Saltlre STl — INSTALLATION AND OPERATING INSTRUCTIONS

image

Contents

1. i 4 a ty ui G ee 5 5 Y 3 01273 697288 07944 289 849 www hanoverbuilder co uk S Q 2 5 we La D gt Q co Ea
2. Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke contro areas have been authorised in Regulations and that appliances used to burn solid fuei in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The Saltfire ST1 has been recommended as suitable for use in smoke control areas when burning seasoned wood Further information on the requirements of the Clean Air Act can be found here http smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements FUEL Wood All types of wood are suitable provided they are wells seasoned UNTREATED and have a moisture level between 12 and 20 For soft woods typically they will need to have been left in suitable storage for 9 months in order for the moisture to evaporate For hardwoods this will usually be 18 months It is recommended that logs should be no more than 5 or 1
3. in smoke control areas when used in accordance with these instructions WARNING The high temperature paint covering the stove will give off some fumes during the initial few uses of the stove The fumes are non toxic but some people may find them unpleasant Ensure the area is well ventilated during this period The output ratings of this stove are based on around 1 5kg of seasoned logs which would require refuelling every hour This stove is suitable for intermittent burning and should not be used constantly for extended periods Not suitable for overnight burning Under certain abnormal weather conditions e g down draughts it may be difficult to get sufficient draw through the appliance to achieve good combustion When this happens the stove should not be used CLEANING MAINTENANCE Regular cleaning of the stove is essential for safety and efficiency The ash pan should be emptied at least after every use and during use if burning for longer periods When cold the inside of the stove should be given a regular sweep out The flue and flue pipe will require cleaning with a suitable chimney brush to minimise build up of soot and tar You chimney will also require periodic sweeping Your stove is built with an integrated baffle plate inside which cannot be removed for this reason sweeping of the chimney needs to be done via an access door in the flue pipe so it is important that a flue pipe with access door is fitted at the
4. to die add a further three larger pieces of wood weighing approx 1kg Once theses logs are alight and after about 7 minutes or so a normal load of 3 logs weighing approximately 1 5kgs in total can be added e Once this load is burning well the Primary and Secondary vents can be altered according to your required burn rate and chimney draw strength Refuelling Open the Primary air vent fully Add up tol Skg of wood After about 2 minutes or when flames from the fresh fuel fully established reduce the opening of the Primary vent At high power output your stove will require refuelling approximately every hour It is important to follow these instructions in order to achieve clean burning and to maximise the efficiency of the stove e Do not leave the fire unattended until flames are well established an the newly charged logs e Always refuel onto hot embers e If the fire has died out at the point of refuelling use kindling to re establish the fire and follow the Ignition procedure above e It is important that the stove is not overloaded with fuel e Reduced burn rates can be achieved by reducing the openings of the Primary and Secondary air vents e Operation with the door open can cause excessive smoke The appliance must not be operated with the door left open except as directed in the instructions above UK Clean Air Act 1993 Smoke Control Areas The Saltfire ST1 wood burning stoves are suitable for use
5. 25mm in diameter Logs should be no more than 260mm in length If you are unsure of the moisture content of your fuel then you can buy a moisture meter which will indicate the moisture levels in your fuel Liquid fuels must NEVER be used WARNING Wet timber should not be used as this will create excess tar deposits in the chimney and stove and could increase the risk of chimney fire Timber which is not of a suitable moisture content will also create more smoke and harmful emissions Never use your stove as incinerator to burn waste or rubbish AIR INLET CONTROLS Your stove has two air inlet areas pper vent provides air supply for the glass air wash system this is called the Primary air when this vent is open the f glass is kept clean by high speed air rushing downwards across the inside of the glass By moving the Primary vent knob the left airflow into the stove is increased The second air inlet is located under the door and is called the Secondary or sometimes called the Tertiary air supply Moving the lever to the left increases the airflow into the stove The air is then channelled through a chamber under the stove and to the rear of the firebox and enters the firebox via a series of small holes at towards the back of the firebox Both air inlet controls are designed such that they cannot be fully shutdown This is necessary to aid a clean combustion and comply with appliance exemption via DEFRA TOOLS The glove is prov
6. Fire Cement Access should be provided for cleaning the flue gas connector and chimney flue to ensure that the passageways for exhaust gases remain free from obstruction Your stove is built with an integrated baffle plate inside which cannot be removed for this reason sweeping of the chimney needs to be done via an access door in the flue pipe so it is important that a flue pipe with access door is fitted at the installation stage If there is not sufficient clearance above the stove for this then there needs to be a suitable alternative access method incorporated at the time of installation We recommend that you have a qualified fitter install your stove The British recognised standard for solid fuel installations is HETAS You can find a HETAS qualified installer in your area by going to the HETAS website www hetas co uk OPERATING INSTRUCTIONS The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural
7. Saltire ST1 INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION SAFETY Safety is the most important consideration when using and installing your stove If not installed and used correctly a house fire could result Installation must comply with relevant national and local Building Regulations and fire safety standards IN THE EVENT OF CHIMNEY FIRE EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES Your stove will be heavy and care needs to be taken when lifting 2 people will normally be required to lift UNPACKING Your stove will have several of its components stored inside the stove itself for transportation Do NOT drag the stove on its legs it must be carefully lifted into place Inside you will find a glove which must be used when opening the door or when adjusting air vents when the fire is hot INSTALLATION Installation of your stove must comply with relevant local and national Building Regulations and fire safety standards TECHNICAL Model Saltfire ST1 Nominal heat output 5kW Gross Weight of Stove inclusive of packaging 50 kg Net Weight of Stove 46 kg Max Height 495 mm Max Width 460 mm Max Depth 310 mm Flue Diameter 125mm 5 Mean flue gas temperature directly downstream of the flue spigot 243 degrees C with closed doors Flue gas mass flow 3 3g s Mean CO emission at 13 Oxygen 0 27 Net Energy Efficiency 83 6 The stove must not be installed within the s
8. ided for adjusting the air inlets and for opening the door when the stove is hot as these knobs will heat up when in use NOTE all parts of the stove will become hot during use and care needs to be taken to avoid injury through burning The tool handle provided is for removing the ash pan LIGHTING THE FIRE Prior to lighting the fire for the first time ensure that Installation and building work is complete The chimney is suitable and sound and has been swept and free from obstruction Adequate ventilation and provision for combustion air has been made That the stove installation has been carried out in accordance with Building Regulations and any applicable local regulations as well as these installation instructions e That chimney draw has been checked and within specification The stove has been tested at nominal output with a flue draught of 12 Pa ENSURE THAT YOU HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE AND THAT YOU ARE CONFIDENT THE STOVE HAS BEEN INSTALLED CORRECTLY ALWAYS WEAR A PROTECTIVE GLOVE WHEN REFUELLING YOUR STOVE Ignition Ensure all air inlets are fully open Construct a pile of kindling in the middle of the grate using approximately 1kg of kindling wood Light with a single chemical firelighter Partially shut the door but leaving it cracked open slightly After about 5 minutes or when the fire is well established shut the door After a further 3 5 minutes as the fire starts
9. installation stage If there is not sufficient clearance above the stove for this then there needs to be a suitable alternative access method incorporated at the time of installation If the glass becomes stained from the inside the air wash vent may need opening more during use The glass can be cleaned with a cloth and chemical stove glass cleaner or the glass cleaning pad made by Schott The high temperature paint which your stove is finished in should last many years with normal use but when it does eventually require re finishing black heat resistant paint in spray cans can be purchased from most hardware stores Do not use regular paint which is not high temperature resistant After prolonged periods of not using the fire the stove and flue system should be checked for blockages prior to re lighting We recommend regular servicing and safety checks are carried out by a qualified engineer There must be no unauthorised modification of the appliance Use only replacement parts recommended by the manufacturer What to do in the event of a chimney fire e cut off the air supply to the stove i e close the primary and secondary air supplies e move any combustible materials well away from the stove e get everyone out safely e make sure that the fire brigade has clear access e call 999 If you have any questions or concerns regarding the safe use of your stove please contact us a a S v O 8 D fad G o c S a Ka S
10. pecified minimum distances to combustible materials A gap of at least 400mm needs to left between the stove and any combustible materials at the sides and 500mm to the rear Adjacent walls should be of non combustible materials and construction preferably masonry or brickwork Your stove will require a constant air supply and should not be used at the same time and in the same room space as extractor fans or any device which may draw air supply away from the stove _ The stove should be installed on a level floor with adequate load bearing capacity The stove needs to stand on a hearth of non combustible materials not less than 12mm thick conforming to Building Regulations Your stove output is low enough that in older properties dedicated external air supply does NOT have to be incorporated HOWEVER in very airtight houses those with air permeability less than or equal to 5 0m3 h m2 a vent to from the room to the outside of the house should be fitted to ensure a constant air supply for combustion It should consist of a total free area of at least 2750mm72 The vent should be positioned such that it is not liable to blockage NOT suitable for installation in a shared flue system If installed in a standard type chimney a register plate needs to be fitted inside the chimney When purchasing flue pipe 5 diameter is required The flue pipe must be fitted INSIDE the flue spigot and sealed wit generous amount of