Home
Magnum CS14 & CSN14 Converter Switch Installation and User Guide
Contents
1. International Pi models Outdoor temperature rated Input IEC 320 connector on the 95 260vac 47 63Hz external power adapter Requires a user supplied power cord Output 12vdc 2Amps CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Direct DC POWER SUPPLY built in terminal block for ground along with 12VDC jack a 12V DC internal range of 8 0 to 15V DC se 24V DC internal range of 18 to 36V DC 48V DC internal range of 36 to 60V DC ground ae Power Consumption 3 watts typical and 4 watts max for all models Note 1 8 15V DC can be used for dual source DC input Note 2 Internal DC power floats user may ground or if desired Port Connectors RJ 45 Port Auto cross MDIX IOOBASE TX and 10BASE T shielded 8 pin female Three RJ 45 ports provided in front and one on the rear Supports shielded STP and unshielded UTP Cat 3 4 5 cable For POE pass through option on H and P models request quote CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Switches Fiber Port 1 is controlled by an F H switch provided underneath port F enables Full duplex to the fiber port 1 H enables Half duplex to the fiber port 1 LED Indicators Dual front and end POWER Steady On when power applied 10 100 ON 100Mbps OFF 10 Mbps LK ACT Steady On for LINK LK with no traffic blinking indicates port is transmitting r
2. front and top of LEDs to provide status information when viewed at any angle or mounting arrangement rack mounted MC14 Tray or wall mounted m Rugged metal case Industrial grade CS14 amp CSN14 Series have a robust design and are packaged in a rugged sheet metal enclosure to ensure high reliability and durability even when placed in industrial or outdoor applications my GarrettCom com 22 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 m Qualified to use for temperature un controlled outdoor application The Magnum CS14P Premium rated Hardened version of Converter Switch supports an ambient temperature rating between 40C to 75C for DC models which qualify for un controlled outdoor application m Efficient Compact design for all purpose convenient mounting Featuring a compact steel case with an external AC and internal DC power supply Magnum CS 14 amp CSN14 Series units can be installed with minimal space in rack mount cabinets like MC14 TRAY on table tops or wall mounted m MDIX ports to eliminate cross over cable while cascading All the Magnum CS14 amp CSN14 Series Switches are featured with MDIX auto cross which easily allow cascading with other Switch Hubs or media converters without using the cross over cable Www GarrettCom com 23 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 2 6 Applications for CS14 amp
3. 1 with two 10 100 RJ 45 ports one 10 or 100 Fiber port The Magnum CS14 amp CSN14 Series chassis house one main PC board The power supply unit may be external AC as well as Internal DC The front side of the chassis has two twisted pair 10 100 switched ports and one 10 or 100Mb fiber port Both the RJ 45 ports of the CS14 amp CSN14 Series Converter switch support auto cross MDIX operation performing the auto cross function under auto negotiation mode only The 10Mb fiber Model CSN14 is factory configured at Half duplex and 100Mb fiber Model CS14 at Full Duplex Dual LEDs to indicate operating status of ports are mounted on the top as well as front for extra viewing advantage while rack mounted There is a power PWR indicator for the unit to validate that the unit is turned ON For each port there are Link and Activity Www GarrettCom com ME 16 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 LK ACT LED s on the top of the unit indicating that the media cables are connected correctly and also indicating when there is traffic flashing These LK ACT LED s are repeated on the front as LA1 port 1 LA2 port 2 and LA3 port 3 The single fiber port has been offered as an ST connector Single or Multi mode for Model CSN14 and as an SC Small form factor connector MTRJ multi mode and LC Single mode for 100 Mb Model CS14 The F H manual Switch provided underneath the fib
4. 3 8 6 Power Budget Calculations for CS14 amp CSN14 Series Fiber Media iii ee Re RE RU es 47 3 8 7 Connections to NICs which support Auto Negotiation 49 4 0 OPERATION 0 ccssccsssssscsccsecscescssssesssencssesscecesssssessnsenessssnessesseseoes 50 4 1 Dual Speed Functionality and Switching cc eeeeeeeeeeeeeeeeneeeees 50 Vii CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 4 2 Auto cross MDIX Auto negotiation and Speed sensing 52 4 3 F H Switch Full Duplex or Half Duplex for Fiber port 1 52 4 4 Dual LEDs Front panel and side panel Magnum CS14 amp CSN14 54 5 0 TROUBLESHOOTING cccccsssssrssssesscsesssssssessessssessessesessessesesees 55 5 1 Before Calling for Assistance e eoou20220nus0umanasaesenanensenenonenanen 56 5 2 When Calling for Assistance evaeoon20auonussumanonmranmanesemonaseenenen 58 5 3 Return Material Authorization RMA Procedure cccceeeee 59 5 4 Shipping and Packaging Information 61 APPENDIX A WARRANTY INFORMATION a2mmoma 200022 000222 002220 0020 00000000 62 Revisions Rev C 09 09 Updated DIN Rail mount photo pg 36 Rev B 05 09 added Electrical Safety Requirement pg iv mounting hole location pg 32 changed Wavelength to 1310nm pg 48 updated Latency spec pg 2 corrected ambient temp pg 3 Rev A 04 04 Initial release of this user manual for
5. Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number WwW GarrettCom com UI 59 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 60 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 5 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping
6. Series Converter Switch Installation and User Guide 09 09 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference iii CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 Electrical Safety requirements 1 This product is to be installed Only in Restricted Access Areas Dedicated Equipment Rooms Electrical Closets or the like 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product This product shall be provided with a maximum 10A DC Listed fuse or circuit breaker in the supply circuit when connected to a 48V centralized source The external power supply for DC units shall be Listed Direct Plug In pow
7. be achieved only if the following factors are both applied e The 100Mb fiber segment must operate in full duplex FDX mode and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor 3 8 7 Connections to NICs which support Auto Negotiation The copper ports of Magnum CS14 Sereis Converter Switches will function properly with NICs Network Interface Cards which support Auto Negotiation and the Fast Link Pulse FLP coding for the 100BASE TX signaling system When connecting a NIC to the CS14 Sereis it may be necessary to reload the NIC drivers on the user device if the NIC has been communicating with a protocol other than 1OOBASE TX such as 10BASE T When 100Mb operation is agreed and in use the 10 100 LED is illuminated steady ON and is OFF if 10 Mbps traffic mm Garrettcom com Tn 49 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 4 0 OPERATION 4 1 Dual Speed Functionality and Switching The Magnum CS14 amp CSN14 Series Converter Switches provide four switched ports three ports in the front and one on the rear The architecture supports a dual speed switching environment with auto negotiation capability The switched RJ 45 ports are full duplex and auto sensing for speed See section 2 2 When the connected device is 10 Mbps the CS14s obeys all the rules of 1
8. flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer See Section 4 6 for additional details Another feature implemented in Magnum CS14 amp CSN14 Series Converter Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order Www GarrettCom com 19 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 to stop incoming traffic The latency the time the frame spends in the Switch before it is sent along or forwarded to its destination of the CS14 amp CSN14 Series Converter Switches varies with the port speed types The length of the frame is a variable here as it is with all store and forward switches For 10 Mb to 10 Mb or 10 Mb to 100Mb or 100Mb to 10 Mb forwarding the latency is 15 microseconds plus the packet time at 10 Mb For 100Mb to 100Mb forwarding the latency is 5 microseconds plus the packet time at 100Mb 20 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 2 5 Features and Benefits m Full 100Mb or 10 Mb swit
9. input CSN14HR 24VDC Same as CS14HR 24VDC model but includes DIN RAIL MC2 option CSN14H 48VDC Same as CS14H 24VDC model except for 48 VDC power input CSN14P Pd Pi Premium rated two 10 100 RJ 45 one 10Mb Fiber port Converter Switch for un controlled outdoor env Int 8 to 15V terminal block Ext AC premium Power Supply included CSN14P 12VDC Same as CS 14P Pd Pi except ext AC Premium Power Supply is not included CSN14P 24VDC Same as CS14P 12VDC model except for 24 VDC power input CSN14PR 24VDC Same as CS14P 24VDC model but includes DIN RAIL MC2 option CSN14P 48VDC Same as CS14P 24VDC model except for 48VDC input MC14 TRAY 19 Rack mount tray for 14 series Switch models up to 16 units DIN RAIL MC2 Metal DIN Rail mounting bracket for one CS14 amp CSN14 Series Switch CS14 models have two 10 100 RJ 45 ports one 100Mb Fiber ports with connector choices of SC ST MTRJ SSC SSCL SST SLC amp SFC _ww GarettCom cm ss 10 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 2 0 INTRODUCTION This section describes CS14 amp CSN14 Series models including appearance features and typical applications 2 1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product notify the carrier immediately of any damage which you believe occurred during shipment or delivery Inspect the contents of this package for an
10. single mode long reach 40 0 km 131 240 ft 10BASE FL Fiber optic 2 0 km 6 562 ft 10BASE FL Single mode Fiber optic 10 0 km 32 810ft Www GarrettCom com Ul M 2 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Operating Environment Ambient Temperature CS14 CSN14 32 F to 104 F 0 C to 40 C CS14H CSN14H 13 F to 140 F 25 C to 60 C Long term per independent agency tests UL 40 F to 185 F 40 C to 85 C Short term per IEC Type tests CS14P CSN14P 40 F to 167 F 40 C to 75 C Long term per independent agency tests UL 58 F to 212 F 50 C to 100 C Short term per IEC Type tests 40 F to 185 F 40 C to 85 C Storage Temperature All models Cold Start CS 14H to 20 C CS14P to 40 C Ambient Relative Humidity 5 to 95 non condensing Altitude All models 200 to 50 000ft 60 15 000 m CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Conformal Coating optional for Humidity protection Note H and P models are designed for NEBS compliance including vibration shock and altitude Packaging Enclosure Rugged sheet metal Steel Dimensions Switch unit Height x Width x Depth 3 5 in H x 3 0 in W x 1 0 in D 8 9 cm x 7 6 cm x 2 5 cm Weight all models 8 oz 227g Power supply d and i 5 9 oz 170g Hd and Hi 5 8 oz 165g Pd and Pi 7 9 oz 225g Cooling Method Conv
11. will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device The Link ports are also represented by LA1 LA2 LA3 Steady On or steady Off indicates no Receive Activity 10 100 Steady ON for 100Mb speed OFF for 10Mb speed per port F H Steady ON for Full duplex mode OFF for Half duplex per port 54 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 5 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of Magnum CS14 amp CSN14 Series 10 100 Mb s Switches is a straightforward procedure see INSTALLATION Section 3 0 the operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum CS14 amp CSN14 Series 10 100 Mb s Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support www GarrettCom com 55 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 5 1 Before Callin
12. 0 Mbps Ethernet configurations The 10 Mbps users share a 10 Mbps traffic domain and can communicate with 100Mbps users as well as 100Mbps domain Similarly the 100Mbps traffic obeys the rules of 100Mbps Ethernet and can communicate with 10 Mb domain too Magnum CS14 amp CSN14 Series units are plug and play devices There is no software configuring to be done at installation or for maintenance The only hardware configuration settings is user options for port 2 to configure at FF AN and can be done through a manual switch accessed from the front side The internal functions of both are described below Www GarrettCom com 50 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Switching Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses on the same port segment will be filtered constraining them to one port and relieving the rest of the network from processing them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Packets needed for maintaining the operation of the network such as occasional multi cast packets are forwarded to all ports The Magnum CS14 amp CSN14 Series Converter Switches operate in the store and forward switching mode whic
13. 14 amp CSN14 Series Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pa min where Pr Transmitter Output Power and Pp Receiver Sensitivity Worst case OPB OPB IdB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um m m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km The following data has been collected from component manufacturer s HP s and Siemens web sites and catalogs to provide guidance to network designers and installers 47 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Fiber Speed ia km Wavel Port Mode Module hee CS14 00Mb Multi o 62 5 125 MST MscL FX mode 0 4 50 125 00Mb Single 20 CS14 ssc t FX mode 0 4 1310 9 125 Multi 850 100 140 mode a Single 10 mode 5 1310 9 125 30 39 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Note The use of either multi mode or single mode fiber to operate at 100Mbps speed over long distances i e over approx 400 meters can
14. C14 TR PS9 and MC14 TR PS9X2 are another option available for Rack Mounting the mix match of 10Mbps and 100Mbps Media Converters and the CS14 amp CSN14 Series Switches together in 19 rack mount tray These models comes with built in common universal AC power supply rated at 55 watts at 50 C ambient 12VDC output and supporting up to 10 Switches for MC14 TR PS9 and 16 units CS14 amp CSN14 Series for MC14 TR PS9X2 The MC14 TR PS9X2 Model has two groups of eight units per power supply These models are equipped with auto ranging AC input to the power supplies for use worldwide The MC mounting spaces of the MC14 TR models are specific to the Magnum CS14 amp CSN14 Series 10Mbps FT14 and TB14 and 100Mb 14E series and do not _www GarrettCom com 7 34 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 permit other models to be put in the tray The side view picture shown here is an example of an installation of the model MC14 TR PS9 19 rack mount tray holding a few CS14 amp CSN14 Series 1OMbps FT14 s and 100Mb 14E Media Converters each with their power input plugged into the built in common AC power supply in the rear area of the tray PS units that come with the MC s are not used Metal mounting screws in the bottom front hold each of the media converters secure in the tray separately removable for service The dual LEDs permit viewing operating status of the CS14 Sereis Co
15. CS14 Converter Switch viii CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 1 0 SPECIFICATIONS 1 1 Technical Specifications Ports Performance When a port is operating at 100Mbps Data Rate 100Mbps When a port is operating at 10 Mbps Data Rate 10 Mbps Network Standards 100Mb Ethernet IEEE 802 3u IOOBASE TX 1OOBASE FX 10 Mb Ethernet IEEE 802 3 IOBASE T Auto sensing for speed IEEE 802 3u Packet Processing Between Domains Filter and Forward Rate from 100Mbps ports 148 800 pps max Filtering and Forwarding Rate from 10 Mbps ports 14 880 pps max Processing type Store and Forward non blocking Auto learning 2K address table www GarrettCom com UM 1 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Address buffer age out time 300 sec Packet buffers memory 128KB dynamically shared on all domains Latency not including packet time 100 to 10 Mbps lt Sus 10 to 100Mbps lt 15us 100 to 100Mbps lt 4us 10 to 1OMbps lt 13us Path Delay Value 50 BT on all ports Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft 100BASE FX half duplex multi mode 412 m 1350 ft 100BASE FX full duplex multi mode 2 0 km 6 562 ft 100BASE FX half duplex single mode 412 m 1350 ft 100BASE FX full duplex single mode 20 0 km 65 620 ft 100BASE FX full duplex
16. CSN14 Series Converter Switches Enriched with the three tier YOR hardness ratings flavor Yellow office Orange Hardened Red Premium rated outdoor the multifunctional multi media and multi environmental Magnum CS14 amp CSN14 Series Converter Switches fit very well in almost any environment enabling the user to scale their LAN quickly and cost effectively The edge of the network connectivity solution offered by GarrettCom is focused on providing easier more economical and extra reliable industrial application products The compact designed Magnum CS14 amp CSN14 Series acts as a very useful tool in the modern life of fast expanding network requirements The Dual Speed and Dual media functions support a mixed environment of 10 Mbps and 100Mbps users with copper and fiber media The switching full half duplex capability on fiber ports provides high bandwidth seamless performance The up link of choice of 10 or 100Mb on fiber Port 1 enables easy expansion longer distance coverage and secure networking for the on going demand of Ethernet networks _wwv GarrettCom com jg TT 24 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Example 1 In this example the Magnum CS14 amp CSN14 Series Converter Switches are being deployed together to serve a secured corporate office spread out in miles with multi servers print server internet access and mixed speed requirements but dist
17. Qo GarrettCom Industrial Networking at Its Best Magnum CS14 amp CSN14 Converter Switch Installation and User Guide 5 00 USD CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 Magnum CS14 amp CSN14 Series Converter Switch Installation and User Guide Part 84 00101Z Rev C Trademarks GarrettCom is a registered trademark and Magnum Dymec DynaStar Personal Switch Link Loss Learn S Ring Convenient Switch and Converter Switch are trademarks of GarrettCom Inc Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 Important The Magnum CS14 amp CSN14 Series 10 100 Mb s Converter Switches contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum CS14 CSN14 10 100 Mb s Converter Switches products consult Section 5 Troubleshooting of this User Guide Copyright 2004 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice ii CS14 amp CSN14
18. S14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 8 3 Connecting Fiber Optic SC type Snap In The following procedure applies to installations using SC type fiber connectors i e using multi mode SC and SC single mode While connecting fiber media to SC connectors simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures 3 8 4 Connecting Fiber Optic LC type Small Form factor SFF 7 The following procedure applies to installations using LC type fiber connectors i e using LC single mode While connecting fiber media to LC connectors simply snap on the two square male connectors into the LC female jacks of the Fiber connector until it clicks and secures 3 8 5 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances about 20Km with the multi mode SC The same procedures as for multi mode fiber apply to single mode fiber connectors _wwv GarrettCom com Tn 46 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 8 6 Power Budget Calculations for CS
19. ance and security is the major issue to resolve since each of the video surveillance camera is located more than 100m at the far end to secure the office The users operate at 100Mb as well as at 10 Mb and utility devices such as print servers run at 10 Mbps High performance users need a high bandwidth up link for access to a central LAN and central file servers Any attached node can change speed at any time without affecting network operation or impacting other users The multi functional CS14 amp CSN14 Series Converter Switches provide this solution very efficiently and economically Various features included 10 or 100Mb of fiber flavor option MDIX plug n play Din Rail mountings and dual LEDs rack mounting option through MC Tray make this compact and Converter switch a very effective solution for this requirement 25 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Example 1 CS14 Model no 6K32 _ d Switch a re Model no DS80 Model no DS80 Hub Hub Router a E OIII pitti mmj mmj Server i li b al 4 4 lt Model no CSN14 ae Sn Care m P re 4 4 Model no CS14 Model no CS14 26 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Example 2 In this application of Industrial environments where in a expanding of Industrial network environment the new PLC units are deployed
20. ce collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest To minimize the possibility of dropping frames on congested ports each Magnum CS14 amp CSN14 Series Converter Switch dynamically allocates buffer space from 128Kb memory pool ensuring that heavily used ports receive very large buffer space for packet storage Many other switches have their packet buffer storage space divided evenly across all ports resulting in a small fixed number of packets to be stored per port When the port buffer fills up dropped packets result This dynamic buffer allocation provides the Www GarrettCom com ME 18 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 capability for the maximum resources of the Magnum CS14 amp CSN14 Series unit to be applied to all traffic loads even when the traffic activity is unbalanced across the ports Since the traffic on an operating network is constantly varying in packet density per port and in aggregate density the Magnum CS14 amp CSN14 Series Converter Switches are constantly adapting internally to provide maximum network performance with the least dropped packets When the Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending packets to cause
21. ching services for high performance Ethernet LANs Magnum CS14 amp CSN14 Series Switches provide Fast Ethernet switching on all ports They perform high speed filter forward operations on the traffic giving each port s segment a full 100Mb or 10 Mb of bandwidth m Reduces Network Costs and provide economical solution Magnum CS14 amp CSN14 Series Switches offer the ideal solution to efficiently and inexpensively connect a Twisted Pair and fiber network with 10Mb or 100Mb and help to expand the Ethernet network in a very convenient and economical way m Choice of 10 or 100Mb Fiber option more efficient than media converter Designed as a multi purpose media converter and Switch the 10 or 1OOMb fiber port allows the user to convert the media from copper to fiber and the other RJ 45 ports can be used as diagnostic ports or for more connectivity _ww GarettCom cm 21 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 m Installation is Plug and Play operation is transparent to software The Magnum CS14 amp CSN14 Series Switch operates as a hardware switch only forwarding those packets from each domain that are needed on the other domains Internal address tables are self learning enabling users to change port connections or 10 100 domains without affecting operations E Two sets of LEDs for viewing status from any angle Each CS14 amp CSN14 Series Converter Switch is equipped with two sets
22. d Latency 00 cccecesceesceeceeceeeeeeeeeeeeeeseeeeeesens 17 2 5 Features and Benefits 0 0 0 eee eeesseeecseeeeceseeecesecseesecaecetesecesereaeees 21 2 6 Applications for CS14 amp CSN14 Series Converter Switches 24 3 0 INSTALLATION cccsccccccscccscssceccsscscssccsecsesssccessessnccssssessesssssose 31 3 1 Locating the Converter Switch Unit 0 eee cee ceeeceeceeeeneeeaee 31 3 2 MC14 TRAY for Rack Mounting CS14 amp CSN14 Series Switches 33 3 3 MC14 TR PS9 amp MC14 TR PS9X2 for Rack Mounting 34 vi CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 3 4 DIN Rail mounting Option eee ceeeeecneeeeceeeeecsaeeeceseeneeseeneees 36 3 5 Power Requirements for CS14 amp CSN14 Series SVVitches 37 3 6 Powering the CS14 amp CSN14 with 12V 24V or 48VDC POWET PUT narco torsi a sine E 39 3 7 CS14 Series DC povvered 48V 24V and 12VDC Installation 41 3 8 Connecting Ethernet Media s ssssseseseeseeeeereresrsrrrerrereersrrrerrerereeree 42 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shielded cccccseceessccecseseeeeesseeeceesneeeesseeeees 44 3 8 2 Connecting Fiber Optic ST type twist lock 44 3 8 3 Connecting Fiber Optic SC type Snap In oo eee 46 3 8 4 Connecting Fiber Optic LC type Small Form factor SFF 46 3 8 5 Connecting Single Mode Fiber Optic eceeeeeseeeeeseeseeteeneeeees 46
23. eceiving ACT F H ON full duplex OFF half duplex Mounting option for CS14 amp CSN14 Family of Switches Metal Mounting clips for panel mounting included DIN Rail mounting option Model DIN RAIL MC2 see Section 3 4 Rack mount option MC14 TRAY see http www garrettcom com mc_tray htm Www GarrettCom com 8 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Mean Time Between Failure MTBF 15 years Telcordia Bellcore Method Agency Approvals and Standard Compliance UL Listed UL 60950 cUL CE Emissions meets FCC Part 15 Class A NEBS L3 and ETSI compliant H and P models IEEE P1613 Env Std for Electric Power Substations P models NEMA TS 2 and TEES for traffic control equipment P models designed for UL 2043 above the ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty Three years return to factory Made in USA CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 1 2 Summary of models and descriptions CSN14 d i two 10 100 RJ 45 one 10Mb Fiber port Converter Switch for office and wiring closet env ext AC PS CSN14H Hd Hi Hardened three ports two Rj 45 one 10Mb Fiber Switch Factory floor Int 8 15VDC Ext AC Hardened power supply included CSN14H 12VDC Same as CS14H model except Ext AC Hardened power supply not included CSN14H 24VDC Same as CS14H 12VDC model except for 24VDC power
24. ection on regular model plus the case is used as a heat sink on H and P models www GarrettCom com ME 4 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 POWER SUPPLY AC POWER SUPPLY using an external power adapter All models have a 8 15 VDC output with 6ft long cord and a 2 5mm center ve jack The power supplies are temperature rated to match the Converter Switch ratings Office Ratings 0 to 40 C North America d models Input direct plug in 95 125vac at 60 Hz Output 12vdc 1Amps International i models Input 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord Output 12vdc 1Amps Factory Floor H Ratings 25 to 60 C North America Hd models Hardened factory floor temperature rated Input 6ft AC power cord to IEC 320 connector on the 100 240vac 47 63Hz external power adapter Output 12vdc 1 25Amps Www GarrettCom com 5 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 International Hi models Factory floor temperature rated Input IEC 320 connector on the 100 240vac 47 63Hz external power adapter Requires a user supplied power cord Output 12vdc 1 25Amps Temperature un controlled Premium P Ratings 40 to 75 C North America Pd models Outdoor temperature rated Input 6ft AC power cord to IEC 320 connector on the 95 260vac 47 63Hz external power adapters Output 12vdc 2Amps
25. er and also easily solve the long distance requirement with the fiber port The ruggedness of the CS14Ps steel case and the high reliability of the design compliments the temperature controlled packaging to provide an exceptional Ethernet product In this example the extended temperature rated CS14Ps takes care of the LAN connectivity requirement in a harsh temperature environment mounted above the ceiling in the building In this location the Data Mining through SAN is required for the equipment used in the harsh temp and send over to the server The ongoing demand of growing network can be easily met by this sleek designed converter Switch The steel enclosure and wide selections of DC power input qualifies the Magnum CS14Ps to provide a dependable reliable and economical solution for any temperature un controlled location environments The above mentioned applications are just few of the examples and an attempt to WwW GarrettCom com ME 29 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 make aware of the importance and multi purpose use of this small Switch In the on going demand of Ethernet at the present time the converter switch provides a very economical and efficient solution Model no 6K32 Switch to the users and fills out all of the potential spots of Ethernet requirements while Server holding minimum Moai nomeo space CS14 amp CSN14 Series Converter Switches Installat
26. er port allow the user to fix the fiber port at 10 or 100Mb Half or Full Duplex mode as per the requirement by sliding the manual switch See Section 4 4 The external DC power plug connector or jack is in the right rear of the chassis whereas the internal DC input terminal is provided on the rear side of the unit 2 4 Frame Buffering and Latency The Magnum CS14 amp CSN14 Series Converter Switches are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e are good packets This eliminates the propagation of Www GarrettCom com 17 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded to add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Sin
27. er unit marked Class 2 or listed ITE Power Supply marked LPS which has suitably rated output voltage i e 24VDC or 48VDC and suitable rated output current Product does not contain user replaceable fuses Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process iv CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http Avww GarrettCom com Email support garrettcom com CS14 amp CSN14 Series Converter Switch Installation and User Guide 09 09 TABLE OF CONTENTS Page 1 0 SPECIFICATIONS ccscscccscsscesssccscsccsscsccscsssssssssesssessessessessesseses 1 1 1 Technical Specifications 0 0 eecesesssesecseesecseeeeeeseeeceaecaeesecaeeeeaeeeeees 1 1 2 Summary of models and descriptions eceseceseeseeeeceeeeeeeeeeeeeeees 10 2 0 INTRODUCTION m2 am2ma2na22a2 022220002 200220000200002220 000000 0020000200002020000000 0002 11 2 1 Inspecting the Package and the Product eeeesceesseceeneeceteeeeneees 11 22 Product Description sereia e ea Ee Ea Ae e ins 12 2 3 Magnum CS14 amp CSN14 Series chassis 2 1 with two 10 100 RJ 45 ports one 10 or 100 Fiber port sesseeeseessesseesrsesrsersseees 16 2 4 Frame Buffering an
28. g for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that an AC power cord is properly attached to each Magnum CS14 amp CSN14 Series unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power www GarrettCom com ME 56 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 4 If the problem is isolated to a network device other than the Magnum CS14 amp CSN14 Series 10 100 Mb s switch product it is recommended that the problem device is replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum CS14 amp CSN14 Series Switch and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum CS14 amp CSN14 Series 10 100 Mb s Switch unit or if unknown contact GarrettCom Inc b
29. h eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network 51 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Switching Address Learning The Magnum CS 14 amp CSN14 Series units have address table capacity of 2K node addresses and are suitable for use in large networks They are self learning so that as nodes are added or removed or moved from one segment to another the CS14 amp CSN14 Series automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor of new frequently used addresses To reset the address buffer cycle power down and up 4 2 Auto cross MDIX Auto negotiation and Speed sensing The RJ 45 ports support auto cross MDI or MDIX in the auto negotiation mode according to the IEEE 802 3u standard No crossover cables are needed when connecting the CS14 s to other unmanaged switches legacy hubs managed switches media converters etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software and the result of the auto negotiation is changed in the managed switch by the manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in the CS14 Switches will still work The auto cross function cannot be disabled Www GarrettCom com 52 CS14 amp CSN14 Series Converter S
30. ion and User Guide 09 09 3 0 INSTALLATION This section describes the installation of the Magnum CS14 amp CSN14 Series Converter Switches including location mountings power supply options and media connection 3 1 Locating the Converter Switch Unit All the CS14 amp CSN14 Series Switches operate in transparent half and full duplex mode The store and forward switch easily take care of the network traffic and can be used as a useful economical tool to expand the existing network The compact and lightweight design of the Magnum CS14 amp CSN14 Series allows it to be easily installed in almost any location A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet or for securing the unit on a table top or shelf Alternatively metal mounting clips and screws are included for a rugged and secure mounting in any orientation 31 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Installation of the Magnum CS14 amp CSN14 Series Converter Switches is a simple procedure The installation location is dependent upon the physical layout of the Ethernet network and associated cabling Make sure the unit is installed in a location that is 0 90 easily accessible to an AC power outlet or 0 25 i 0 50 2 00 L MOUNTING povver strip and vvhere BRACKET convection cooling is Co39CCO o o not inhibited The green Povver PVVR Led must
31. ls floating GND Terminal for earth or ground wire connection to the CS14H chassis Input Voltage 8 15V DC 12V DC 18 26V DC 24V DC 30 60V DC 48V DC Input current 0 8 amp 12V DC 0 4 amp max 24V DC 0 2 amp max 48V DC Pover Consumption 3 vvatts typical 4 vvatts maximum mm Garrettcom om 40 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 7 CS14 Series DC powered 48V 24V and 12VDC Installation This section describes the proper connection of the 48VDC leads or 24VDC 12VDC leads to the DC power terminal block on the Magnum CS14H hardened media converter as shown in Figure The DC terminal block on the Magnum CS14H is located on the left side of the unit and is equipped with three 3 screw down lead posts The power terminals are identified as positive and negative and they are floating inside the unit so that either of the terminal may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the CS14H s power terminals positive and negative screws The use of Ground GND optional it connects to the CS14H chassis Ensure that each lead is securely tightened from the top as shown here _wwv GarrettCom com Tn 41 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 NOTE Always use a
32. n two weeks of your purchase WwW GarrettCom com 62
33. nverter Switches from any angle Www GarrettCom com 35 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 4 DIN Rail mounting option The Magnum CS14HR CSN14HR amp CS14PR CSN14PR Converter Switches designed for use in Factory Floor Industrial Ethernet environments are also available for DIN Rail mounting in an enclosure having DIN Rails A Magnum CS14H is shown alongside the DIN Rail MC2 bracket The metal DIN Rail mounting hardware is optional and needs to be ordered as a separate item e g Model HDIN RAIL MC2 It comes with four screws to attach the bracket to the MC unit The Magnum CS 14 Models with HR have 24VDC power and have the DIN Rail MC2 bracket included and assembled with the MC unit at the factory 36 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 5 Power Requirements for CS14 amp CSN14 Series Switches Hd Hi INDUSTRIAL Magnum CS14 amp CSN14 Series Switches are power efficient and can work with an external AC power supply Magnum CS14 amp CSN14 Series require a nominal 12VDC input version The extended temperature Hd version is used for heavy duty and industrial applications The 12V DC power input has a plug of 2 5mm center ve with 6 ft cord All the AC power supply info detail is provided in Technical Specifications Section 1 1 The CS14 amp CSN14 Series are designed to provide reliable opera
34. on all the present network and need a Ethernet port to carry the data to the main workstation for being controlled by the Industrial Engineering crews The hardened version of Magnum CS 14Hs are typically used where 10 100BASE T networking equipment is being installed in highly controlled temp environment and required a effective and economical solution to satisfy this need Built with high grade components and efficient thermal techniques of cooling and equipped with wide variety of options of AC and DC power the CS14 amp CSN14 Series Converter Switches provide the efficient solution for this need The Fiber port option on the converter switches is really suitable for this edge of network requirement where covered distance is also a primary concern to deal with 27 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Example 2 CS14H Model no 6432 Switch ee Model no DS80 Hub Router Model no DS80 Hub II mn E OTIT C hy 4 Model no CS14H on e 28 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Example 3 CS14P or CSN14s The Magnum CS14Ps fits very well in high temperature locations control rooms experiencing a need to scale its LAN quickly and cost effectively With its half full duplex switching capability on fiber port 1 the CS14Ps provides a very economical high bandwidth solution at each cable user access point of copp
35. plications The CS14H models are built with high grade components Fig 2 2 b CS14H with 100Mb SC connector with special thermal techniques and a sealed rugged metal case for heavy duty industrial applications No air inflow is required for cooling so the CS14H resists dust dirt moisture mm Garrettcom com TT 14 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 smoke and insects and is plenum rated Choices of models for external AC or internal DC power are available Ambient operating temperature is 25 C to 60 C Storage temperature rating is between 25 C to 85 C depending on the power source used Fig 2 2c CS14P with 100Mb SC Connector The red label Magnum CS14P as shown in Fig 2 2c with 100Mb SC fiber a premium rated unit suitable for temperature un controlled outdoor applications Specially designed with premium grade extended temperature components the CS14P uses similar thermal techniques to the CS14H hardened units for cooling Mounting options 15 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 include panel mounting DIN rail or rack mount tray Choices of models for external AC or internal DC power are available Ambient operating temperature is between 40 C to 75 C Storage temperature rating is between 40 C to 85 C depending on the power source used 2 3 Magnum CS14 amp CSN14 Series chassis 2
36. protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 Attn Customer Service 61 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom GarrettCom has damaged by misuse misapplication or as a result of service or modification other than the product GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom withi
37. rk for both 10 Mbps and 100Mbps be used whenever possible in order to provide flexibility in a mixed speed network since P80 series switch ports are auto sensing for either 10 and 100Mbps Note that the auto cross function does not operate if the port is fixed or not supporting auto negotiation 43 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shielded The following procedure describes how to connect a 1OBASE T or 1OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with a RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established If this does not help ensure that the cable is connected properly and that the device on the other end is powered and is not defective 4 For Port 1 or 1SW if the LINK LED is not illuminated move the switch which has a cross over or up link for linking to another hub or Switch 3 8 2 Connecting Fiber Optic ST type twist lock The follo
38. t and cost effective for the user The selection of various temperature ranges enable easy deployment in various environments and qualify the Converter Switch as a flexible solution which provides multiple solutions using very small space Providing 12 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 the combination of media converter with Switch the CS14 amp CSN14 Series is an ideal choice for edge of the network applications The Yellow label CS14 amp CSN14 models as shown in Fig 2 2 a with IOMb ST fiber in regular package units are for office and wiring closet environments and use an external AC power supply A metal case with convection cooling is featured Ambient operating temperature is 0 to 40 C Storage temperature rating is 40 to 85 C The units can be mounted securely on a closet wall or metal cabinet by using the metal panel mounting clips included Fig 2 2a CSN14 with 10Mb ST connector The versatility options of the CSN14 model allow the users a wide choice to connect to their 10 or 100Mb domain easily without adding 13 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 any additional media converters The CS14 models provide several options of 100Mb fiber flavor SC MTRJ and LC connectors The orange label Magnum CS 14H hardened units as shown in Fig 2 2b with 100Mb SC fiber are designed for factory floor Industrial ap
39. tion withstand 37 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 higher temperature environments and provide the DC power choices to the user to deploy in uncontrolled temperature environments 12VDC 24VDC 48VDC The Internal 12V DC 8 15V DC has a built in terminal block for ground The 9V DC jack is also present Detail information about the 12 VDC the 24V DC and the 48V DC is provided in the Technical Specifications Section 1 1 The various models of DC power type and extended ambient temperature power supplies are numerous and your choice needs to be called out on your order 38 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 6 Powering the CS14 amp CSN14 with 12V 24V or 48VDC power input Each Magnum CS14H CS14P Series is reliably equipped with an internal DC power supply and has built in screw terminals for secure attachment of the power leads Three models support a range of power input types The three model choices are for use with 12VDC 24VDC or 48VDC power DC power input may be chosen for high availability The extended temperature capability of the DC powered CS14P s can go outdoors rated at 40 C to 75 C If indoors the DC jack is also present and optionally can be used with an external AC power supply 39 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 DC Power Termina
40. turn ON when power is applied through the internal DC input 12V 24V or 48V DC or external AC through 9V DC jack 000 MOUNTING BRACKET p 3 00 I 32 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 3 2 MC14 TRAY for Rack Mounting CS14 amp CSN14 Series Switches For 19 rack mounting of Magnum FT 14 series Media Converters a rack mount tray is available MC14 TRAY The Media Converter units are mounted with their RJ 45 port and DC power jack in the back with either fiber or BNC cable in the front Any mix of the FT 14 type Media Converters may be placed on a tray up to a maximum of 16 units The mounting spaces of the MC14 TRAY are specific to the CS 14 series and do not permit other models A typical installation of the model MC14 TRAY 19 rack mount tray will hold a few often three to eight CS14 amp CSN14 Series Converter Switches with their power supplies plugged into power www GarrettCom com h h TM 33 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 strips not included in the rear area of the tray Metal mounting screws in the bottom front hold the Media Converters firmly in place The beveled top edge of the units permits the LEDs of each unit to be viewed for operational status even when the units are very close together 3 3 MC14 TR PS9 amp MC14 TR PS9X2 for Rack Mounting The M
41. voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate 3 8 Connecting Ethernet Media The Magnum CS14 amp CSN14 Series Converter Switch can be connected to two media types i e fiber and copper RJ 45 types runt at 1OOBASE TX LOBASE T and 100BASE FX or 1OBASE FL CAT 5 cables should be used when making 100BASE TX connections When the ports are used as 1OBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft For fiber port IOBASE FL or 1OOBASE FX multi mode 50 125 or 62 5 125 microns cabling can be used whereas for single mode 9 125 microns cabling should be used Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring _ww GarettCom cm 42 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Media IEEE Standard Connector Twisted Pair CAT 3 or 5 IOBASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode Single mode 10BASE FL ST Fiber Multi mode 100BASE FX ST SC Fiber Single mode 100BASE FX SC LC Fiber Multi mode 100BASE FX MTRJ NOTE It is recommended that high quality CAT 5 cables which wo
42. wing procedure applies to installations using ST type fiber connectors This procedure applies to ports using multi mode ST fiber connectors _wwv GarrettCom com go TT 44 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 1 2 Before connecting the fiber optic cable remove the protective dust caps from the tips of the fiber connectors Save these dust caps for future use Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated orts at each end of the fiber optic segment Connect the Transmit TX port light colored post on the Magnum Fiber port to the Receive RX port of the remote device Begin with the color coded strand of the cable for this first TX to RX connection Connect the Receive RX port dark colored post to the Transmit TX port of the remote device Use the non color coded fiber strand for this The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit after cable connection the normal cause is improper cable polarity Swap the fiber cables at the fiber connector to remedy this situation 45 C
43. witches Installation and User Guide 09 09 When an RJ 45 cable connection is made and each time LINK is enabled auto negotiation takes place except for legacy products which do not have auto negotiation and which go to the default state accordingly The Magnum Switch advertises its capability for 10 or 100 Mbps speed and F H duplex mode and the device at the other end of the cable should similarly advertise respond Both sides will agree to the speed and mode to be used per the IEEE 802 3u standard Depending upon the devices connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed and full or half duplex mode 4 3 F H Switch Full Duplex or Half Duplex for Fiber port 1 The F H manual switch has been provided for fiber port 1 for fixing that port at Full or Half Duplex as per the requirements The F H manual switch is being located underneath the fiber port The Fiber port with 10Mb is being set at Half Duplex and the 100Mb being set at Full Duplex as default from the factory The port can be set at the required mode by sliding the manual switch position to F or H WwW GarrettCom com 53 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 4 4 Dual LEDs Front panel and side panel Magnum CS14 amp CSN14 LED Description PWR llluminates GREEN to indicate power applied LK ACT Steady ON for LINK w no traffic blinking for activity per port LINK
44. y fax phone or email support garrettcom com for assistance 57 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 5 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including Convenient computers workstations terminals and printers plus the various network media types being used www GarrettCom com ME 58 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 5 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form
45. y signs of damage and ensure that the items listed below are included This package should contain 1 Magnum CS14 or CSN14 Series Converter Switch Unit 1 External Power Supply for CS14 or CSN14 d i model only 1 set Metal panel mounting clips and screws 2 each 1 User Guide i e this manual continued next page Www GarrettCom com 11 CS14 amp CSN14 Series Converter Switches Installation and User Guide 09 09 Remove the Magnum CS14 or CSN14 Series Converter Switch from the shipping container Be sure to keep the shipping container should you need to ship the unit at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container Refer to Section 5 Troubleshooting for specific return procedures 2 2 Product Description The multi tasking multi environmental multi media Copper and fiber equipped with multi power AC or DC supply 3 ports two 10 100 RJ45 one 10 or 100Mb fiber CS14 amp CSN14 Series Converter switches offer a flexible cost effective connectivity solution for on going demand of Ethernet Network Available in two different flavors of fiber speed 10Mb ST fiber as CSN14 model and 100Mb SC MTRJ LC fiber as CS14 the CS14 amp CSN14 Series are useful Ethernet devices for the edge of network application The plug and play energy efficient and flavor rich fiber features make this sleek multi purpose Switch convenien
Download Pdf Manuals
Related Search
Related Contents
Hubbell Electric Heater Company 240-3 24 kW User's Manual PLA GUICIDAS ARCHIBUS Space Management - User Guide SPECIFICATION SECTION 16710 - Eastern Washington University Samsung SGH-U800G Korisničko uputstvo 薬食安発 0927 第2 号 平成 25 年 9 月 27 日 SPA SA Wilma lights Copyright © All rights reserved.
Failed to retrieve file