Home
GEMINI EXPRESS MULTIPLEXER User's Guide
Contents
1. EXPRESS MULTIPLEXER User s Guide TABLE OF CONTENTS SAFETY Federal Communications Commission FCC Statement Classification of LED Transmitter Device INTRODUCTION UNPACKING ACTIVE PAIR SETUP DESCRIPTION CONFIGURATION MODE DESCRIPTION COLLAPSED RINGS CONNECTIONS INSTALLATION Host side multiplexer installation Device side multiplexer installation PROBLEM SOLVING The MULTIPLEXER s front panel power LED is off The MULTIPLEXER s RX LED 1s off or flashing The MULTIPLEXER s TX LED 1s off A device 15 down or unstable Devices interfere with each other Devices cannot operate in Express mode Flashing Express LEDs Express LEDs on without data activity SPECIFICATIONS WARRANTY STATEMENT RETURN MERCHANDISE PROCEDURE COND Nn W 11 12 16 16 17 19 19 19 19 19 20 20 20 20 21 23 23 SAFETY Note READ THIS FIRST 1 Do not look into any fiber optic connection or fiber optic cable 2 Do not connect GEMINI EXPRESS MULTIPLEXER to any type of public network 3 Do not connect any outdoor cabling to the GEMINI EXPRESS MULTIPLEXER without proper lightning protection Do not use unauthorized power supplies or cables Do not connect to non 5250 protocol devices Do not disassemble or modify the power supply and its cables Disconnect all cables prior to configuration Devices attached to the UTP network must comply with the voltage and current limits for Class 2 Power Limited Sign
2. The external power supply is mounted on the rear panel of the GEMINI EXPRESS MULTIPLEXER The AC power cord must be firmly inserted into the external power supply and strained relieved Insert the male end of the AC power cord into a properly wired receptacle All data amp mode LED s on the GEMINI EXPRESS MULTIPLEXER will activate for two seconds and fade off The amber power LED on the front panel the green power LED on the top of the external power supply and the TX amp RX LEDs will activate and remain on If any terminals are on the data activity LEDs will activate If express devices and an express host are attached the port status LEDs upper green LEDs will activate Devices a ring application will not show a sign on screen until the ring is complete 18 PROBLEM SOLVING If problems are encountered with the GEMINI EXPRESS MULTIPLEXER the following guideline 15 intended to provide a quick resolution 1 Collect all information relevant to this application e GEMINI EXPRESS MULTIPLEXER serial numbers Host type and operating system software level e Quantity and type of peripheral devices e Interconnecting cable types and distances e Equipment environment e Interconnection diagrams 2 Setup the application with all Multiplexers in one room interconnected with fiber optic jumpers Verify the application with a host port and a terminal 3 Search through the common problems and possible causes p
3. 3 Category 3 Category 3 2X Category 3 2X Category 3 2X Category 5 Category 5 Category 5 Category 5 2X Category 5 2X Category 5 2X e Note Distances must be derated as follows e 62 ft per category interconnect for e 38 ft per category interconnect for 2X e 16 ft per category interconnect for e 11 ft per category interconnect for 2X 5 e Cable distances over 1000 must be derated by 25 for ring applications Distance fiber optic backbone 62 5 micron multimode fiber Point to Point Ring 3 Units Ring 4 Units 5250 1 amp 2Mbps transparent 8 Shielded RJ45 or DB25 Location Host to GXM to Device GXM to GEMINI HUB Host to GXM to Device GXM to GEMINI HUB Host to GXM to Device GXM to GEMINI HUB Host to GXM to Device GXM to GEMINI HUB up to 2 Kilometers Distance up to 2000 ft up to 1800 ft up to 1000 ft up to 1000 ft up to 900 ft up to 500 ft up to 2000 ft up to 2200 ft up to 1200 ft up to 1500 ft up to 1650 ft up to 900 ft up to 1 5 Kilometers between units and up to 4 5 Kilometers overall up to 1 Kilometers between units and up to 4 Kilometers overall 21 Active data pins Optical Specifications Fiber optic budget point to point Fiber optic budget ring 3 unit ring 4 unit ring Peak power wavelength Fiber optic connectors Power requirements Power supply type Dimensions Warran
4. Ports 0 3 comprise one polling group and ports 4 7 make up the other polling group The TWINAX Brick Detail illustrates a proper connection 13 62 5 micron multimode fiber p GXM8 Remote REE GXM8 Controller peon PANEL UTP cabling Balun amp T L Two 4 Port Twinax arsa a WALL Bricks amp ASF Baluns 3 PLATE Typical Remote Controller Installation 14 62 5 micron multimode fiber Balun amp T cable Up to 8 Twinax Ports amp ASF Baluns w WALL Citi PLATE Typical System 3X Installation 15 INSTALLATION Host side Multiplexer installation l Set the configuration switches on the rear panel of the host side GEMINI EXPRESS MULTIPLEXER as follows SWITCH 1 ON SWITCH 2 ON for a point to point application Or SWITCH 1 ON SWITCH 2 OFF for a ring application WARNING GEMINI EXPRESS MULTIPLEXER is designed for 19 rack The unit should be properly installed using all four mounting holes Rack hardware is not provided It 1s recommended that plastic or nylon washers be used under mounting screws to protect the chassis s finish A polling group is a group of ports which have one port active at a time The new AS 400 work station controllers WSC have two polling groups Ports 0 3 and ports 4 7 constitute the two groups The GEMINI EXPRESS MULTIPLEXER can accommodate two polling in the same fashion The GEMINI
5. gt y YY DEVICE CONNECTIONS 10 COLLAPSED RINGS The Ring mode is seldom implemented as depicted in the previous section Typically fiber optic cables star out from a central location Therefore a ring 1s created by interconnecting the fiber optic star segments at the central location This technique is known as a collapsed ring FIBER OPTIC PATCH PANEL REMOTE MULTIPLEXER 2 REMOTE MULTIPLEXER 3 COLLAPSED RING 11 CONNECTIONS 62 5 micron multimode AS 400 8 Port Twinax Brick ASF Baluns See below for detail Typical AS 400 Installation TO AS 400 wsc GXM_ POLLING GROUP 1 POLLING GROUP 2 7 TO GXM 0 4 02 4 11 gt PORT 4 PORT 1 lt sau e 9 EG L lt PORT 2 4 saai RT _ ee lt gt PORT 3 4 51 gt 37 4 0 PORTH PORT amp POLLING GROUP ASSIGNMENTS ON THE TWINAX BRICK FOR THE NEW AS 400 WSC WITH SPLIT POLLING FEATURE FRONT VIEW AS 400 Twinax Brick Details 12 62 5 micron multimode DB25 to DB25 Balun amp T cable STP CABLE Typical AS 400 Direct Connect Installation A major difference between the newer AS 400 work station controllers WSC and the older WSCs is the number of polling groups The older WSCs had one polling group for all eight ports The newer WSCs have two polling groups Divide the TWINAX brick in two
6. top cover screws located on the rear panel e Gently slide the top cover back one inch e Hold the top cover and tilt it up Reconfigure the jumpers located behind the RJ45 connectors as required Settings for polarity and active pair assignment are shown below ACTIVE PAIR JUMPER SETTINGS It should be noted that connections to the DB25 and the RJ45s are mutually exclusive If any of the three pairs of the RJ45 are selected the DB25 is disconnected If the DB25 is selected the RJ45s are disconnected jumper settings must be identical To reinstall the top cover tilt the top cover down and slide the top cover forward until it mates completely with the bottom cover Install the 2 top cover screws o o eee o RJ45 RJ45 RJ45 RJ45 415 45 3 6 RJ45 1 2 DB25 DESCRIPTION The GEMINI EXPRESS MULTIPLEXER s indicators and connections are described below li Polling Polling Power Group 1 Group 2 Fiber Status LEDs Power LED Ambe LED activates when the GEMINI EXPRESS MULTIPLEXER is powered up TX Activity LED Green LED activates when a signal is transmitted to the fiber optic aggregate link RX Activity LED Green LED activates when a signal is received from the fiber optic aggregate link and the MULTIPLEXER synchronizes to it Polling Group Status LEDs The upper green LEDs are express mode indicators These LEDs activate when an express signal is detect
7. EXPRESS MULTIPLEXER polling group 1 consists of ports 0 3 and GEMINI EXPRESS MULTIPLEXER polling group 2 consists of ports 4 7 Do not connect more than one host polling group to a GEMINI EXPRESS MULTIPLEXER polling group Connect the host ports to the GEMINI EXPRESS MULTIPLEXER ports DO NOT LOOK INTO ANY FIBER OPTIC CONNECTOR OR FIBER OPTIC CABLE 4 The GEMINI EXPRESS MULTIPLEXER has ST style fiber optic connectors Connect the multimode fiber optic cables to the optical link connectors located on the rear panel of the MULTIPLEXER Note the fiber color or number on TX amp RX to ensure proper connection at the remote multiplexer location Strain relieve and label all cables The external power supply is mounted on the rear panel of the GEMINI EXPRESS MULTIPLEXER The AC power cord must be firmly inserted into the external power supply and strained relieved 16 Insert the male end of the AC power cord into a properly wired receptacle All data amp mode LED s on the GEMINI EXPRESS MULTIPLEXER will activate for two seconds and fade off amber power LED on the front panel the green power led on the top of the external power supply and the TX LED will activate and remain on At this time the data activity LEDs will flash at the host s polling rate The RX LED will be off until the remote Multiplexer is installed Device side Multiplexer installation 1 Set the configuration switches on the rea
8. able is data grade e Verify that the wiring uses natural pairs e Verify that the wiring avoids sources of environmental noise e Verify that the balun s pinout matches the GEMINI EXPRESS MULTIPLEXER s pinout e Verify that the host side balun s pinout polarity match the device side balun s pinout polarity Devices interfere with each other e Verify that there is one host polling group per GEMINI EXPRESS MULTIPLEXER polling group e Verify that devices on star segments have unique addresses e Verify that all devices are properly terminated Devices cannot operate in Express mode e Verify that the host and the device are capable of Express mode e Verify that all interconnecting components support the Express mode e Verify that all devices on the port are Express ready e Verify that all cable distances are within the Express specification e controller may have down shifted to 1MBPS due to errors during installation The controller will retry the Express mode in approximately one hour Flashing Express LEDs e Determine the number of Express devices on the port If there are less than seven devices the flashing Express LED 1s normal Express LED on without data activity e Ifthe host is disconnected during an express connection the express LED remains on 20 SPECIFICATIONS Protocol Data rate Number of ports Port connector types Cable Distances Cable Type Data Rate Category 3 Category
9. accept any interference received including interference that may cause undesired operation Classification of LED Transmitter Device Important The optical transmitter contains an LED system and 1s classified CLASS 1 LED PRODUCT per EN60825 1 A11 Safety of Laser Products Contact NLynx Technologies for repair if your GEMINI EXPRESS MULTIPLEXER ever requires maintenance INTRODUCTION This user s manual presents the GEMINI EXPRESS MULTIPLEXER for use with the IBM 5250 protocol The 5250 family of products consists of the IBM s System 34 36 38 and the AS 400 along with many supporting devices manufactured by IBM and other companies The GEMINI EXPRESS MULTIPLEXER works with all supporting devices that are designed within the 5250 specifications GEMINI EXPRESS MULTIPLEXER Decision Data s MULTIPLEXER Gemini Eight Port Express Fiber Optic Multiplexer offers the unique ability to allow multiple AS 400 controller polling groups to be transmitted over a single fiber optic pair This feature allows all new AS 400e controllers to provide their maximum throughput potential in either 1Mbps Optimized or 2Mbps Express mode by transparently multiplexing the split polling feature without requiring performance robbing PTF s new IBM controllers support the split polling feature as a means of achieving higher throughput rates even when connected to standard legacy devices The Gemini Express Multiplexer allows the split polling fea
10. al Circuits as defined by article 725 of the National Electrical Code and Section 16 of the Canadian Electrical Code 9 For your safety receptacles must be properly wired and grounded 10 Never attempt to service equipment connected to the data cable network or the grounded receptacle during an electrical storm Exposure to lethal voltages may occur when lightning is present The following FCC statement applies to the NLynx GEMINI EXPRESS MULTIPLEXER Federal Communications Commission FCC Statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must
11. ed and remain until a IMBPS signal is detected or a system reset occurs The lower green LEDs are data activity indicators These LEDs activate when a signal is present Polling Group Connectors There are two polling groups Each polling group has been divided into two port groups Polling group 1 consists of ports 0 3 port groups A amp B and Polling group 2 consists of ports 4 7 port groups C amp D Ports within polling group must be connected to ports from controller x Z FIBER PRODUCT DB25 OPTIC IDENTIFICATION LINK LABEL FCC LABEL EXTERNAL POWER SUPPLY CONFIGURATION DC POWER SWITCHES CONNECTION REAR VIEW CONFIGURATION The configuration switch settings are shown below DEVICE SIDE MULTIPLEXER CONFIGURATION SWITCHES DEVICE SIDE MULTIPLEXER RING MODE LEGEND CONFIGURATION SWITCHES MODE DESCRIPTION A POINT TO POINT link is comprised of two Multiplexer s connected by a single backbone A diagram of a POINT TO POINT link is provided below HOST PORT CONNECTIONS DEVICE CONNECTIONS MULTIPLEXER MULTIPLEXER Multiple Multiplexers which are connected in series with fiber optic transmit to fiber optic receive constitute a RING topology A diagram of a RING application is provided below DEVICE CONNECTIONS HOST PORT FIBER OPTIC BACKBONE DEVICE CONNECTIONS CONNECTIONS MULTIPLEXER MULTIPLEXER A holD a
12. r panel of the device side GEMINI EXPRESS MULTIPLEXER as follows SWITCH 1 OFFSWITCH 2 ON for a point to point application Or SWITCH 1 OFFSWITCH 2 OFF for a ring application 2 WARNING The MULTIPLEXER is designed for 19 rack The unit should be properly installed using all four mounting holes Rack hardware is not provided It is recommended that plastic or nylon washers be used under mounting screws to protect the star s finish DO NOT LOOK INTO ANY FIBER OPTIC CONNECTOR OR FIBER OPTIC CABLE 3 The GEMINI EXPRESS MULTIPLEXER has ST style fiber optic connectors For point to point applications connect the multimode fiber optic cable attached to the host side Multiplexer s to the device side multiplexer s RX optical link connector located on the rear panel of the GEMINI EXPRESS MULTIPLEXER and connect the multimode fiber optic cable attached to the host side Multiplexer s RX to the device side Multiplexer s TX optical link connector located on the rear panel of the GEMINI EXPRESS MULTIPLEXER For ring applications connect the fiber optic TX of a Multiplexer to the fiber optic RX of the next multiplexer down stream in the ring until the ring is complete Ensure that the cables are properly strained relieved and labeled Connect the GEMINI EXPRESS MULTIPLEXER ports to the host ports of the GEMINI active or passive star and follow the installation procedure for the star
13. rovided below The GEMINI EXPRESS MULTIPLEXER front panel power LED is off e Verify that the AC amp DC connections are proper e Verify that the AC outlet is functioning correctly If the problem persists observe the status of the external power supply s LED and contact Decision Data s technical support The GEMINI EXPRESS MULTIPLEXER RX LED is off or flashing e Verify that the fiber optic connectors are properly connected e Verify that the fiber optic budget and distance has not been exceeded The GEMINI EXPRESS MULTIPLEXER TX LED is off e Contact DECISION DATA technical support If problems persists Contact DECISION DATA technical support A device is down or unstable e Verify that there is one host polling group per GEMINI EXPRESS MULTIPLEXER polling group e Verify that the host s device type matches the device e Verify that the host work station controller s WSC capacity has not been exceeded e Verify that the device is properly terminated A peripheral is terminated when its twiaxial port has two 54 9 ohm resistors located 19 between the A phase pin amp earth ground and the B phase pin amp earth ground Termination is provided by a Y T cable assembly or by a terminating balun 1 ASFT sertes e Verify that there are no polarity reversals in the cable e Verify that the cable distance does not exceed the GEMINI EXPRESS MULTIPLEXER specification e Verify that the c
14. ture to remain enabled with performance of up to 4 times greater than standard legacy 1Mbps 5250 protocol The Gemini Express Multiplexer has 8 Shielded RJ45 port connections as well as a DB25 direct connection eliminating the need for the twinax brick and associated twinaxial cabling Link connectivity is via ST fiber optic multi mode connection with ability to operate in both point to point and multi point ring topologies reducing hardware requirements by up to 50 Other features include Advanced Noise Filtering LED Port Diagnostics Configurable UTP Pin Assignments and a Field Replaceable wide ranging Power Supply UNPACKING Remove the packing material and check for the items below GEMINI EXPRESS MULTIPLEXER A 100 240 VAC input external power supply is attached on the rear panel USER S MANUAL AC POWER CORD Gemini Multiplexer Users Guide North American units only Visually inspect all items for damage If any component is damaged contact NLynx Technologies for a replacement DO NOT APPLY POWER TO ANY DAMAGED COMPONENT ACTIVE PAIR SETUP All GEMINI EXPRESS MULTIPLEXERS can be factory configured per customer request The factory default setting is Pins 4 amp 5 Different configurations will be indicated on the label on the bottom of the unit IDENTIFICATION LABEL The active pair may be re configured by performing the following procedure e Disconnect all power to the unit e Remove the two
15. ty Configurable per customer requirement 12 dB typical 10 dB typical 8 dB typical 820 nanometers two ST style 90 to 250 VAC at 50 to 60 Hz External 1 75 x 19 1U Three years 22 WARRANTY STATEMENT This NLynx product Is warranted to be free from defects material and workmanship for a period of three years from the date of purchase NLynx s liability under this warranty is limited to cure repair or replacement of the product NLynx shall not be liable for injury property damage or other direct or indirect consequential damage including but not limited to loss of profits or other damage or expenses arising directly or indirectly from the installation removal maintenance use or non use of the product used separately or in combination with other equipment These warranties shall become void where it is determined at the sole discretion of NLynx that the product has been exposed to excessive physical or operational abuse acts of God or theft Repairs performed by someone other than by NLynx will void this warranty This warranty is in lieu of any and all other watranties expressed or implied by NLynx representatives or distribution including fitness for particular purpose and merchantability The customer may at their option purchase an Assist Service Agreement that would provide same day overnight shipping response for field replacement of faulty equipment to maintain your data communication system
16. while equipment repairs are completed Contact our Sales department for further details RETURN MERCHANDISE PROCEDURE In the event that the product is not as warranted the customer must contact NLynx for a return merchandise authorization number RMA before returning the product to NLynx Out of warranty repairs are available on a time and materials basis The customer must contact NLynx for a return merchant number RMA prior to shipping the malfunctioning unit to NLynx The customer is responsible for all shipping and insurance charges to and from NLynx NLynx Limited 4 Floor The Graftons Stamford New Road Altrincham Cheshire WA14 1DQ U K Tel 44 0 161 928 7014 Fax 44 0 161 928 7015 www nlynx co uk 23
Download Pdf Manuals
Related Search
Related Contents
Service Manual How To Use – English Care & Cleaning Canon imageCLASS 1100 Laser Printer Use and Care Manual Mode d`emploi - Rey Allround AG V7 Replacement Battery for selected Dell Notebooks Emerson FIELDVUEDVC6200p Instruction Manual Interactive maps of the world's population User's guide and Copyright © All rights reserved.
Failed to retrieve file