Home

User's Guide - Data Loggers

image

Contents

1. TR 0306 Stainless Protection Sensor Cable Length 0 6m 2 i ane Thermal Constant Time i In agitated water Approx 18 Sec i D 3 X Only stainless section is water resistant TR 0406 Stainless Protection Sensor Cable Length 0 6m 7 Thermal Constant Time ipi In agitated water Approx 20 Sec f 1 G X Only stainless section is water resistant TR 0506 Stainless Protection Sensor Cable Length 0 6m f 293 600 i g Thermal Constant Time t Ho In agitated water Approx 20 Sec X Only stainless section is water resistant 22 TR 0706 Stainless Protection Sensor Cable Length 0 6m 14 s 600 td 15 S Thermal Constant Time In agitated water Approx 18 Sec X Only stainless section is water resistant E Wide Range Temperature Sensors for TR 71S Z CAUTION These sensors cannot be used with TR 72S TR 71 TR 72 Possible Measurement Range 60 to 155 C Sensor Temperature Durability 70 to 180 C Water Resistant Ability Splash Resistant Measurement Accuracy Average 0 5 C 40 to 80 C Average 1 0 C 60 to 40 80 to 100 C Average 2 0 C 100 to 155 C Materials Thermistor Stainless Pipe SUS316 3 Teflon Compaction Tube Teflon
2. Continuing to use the unit without changing the batteries will cause it to go into sleep mode From the time the BAT mark appears to the time the unit will go into sleep mode is roughly as below Please change the batteries before the unit goes into the sleep mode Recording interval of 2 sec or longer Approx 3 months Recording interval of 1 sec Approx 2 months 3 Continuing to use the unit with the BAT mark displayed and without changing the batteries will cause the display to change to SLP and the unit will enter sleep Please change the batteries immediately Recording stops and the recorded data and recording conditions are stored in the main unit Downloading data is only possible if you change the batteries To start recording again after replacing the batteries you must reset the Start Recording settings While replacing the batteries the main unit will continue to function for up to 1 hour without batteries From the time the unit enters sleep mode until battery power is totally lost is about 1 year 4 If left in sleep mode the battery power will be lost and the display will turn off Recorded data and recording conditions will be lost from the main unit To start recording again after replacing the batteries you must reset the Start Recording and Recording Conditions settings 14 LCD Display al COM o AOC ror T Calla O Di
3. The following settings can also will be made gt For more details see the Thermo Recorder for Windows User s Manual or the HELP menu of the software E Recording Start Stop Start and Stop the Recording via the Software Z CAUTION By starting a new recording or by making new recording conditions recorded data stored in the main unit will be erased Be sure to download and save any necessary recorded data left in main unit before making new settings E Set Recording Conditions Recording Conditions such as Record Starting Date Interval Recording Mode and Temperature Unit of Display C F can be set or changed easily via your computer In Recording Mode you can select from two recording methods One Time Method One Time Method Recording stops when 8 000 data readings have been recorded and FULL is indicated on the LCD The estimated time to reach FULL can be calculated with the following formula EX A 30 second recording interval x 8 000 readings Maximum readings that the unit can record 240 000 seconds Approx 2 days 18 hours and 40 minutes Endless Loop Method When 8 000 readings have been recorded the oldest data is overwritten and recording continues E Set Up Procedure 1 Connect the serial port of your computer and the main unit through the standard communication cable Connect the cable to a serial port which has the following mark TL lolol Z CAUTION Make sure to f
4. This symbol denotes a forbidden action Inside or near the S symbol will appear another symbol giving details EX stands for DO NOT TAKE APART This symbol denotes an action that you must take Inside or near the symbol will appear another symbol giving details EX stands for BE SURE TO FOLLOW ES A DANGER B ME A caution Do not take apart repair or modify the main unit It may cause fire electrocution or damage Please ask the shop where you bought the product or T amp D to carry out any repairs If any smoke or strange smells are emitted from the unit immediately cease using it Continued use may cause fire electrocution or damage If water or a foreign body enters the case immediately cease using it Continued use may cause fire electrocution or damage Make sure to use only power sources compatible with this unit The use of the wrong voltage may cause fire electrocution or damage It is dangerous to swallow batteries Store all batteries sensors and Thermo Recorder units out of the reach of children This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly gt e o e e We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the malfunction
5. for each channel Zoom in and out of graph data Display data for two points on graph and differences in measurements for those points Select calculation range and calculate highest lowest and average values for that range Select and set precise recording start date and time Change channel names Change channel order Merge channels Delete channels Change graph background color line color and line width Create data tables Print out graphs and tables Create and export data in Text file format Save data files gt For more details about these functions and operation of the software see Thermo Recorder for Windows User s Manual or the HELP menu of the software 21 Optional Sensors List E Temperature Sensors for TR 7 Series Possible Measurement Range 40 to 110 C Sensor Temperature Durability 50 to 115 C Measurement Accuracy Average 0 3 C 20 to 80 C Average 0 5 C 40 to 20 80 to 110 C Materials Thermistor TPE resin shielded sensor TPE resin shielded wire M3 Screw Hole Compaction Tube Stainless Pipe SUS304 Stainless Pipe SUS316 TR 0106 TPE resin Shielded Sensor All dimensions in mm Cable Length 0 6m inl a Thermal Constant Time j rnp In the Air Approx 75 Sec TR 0206 Stainless Protection Sensor Cable Length 0 6m Thermal Constant Time 5 In the Air Approx 75 Sec ORO 50 600
6. if a repairperson must be sent out to the place of use for repair If you have moved after purchasing or the product was received as a gift or there are some difficulties contacting the shop from which you purchased the unit please contact us directly for service Free repair is not available in the following cases even though it is within the warranty period 1 Trouble or damage was caused by careless operation natural disaster fire public pollution or use of a power source other than specified 2 If repair adjustment disassembly or modification of the unit has been carried out by a person other than a T amp D authorized engineer 3 Trouble or damage was caused by transportation movement or dropping of the unit after purchase 4 Failure to submit the Warranty or failure to fill in all items required in the Warranty The Warranty cannot be reissued This Warranty only promises customers free repair within the period and conditions clarified in this Warranty Therefore the customer s legal rights will not be limited by this Warranty For further information on repair and others service questions after the termination of the warranty period contact your dealer 26 T amp D CORPORATION 5652 169 Sasaga Matsumoto City NAGANO 399 0033 JAPAN Phone 81 263 27 2131 Facsimile 81 263 26 4281 Homepage http www tandd co jp english E Mail overseas tandd co jp
7. 0 Humidity and Temperature Sensor 49 B o o e 0g Mg ro od gt E Sensor Extension Cable TR 1C30 Sensor Extension Cable All dimensions in mm Cable Length 3m 3000 Materials Vinyl Chloride Coated Wire A CAUTION Cannot be used with Temperature Humidity sensor Use only one extension cable per temperature sensor 24 Product Specifications Unit TR 71S TR 72S Measurement Channel 2 Channel Select from Internal or External 2 Channel Temperature and Humidity Measurement Item Temperature Only Temperature Humidity Internal Sensor 10 to 60 C 10 to 60 C External Sensor 40 to 110 C 0 to 50 C 10 to 95 RH Optional Sensor 60 to 155C X1 40 to 110 C Measurement Accuracy Standard Sensor Average 0 3 C 20 to 80 C Average 0 5 C 40 to 20 80 to 110 C 5 RH at 25 C and 50 RH Measurement 7 5 Resolution Display 0 1 C 1 RH Sensor Materials Thermistor Polymer Recording Intervals 1 2 5 10 15 20 30 Secon 1 2 5 10 15 20 30 60 Minutes Total ds of 15 choices Recording Capacity 8000 Readings X 2 Channels Recording Mode Endless Loop Method One time Method Current Temperature Recording Settings Battery Life Warning LCD Display Exceed Measurement Range Warning Readin
8. 6 Standard Software Thermo Recorder for Windows x 1 set User s Guide and Warranty Software User s Guide x 1 set Part Names and Functions E Front View Built in Temperature Sensor Channel 1 ml Thermo Recorder HULL gt TR 718 chi ch 2 MIN SEC AN POWER ANDES 2 Q TA a REC STOP button INTERVAL button Set Recording Interval E Left Side View Power Switch E Right Side View Start and Stop Recording Sensor Connection Jack O Channel 1 Q fe Sensor Connection Jack a Channel 2 Available only for TR 71S r Communication Cable Connection Jack Connect the Sensors Connecting the standard sensors to the main units gt Optional temperature sensors can be used For details see page 22 Optional Sensors List E TR 71S Standard Temperature Sensors TR 0106 OO Connection condition Channel 1 Channel 2 Both are unconnected Internal Sensor Ch 1 is connected External Sensor Ch 2 is connected Internal Sensor External Sensor Ch 1 and 2 are connected External Sensor External Sensor E TR 72S Standard Temperature Humidity Sensor TR 3110 Thermo Recorder RALLY Connection condition Channel 1 Channel 2 Temp Humidity sensor con
9. Resin FEP Shielded TR 1106 Teflon Shielded Sensor Cable Length 0 6m 600 Thermal Constant Time All dimensions in mm 22 J In the Air Approx 15 Sec T 4 4 In agitated water Approx 2 Sec a TR 1220 Stainless Protection Sensor Cable Length 2m 185 0 2000 Thermal Constant Time z j In the Air Approx 36 Sec f o p oe In agitated water Approx 7 Sec TR 1320 Stainless Protection Sensor Cable Length 2m 70 0 2000 Thermal Constant Time 3 In the Air Approx 12 Sec b bed d UUE In agitated water Approx 2 Sec 23 E Temperature and Humidity Sensors for TR 72S TR 72 Humidity Measurement Range Temperature Measurement Range Sensor Durability Range Humidity Measurement Accuracy Service Life Operational Conditions 10 to 95 0 to 50 C 10 to 55 C 5 RH at 25 C and 50 RH 1 year under normal conditions No Dew Condensation or Water Leakage No contact with organic solvents solution or gasses emitted from spoiled foods Materials Temperature Humidity Sensor Polypropylene 3 Vinyl Chloride Coated Wire All dimensions in mm TR 3110 Humidity and Temperature Sensor Cable Length 1m 52 1000 lt L Tr r 6 noo TR 310
10. Thermo Recorder TR 71S TR 72S User s Guide Carefully read and fully understand instructions before using this unit Copyright 1998 2002 T amp D CORPORATION All rights reserved 2002 04 16004104060 E Notices about this User s Guide Carefully read and fully understand these instructions before using this unit All rights of this User s Guide belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Guide without the permission of T amp D Corporation Please follow the safety precautions carefully We cannot guarantee nor or we responsible for safety if this product is used in any manner other than was intended T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair of the attached warranty T amp D Corporation accepts no responsibility for any results or effects from using this User s Guide This User s Guide cannot be reissued so please keep it in a safe place On screen messages in this manual may vary slightly from the actual messages Figures and illustrations in this manual may be slightly simplified and may differ from the actual product Specifications design and other contents are subject to change without notice Please notify the sh
11. and Table iof CONIEN S aseeseensa Eanna 7 humidity on its other channel The recorded data from either unit can be downloaded to your computer via the included software Thermo Recorder Getting Ready for Windows where you can use the software to create colorful graphs Outline of the Product 8 tables export text files as well manage files and control printing Part Names and Functions 9 E Contents of Package Connect the Sensors 10 Thermo Recorder AEE Temperature and Humidity Sensors TR 72S 11 Install Batteries and Turn Power On 12 o Battery Ljf ccninsein naaa 13 TR 71S LOD Display aieeaii eanas esa iSe E i 15 a a ex Basic Usage Standard Temperature Sensors Temperature Humidity Sensor Start Recording and TR 0106 x 2 TR 3110 x 1 Set Recording Interval via Main Unit 16 Accessories Both TR 71S and TR 72S Start Recording and Set Recording Conditions via Computer a j i Mm i J Display Amount of Recorded Data Collecting Recorded Datta c ccccsccssescessesteeeeteesees 21 AAA Alkaline Batteries LRO3 Communication Cable x2 RS 232C D Sub 9Pin Other Cable Length 1 5m x 1 Optional Sensors List veces dit cwiacn cuits 22 Product Specification cccciccccscirscccsinannannnccrcecenntcisna 25 Provisions for Free Repair c eee eee 2
12. g Capacity Unit of Temperature Battery AAA Alkaline Batteries x 2 Battery Life Approximately 1 year X 2 Data Back up Low Battery Power Switched OFF Interface Serial Communication RS 232C Communication Speed Download at 9 600 bps 50 Sec per Unit when data is full Dimensions H55mm x W88mm x D24mm Weight 95g Including AAA Alkaline Batteries x 2 Temp and Humidity Durability of the Unit Temperature 10 to 60 C Humidity Less than 90 RH Without dew condensation Standard Sensors TR 0106 x 2 TR 3110 x 1 Accessories AAA Alkaline Batteries LRO3 x 2 Communication Cable RS 232C D Sub9 pins cable length 1 5m x 1 Standard Software x 1 set User s Guide x 1 set X1 There are 2 types of temperature sensors covering different ranges for use with the TR 71S For details see page 22 Optional Sensors List X2 Battery life differs depending on measurement environment and battery performance Changing the battery is possible even during recording 25 Provisions for Free Repair 5 If the unit does not work properly despite the fact that the customer used it properly and in line with the User s Guide the unit shall be repaired free of charge through the agent which sold the unit If the customer requests free repair because of trouble within the warranty period bring or send the unit along with the warranty to the dealer A service charge may be added
13. nected External Temp External Humidity No external sensor connected Internal Temp Temperature sensor connected External Temp 10 Temperature and Humidity Sensors A Caution The replacement period for the standard sensor is 1 year Replace it when 1 year has passed after opening the bag When using the Temperature and Humidity Sensor the surface can become dirty and may decrease its sensitivity and accuracy Therefore if the unit is being used in a dusty or smoky environment it may be necessary to change the sensor sooner than usual The accuracy of the sensor may decrease even within 1 year if it is used kept outside the specified operation conditions When the sensor is not used put it in the attached plastic bag with a drying agent and keep it in a cool dark place at 5 to 25 C and 30 RH or less Two types of sensor seals are pasted on the sensor If the seal shows abnormality appears red replace the sensor as soon as possible E Sensor Seal Details Water Leakage Sensor Seal Normal White Abnormal Red fi The seal turns red in an abnormal state This indicates that the sensor has gotten wet Temperature Sensor Seal Normal White Abnormal Red 2 The seal turns red in an abnormal state and the figure 60 is displayed This indicates that the sensor was exposed to a temperature of 60 C or more 11 Install Batteries and T
14. of our unit Please be fully aware of this before using our product The Thermo Recorder is a device to measure temperature Do not use this unit for any purpose other than temperature measurement Do not apply sensors to the human body Do not put your fingers or foreign matter into the communication port Use these units under conditions with an ambient temperature of 10 to 60 C and humidity of 90 RH or less OOP Do not use or store the unit in places such as listed below In places exposed to splashing water In the direct sun light or in excessively hot and humid places In excessively smoky dusty or steamy places In areas exposed to harmful chemicals or gases In areas exposed to strong magnetic fields Do not drop the unit place heavy weight on the unit nor expose the unit to a strong impact Doing so may cause damage to the unit ES A CAUTION ES A CAUTION E TR 0106 Standard Temperature Sensor of TR 71S A Remove batteries from any unit that is not to be used for a long period of time Batteries left in a unit not being used for a long time may leak and cause a malfunction A Battery life depends on the measurement environment communication frequency recording interval and battery quality Approximate battery life of 1 year is a standard of battery life under use with a recording interval setting at 2 seconds or more and in no way do we guarantee a battery
15. op where you purchased this product or T amp D Corporation of any mistakes errors or unclarities in this manual Microsoft Windows and WindowsNT are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company Teflon is a registered trademark of the Dupont Corporation and of the Mitsui Dupont Fluro chemical Corporation Published by T amp D Corporation 1st Edition April 2002 Copyright 1998 2002 T amp D Corporation All rights reserved Safety Precautions and Instructions In an attempt to ensure safe operation of our products and to protect them from the possibility of damage throughout this User s Guide the following symbols are used to indicate important warnings cautions and notices Please be sure to read understand and follow the contents of all such warnings E Explanation of Warning Symbols These entries are actions that absolutely under no circumstance should be taken The taking of DANGER such an action may cause serious personal physical damage or death These entries are actions that if taken may lead N caution to physical injury or damage to persons or things E Explanation of Picture Symbols This symbol denotes an important warning or caution A Inside or near the symbol will appear another symbol giving details EX stands for INFLAMMABLE
16. or until REC appears on the LCD and recording starts If the unit is set for Endless Method LOOP will be displayed on the LCD before REC appears E Stop Recording 1 Press down on the REC STOP button until the REC mark disappears from the display about 3 seconds and recording will be stopped 16 Set Recording Interval Z CAUTION The Recording Interval cannot be set or changed during recording and or during wait for a programmed start 1 Press down on the INTERVAL button for about 3 seconds or until the measurement value display changes to the Recording Interval display Release the button EX Recording interval is 15 seconds Recording interval is 15 minutes If during recording or while waiting for a programmed recording to start the INTERVAL button is pressed down for 3 seconds or more the present recording interval setting will be displayed Upon releasing the button the measurement display will return 2 Select the desired recording interval by pressing the INTERVAL button The interval will change each time you press on the button 3 Stop pressing the button when the desired recording interval has been reached When the display returns to the measurement value display the interval setting will be completed 17 Start Recording and Set Recording Conditions via Computer Start Recording and Recording Conditions can be set via your computer by using the software Thermo Recorder for Windows
17. s life Recorded data and recording settings will be lost if the batteries run out It is recommended that the batteries be replaced before they run out Q Use the sensor only within the measurable temperature range 40 to 110 C A For extending the temperature sensor cable use of only 1 extension cable is advised E TR 3110 Standard Humidity Sensor of TR 72S Use the sensor only within the measurable temperature and humidity range Temperature 0 to 50 C Humidity 10 to 95 RH Battery terminals may provide insufficient contact due to age or vibration Please be careful not to lose data due to insufficient contact The unit may give an error in humidity value if there is a rapid change of temperature However the value will return to normal after the sensor temperature stabilizes When the sensor is not used put it in the attached plastic bag with a drying agent and keep it in a cool dark place at 5 to 25 C and 30 RH or less A Q A An extension cable cannot be used with the Temperature Humidity Sensor Outline of the Product E Outline Table of Contents Introduction Thermo Recorder TR 71S is a 2 channel data logger unit designed to Notices about this User s Guide essere 1 measure display and record temperature The TR 72S is a data logger Safety Precautions and Instructions seesee 2 designed to measure display and record temperature on 1 channel
18. splays alternately channel number of present reading Displayed during recording flashes when waiting to start programmed recording Indicates amount of data recorded Indicates communication is occurring with computer Indicates when measurement is above or below the limit Vv is displayed for 40 60 C or less and A for 110 155 C or more X Figures in show the usage of TR 71S wide range temperature sensor Indicates battery life warning displayed when battery power becomes low Displays unit of temperature Can be changed between Celsius and Fahrenheit via computer Humidity unit display is only for TR 72S Displays alternately Present Temperature or Humidity for each channel 15 Start Recording and Set Recording Interval via Main Unit Recording can be started and interval settings made via the buttons on the main unit gt Only Recording Start Stop and Recording Interval can be controlled by using the main unit buttons Other settings such as Temperature Unit of Display C F and Recording Mode can only be made via computer See page 18 Start Recording and Set Recording Conditions via Computer for more details Start Recording Z caution Once a new recording starts all the recorded data in the main unit is erased Pressing the REC STOP even during waiting for a programmed start will start recording immediately 1 Press the REC STOP Button for more than 3 seconds
19. ully insert the connector to secure a proper connection Connecting to a wrong port will result in communication failure TR 71S TR 72S Computer Connect Connect ooc T gt Communication Cable D Sub9 Pin D Sub9 Pin Female Male RS 232C 2 Open Thermo Recorder for Windows on your computer and make settings such as Start Recording and other Recording Conditions gt For more details see Thermo Recorder for Windows User s Manual or the HELP menu of the software 19 Display Amount of Recorded Data Amount of recorded data stored in the main unit will be displayed on the LCD After Recording Mode As Recorded Data Increases Reaching Max One time al gt I Method P a gt dl call FULL V V Endless Loop VI V Method yi aal ga l atl JIN JIN JIN in One Time Method the display will read FULL when it reaches capacity and recording will stop in Endless Loop Method when it reaches capacity the indication will remain the same but recording will continue 20 Collecting Recorded Data With our exclusive software Thermo Recorder for Windows it is possible to download all of the recorded data from TR 71S and TR 72S as well as carry out the following functions in managing the data Display 8 channels of data in colorful graphs Control Display ON OFF
20. urn Power On E Battery Installation 1 Open the battery cover on the backside of the main unit 2 Install 2 AAA size alkaline batteries in the correct direction to align and A Caution install 2 new batteries Avoid mixing old and new batteries Sometimes after installing new batteries nothing will appear on the display for about 3 seconds this is not a malfunction 3 gt Close the battery cover E Turn Power On 1 Turn ON the power switch on the left side of the unit O OQ F Power Switch gt If during recording the switch is turned OFF recording will stop and all recorded data will be stored in the main unit 12 Battery Life 1 13 Approximate time till BAT mark appears on the LCD display after installing a new set of batteries is as follows Recording interval of 2 sec or longer Approx 10 months Recording interval of 1 sec Approx 6 months When the battery power becomes low the BAT mark will appear on the LCD display on the main unit Once the BAT mark appears you should replace the batteries as soon as possible BAT Recording will continue and the recorded data and recording conditions will be stored in the main unit You can still download the data to your computer Recording will continue while you replace the batteries The main unit will remain operating without batteries during replacement for up to 3 minutes

Download Pdf Manuals

image

Related Search

Related Contents

Família Sensor Light - 02  LED TV - Allrent  SIG aplicados a Construcciones Civiles  Proctor Silex 32700Y Use and Care Manual  Bedienungsanleitung  Sitecom CMPSC-WL061  Siemens Gigaset DE900 IP PRO User Manual  Guida alle funzioni - Instructions Manuals  コーヒーメーカー 取扱説明書 保証書  

Copyright © All rights reserved.
Failed to retrieve file