1. With the gas and electricity supplies to the boiler turned on and your programmer and other heating controls set correctly you only need to set the temperature control knob to the desired level 1 Pull the door panel down 2 Confirm Mains On light is on or flashing 3 Turn the temperature control knob to adjust the radiator surface temperature and hot water tap temperature between approximately 63 C and 82 C 4 When there is a call for heat the Burner On light will flash and after several seconds the burner will light automatically The Burner On light will be on whilst water is being heated Q gt Temperature f Mains On peen Control Knob Red Burner On Green Green Resetting If the Lockout light is on or flashing the boiler will need resetting 1 Turn the temperature control knob to e position 2 Wait until the Lockout light goes off 3 Turn the temperature control knob to the required setting The boiler should reset and return to normal operation 4 If the boiler does not reset e Check the fault indicators see label on door panel If the boiler has Overheat or Circulation indicators lit wait 15 minutes for the boiler to cool and reset again e Check that the gas and water supplies to the boiler have not been inadvertently turned off 5 If the boiler still fails to reset or resets then returns to lockout there is a fault that should be attended to by
2. Do not interfere with any sealed components on this boiler intelligently applied technology 5 Got a problem In the unlikely event you have a problem with your boiler please check the following No Heating Hot Water 1 Is the electricity supply to your boiler switched on If so the Mains On Green light will be on or flashing If it is flashing this indicates that the boiler User to check temperature control knob may have turned the fault diagnosis boiler off 2 Is the Lockout Light on or flashing Yes Reset as described on Page 3 No Continue below Contact your installer 3 Is the gas supply turned on 4 Is the programmer or timer switch set to On Refer to the instruction booklet supplied with these items for correct setting and operation 5 Is the temperature control on the boiler turned on and set high enough 6 Are all system controls such as room and cylinder thermostats set high enough 7 Are the thermostatic radiator valves set high enough Installer unable to rectify fault Contact your Installer Installer contacts Help line If you have followed the steps in this simple checklist but your boiler still does not fire contact your installer whose details appear in your Benchmark logbook Any repairs to the boiler will usually be the responsibility of Contact Heateam the Installer during the warranty period Important information you need to arrange an appointment Inst
3. deemed competent In the Republic of Ireland this must be carried out by a competent person as stated in Irish Standard I S 813 Domestic Gas Installations intelligently applied technology 3 Looking after your boiler Servicing and Repair of your Boiler e For reasons of safety and economy your boiler should be serviced annually Only a competent person should service or repair your boiler CORGI How to find a CORGI Registered Installer e Telephone CORGI on 0870 401 2300 e Visit www corgi gas safety com e Look in Yellow Pages or Thomson Directory All Heateam Engineers are CORGI Resgistered Remember Always ask to see your installers CORGI ID card Cleaning the Outer case e The painted panels should be wiped with a damp cloth and then dried completely y Competent Person A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules or valid ACoP equivalents is deemed competent CORGI Council for Registered Gas Installers ACS Accredited Certification Scheme Certificates of competence that are required before installer can become CORGI registered ACopP Approved Code of Practice The previous method of showing compliance for CORGI registration GB Heating Industry definition meaning England Scotland Wales Northern Ireland Isle of Man and the Channel Isles IE Heating Industry definition meaning the Republic of Ireland 4 intellige
4. User Guide and Important Warranty Information Suprima 30 80 HE Condensing Central Heating Boiler Please read this document and keep it safe It will help you out should your boiler need attention Dear User Thank you for choosing a Potterton central heating boiler The following instructions are simple basic steps that you can take to ensure years of trouble free heating and hot water for your home Please complete the warranty registration document supplied with your boiler or register on line at www heateam co uk Heateam offer a full range of customer installer and warranty services Call 44 8706 000653 or visit on line for further detail For future reference please complete the information on the back cover of this guide with your Potterton boiler details installer details and installation date We also recommend that you attach your boiler purchase receipt if available to this guide Benchmark Log Book Please ensure that your installer hands your Benchmark logbook over to you with the Installation and Commissioning sections completed The details in the Log Book will be required in the event of any warranty work Keep the Log Book in a safe place and ensure that the relevant sections are completed at each service visit Baxi Heating UK Ltd is a BS EN ISO 9001 Accredited Company Benchmark Potterton is a member of the Benchmark initiative and fully supports the aims o
5. a competent person To Turn Off If you need to turn the boiler off turn either the temperature control knob to position or set the programmer timer to Off if fitted Do not switch off the main electrical supply to the boiler whilst the Burner On light is on Boiler Protection The protection systems shown below will always be working whilst the gas and electricity supplies to the boiler are on To ensure the boiler is protected during very cold conditions a frost protection feature is built in to the boiler If the boiler temperature falls below 4 C the boiler will fire until a temperature of 15 C is reached The boiler incorporates a built in pump protection feature which continually monitors the time since the pump last operated The pump will run for around 2 minutes if it has not run in the last 24 hours This may occur during the night when your heating controls are set to off The boiler is fitted with a safety thermostat to protect against overheating of the water If this thermostat operates the boiler will lockout and the Lockout Red light will flash once a second The boiler will require resetting before it will re light A frost thermostat may have been fitted to your system Your installer will have advised you of this gt Competent Person A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules or valid ACoP equivalents is
6. aller Help line Should your installer need assistance he she can contact our trade support help line for diagnostic and remedy advice Product serial number Make and model Installer details Proof of purchase Contact heateam 08706 096096 N N NQNAN intelligently applied technology Got a problem Heateam If there is a fault with your boiler under warranty that your installer is unable to rectify please contact heateam where one of our customer service advisors will be happy to make the necessary arrangements Please have the following details to hand when contacting Heateam e Your boiler serial number e Your boiler make and model number e Your installer details e Proof of purchase date If you are unable to quote a valid serial number at the time of booking you will need to provide payment of our standard repair charge via credit debit card in order to make an appointment for one of our engineers to attend Our engineer will validate your serial number or proof of purchase on site and will determine whether any refund will be made In the event that the engineer identifies that your boiler is not covered by our warranty we will retain the repair charge A fault with your boiler will be rectified free of charge providing your warranty is validated and that the defect is a result of faulty workmanship or material This would not apply to a boiler subject to misuse or to system or ancillary contro
7. f the programme It has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of central heating systems to ensure safety and efficiency Heateam The customer service division of Baxi Potterton that operates 363 days of the year 2 intelligently applied technology Introduction Points to note Your new boiler works automatically without a pilot light The energy efficiency of your new boiler means that water vapour condenses inside the boiler itself This water is taken away from the boiler to a suitable drain At times of low temperature a white plume can be seen at the boiler flue terminal on the outside of your house This is water vapour due to your boiler condensing and is normal Warranty Potterton provide a 12 month warranty on this boiler The warranty operates from the date installation is completed for the customer who is the original user To maximise the benefit from our warranty we urge you to return the reply paid warranty registration Details of your installer should have been recorded in the Benchmark Logbook A fault with the boiler will be rectified free of charge providing your warranty is validated and that the defect is a result of faulty workmanship or material This would not apply to a boiler subject to misuse or to system or ancillary controls During the period of the boiler warranty Potterton will
8. ls See Warranty on Page 2 for more information How to contact us The heateam call centre is available 363 days per year 7 days a week 8 00am to 6 00pm on weekdays and 8 30am to 2 00pm at weekends and Bank Holidays Tel 08706 096096 Fax 01926 410006 E mail service heateam co uk Excluding Christmas day and New Year day To aid in continuous improvement and staff training calls to this line may be monitored or recorded Warning If you smell gas Turn off the gas supply at the meter and call your gas supplier immediately In GB Transco operate a 24 hour emergency service and the telephone number will be listed in your telephone directory Faulty boiler If it is Known or suspected that a fault exists on the boiler it must not be used until the fault has been corrected by a competent person GB Heating Industry definition meaning England Scotland Wales Northern Ireland Isle of Man and the Channel Isles Competent Person A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules or valid ACoP equivalents is deemed competent In the Republic of Ireland this must be carried out by a competent person as stated in Irish Standard I S 813 Domestic Gas Installations intelligently applied technology 7 BAXI POTTERTON A Trading Division of Baxi Heating UK Ltd Brownedge Road Bamber Bridge Preston Lancashire PR5 6UP Website
9. ntly applied technology For your safety e This appliance must be installed in accordance with the manufacturer s instructions and the regulations in force Read the instructions fully before installing or using the boiler e Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty In GB this could also infringe the Gas Safety Installation and Use Regulations e Your boiler must not be operated without the casing correctly fitted and forming an adequate seal e e Take note of any warning labels on your boiler e Your boiler should have the following minimum clearances for Safety and Maintenance front 15mm 610mm for servicing access side 5mm each side below 130mm above 125mm e If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings e Flammable materials must not be stored in close proximity to your boiler e Avoid skin contact when your boiler is in operation as some surfaces may get hot i e sight glass pipework e Ensure that the flue terminal outside the house does not become damaged or obstructed particularly by foliage e Ensure that the condensate drain is not blocked modified or damaged as any of these conditions could affect the operation of your boiler
10. only be responsible for the cost of work done by them or on their instructions by their Agent We cannot accept any liability for expenditure or work done by other parties without our knowledge and or approval Visits outside the terms of the boiler warranty will be charged for both parts and labour at our normal rates for chargeable work Details are available on request This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact RECOMMENDED This product has an energy rating B on a scale of A to G For more information see www boilers org uk This is a certification mark Operating your boiler and system The Central Heating and Hot Water you need will be available when the gas and electricity supplies to the boiler are turned on with the timer and other heating controls in your system set correctly Other heating controls are items such as room thermostats cylinder thermostats and thermostatic radiator valves To give the most energy efficient performance these controls can switch your boiler on and off even when your timer is on Instructions on how to use your programmer and other heating controls should have been supplied with the items Potterton also produce a guide How to get the best out of your NEW Central Heating System Telephone our Literature Hotline on 08706 060 623 to request your free copy
11. www potterton co uk A BAXI GR UP company Publication No 5111597 Iss 01 07 2004 Potterton Suprima HE Suprima 30 HE Suprima 40 HE Suprima 50 HE Suprima 60 HE Suprima 70 HE Suprima 80 HE G C No 41 075 35 G C No 41 075 36 G C No 41 075 37 G C No 41 075 38 G C No 41 075 39 G C No 41 075 40 Please complete the boxes below Model and size slul oll IDOE AUOOOo0 Appliance type Hell tego He eHe Date of Installatio AOOOUo Installer Details name address and contact number s The serial number is situated on the Users Operating Instructions label on the rear of the door panel Example of serial number label Ee O SER No LWLO201 za Lower door panel Serial No Label

Download Pdf Manuals

image

Related Search

Related Contents

Face à la démolition du service public d`Education Renforcez la FSU  Manual de Instruções K 3.350  HammerHead Electronics Manual  印刷用(PDF) - アライドテレシス  Simpli Home 3AXCBURTVS Instructions / Assembly  Télécharger - Communauté d`Agglomération Royan Atlantique  IAN 102538    Betriebs - Pumpenscout  Garmin Mobile™ 10  