Home

CAT3-1 User Guide Nov 06.qxp

image

Contents

1. Installation and Operation Contents Mel ETETE l tiwel itiu Uperation 4 New Key Fob Lost Key Fob 8 Troubleshooting 9 A The Acumen CAT3 1 can be j upgraded from the standard key fob to the CAT1 and CAT21 fob with key conversion and LED torch Contact Acumen or your Dealer Spares and Accessories 9 Wiring Diagram Back Cover Installation and Wiring The Acumen GAT3 1 consists of the following main components e CAT3 1 main unit ECU Electronic Control Unit e CAT3 1 wiring harness e 1x Remote Fob e Fitting kit including System fuse spare fuse amp Blue LED system indicator Tool Required e Pliers Cable strippers Cable cutters e Drill with 5 5mm and 8mm bits e Soldering equipment e Adhesive lines heatshrink tubing e High quality insulating tape e Masking tape for drilling LED hole e Multimeter e General workshop tools e Motorcycle wiring diagram CAT3 1 main unit ECU Electronic Control Unit Ensure the fitting of the equipment and the associated wiring does not affect the operation of the motorcycle Be sure the alarm and wiring does not affect moving parts such as control cables brakes and does not touch hot parts The CAT3 1 is designed for motorcycle use and is fully encapsulated so water ingress is not of a concern Likewise the Key Fob is also of a waterproof design We recommend however that the unit is not placed in a position where it is continually subj
2. change of state regardless of how short in time as an alarm and will react accordingly Make sure all connections are sound waterproof and cannot short Operation The visual indications are based on the assumption that the Pink wire Indicators and the Black Red wires LED have been connected See page 3 The standard key fob has three buttons Lock Unlock and Silent To Arm the system Press the Lock button of the fob The alarm will beep twice and flash the indicators twice The system LED will start to flash after 5 seconds and the unit will monitor hot wire accessory switch movement and nudge The system will not arm if the ignition is switched on To Disarm the system Press the Unlock button The system will give one short beep and flash the indicators once NOTE If the system gives one long beep this means the alarm has been sounding Enter diagnostics mode to find the reason why Convenience Ferry Mode In Convenience mode the movement nudge sensor will cease to function With the alarm active press the Silent button You will get one long tone and one flash of the indicators If the LED flashes once per second the movement sensing is active If the LED flashes once every two seconds the movement sensing is disabled You can toggle between Convenience Mode enabled and disabled by simply pressing the silent button Diagnostics Mode It is possible to determine the trigger source that caused the
3. alarm to sound Only the last reason is recorded Diagnostic mode can be accessed two ways a When the alarm is sounding the LED will flash a number of times pause then flash the same number again This will go 30 seconds until the system stops sounding b Alternatively disarm the alarm and then press the silent button The LED will flash a number of times and the system will beep the same number of times Every time you press the silent button the system will flash beep in accordance with the following table Number of Trigger Reason Flashes Beeps 99 No Triggers in last armed period 3 Ignition turned on or hot wired Accessory switch was operated 4 CO E Power was interrupted The CAT3 1 does not have an 2 internal battery but if the power is disconnected when the unit is armed and then re connected it will give a reaction js a ae Additional Features Auto Arm Timer 55 seconds after turning off the ignition the alarm will arm automatically To configure this feature ENTER CONFIGURATION MODE 1 2 Each time you press the button you will get a high pitched bip bip bip Ensure the ingition is switched off The following 3 actions a b and c must be completed within 10 seconds a Arm and disarm the alarm b Switch the ignition on 5 times and leave it on on off on off on off on off on and leave it on c Hold down all three buttons on the fob until the unit emits a rapid low pitch bip bip b
4. instead of two T IS MAI indicate subsequent bip as confirmation except the exit mode which is low pitch ae THAT DIRECTION will not make the unit any less 3 When the nudge sensitivity is set as required press the Silent button Torch on flip fob to exit configuration mode A low pitch bip bip bip bip will confirm NOTE Tilt sensitivity is not affected by nudge sensitivity If the unit is left in user configuration mode for more than 1 minute 30 seconds it will exit automatically and confirm it has done so with a low pitch bip bip bip bip Switching the motorcycle ignition off at any time during the processes above causes the unit to exit configuration with any new completed settings stored The unit will emit a low pitch bip bip bip bip to confirm Additional Features Nudge Alarm Reaction To enable repeated nudging to sound the alarm To configure this feature ENTER CONFIGURATION MODE 1 2 Ensure the ingition is switched off The following 3 actions a b and c must be completed within 10 seconds a Arm and disarm the alarm b Switch the ignition on 5 times and leave it on on off on off on off on off on and leave it on c Hold down all three buttons on the fob until the unit emits a rapid low pitch bip bip bip bip Press the Silent button or torch button on the flip fob three times to access nudge alarm reaction configuration or four times to exit the configuration mode Each time y
5. Intelligent float battery charger Extra external sirens If your CAT3 1 system is buried in the motorcycle the audible warning may not be as loud as you would like This extra siren will allow you to position it where the sound can get out The CAT3 1 can be further upgraded Upon request Acumen will supply you free of charge with a protecting clamshell to prevent easy disconnecting of the alarm system The clamshell will prevent easy unplugging of the 6 way connector Please request Acumen part number C 07 0003 The CAT3 1 also has the ability to be connected to the following optional components 1 Starter immobilisation kit Acumen part number 10113 2 Acumen AlarmMate pager Acumen part number 10114 General Security Precautions While the Acumen CAT3 1 provides state of the art electronic security and protection it will not by itself ensure your motorcycle will not be stolen We recommend you undertake basic security precautions such as Parking in a locked garage if possible Parking in well lit areas if a garage is not applicable Using a bike cover where appropriate Using a chain or shackle and ground anchor Warranty terms and Conditions Full details are given in the Terms and Conditions document www acumen electronics co uk For information on Ja products dealers i FAQ s and one eee 2 y of the best help onan sections in the business CU
6. MIN ELECTRONICS ee e 8 News Crome a Cart Vihar A maad Lola NEW CATS DIY FIT ALARM camer Istent arm the CAT tats OY Me seme a a naw vet tl eg jaaa ACUMEN PLUG IN THE WALL BATTERY TINI tee oe pk amt wn ears to on te team Tag e me mat e memm ne Lay Sia anon nor pos ent teeter fat 7 pata 2 ta tag setis Jo2 0008 3 om T HHIGSSTSAS www acumen electronics co uk Wiring Diagram 12V BATTERY LED 10A FUSE f AO TTT DRILL 8MM DIA HOLE RED STARTER IN BODY PANEL 2 WAY CONNECTOR TEL PURPLE REMOVE ADD ANTENNA NUDGE FACILITY PINK PINK MOVEMENT SENSOR MOUNT VERTICALLY lel GREEN GREEN BLACK WHITE YELLOW MOUNT THE MOVEMENT SENSOR OPTIONALACCESSORY OPTIONAL ACCESSORY PE RTO SO THE WIRE IS VERTICAL IMMOBILISATION PCER 30 DEGREES RELAY TRIGGER SWITCH BROWN IGNITION SWITCH FUSE BOX
7. ONFIGURATION MODE 1 To INCREASE the sensitivity press the Lock button Key button on 1 Ensure the ingition is switched off flip fob Each press of the fob will raise the sensitivity one notch i f KA and is confirmed by a high pitch bip bip 2 The following 3 actions a b and c must be completed within 10 F seconds After each press the motorcycle may be nudged to gauge the sensitivity if the nudge is detected it will emit a single standard a Arm and disarm the alarm beep When the unit reaches it s maximum sensitivity it will emit b Switch the ignition on 5 times and leave it on on off on off one high pitch bip instead of two This will indicate subsequent on off on off on and leave it on presses IN THAT DIRECTION will not make the unit any more c Hold down all three buttons on the fob until the unit emits a sensitive rapid low pitch bip bip bip bip 2 To decrease the sensitivity press the Unlock P button on flip fob 3 Press the Silent button or torch button on the flip fob twice to Each press will give a low pitch bip bip access nudge sensor sensitivity configuration or four times to exit After each press the motorcycle may be nudged to gauge the the configuration mode sensitivity if the nudge is detected it will emit a single standard beep When the unit reaches it s minimum sensitivity it will emit Each time you press the button you will get a high pitched bip bip bip one low pitch bip
8. TY al MELE a NO BLUE AF GNITION SWITCH FUSE BOX MOVEMENT SENSOR mee a aa i TA je g A a Bre MOUNT THE MOVEMENT SENSOR OPTIONAL ACCESSORY SO THE WIRE IS VERTICAL IMMOBILISATION 30 DEGREES RELAY OPTIONAL ACCESSORY OPTIONAL ACCESSORY PAGER TRIGGER SWITCH To get full basic operation of the CAT3 1 System Acumen recommends that you also connect the PINK indicators and Black Red LED wires see page 3 Should you require further options on the CAT3 1 system please see Optional Wiring page 3 Optional Wiring Acumen recommends that the following wires are connected to get full basic operation of the CAT3 1 System however they are not critical to the operation of the system Flashing Indicators The two PINK wires are for the indicators Connect one Pink wire to the LH indicator and the other Pink wire to the RH indicators Ensure you connect these wires to the positive side of the indicators if you connect to the negative side of the indicators the alarm fuse will fail Acumen recommend these connections are soldered Flashing LED The paired Black Red wires with the two way connector are for the LED system indicator Connect the two plugs together Movement Sensing Nudge Facility The two BLUE wires one with a male connector on it one with a female connector are to remove add the nudge facility of the movement sensing e If the two blue wires are conne
9. arm is was reacting b Take appropriate action such as i Enter Convenience Mode if it s a windy day see page 4 ii Check earth power connections if you repeatedly get a power interrupted signal 3 The alarm fuse keeps failing The system cannot blow the fuse It is what the alarm switches that blows the fuse usually the indicators Make sure there are no shorts in the indicator system and if a new fit make sure the alarm PINK wire s is are not connected to the negative side of one or both of the m c indicators Spares and Accessories Acumen can supply a range of spares amp accessories to enhance the features of the CAT3 1 system 1 Spare and replacement remote fobs and batteries 2 The key fob can be up graded to the same flip fob as used on the Acumen Thatcham specification CAT1 and CAT21 systems The Flip fob uses Microchip KeeLog code hopping technology which prevents scanning and recording of transmitter codes When ordering specify Acumen part number 51020 and your make model and year of motorcycle NOTE The Acumen CAT3 1 cannot know both types of fob at the same time If it knows the standard fob it cannot know a flip fob at the same time It can know 2 x standard fobs at the same time or 2 x flip fobs at the same time but not 1 of each 3 Different coloured System LED s to match your motorcycle Green Red White Blue Yellow 4 Acumax 900
10. cted the nudge sensing is added e Dis connecting these two wires removes the nudge sensing Optional Wiring Connections not required for basic operation The YELLOW GREEN wire is the Pager wire It supplies 12v at 0 54 when the alarm is reacting It is designed to connect to the Acumen AlarmMate Pager Acumen Pt No 10114 and or the Acumen external siren Acumen Pt No 10115 IMPORTANT If this wire shorts to Ground while the alarm is sounding the alarm ECU will be damaged The PURPLE wire is the alarm antenna It should be extended along a plastic component and taped into position Do not tape within the wiring harness and do not connect to ground earth The GREEN wire is the trigger wire for the optional Immobilisation relay Instructions for connection are included in the immobilisation kit If you are not using it tape the wire to the main harness in a tidy fashion The WHITE wire is an optional Trigger wire If you need to use this circuit the alarm will trigger if the switch you add to this circuit changes it s state ie open to closed or closed to open Connect the wire to a switch and the other side of the switch to a suitable ground When the switch changes the alarm will sound It can be connected to items such as a magnetic reed seat switch or pressure mat under the m c side stand or the Acumen garage kit See www acumen electronics co uk NOTE If a poor connection is made in this circuit the alarm will interpret any
11. cycle ignition is switched off 1 Ensure the motorcycle ignition is switched off 1 Ensure the motorcycle ignition is switched off 2 NOTE Sections 3 4 and 5 must be completed 2 Remove alarm fuse 2 Remove the alarm fuse within 10 seconds 3 Leave for 5 minutes 3 Leave for 5 minutes 3 Arm and disarm the system from the fob 4 Reconnect alarm fuse and within 10 seconds 4 Replace the alarm fuse the alarm will sound 4 Switch the ignition on off 5 times in quick perform sections 5 amp 6 for 30 seconds unless the system has sounded succession leaving the ignition ON at the 5th 5 Switch the ignition on off 5 times in quick 10 times for power loss in which case there will action succession leaving the ignition ON at the 5th not be an audible reaction but wait 30 seconds 5 Change the state of the accessory switch action Ensure i eee S ee time and circuit WHITE wire ie connect to ground if 6 Change the state of the accessory switch s e alarmis mi triggered by accessory not connected and vice versa The unit will circuit WHITE wire ie connect to ground if SWIGIL Or movemen beep once and enter learn mode not connected and vice versa The unit will 5 Trigger the alarm by turning ON the ignition 6 Press and hold the Lock button until the unit beep once and enter learn mode ae i alarm ua kaa OFF beeps then release it 7 Press and hold the Lock button until the unit beeps en mne siren stops alter 34 seconas ie OA i during the qui
12. ected to water and or pressure washing Siting positioning the CAT3 1 main unit ECU Electronic Control unit When mounting the unit use the 5mm screws nuts supplied in the fitting kit or cable tie the unit to a suitable frame tube Take care to mount the unit where access to it is protected the more difficult it is to reach the harder the job the thief has to bypass the alarm Route the wiring alongside the motorcycle wiring and tape it in the style of the original motorcycle wiring Siting positioning the LED system Indicator Be aware the LED will result in a small increase of electrical current drain The LED draws 1mA of electrical current The LED provides a visual indication of the alarm s status helps with the diagnostic mode of the alarm and will warn a potential thief that your motorcycle is alarmed and that the alarm is armed For this reason it is preferable to position the LED where it can be easily seen Having decided on a suitable position drill an 8mm hole pass the LED through from the back of the hole and then insert the LED into the LED holder Then push the LED holder back into the 8mm hole to mount it securely Route the LED wires to the position of the CAT3 1 ECU The alarm has a loom which ends in a 6 way connector This connector connects to the wiring loom which is connected to the motorcycle Movement Sensor Mount the movement sensor so the wire is vertical 30 degrees No other setting or ad
13. et time you have 10 seconds to 7 The unit will beep twice then release it perform steps 6 amp 7 8 Press and hold the Lock button again and the 8 The unit will beep twice 6 Switch the ignition on and off 5 times leaving unit will beep three times 9 Press and hold the Lock button again and the the ignition ON at the fifth action j unit will beep three times 7 Change the state of the accessory switch circuit WHITE wire ie connect to ground if not connected and vice versa The unit will beep once and enter learn mode 8 Press and hold the Lock button until the unit beeps then release it NEW REPLACEMENT UPGRADED KEY FOBS CAN BE ORDERED 9 The unitwill beep twice DIRECT FROM ACUMEN 10 Press and hold the Lock button again and the www acumen electronics co uk unit will beep three times Troubleshooting 1 The alarm will not react to the fob a Check the fob batteries type CR2016 b Place the fob as near as possible to the alarm system main unit If it will now disarm there are probably spurious radio signals in the vicinity Move the motorcycle to another area c Check the system fuse If the alarm has no power it cannot power the radio receiver Switch on the motorcycle ignition if it disarms now the alarm s power supply is at fault fuse or connections 2 False alarms Remember The alarm may think it is being stolen which is different to it being faulty a Enter Diagnostic mode and find out why the al
14. ip bip Press the Silent button or torch button on the flip fob once to access auto arm timer configuration or four times to exit the configuration mode bip as confirmation except the exit mode which is low pitch Once this option has been selected changing it is accomplished as follows To switch ON the auto arm press the Lock button key button on flip fob and unit emits a high pitched bip bip To turn the action OFF press the Unlock button P button on flip fob and the unit emits a low pitch bip bip It doesn t matter if you don t know the current state of the alarm just press the button you want it to be You can press it again it won t cause a problem When you have the alarm set as you want press the Silent button Torch button on flip fob and a low pitch bip bip bip bip will confirm the programming has ended If the unit is left in user configuration mode for more than 1 minute 30 seconds it will exit automatically and confirm it has done so with a low pitch bip bip bip bip Switching the motorcycle ignition off at any time during the processes above causes the unit to exit configuration with any new completed settings stored The unit will emit a low pitch bip bip bip bip to confirm Additional Features Nudge Sensor Sensitivity To increase or decrease sensitivity of the nudge sensor To configure this feature Once this option has been selected changing it is accomplished as follows ENTER C
15. justment is required The nearer the centre of the bike laterally the less sensitive it is X Mount the movement sensor so the wire is vertical Installation and Wiring Connect the system wires as follows A larger version of the wiring diagram can be found on the back page The RED wire is the alarm positive feed DO NOT connect this directly to the motorcycle battery but connect to the positive terminal of the starter solenoid Use the Red tagged ring terminal from the fit kit The BLACK wire is the alarm negative connection Connect this wire to a suitable earthing point on the motorcycle frame DO NOT connect to the battery negative terminal Do NOT connect it to a sub frame or fairing frame An ideal spot is the connection of the motorcycle battery negative lead amp frame Use the Blue tagged ring terminal from the fit kit The BROWN wire should be connected to a circuit which becomes live when the ignition is switched on Ideally this should be connected between the ignition switch and the motorcycle fuse box If this is not practical a good place is the feed to the rear brake light switch Acumen recommends this connection is soldered Connect the 6 way connectors together and proceed to Operation To make the alarm active you only need to connect the Red Black and Brown wires 12V BATTERY DRILL 8MM DIA HOLE STARTER IN BODY PANEL PURPLE REMOVE ADD ANTENNA NUDGE FACILI
16. ou press the button you will get a high pitched bip bip bip bip as confirmation except the exit mode which is low pitch Once this option has been selected changing it is accomplished as follows 1 To enable repeated nudging to sound the alarm press the Lock button Key on flip fob The unit emits a high pitch bip bip To disable press the Unlock button P on flip fob and unit emits a low pitch bip bip It doesn t matter if you don t know the current state of the alarm just press the button you want it to be You can press it again it won t cause a problem When the nudge alarm reaction is set as required press the Silent button Torch on flip fob to exit configuration mode A low pitch bip bip bip bip will confirm If the unit is left in user configuration mode for more than 1 minute 30 seconds it will exit automatically and confirm it has done so with a low pitch bip bip bip bip Switching the motorcycle ignition off at any time during the processes above causes the unit to exit configuration with any new completed settings stored The unit will emit a low pitch bip bip bip bip to confirm New Key Fob Lost Key Fobs If the system is dis armed but you don t have a working fob you have lost all working fobs If the system is armed and you don t have a working fob you have lost all working fobs If you can disarm the system ie you have a working fob and need to add another 1 Ensure the motor

Download Pdf Manuals

image

Related Search

Related Contents

18 superbes activités mathématiques en environnement  Student User`s Manual for the NEW Student Information System  User Manual RapidStart™  Brodit 512409 holder  Sony VAIO VPCSB31FX  

Copyright © All rights reserved.