1. in an environment that respects the operating temperatures of the AIVIA You must monitor and follow up alerts related to temperature The characteristics of the AIVIA are subject to changes without notice The manufacturer of the AIVIA reserves the right to change products at any time including unlimited modifications to previously delivered products The AIVIA brand is a registered trademark Safety e To avoid risk of fire or electric shock the AIVIA should not be exposed to any naked flame e Leave a space of at least 13 cm around the AIVIA to assure proper ventilation e Keep the AIVIA away from radiators or any other heat source Do not place the AIVIA near any devices that generate heat Do not place anything under the AIVIA e To avoid damage do not insert objects into any of the openings in the AIVIA e Never install the AIVIA in direct exposure to sunlight e Do not expose the AIVIA to any moisture when the door is open e The fixations must be adapted to the type of surface on which the AIVIA is fixed e The manufacturer cannot be held liable for improper installation or in the case of accident or injury during its installation Warranty Do not disassemble the various elements that constitute the AIVIA Do not insert any objects into any openings Only qualified personnel may carry out repairs on the AIVIA Failure to comply with this will void any warranty Any operation or assembly procedu
2. maintenance user code Shut down the Aivia power supply Open the Alvia Switch on the Alvia the white indicators will be illuminated Set the User Maintenance code as described in the Setting up the Aivia section Close the Aivia RUNE e Red indicators blink in a repeated way Number of blinkings Cause Solution E a Failing memory Contact your distributor MA Parameters lost Set up the Aivia again a ae Temperature sensor breakdown Contact your distributor st gt temperature reached Check the AED is working correctly if needed contact your distributor a Aivia has been opened Check AED operates correctly and presence of all the accesso ries if needed contact your distributor e Aivia motorization doesn t work Withdraw the cap off the aivia door and push back the door blocking axle with a stem 11 Notes Electrical Installation Power supply unit Mains grid 230 VAC 50Hz Power supply SOMA 24VDC 3A CLASS I L I I l I I I l I I l I I l l I l I Power Supply Unit Must be located outside the Aivia never installed inside the Aivia e The power supply block must include e A 10A 30mA residual current device serving both to protect and disconnect the hardware e A SELV or equivalent 24VDC 2 3A Class 1 TT Earthing system with limited power output and IEC 60950 1 conform e The cable connecting the residual current de
3. ANIVJIZA210 A MIP 210 Installation and user guide OO 00 00 00 OJO General Information Important Read this manual before installation and use of the Aivia Read this section carefully and follow the instructions The warranty does not cover damage caused by failure to follow these instructions AIVIA PROTECTION are wall mounted protection units that serve to house and shelter AEDs The AIVIA PROTECTION does not ensure control of the AED it is the sole responsibility of the DISTRIBUTOR to inform their own SUB DISTRIBUTORS and USERS of their obligation to verify the presence and operating status of the AED by carrying out regular on site checkups Depending on the options chosen the AIVIA PROTECTION can trigger a visual and sound alarm The alarm is intended as a warning signal in case of any malfunction but no data log of malfunctions is recorded In no event can the presence and operating status of AEDs in an AIVIA PROTECTION be controlled from a distance The AIVIA should in no case be a substitute for the checks and inspections recommended by the manufacturer of the defibrillator Installation must be carried out by a qualified operator or authorized by the Aivia s manufacturer Never install an AIVIA in direct exposure to sunlight The unheated AIVIA must be installed in a temperate environment in accordance with the manufacturer s specifications for the defibrillator The heated AIVIA must be installed
4. efibrillator e Do not place the defibrillator back inside the AIVIA be fore reactivating it e Follow the instructions in the defibrillators manual to reset it for use e The manufacturer may be able to help reactivate the defibrillator Please feel free to contact them e After reactivating the defibrillator replace it inside the AIVIA using the instructions in the section Setting up the defibrillator Aivia maintenance e Wash the Aivia surfaces using a wet cloth Wipe the Aivia with a clean amp dry cloth Do not use washing or chemical products they could damage tt e Do not rub the Aivia with any hard object you might damage it permanently or streak it e Do not use a high pressure cleaner 10 In case of malfunction e White indicators do not light up when the aivia is switched on Check the wiring polarity Check the power supply cable connection Check the voltage 24V at the connector block Check the insertion of the connector block Contact your distributor a ae e White indicators do not blink in night operation 1 Check the aivia power supply 2 Contact your distributor e Red indicators do not blink when the door is being opened 1 Check the aivia power supply 2 Contact your distributor e Siren does not works when the door is opened 1 Check for the siren option on the Avia identification plate 2 Check the aivia power supply 3 Contact your distributor e do not know my
5. g a philips screwdri ver Installing the AED e Pull the holding strap and insert the AED behind the strap 1 AED to be inserted vertically 2 AED holding strap e The strap allows for a simple extraction of the AED while ensuring the AED is securely held Setting up the Aivia The Alivia is setup in maintenance mode In order to do so power up the Aivia with the door open or type the maintenance code on the Keyboard Aivia keyboard All the entries are validated by the key A high pitched beep validates the entry whereas a low pitched beep signals an invalid entry Door opening codes e Modifiying the user code The user code allows the opening it is by default set on 0000 Type the menu code 03 then validate nn the new user code on 4 digits then validate e g 2222 e Modifying the maintenance code The maintenance code allows the opening and once opened the Aivia set up The default value is 1111 Type the menu code 04 then validate Type the new maintenance code on 4 digits validate e g 3333 Alert temperatures then e Low temperature alert entry Heating option If this threshold is reached The aivia will flash 4 times to indicate a temperature alert Type the menu code 101 then validate Enter the low temperature alert threshold e g 5 C You can enter a negative temperature using the key e High temperature alert entry Heating option If thi
6. ion holes 24V DC Cables passage Installation e Fixing must be adapted to the type of support the Alvia is being fixed on e Aivia fixing must be able to carry a minimal load of 20 kg 44lb e Fixing example Supporting wall Pin Nylon plug Fixing screw M6 minimum M8 maximum Washer 14mm 0 55 in maximum e Washer plus screw head thickness must not exceed 8mm 0 31 in Slide all the required cables through the hole before fixing the Aivia to the wall Affix the Aivia using the 3 fixation holes Connect power to the Aivia The Aivia must be supplied with 24VDC power ensure compliance with the Electrical Installation section 1 Access door mounting screws 2 Electronics access door e Unscrew the fixing screw with a Philips screwdriver and pull out the hatch from the top Connect the power supply to the Aivia e The Aivia must be powered using 24V DC see the Power supply section e Slide the power supply cables through the cable passage Cable passage Power supply cables 24V e Connect the cables on the connector block respecting the polarity 1 24V DC Red cable 2 OV Black cable e Plug the connector block onto the board Board power supply connector e Check the power supply to the Aivia by verifying that the white indicators are illuminated Installation e Put back the hatch inserting the lower part first e Screw the hatch fixing screw usin
7. iren option Minimum 55 mA Maximum 500 mA Sound level 90 105 dB 1 meter e X2A210 XX001 heating option Minimum 55 mA Maximum 2000 mA e X2A210 XX101 siren and heating option Minimum 55 mA Maximum 2400 mA Sound level 90 105 dB 1 meter e Operating temperatures and humidity Minimum 20 C 4 F Maximum 55 C 131 F without battery option 40 C 104 F with battery option Relative humidity 95 without condensation e Temperature alerts Low temperature alert 5 C 41 F High temperature alert 40 C 104 F e Heating option References X2A220 XX001 or X2A220 XX101 Heating thresold 10 C 50 F by default Fan thresold 30 C 86 F by default e Maximum weight capacity 5Kg 11 Ib e Maximum altitude 2000 m Compliance X2A210 XX EN 55022 2006 EN 55024 1998 A1 2001 A2 2003 EN 60950 1 2006 14 Notes www aivia eu 2013 07 03 IP210 EN 204 A M info aivia eu
8. king care to not leave marks on the Aivia _ pce tado td la 1 e Repeat on the other side of the Alvia Installation Aivia installation Never install an Aivia in direct exposure to sunlight You risk exposing the defibrillator to excessive temperatures e Installation must be carried out by a qualified operator who adheres to the Bornavie charter or authorized by the Aivia manufacturer e If the Aivia is installed in a public street or place with public access install a fixed ground plate abutment or column e Fixations must be suitable for the type of surface which the Aivia is attached to e Aivia working zone must be kept free as specified above e The exact dimensions of the Aivia are provided at the end of this document in the Specifications section e Make sure that every cable has been taken through the cable passage before affixing the Aivia to the wall Useful area for Aivia working space 4 I I 1 220 mm 190 mm 220 mm s 8 66 in 7 48 in 8 66 in Oo O ey 285 mm l l l l i l e Let a free space of 140 cm 55 11 in in front of the supporting wall to allow for easy opening of the Aivia Useful area for Aivia working space i EEE YS mz mz By e To mark fixations and cable passageway use the drilling template provided with the packaging e Put the template against the wall with the arrow facing upwards and towards you Fixat
9. n of the Alvia Heating option operation e The heating option allows to maintain the AED operating temperature within working temperatures In extreme cold temperatures it is worthwhile checking that the alert temperature is not signaled by the flashing of the red indicators e The fan allows the heat to be extracted from the Alvia In hot weather it is worthwhile checking that the alert temperature is not signaled by the flashing of the red indicators Alert operation Door opening alert e When the door is opened the visual alert is given by the flashing of the red indicators e If your Aivia is equipped with the siren option Reference X2A210 XX100 or X2A210 XX101 It will be activated for 3 minutes Temperature alerts e The temperature alert signaled by 4 repeated flashings of the red indicators door close is triggered when the temperature gets below the minimum temperature defined or over the maximum temperature defined Using the Aivia If you witness an incident needing an AED e Contact emergency services Speak using a clear and loud voice describe the situation without forgetting to precise the incident location The user code will allow you to unlock the alivia e Open the Aivia door by pulling it Visual alert is given by the blinking ot the red indicators Mm e Take the AED out 4 e Go to the victim e Switch on the AED Follow the AED s instructions After using the d
10. nction Electrical Installation Specifications Mechanical characteristics Technical characteristics Compliance COM CONNNNOOFK HH AH 10 10 10 10 10 11 13 14 14 14 Installation Important Read this manual with carefully before setting up and using the Alvia Never install Aivia Aivia in direct exposure to sun light You risk exposing the defibrillator to excessive temperatures Aivia presentation Electronic compartment Light sensor Seals support Heating film Night and alert indicators Door Identification plate 8 Fixation holes 9 AED holding sandow 10 Connector reserved for the AIVIA maintenance Connecting a cable to this connector can damage the AIVIA Identification plate e The identification plate is located inside the Aivia Reference Options PYRESCOM Mas des filleuls http www alvia eu 66680 Cahohes info aivia eu 33 0 4 68 66 39 68 Sirem Alarm Chauftage Heating RTCISTN GPRS Capteur DAE AED sensor Aivia 210 X2A210 XX101 24VDC 3A Max S N 1214P466 Serial number e In the event you need to reach customer services or your distributor please make sure you have your Aivia reference and serial number available First opening e To open the Aivia door before it is fixed on the wall use a small screwdriver e Slip the screwdriver between the door and the chassis of the Aivia e Pull up the screwdriver ta
11. res expressly prohibited or not recommended by this manual will also void the warranty Environmental information e When returning the AIVIA you should only use the original packaging e Do not dispose of the AIVIA or its packaging with nor mal household waste Use the collection system in place in your area The use of collection systems will help pre serve the environment and your health The AIVIA can contain batteries in compliance with EU Directives 2006 66 CE and 2008 103 CE These cannot be disposed of with normal household waste Please use the system for collecting used batteries in place in your area The proper disposal of used batteries preserves the environment and your health E Maintenance CAUTION THE AIVIA CONTAINS BATTERIES THERE IS A RISK OF EXPLOSION IF THE BATTERIES SUPPLIED FOR USE BY THE AIVIA ARE REPLACED BY INCORRECT BATTERIES ONLY AN AUTHORIZED OPERATOR CAN CARRY OUT MAINTENANCE OPERATIONS INCLUDING REPLACING THE BATTERIES Summary Installation Important Aivia presentation Identification plate Initial opening Aivia installation Connecting the power supply to the Aivia Installing the AED Setting up the Aivia Door opening codes Alert temperatures Heating Fan activation temperatures Close the AIVIA door Pictograms Use Night mode operation Heating option operation Alert operation Using the Alvia After using the defibrillator Aivia maintenance In case of malfu
12. s threshold is matched The aivia will blink 4 times to indicate a temperature alert Type the menu code 102 then validate Enter the high temperature alert threshold e g 30 C Installation Heating Fan activation temperatures e Entering the heating temperature Heating option Heating will be triggered once this threshold is matched lt will stay activated as long as the temperature has not become warmer than the threshold Type the menu code 103 then validate Enter the heating threshold e g 10 C You can enter a negative temperature using the key e Entering the fan activation temperature Heating option Fan activation will be triggered once this threshold is matched It will stay activated as long as the temperature has not got colder than the threshold Type the menu code 104 then validate Enter the fan activation threshold e g 35 C Close the AIVIA door e Completely close the Aivia door Be sure to pull the door base toward you before shutting the door Pictograms e The signs on the door of AIVIA inform you of what to do in case of emergency e You must mark the emergency number to call in the SOS pictogram if one is not already noted there e Check that the instructions stay clear and unmasked Notes Use Night mode operation e The Aivia is equipped with a light detector In low ambient light blinking white lights help identify the locatio
13. vice and the power supply must be a section of 1 5 mm e The mains connection must include the primary phase neutral and earth e The maximum full load secondary voltage drop must not exceed 2 or 23 5V at the Aivia terminal e The power block must be dust and water proof and ventilated Wires must be held against themselves by a collar at the nearest of the holding terminals The power block wiring must conform to standards in force in the country of use Recommended power supply PYRESCOM C_AL DR75 24 Natural or forced convection depending on the environnment and thermal characteristics at maximum load www aivia eu doc A DPM html SELV Wiring e U1000R2V Type 2 Isolated and gained conductors 1 5mm gauge 10 meters maximum length For the 24V wiring use a red or brown cable For the OV wiring use a black or grey cable 13 Specifications Mechanical characteristics e Weight e X2A210 XX000 2 9 Kg 6 39 Ib e X2A210 XX100 siren option 3 1 Kg 6 83 Ib e X2A210 XX001 heating option 3 Kg 6 61 Ib e X2A210 XX101 siren amp heating option 3 3 Kg 7 27 Ib e Composition e Door Polycarbonate e Chassis ABS e Square ABS e Hatch ABS Technical characteristics e Power supply 24 VDC 2 3A SELV source to limited power complies with IEC 60950 1 e Current consumption e X2A210 XX000 Minimum 55 mA Maximum 200 mA e X2A210 XX100 s