1. Open the isolating valves and check for leaks 475 The overall height of the grille is 100mm Use care when cutting the opening CLEAN 5 DE BURR PIPE ENDS 4 Installation Guide Vent air through the bleed screw Isolate electrical supply and connect the heater electric cable to the fused spur 3A Ensure the fused spur is not directly above the heater and is accessible after installation is complete The wires in the mains cable are coloured in accordance with the following code Earth Green And Yellow Neutral Blue Live Brown If the colours of the wires in the electrical cable of this heater do not correspond with the coloured markings identifying the terminals in your fused spur proceed as follows NL Rh RL The wire which is coloured GREEN AND YELLOW must be connected to the terminal in the fused spur which is marked with the letter E by the Earth symbol coloured GREEN or coloured GREEN AND YELLOW The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED Commissioning Turn on the electrical supply at the fused spur Turn on the central heating system Set any room thermostat s to maximum Set the heat output switch to Within a few moments the fan will run and the heat w
2. the top of the product and any shelving is essential To avoid the possibility of vibration this product must be installed on a flat even surface There must be no rear access to the product after completion of the installation A remote room thermostat can be used in conjunction with this heater Interrupt the supply between the fused spur and the heater Refer to the instructions supplied with the thermostat If in doubt call the helpline on 01245 324560 The flexible installation hoses supplied are suitable for use with either 15mm diameter copper pipe or cross linked polythene barrier pipe to BS 7291 For all other types of pipe we recommend the use of compression type fittings Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide We recommend the use of a kneepad when installing this product Cut the opening in the plinth to the size shown Use method A or B If using method B you will require support underneath the heater Clean and de burr both the heater and system flow and return pipes Failure to do so may damage the seal in the flexible hose connection and lead to water leaks Mark the pipes 24mm from the end Fit isolating valves not supplied to the system flow return pipes Failure to fit isolating valves may mean that the product is not serviceable in the event of failure Connect the flexible hoses between the system pipework and heater
3. Kitchen Heater Installation and User Guide INSTALLATION GUIDE USER GUIDE Kitchen Heater Central Heating Kitchen Heater Central Heating Kitchen Heater Electric Kitchen Heater Electric Installation Guide Product complete with fixed grille and pre wired mains cable Fixing screws 2 gt One pair flexible installation hoses Overlay grille In the event of any items missing or visible damage please contact us on 01245 324560 This heater is primarily intended for installation in the space beneath kitchen cupboards behind the plinth However it can also be installed in similar applications such as stair risers and other built in furniture This heater must not be installed in a bathroom or other high humidity areas This heater is designed for use on standard two pipe pumped central heating systems Pipes are 15mm and either may be used as flow or return This product is not suitable for one pipe systems This heater is classified as a fixed appliance and electrical connection should be via a double pole 3A fused spur with a minimum contact gap of 3mm The fused spur must not be directly above the heater but should be accessible after completion of the installation If the pre wired mains cable is damaged it must be replaced by either the manufacturer its service agent or similarly qualified persons The appliance must be earthed To ensure adequate airflow a minimum clearance of 20mm between
4. RED Commissioning 1 Turn on the electrical supply at the fused spur 2 Set any room thermostat s to maximum 3 Set the upper switch to ON the fan will run 4 Set the middle 1kW switch to ON heat will flow immediately 1kW 3 Set the lower 2kW switch to ON additional heat will flow 2kW When the installation is working correctly remember to reset any room thermostat s to its normal setting 3 Position the heater making sure the electrical cable is not snagged 4 Fix heater to plinth AL ON DI GRILLE TO PLINTH SECURING SCREWS 1 Fan does not run no heat output 2 If the overheat protection has activated manually reset as follows 4a If required fit the overlay grille Remove the screws holding the fixed grille to the plinth place the overlay grille over the fixed grille and refit the screws OWERLAY GRILLE a Check the power supply is switched ON b Check fuse in the fused spur c Check the fan switch is ON a Switch the power supply OFF at the fused spur b Wait five minutes for the overheat cut out switch to reset c Switch the power supply ON In the event of any difficulty please contact us on 01245 324560 It will be more helpful if you do not remove the product from the central heating system User Guide gt Your kitchen heater is designed to operate as part of your central heating system in the same way as a panel radiator Pro
5. able Fixing screws 2 kg Overlay grille In the event of items missing or visible damage please contact us on 01245 324560 This heater is primarily intended for installation in the space beneath kitchen cupboards behind the plinth However it can also be installed in similar applications such as stair risers and other built in furniture This heater model must not be installed in a bathroom or other high humidity areas This heater is classified as a fixed appliance and electrical connection should be via a 10A double pole fused spur with a minimum contact gap of 3mm The fused spur must not be directly above the heater but should be accessible after completion of the installation If the pre wired mains cable is damaged it must be replaced by either the manufacturer its service agent or similarly qualified persons To ensure adequate airflow a minimum clearance of 20mm between the top of the product and any shelving is essential To avoid the possibility of vibration this product must be installed on a flat even surface There must be no rear access to the product after completion of the installation A remote room thermostat can be used in conjunction with this heater This heater is fitted with overheat protection The heater will automatically stop in the event of the heating elements reaching the cut out temperature In the event of any difficulty please contact us on 01245 324560 Please note the guar
6. antee may be invalidated if this product is not installed and used in accordance with this guide We recommend the use of a kneepad when installing this product Cut the opening in the plinth to the size shown Use method A or B If using method B you will require support underneath the heater Isolate the electrical supply and connect the heater electric cable to the 10A fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation PUNTH i 1 mh a O en 4 475 The overall height of the grille is 100mm Use care when cutting the opening Installation Guide The wires in the mains cable are coloured in accordance with the following code Earth Green And Yellow Neutral Blue Live Brown If the colours of the wires in the electrical cable of this heater do not correspond with the coloured markings identifying the terminals in your fused spur proceed as follows The wire which is coloured GREEN AND YELLOW must be connected to the terminal in the fused spur which is marked with the letter E by the Earth symbol coloured GREEN or coloured GREEN AND YELLOW N or coloured BLACK The wire which is coloured BLUE must be connected to the terminal which is marked with the letter The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured
7. hen Heater Electric Your product is covered by a free 2 year parts and labour guarantee Heating Before switching the heater on please ensure the F T ra facia grille is free from obstruction FAN ON OFF Ensure your fused spur is switched ON Set the z thermostat if fitted to the desired temperature 1 KW ON OFF Set the upper fan switch and the middle 1kW switch to ON If you require a faster warm up set the lower 2kW switch to ON 2KWON Il OFF To turn the heater off set the fan switch to OFF Please note all switches must be in the ON position to achieve 2kW heat output For your safety this heater is fitted with automatic overheat protection If the heater stops turn off the power at the fused spur wait 5 minutes and switch the power back on Set the thermostat if fitted to maximum Set the fan switch to ON Ensure the 1kW and 2kW switches are OFF The heater will provide a cooling flow of air Fault Finding This heater is covered by a free 2 year parts and labour guarantee Please refer to the Fault Finding section on page 9 for advice In the event of difficulty please contact us on 01245 324560 0909 Manufactured by Smith s Environmental Products Ltd Blackall Industrial Estate South Woodham Ferrers Chelmsford Essex CM3 5UW Tel 01245 324560 Fax 01245 324422 General Information E mail info smiths env com Web www smiths env com As part of the policy of continuous prod
8. ill flow 6 Balance the central heating system if this heater is installed on the same circuit as panel radiators When the installation is working correctly remember to reset any room thermostat s to its normal setting 6 Position heater making sure the flexible hoses are not kinked and the electrical cable is not snagged 7 Fix heater to plinth lle WANN IN GRILLE TO PLINTH SECURING SCREWS Fault Finding 1 No heat output on settings and Il ELECTRICAL 7 CABLE er 7a If required fit the overlay grille Remove the screws holding the fixed grille to the plinth place the overlay grille over the fixed grille and refit the screws INSTALLED UNIT N POSITION nat OVERLAY GAILLE et a Check the power supply is switched ON b Check fuse in the fused spur c Check the wiring connections at the fused spur d If fitted ensure any room thermostats are calling for heat e Balance the central heating system if installed on the same circuit as panel radiators and increase the circulating pump speed if required f Increase the boiler water temperature In the event of any difficulty please contact us on 01245 324560 It will be more helpful if you do not remove the product from the central heating system Installation Guide The following items should be included in the carton Product complete with fixed grille and pre wired mains c
9. uct improvement Smith s Environmental Products Ltd reserves the right to alter specification without prior notice 04 1095
10. viding the heat output switch is left in the normal I position your heater will switch on and off automatically with your central heating system Hot water from your central heating system passes through a heat exchanger transferring its heat to the aluminium fins Cooler air is drawn in by the fan and heated as it passes through the heat exchanger before being expelled gently back into the room This not only gives a more even temperature spread but will heat a room up in less than half the time of a traditional panel radiator This heater includes an internal thermostat that prevents the fan from operating until the central heating system water passing through the heat exchanger reaches 42 C This prevents the heater circulating cooler air at start up Heating Ensure your central heating is on the switch set to normal I Providing the water temperature in the system is more than 42 C and the thermostat controlling your central heating system is calling HURME for heat your heater will switch on If you require GOFF a faster warm up set the switch to boost II To u a ERST switch off the heater set the switch to O Fault Finding This heater is covered by a free 2 year parts and labour guarantee Please refer to the Fault Finding section on page 5 for advice In the event of difficulty please contact us on 01245 324560 It will be helpful if you do not disconnect the heater from the central heating system Kitc