Before Installation   Important  Water supplies to the mixer  must be with hot on the left and cold on  the right when views from the front     Flush through the pipework to ensure  removal of debris  Turn off the mains  water supply and close any Isolating    valves  125 132mm    1  Inlet positions   The shower valve has three inlet positions    top  bottom and rear  Rotate the inlet  elbows as required     With the elbows screwed fully against the  valve body It can be unscrewed 
4.    must be with hot on the left and cold on    removal of debris  Turn off the mains the right when views from the front     water supply and close any Isolating    valves  175mm    Important  It is essential when installing  this Shower valve full access Is made  available for future servicing purposes     1  Inlet positions  The shower valve has three inlet positions    top  bottom and rear  Rotate the inlet       elbows as required  Ae Backplate  Once the required position of the Inlet fixing holes  supply has been identified sufficient 15mm   Kn   M    diameter supply pipes should protrude  through the finished wall surface with  1 9mm between centres to fit fully into the    shower valve elbows     2  Attach backplate to wall   Using the backplate as a template mark  the centres of the fixing holes onto the  wall     MN Warning  Please check for any hidden  pipes and cables before drilling holes in  the wall    Drill suitable holes and insert the wall  plugs  Securely attach the backplate to the  wall using the screws provided        Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  17    Installation cont        OP TS1503 CL C  Concealed  continued     3  Attach isolation elbows to mixer valve  This valve is supplied with isolation elbows    which need to be fitted as shown opposite  l  Filter    With the elbows screwed fully against the Washer  valve body It can be unscrewed a  maximum of 1 9 turns to allow for lateral       tolerance
5.    rome ole  nfelmlol lelelolo    6 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     DIMENSIONS  mm s        OP TS1503 EL C  Surface Mounted        148   158    Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  7    DIMENSIONS  mm s        OP TS1503 CL C  Concealed Model          j   Rese Ps   60      ie  127      Suitable for wall cavity depths  of between 63 9 72 9mm        8 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     DIMENSIONS  mm s        OP 151503 ISOL C       i  k   pi 7 pee              E     S l  l i i if j         ji i i    e bast Mi         135   l 48         173    Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  9    DIMENSIONS  mm s        OP 151503 SCL C         125 132     centres    172    10 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Installation Requirements       These fittings need to be installed in   accordance with the following Installation a eee ree  Requirements and Notes  IRN  to ensure COMO NAT On HENS  ih opp tee  they meet the requirements of the Water P    Supply  Water Fittings  Regulations 1999 1  Not exceeding 1 2 20  and the Scottish Byelaws 2004  in se    IRN R001  See text of entry for Installation 2  Exceeding 1 2 in  Requirements or Notes  but not exceeding    Size of tap or Vertical distance    IRN R040   Schedule 2 15  1   The 3 4 in    f
6.   but no longer performs  acceptably  you may find it useful to  firstly refer to the fault diagnosis in the  Troubleshooting section     Should the valve require servicing the  following procedure should be followed     e  solate both hot and cold supplies to the  shower valve by either     e Turning the water supply off at the mains  stop cock or    e Turning off the isolation valves to the  shower valve     e Prise out the cap from the handle   Loosen the grub screw and pull the  handle off     e Remove the concealing shroud   concealed model only      e Remove the retaining ring by pulling it off  from the exposed cartridge head and  remove the Sleeve     e Unscrew the cartridge using a suitable  Spanner and remove from the valve body  ensuring the piston and thermostat   assembly is also removed from the body     e Unscrew the half cartridge  bottom  section of the cartridge  by inserting a flat  tool into the slots and a suitable spanner  onto the hexagonal part of the cartridge  head and unscrew  The half cartridge has  a standard right hand thread     e Remove circlip and push out spindle  assembly     e Remove all O  rings and washers from  spindle assembly  unscrew spindle  left  hand thread  and remove adjusting screw  from the spindle housing  noting the  approximate number of turns to release     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  25    Maintenance cont        e Soak all metal parts in a 50 50  solution of hot wat
7.  closed position  Only adjust if  instructed to do so in the table on page 13 or when fitting a replacement cartridge  assembly   See maintenance section    ee A Important  It is a requirement of Instantaneous Electric Water Heaters that a  Stable flow of water passes through the heater  This requirement can be satisfied by  using a flow stabiliser in the supply to the heater  It should be adjusted to give a flow  temperature of 45 50  C from the heater        Elbow O    Ring To Body  To Pipework a 7 ini f  j a ty    iain boc  MH Green Limiter  li M i    Ring WW 7 Litre     _  W    ff RX  L r  AA ET MN    WY per A  MA MA Yellow Limiter  wee y Way    Check Valve Y    WZ Sos  Washer   TN  g  White Orifice  M Disc    14 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Installation    OP 151503 EH C  OP 151503 ISOL C    Before Installation   Flush through the pipework to ensure  removal of debris  Turn off the mains  water supply and close any Isolating  valves     1  Inlet positions   The shower valve has three inlet positions    top  bottom and rear  Rotate the inlet  elbows as required     With the elbows screwed fully against the  valve body It can be unscrewed a  maximum of 1 5 turns to allow for lateral  tolerance     Sufficient 19mm diameter supply pipes  should protrude through the finished wall  surface to fit fully into the shower valve  elbows     2  Attach backplate to wall   Loosen the backplate    grub screw on the  backplate u
8.  protection      Unplug equipment after use       The fitting of isolating valves Is required as close as is practical to the supply inlet  feeds of the thermostatic mixing valve    e The fitting of strainers is recommended as close as is practical to the water supply  inlets of the thermostatic mixing valve    z   N Warning  Before installing the new shower valve it is essential that you  thoroughly flush through the pipework in order to remove any remaining swarf  solder   etc  Failure to carry out this procedure could cause problems or damage to the  workings of the shower valve     e This product must not be modified in any way as this will invalidate the guarantee     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  3    General Information       This product has been tested to the TMV3 scheme which complies with the BS EN  1287 1999  LP  and BS EN 1111 1999  HP  thermostatic mixing valve standards and  satisfies the requirements of the Water Supply  Water Fittings  Regulations 1999 and    current bylaws     BS6 00 recommends the temperature of stored water should never exceed 69  C  A  stored water temperature of 60  C Is considered sufficient to meet all normal  requirements and will minimise the build up of lime scale in hard water areas  see Map    of Hard Water Regions in the UK on page 27      If the fitting is installed at low pressure  tank fed   then the minimum distance from the  highest installed position of the showerhead t
9. a       maximum of 1 5 turns to allow for lateral aie Backplate    tolerance  fixing holes  Sufficient 19mm diameter supply pipes  Should protrude through the finished wall  surface to fit fully into the shower valve    elbows     2  Attach backplate cover to wall  Remove the backplate cover    from the  shroud using a hexagonal key    Use the backplate cover as a template and  mark the centres of the fixing holes onto  the wall     LN Warning  Please check for any hidden  pipes and cables before drilling holes In  the wall     Drill suitable holes and insert the wall  plugs  Securely attach the backplate to the  wall using the screws provided        Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  19    Installation cont        OP TS1503 SCL C continued    3  Attach shower valve to backplate cover  Insert the 19mm hot and cold water   Supply pipes into the Inlet connections and  tighten the nuts  Ensure the olives and  filter are In place     4  Fit the cover shroud   Slide the cover shroud over the shower valve  and push onto the backplate cover until it  clips Into place    Note  The lever handle may need to be  removed from the shower valve in order to       push the cover shroud into position     tea   n  ie  E al  a oo i e  A  ii Fee   I Die   B T r H  ra i toa i  Sc L Th  if  li a  b    i a  be j    j E pi 7        ie      ws     lt a     tag  a  5       hi    20 Need help  Give us a call on 0844 701 6273 and speak to one of our trai
10. ar parts  1 year labour   subject to  registration      Electric Showers Instantaneous Water  Heaters   2 year parts  1 year labour   subject to  registration      Accessories   o year parts only  Includes bathrooms  accessories  shower accessories  e g   hoses  handsets and poles   wastes  WC  levers and light pulls  Gold  painted and  special finishes 3 years parts only     Sanitaryware  o year parts only  Subject to proof of  purchase     Shower Enclosures and Shower Trays  10 year parts  subject to registration   or 2  years with proof of purchase  1 year  labour   subject to registration   or 1 year  with proof of purchase     Heated Towel Rails    o year parts only  Gold  painted and special    finishes 3 years parts only  All subject to  proof of purchase      Labour provided by an approved Bristan  engineer  Guarantee only applies to products  with a manufacturing fault  A deferred  payment will be necessary in order to secure  any visits by our engineers which will be  charged if the problem Is found not to bea  manufacturing fault  If the fault is found to be  down to a manufacturing error  the payment  will be released and not charged     This guarantee applies to products purchased  within the United Kingdom or Republic of  Ireland  but does not apply to products used  commercially     The guarantee is only available to original  purchasers who have proof of purchase     The installation must allow ready access to all  products for the purpose of Inspection   main
11. ax  0844 701 6275    Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  31    Part Number  800446    Issue  Fl Opac Lever Range D1       Bristan Group Ltd    Birch Coppice Business Park  Dordon   Tamworth   Staffordshire   B78 1S6    Web  www bristan com  Email  enquireldbristan com    A Masco Company    
12. blesnooting    No flow when Inlet filter is partially blocked  Check insert filters for any  shower Is turned blockages and clean as necessary     on   Blocked or damaged check Remove check valve and clean      valve  replace If necessary     Air block in either   both Flush through supply pipework   Supplies    Piston sticking Remove thermostatic cartridge  and piston  Service shower valve   Refer to Maintenance section   pages 25 26      Pulsating flow Air block in either   both Flush through supply pipework   and   or varying supplies    temperature   Incorrect use of flow regulators   Check and remove   replace if  necessary     Flow rate too Flow regulators not fitted  Fit flow regulators    great   Shower valve will   Thermostatic a not Service shower valve  Refer to   not shut off  shutting off fully Maintenance section  pages 25 26   Fail safe not Shower valve requires Refer to Commissioning section  working  commissioning   page 18         Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  29    Guarantee    Bristan offers solid guarantees to provide  you with complete peace of mind     Taps and Mixers   o year parts and 1 year labour    Gold  painted and special finishes  3 years parts only     All subject to proof of purchase     Mixer Shower Valves   1 year parts  1 year labour   subject  to registration   or 1 year with proof of  purchase     Gold  painted and special finishes 3 years  parts only     Pumps and Power Showers  2 ye
13. e  installing a new cartridge  If this is the  case  screw the bottom cap fully  clockwise until It stops   then unscrew  anti clockwise 3 4 turn only and then  refer to the Flow Regulator table on  page 13 to see If any further  adjustments are required for your  particular system     e Replace sleeve  retaining ring and  the control knob and refer to  maximum temperature setting on  page 21     e After re setting your desired  maximum outlet temperature replace  the handle  tighten the grub screw  and push fit the cap back onto the  handle     26 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Hard Water Regions in the UK       Soft to  moderately soft   0   100mg l as  calcium carbonate  equivalent       Slightly hard to  moderately hard  100   200mg l as  calcium carbonate  equivalent       Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors               London area postcodes    Hard to very hard  Above 200mg l as  calcium carbonate  equivalent       BR EN NW TW WO  CR HA SE UB  E IG SM W    EC N    SW WC    27    Troublesnooting       Maximum water  temperature too  hot or cold    Outlet water  temperature too  hot   cold     Water  temperature too  cold   maximum  water  temperature  incorrectly set     Only hot or cold  water from  shower valve  outlet     28    Maximum water temperature  set incorrectly     Inlet filter is partially blocked     Installation conditions outside  operating parameter
14. enari te cde cosecs ccsetacen na e n a a a iaasa 2OOLO    Map of Hard Water Regions in the UK ou    cece 2   TOUDE NOOU aena erence mre a Nar ren ene enh re ere ere 28 29  FE Sd a eae cst a E E A E E 30 3   NG taal se ioa a a aa a a e a E AE S     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Important Safety Information       e Please read these Instructions thoroughly and retain for future use    e All products manufactured and supplied by Bristan are safe provided they are Installed   used correctly and receive regular maintenance In accordance with these Instructions    e This fitting needs to be Installed in accordance with  and meet the requirements of the  Water Supply  Water Fittings  Regulations 1999 and Scottish Byelaws 2004    e  f you are in any doubt about your ability to install this product safely you must   employ the services of an experienced qualified plumber    e Do not use If the showerhead or shower hose has been damaged or Is blocked    e Do not crush or kink the shower hose  this could damage the hose and cause leaks    e Remove all packaging and check the components for damage before starting  installation       AN Warning  Before starting any installation please consider the following  Prior to  drilling into walls  check that there are no hidden electrical wires  cables or water  supply pipes  This can be checked with the aid of an electronic detector    e  f power tools are used do not forget to    Wear eye
15. er and white  vinegar and allow to soak for a couple  of hours  If heavily scaled allow to  Soak overnight     e Replace all O    rings and seals  A  maintenance kit is available for your  mixer valve     Please visit   www bristan com sparesfinder in  order to find spare parts for this  product     e Only use a silicone based grease on  all O    rings and seals  light smear  only  and on the thread of the spindle  and spindle housing     Re Assembly    e Add P  T F E washer to spindle from  the splined end  then the O    ring  The  spindle is then screwed into the  Spindle housing  Locate this new  assembly into the head and fit the  circlip  Please note that the circlip  does not locate on the groove  immediately beneath the splines but  locates on the next one down towards  the threaded end     e Screw the head assembly onto the  half cartridge and tighten fully by  inserting flat tool into the slots and  use a suitable spanner on the  hexagonal part of the head to tighten     e Place the thermostat Into the piston  and place the spring Into the recess In  the bottom of the piston and  distributor assembly  use a dab of  grease to retain the spring in place      eOffer the piston assembly up to the  cartridge assembly ensuring that the  thermostat Is located in the centre of  the piston with the black wax end  facing out Into the centre of the  cartridge assembly     e Screw the complete assembly into  the valve body and tighten  Do not  adjust the bottom cap unless you ar
16. he temperature of the mixed  water at a smaller draw off flow rate   which shall be measured     If the mixed water temperature has  changed significantly from the previous test  results le g  gt 1 K    record the change and  before re adjusting the mixed water  temperature check     a  That any in line or integral strainers are  clean     b  Any in line or integral check valves or  other anti back siphonage devises are  in good working order     c  Any isolating valves are fully open     With an acceptable mixed water  temperature  complete the following  procedure     a  Record the temperature of the hot and  cold water supplies     b  Record the temperature of the mixed  water at the largest draw off flow rate    c  Record the temperature of the mixed  water at a smaller draw off flow rate   which shall be measured     d  Isolate the cold water supply to the  mixing valve and monitor the mixed  water temperature     e  Record the maximum temperature  achieved as a result of  d  and the final  stabilised temperature     f  Record the equipment  thermometer  etc  used for the measurements     If at step  e  the final mixed water  temperature Is greater than the values In  table 17 and   or the maximum  temperature exceeds the corresponding  value from the previous results by more  than about 2 K  the need for service work Is  indicated     Note  In service tests should be carried  out with a frequency  which identifies a  need for service work before an unsafe  water tempera
17. ice  test should be carried out at 18 to 21  weeks after commissioning     If significant changes  e g   gt  2 K  in  mixed water temperatures are recorded  in either of these periods  necessitating  service work  then the next In service  test should be carried out at 18 to 21  weeks after commissioning     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Maintenance    General Cleaning    Your fitting has a high quality finish  and should be treated with care to  preserve the visible surfaces  All  finishes will wear If not cleaned  correctly  The only safe way to clean  your product is to wipe with a soft  damp cloth  Stains can be removed  using washing up liquid  All bathroom  cleaning products  powders and  liquids  will damage the surface of  your fitting  even the non scratch  cleaners     Note  Never use abrasive detergents  or disinfectants or those containing  alcohol  hydrochloric acid or  phosphoric acid     Bristan recommend E   cloth for cleaning all of  our bathroom  amp  kitchen  products  Using just  water  E cloth gives a  smear free  deep clean by breaking up  and hold dirt  which normal cloths  leave behind  Order through your  Bristan stockist  order code  ECLOTH         Servicing    If your thermostatic mixer valve fails to  operate correctly it could be the result  of an incorrect installation  Please  refer to the installation section  amp  site  requirements     If the valve has operated correctly for  some time
18. itting shall be installed so that its outlet 3  Exceeding 3 4 in    discharges above the spill over level of  any fixed appliance as indicated below         For backflow protection in domestic or  installations up to  and including  Fluid  Category 3     If the fitting cannot be Installed as  Indicated in the table opposite It shall be  installed as either a or b below     a  with an approved double check valve  assembly or some other no less  effective backflow prevention device  Immediately upstream of the Inlet     b  so that it draws water by gravity only  from a cistern  or cylinder having a  permanently open vent pipe  and the  distributing pipe supplies no other fitting   other than draining tap  at a lower level     For backflow protection in premises or  installations up to  and including Fluid  Category 9     The vertical distance of the outlet above  the spill over level shall be not less than  20mm or twice the diameter of the inlet  pipe to the fitting  which ever is the  greater  If the fitting cannot be Installed  as Indicated It shall be installed with a  backflow prevention arrangement  Suitable for the Fluid Category     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  11    Installation Requirements       Conditions of use for Type 3  Thermostatic mixer  valves    In order to give compliance with N H S  specification DO8 the table below lists the  conditions for normal use  These valves will perform adequately outside the
19. ned advisors     Operation  amp  Temperature Setting       On Off and Temperature Control    Turn the control  1  anti clockwise to OP TS1503 ISOL C shown below  turn on and increase the temperature     Turn the control  1  clockwise to  decrease the temperature and turn off     The maximum temperature is factory  set to 43  C however this can be  adjusted to suit different site conditions   see below to re set maximum  temperature setting      Maximum Temperature Setting    The maximum blend temperature  should be limited to ensure that no  undesirable temperature Is obtained  If  adjustment Is necessary the following  Should be carried out        e Turn the control knob anti clockwise  so the shower is running at full flow  and is at the maximum temperature   allow the flow temperature to stablise  for afew minutes      e Remove the handle by prising out the  cap and removing the grub screw     e Slide a 2 9mm hexagonal key down  through the centre of the spindle and  turn the adjusting screw anti clockwise  for a warmer temperature and  clockwise for a cooler temperature     e When the desired maximum  temperature Is achieved replace the  control knob  tighten the grub screw  and push fit the cap back into the  handle     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  21    Commissioning       Commissioning notes for  Thermostatic Mixing Valves    The first step In commissioning a  thermostatic mixing valve is to check  the following  
20. o the underside of the cold tank should be    at least 1 metre to ensure adequate performance     Note  Nominally equal  balanced  inlet supply pressures are recommended for optimum    performance with mixer showers   This shower valve should be installed in compliance with Water Regulations     If in doubt  contact a registered plumber or you Local Water Authority or the Secretary of    The Institute of Plumbing  address as follows      The Institute of Plumbing   64 Station Lane   Hornchirch    Essex  RM12 6NB   Tel  01708 472791    Recommended Usage    Heavy       Light    4 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Product Features       1  On Off and Temperature Control  Turn the control anti clockwise  to turn the shower on and Increase    the temperature     Turn the control clockwise to  decrease the temperature and    to turn the shower off     2  Shower Outlet   Connects the shower hose to   the shower valve  If the top outlet   is to be used  use the blanking plug    to blank off the bottom outlet     3  Isolation Elbows   Designed for ease of maintenance  and servicing when the valve In  installed in a wall cavity    Supplied with OP 151903 ISOL C   OP 151503 CL C only     4  Concealing Shroud   Conceals exposed pipework   which is shown when the valve   is installed in a wall cavity    Supplied with OP TS1503 CL C model     9  Protective Shroud  Designed for use In healthcare     The protective shroud ensures       a 
21. olicy  Important     In the event of product or component malfunction  DO NOT tamper with or remove the product  from site  Telephone the Customer Services Department and be prepared with the date of  purchase  model number and a clear description of the complaint     Our service staff are fully qualified to advise on correct installation procedures and will be able  to diagnose whether the fault will require a replacement part or a visit from a Bristan engineer     If required  a service call will be booked and either yourself or an appointed representative  who  should be a person of 18 years or over  must be present during the visit     All site visits to products out of guarantee will be carried out free of any parts or labour charges  provided the conditions of the guarantee have been adhered to  the 2  to 5t year of the  guarantee is parts only  unless registered      All site visits to products out of guarantee will be subject to charges for parts and labour   Charges will also be levied on cancelled appointments  unless advised to Bristan at least 24  hours in advance of the agreed date and time     Should a product be discontinued  Spare parts stocks will be maintained  but in the event of a  part becoming unavailable Bristan reserve the right to supply a substitute of equal quality     In order to log an enquiry with us please visit http   www bristan com customerservice  Opening times  Please refer to the Bristan website     Customer Service  Tel  0844 701 6273 e F
22. r 1 0  5 0 bar   10 50 MTR  10 50 MTR  HEAD  HEAD     Gravity 0 1 0 2   White Orifice   bar  1 2 MTR  No washer Nothing  HEAD  required    Gravity 0 2 0 5 l   bar  2 5 MTR a Nothing  HEAD     Gravity 0 5 bar    5 MTR  HEAD    Green 7 Litre Yellow 5 Litre  Limiter Limiter        Green 7 Litre Yellow 5 Litre    Unvented hot Limiter Limiter  water storage    system    vere  shower coil      1 5 10 bar    Combi  boiler   Adjust Bottom  E Green 7 Litre Yellow 9 Litre Cap    1 2 turn    s water heater HOLEN SRE anti clockwise   Electric   Unvented     Yellow 5 Litre  Instantaneous Limiter  Heated    Adjust Bottom  Nothing Cap   1 2 turn  anti clockwise        Any vented   open outlet     heater  gas or Do not use with mixer valves   This would be    extremely dangerous    electric  e g      normal  electric  shower    Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  13    Flow Regulators       The table on page 13 shows the flow regulator requirements and valve adjustments for    various hot   cold supplies       Flow limiters are fitted and will be required to be removed when installed in low  pressure  gravity fed  applications below 1 0 bar  To remove  unscrew the retaining ring    and remove limiter and washer  Re fit elbows back to the body       With certain permutations of combi boiler hot supply and cold supply  it must not be  necessary to fit the yellow 9 litre flow limiter        The bottom cap is factory set at 3 4 turn from the fully
23. s     Hot water temperature Is less  than 10  C above the required  blend temperature     Instantaneous water heater not  igniting because water flow  rate is too low     Instantaneous water heater not  igniting because water  pressure Is too low     Inlet water supplies are  reversed  hot to cold supply      Inlet filter is partially blocked     Reset maximum water  temperature  Refer to Maximum  Temperature Setting In  Commissioning section  page 22   and Adjusting the Temperature    in  Operation  amp  Temperature setting  section  page 21     Check insert filters for any  blockages and clean as necessary     Refer to Installation Requirements  section  page 11 12     Service shower valve as  recommended  Refer to  Maintenance section  pages 25 26   Refer to Operation  amp  Temperature  Setting section  page 21      Adjust hot water temperature or  wait for water system to reheat If  stored system IS used     Increase water flow rate through  the system    Check cartridge inlet filters and  clean or replace  Refer to  Maintenance section  pages 25   26     Contact the boiler manufacturer     Increase water pressure through  system   Contact the boiler manufacturer     Check the connections are the  correct way round  Hot on the left  and cold on the right when viewed  from the front  Rework pipework  as necessary     Clean or replace  flush through  pipework before refitting        Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Trou
24. safe surface temperature   Supplied with OP 151503 SCL C model        Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  5    Specifications       Inlet Connections  15mm compression connections   OP 151503 EL C   148 158mm adjustable centres   OP 151503 CL C   175mm fixed centres    OP 151503 ISOL C   175mm fixed centres    OP 151503 SCL C   125 132mm adjustable centres     Outlet Connections  Top or bottom G  2  BSP male 15mm compression adaptor    Operating Pressure Range  Min  0 1 bar   Max  3 0 bar   Maximum recommended    imbalance between hot and cold supply should not exceed a ratio of 9 1   Maximum Static Pressure  10 0 bar    Maximum Outlet Temperature  Factory pre set to 43  C  can be re set to suit site  conditions   If the temperature is re set to suit different site conditions the valve will    work adequately however the TMV3 scheme will not apply     Supply Requirements    Minimum cold water supply temperature  5  C    Maximum cold water supply temperature  25  C    Maximum hot water supply temperature  80  C     a maximum hot water supply temperature of 60   80  C is recommended for ablutionary    purposes      Note  The inlet hot water temperature must be at least 10  C above the required blend    temperature  e g  shower temperature 43  C  minimum hot supply 53  C     Performance   Open Outlet     Flow Rates are In litres per minute at equal pressures    Pressure  bar  0 1   0 2 04   os   os 1 0    Eo Z0 0  I a0   ft a0    
25. se  parameters  however they cannot be guaranteed by the scheme to operate as Type 3  valves  If they are required to work with other supply conditions an engineer must carry  out a risk assessment and satisfy themselves that the valves are suitable for use     Normal Conditions of Use for Type 3 valves    Flow Pressure  Hot  amp  Cold  Bar  0 5 to 5 0 0 1 to 1 0    Hot Supply Temperature    C  5510765 55 to 65  Cold Supply Temperature    C  Equal to or Less than 25   Equal to or Less than 25    Minimum Temperature 5 6    This valve has been approved for use in the The BuildCert TMV scheme recommends  following designations  the following set maximum mixed water       outlet temperatures for use in all  premises     Operating Pressure   Application  44  C for Bath fill but see notes below   High Pressure 41  C for Washbasins   38  C for Bidets   eee sea The mixed water temperatures must    never exceed 46  C   LP   B Low Pressure Bidet  The maximum mixed water temperature  maximum set outlet temperatures   Key     HP   High Pressure LP   Low Pressure       Note  For wash basins  washing under  running water is assumed     12 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Flow Regulators    Fit to Elbows  Cold Supply Hot Supply Comments    0 1 to 1 0bar 0 1 1 0 bar Max ratio of Hot   1 to 10 MTR  1 10 MTR Nothing Nothing   Cold pressure  HEAD  HEAD  1 5  5 1            This  arrangement will  also suit pumped  systems      1 0 to 5 0 ba
26. sing a hexagonal key    Use the backplate as a template and mark  the centres of the fixing holes onto the  wall     A Warning  Please check for any hidden  pipes and cables before drilling holes in  the wall     Drill suitable holes and insert the wall  plugs  Securely attach the backplate to the  wall using the screws provided        Important  Water supplies to the mixer  must be with hot on the left and cold on  the right when views from the front       Pipework Centres    Cold     Fr    Ho    Backplate  48MM fixing holes   The pipework centres differ on both  Models     OP TS1503 EH C   Adjustable between  148 158mm    OP TS1503 ISOL C   Fixed centres of    170mm       Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  15    Installation cont        OP 151503 EH C  OP 151503 ISOL C continued    3  Attach shower valve  Place the shrouds over the water supply Re attach the shower valve to the  pipes  Insert the 15mm hot and cold water backplate by tightening the grub screw   Supply pipes Into the Inlet connections and   tighten the nuts  Ensure the olives and  filter are In place     Secure the shower valve to the backplate  by tightening the backplate grub screw            Backplate  grub screw    16 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Installation cont        OP TS1503 CL C  Concealed     Before Installation    Flush through the pipework to ensure Important  Water supplies to the mixer 
27. tenance or replacement     Any part found to be defective during the above  guarantee period will be replaced without  charge  providing that the product has been  installed In accordance with the Instructions   used as Intended  and regularly serviced     Servicing should be carried out at regular  intervals of no more than 12 months and more  frequently in hard water areas  heavy lime  scale  areas     In the unlikely event that any problems are  encountered with the products performance  on Installation  you must obtain  guidance authorisation from our Customer  Service Department  and be able to supply  proof and date of purchase  before any  remedial action Is taken     The guarantee excludes general wear and tear  and damage caused by accident  misuse or  neglect  and does not cover the following     30 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     Guarantee  amp  Service Policy       e Components that are subject to general wear and tear such as filters  seals  O  rings  and washers etc     e Damage caused by faulty Installation   e Damage caused by lime scale or any waterborne debris   e Damage caused by inappropriate cleaning products  see cleaning section   e Damage caused by the use of non Bristan parts    e  he product being used for a purpose other than Intended by the manufacturer     In the interests of continuous product improvement Bristan reserves the right to alter  Specification as necessary     Replacement Parts P
28. ture can result  In the  absence of any other instruction or  guidance  the procedure described In  Annex F of D 08 may be used     Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors  23    In Service Testing cont     Annex F of D 08  informative     Frequency of in service tests    General    In the absence of any other Instruction or  guidance on the means of determining the  appropriate frequency of In service testing   the following procedure may be used     a     b     6 to 8 weeks after commissioning carry  out the tests in In Service Tests        12 to 15 weeks after commissioning  carry out the tests detailed in In   Service Tests     Depending on the results of the above  tests  several possibilities exist     a     b     24    If no significant changes  e g   lt  1 K  in  mixed water temperatures are recorded  between commissioning and 6 to 8 week  testing  or between commissioning and  12 to 15 week testing the next In service  test can be deferred to 24 to 28 weeks  after commissioning     If small changes e g  1 to 2 K  in mixed  water temperatures are recorded In only  on of these periods  necessitating  adjustment of the mixed water  temperature  then the next In service  test can be deferred to 24 to 28 weeks  after commissioning     c     d        If small changes  e g  1 to 2 K  in mixed  water temperatures are recorded In  both of these periods  necessitating  adjustment of the mixed water  temperature  then the next in serv
29. viding the temperature of  the water seeping from the valve Is no more  that 2  C above the designated maximum  mixed water outlet temperature setting of  the valve     Temperature readings should be taken at  the normal flow rate after allowing for the  system to stabilise     The sensing part of the thermometer probe  must be fully submerged tn the water that  is to be tested     Any TMV that has been adjusted or serviced  must be re commissioned and re tested In  accordance with the Instructions in the  maintenance section     The installation of thermostatic mixing  valves must comply with the requirements  of the Water Supply  Water Fittings   Regulations 1999     22 Need help  Give us a call on 0844 701 6273 and speak to one of our trained advisors     In Service Testing       Purpose    The purpose of in service tests is to  regularly monitor and record the  performance of the thermostatic mixing  valve     Deterioration in performance can Indicate  the need for service work on the valve and    or water supplies     Procedure    Using the same measuring equipment or  equipment to the same specification as  used in the commissioning section  adjust  the temperature of the mixed water In  accordance with the manufactures  instructions and the requirement of the  application  Carry out the following  sequence     a  Record the temperature of the hot and  cold water supplies     b  Record the temperature of the mixed  water at the largest draw off flow rate     c  Record t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Aufbau- und Bedienungsanleitung ATS - Relax 2  Istruzioni ver.02  - V & V dei F.lli Verrocchio S.n.c.    AZ Patio Heaters HIL-6011 Instructions / Assembly  PDFファイル  TS0866 Four-Door Controller Installation Manual  MITHRIDATE - Bulletin dhistoire des poisons n 6  へんしん!ライダーα  Vision CS-1300 loudspeaker  AM/FM PROJECTION CLOCK RADIO USER MANUAL    Copyright © All rights reserved. 