Operating Instructions Model: JG STATPLUS/TS/V3
Contents
1. Support Tel 01254 870303
2. Press Done to accept and store 8 Comfort Levels Explained Comfort levels allow you to set different temperatures throughout the day For example you may want the home warm in the morning when you are getting ready for work cooler during the day when the house is unoccupied and then warmer in the evening when you are home relaxing The thermostat offers 5 2 Day Programming 4 levels for the weekday 4 for the weekend and 7 day Programming 4 levels for each day See pages 19 23 for details on how to switch between these modes Tip If you don t want to use all of the comfort levels just set the time to the thermostat will ignore this setting Factory Programmed Comfort Levels The following comfort levels are programmed already however you can change them easily Weekday Level Time Temp Wake 07 00 21 C Leave 09 00 16 C Return 16 00 21 C Sleep 22 00 16 C Weekend Level Time Temp Wake 09 00 21 C Leave 22 00 16 C Return C Sleep C 10 Changing the Comfort Levels Press PROG and select Wake Use OA to set the time for the 1st Comfort level Use OA to set the temperature in C You should now repeat for the Leave Return amp Sleep levels Press Day to select the next day In 5 2 day mode the thermostat will highlight Sat Sun prompting you to program the temperature levels for the weekend In 7 day mode the thermostat will highlight Tuesday When complete press Done t
3. Operating Instructions Model JG STATPLUS TS V3 10 09 Revision Ref JGSTATPLUS TS V3 amp PlumbNation the nation s favourite for v FREE SHIPPING v SECURE PAYMENTS on all orders over 100 to mainland UK shop online with confidence v FINANCE AVAILABLE v PRICE MATCH spread the cost with low interest rates always get the best deals available we have HUGE REDUCTIONS ON THOUSANDS OF ITEMS Boilers Bathroom suites a an aa a 33 on eeu duum Pipes amp fittings Wet rooms Cylinders Towel warmers Fires 000 Bathroom furniture Renewable energy amp much more C un visit our website 2 7 plumbnation co uk 0844 800 3460 Contents Page Display Symbols Explained 7 Temperature Display 8 Setting the Clock 8 Comfort Levels Explained 9 11 Setting the Hotwater Switching Times 12 13 Locking the Keypad 13 Temperature Override 14 Temperature Hold 14 Howater Override 15 Holiday 16 Heat On Off 17 Clean Screen 17 Factory Reset 18 Optional Feature Setup 19 23 Wiring Diagrams 24 25 1 What is programmable room thermostat programmable room thermostat is both programmer and a room thermostat programmer allows you to set and Off time periods to suit your own lifestyle room thermostat works by sensing the air temperature switching on the heating when the air temperature fall
4. e factory defaults 18 THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED NOT BE ADJUSTED Optional Features Explained Feature 01 Temperature Format This function allows you to select between C or F Feature 02 Switching Differential This function allows you to increase the switching differential of the thermostat The default is 1 C which means the thermostat will switch the heating on 0 5 C below the set temperature and will turn it off 0 5 C above the set temperature With a 2 C differential the heating will switch on 1 5 C below the set temperature and will switch off 0 5 C above the set temperature Feature 03 Frost Protect You can set whether the thermostat will maintain the frost temperature when the thermostat display is turned off As a default this is enabled 19 Feature 04 Frost Protect Temperature This is the temperature maintained when the thermostat is in frost mode The range is 07 17 C The default is 12 C and is suitable for almost all applications Feature 05 Output Delay To prevent rapid switching output delay can be entered This can be set from 00 15 minutes The default is 00 which means there is no delay Feature 06 Communication Address This setting is used when you have connected your thermostat to a network system Each thermostat on the network must have a unique communication address This can be set from 01 32 Feature 07 Temperature Up Down Limi
5. h mount a back box of 35mm should have been sunk in the wall prior to installation Step 1 Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver in to the slots on the bottom face of the thermostat 5 Step 2 Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat Place the thermostat front half somewhere safe Terminate the thermostat as shown in the diagrams at the back of this booklet Screw the thermostat back plate on to the back box Step 3 Re connect the thermostat ribbon cable and clip the two halves together Display Symbols Explained Symbol Description Heat On Icon D Shown when the heating is On Flashing When the optimum start is in operation HW ON HW ON HW OFF HW OFF Shown to indicate whether the hot water output is on or off Frost On Icon Heating Off Shown when the heating is switched off and is protecting against frost only Keylock Icon Shown when the keypad is locked Temperature Display Room Temp This is the current room temperature SET This is the temperature you are trying to achieve in your home HW ON HW OFF This is the status of the hot water Setting The Clock To set the clock in your thermostat follow the steps below With the thermostat turned on press PROG Press Clock Use set the correct Time Press Day to set the correct Day
6. ill count the next day Tuesday as the holiday The thermostat will then revert back to its program at midnight Tuesday e Press HOLIDAY e Enter the duration of your holiday e Press Done e To cancel a Holiday reduce the Holiday time to 00 days During a holiday program the hot water output is turned off 16 Heat On Off Frost Protect Mode Pressing the Off button once will place the thermostat in frost protect mode In this mode the thermostat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature see pages 19 23 Should the heating be turned on whilst in frost mode the flame symbol will be displayed To cancel the frost protect mode press the On button Thermostat Off To turn the thermostat off completely press and hold the Off button The display and heating output will be turned off To turn the thermostat back on press the On button Clean Screen Pressing Clean Screen will disable all buttons allowing you 30 seconds to wipe the screen clean 17 Factory Reset The thermostat has a factory reset function This will reset all settings back to their factory default To perform a factory reset follow these steps Turn off the thermostat by pressing the off button Press and hold the bottom left corner of the LCD for 10 seconds You will see all the icons appear for 2 seconds and then disappear The thermostat has then been reset to th
7. llows you to adjust the set temperature When you press either of these keys you will see the word SET and the desired temperature Press Done to accept This set temperature is temporary and is held until the next programmed comfort level Temperature Hold The Temperature Hold function is ideal for parties or when you will be going out for a number of hours allows you to hold a temperature for a desired period Press HOLD Setthe desired Hold time and temperature Press Done To cancel a Hold time reduce the time to 00 00 14 Hot Water Override The thermostat has an override function for the hot water output allowing you to override the hotwater into the opposite state Press Hold Press Timer If the hotwater is already On press Off If the hotwater is already Off press You will then see the hotwater status change and the hotwater output indication will flash to show it has been overridden from the programmed setting The hotwater will remain in the override state until the next programmed time To cancel repeat the steps above 15 Holiday The Holiday function reduces the set temperature in your home to the frost temperature setting The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return Assume you program a holiday on Monday for 1 day the holiday will start immediately but the thermostat w
8. o Store and Exit 11 Hot Water Timings Explained The JGSTATPLUS TS V3 offers an additional timed output for the hot water cylinder The thermostat offers 5 2 Day Programming 4 levels for the weekday 4 for the weekend and 7 day Programming 4 levels for each day See pages 19 23 for details on how to switch between these modes Factory Programmed Hot Water Times The following hot water switching times are programmed already however you can change them easily Weekday On Time Off Time Wake 07 00 09 00 Leave 16 00 20 00 Return Sleep Weekend Time Temp Wake 07 00 09 00 Leave 16 00 20 00 Return Sleep 12 Changing the Hot Water Times Press PROG and select Timer You will see TIME 1 and ON flash Use to set the on time for the 1st switching time Press Off and then use to set the off switching time You should now repeat for the Time 2 4 Press Day to select the next day In 5 2 day mode the thermostat will highlight Sat Sun prompting you to program the switching times for the weekend In 7 day mode the thermostat will highlight Tuesday When complete press Done to Store and Exit Locking the Keypad The thermostat has a keylock facility To enable this press the bottom right corner of the display and hold for 10 seconds When activated you will see fi To cancel repeat the steps above 13 Temperature Override Using the v a keys a
9. s below the thermostat setting and switching it off once this set temperature has been reached So a programmable room thermostat lets you choose what times you want the heating to be on and what temperature it should reach while it is on It will allow you to select different temperatures in your home at different times of the day and days of the week to meet your particular needs Turning a programmable room thermostat to a higher setting will not make the room heat up any faster How quickly the room heats up depends on the design of the heating system for example the size of the boiler and radiators Neither does the setting affect how quickly the room cools 2 down Turning programmable room thermostat to lower setting will result in the room being controlled at a lower temperature and saves energy The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen and then leave it alone to do its job The best way to do this is to set low temperatures first say 18 C and then turn them up by one degree each day until you are comfortable with the temperatures You won t have to adjust the thermostat further Any adjustment above these setting will waste energy and cost you more money If your heating system is a boiler with radiators there will usually be only one programmable room thermostat to control the
10. t This function allows you to limit the use of the up and down temperature arrow keys This limit is also applicable when the thermostat is locked and so allows you to give others limited control over the heating system Feature 08 Sensor Selection This thermostat has a built in air sensor only 20 Feature 09 Floor Limit Sensor This function is not used on this model Feature 10 Optimum Start Optimum start will bring the heating on early if needed so the house is warm when you wake up This means you don t need to allow any extra heat up time when programming the comfort levels The thermostat will automatically learn the required heat up time and will adjust itself if required throughout the year Feature 11 Rate Of Change This is the number of minutes the thermostat has calculated it takes to raise your building 1 C The thermostat will continue to learn the heat up time of your home and will adjust this setting to suit Feature 12 5 2 Day 7 Day Programmable This function allows you to switch between 5 2 day or 7 day programming 5 2 day means you can program 4 comfort levels for the weekday and 4 different levels for the weekend 7 day programming allows you to program 4 temperature levels for each day of the week 21 Adjusting the Optional Settings To adjust the settings follow these steps e With the thermostat turned on e Press PROG e Press SETUP e Use the at the top of the screen to select
11. the feature number shown on page 23 and then use the keys in the centre adjust the setting Press Doneto accept and Store 22 Feature Table Feature Description Setting 01 Temperature Format 02 Switching 01 1 C 02 2 C 3 3 Differential 1 C Default 03 Frost Protect 00 Disabled 01 Enabled 01 Default 04 Frost Temp 07 17 C 12 Default 05 Output Delay Enter value 00 15 minutes 00 Default 06 Comms Enter number 01 32 07 Temp Limit 00 10 C 10 Optimum Start 00 Disabled Default 01 01hr 02 02hr 03 03hr 11 Rate of Change For information only 12 5 2 Day 00 Default 7 Day 01 23 JGSTATPLUS TS V3 Model THE JGSTATPLUS TS V3 RECOMMENDATIONS CONN CTED TO MAX CABLE SIZE 1 5mm TOUGH SCREEN MAX LOAD 3 AMP BACK BOX DEPTH 35MM WATER HEATING 9 v 90 IMPORTANT USE SHIELDED CABLE BELDEN 9538 OR CAT5e FTP UH1 ae WIS T JGSTATPLUS TS V3 Model THE JGSTATPLUS TS V3 RECOMMENDATIONS MAX CABLE SIZE 1 5mm TOUCH SCREEN MAX LOAD AMP BACK BOX DEPTH 35MM WATER HEATING B B2 B1 1 2 1 12V GND RS485 COMMS LINE T tl Y IMPORTANT TO TR2 NETMONITOR PC ADAPTOR water HEAT USE SHIELDED CABLE BELDEN 9538 SWITCHED OR OUTPUTS 5 FTP 25
12. whole house But you can have different temperatures in individual rooms by installing thermostatic radiator valves TRVs on individual radiators If you don t have TRVs you should choose a temperature that is reasonable for the whole house If you do have TRVs you 3 choose a slightly higher setting to make sure that even the coldest room is comfortable then prevent any overheating in other rooms by adjusting the TRVs The time on the programmer must be correct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to temporarily adjust the heating programme for example Override Advance or Boost These are explained in the manufacturer s instructions Programmable room thermostats need a free flow of air to sense the temperature so they must not be covered by curtains or blocked by furniture Nearby electric fires televisions wall or table lamps may prevent the thermostat from working properly Installation Procedure DO s 1 Do mount the thermostat at eye level 2 Do read the instructions fully so that you get the best from our product DON Ts 1 Do not install near a direct heat source as this will affect the workings of the thermostat 2 Do not push hard on the LCD otherwise you will damage the liquid crystal display and this is not repairable Installation The thermostat is designed to be flus