Installation and operating instructions pumped electric shower

image

Contents

1. FOR EASE OF SERVICING THE UNIT MUST ALVVAYS BE MOUNTED ON THE SURFACE OF TILED VVALLS NEVER TILE UP TO THE UNIT Refer to Fig 6 for correct siting of shovver Position the unit vyhere it vvill not be in direct contact vvith vvater from the shovverhead Position the shovver unit vertically Allow enough room between the ceiling and the shower to access the cover top screws Note Water Regulations shower hose connections requires the showerhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25 mm above the spill over level of the relevant bath shower tray or other fixed appliance The use of the supplied soap dish will in most cases meet this requirement but if the showerhead can be placed within a bath basin or shower tray then a double check valve or similar must be fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which complies with European standards The PRD provides a level of appliance protection should an excessive build up of pressure occur within the shower Do not operate the shower with a damaged or kinked shower hose or a blocked showerhead which can cause the PRD to operate When commissioning the showerhead must be removed from the flexible hose while at the same time the temperature control must be at the minimum flow position Failu
2. cover is two wire lead The socket on the end of this lead must be connected to the plug that is situated at the bottom of the right hand side of the backplate unit fig 19 Note The plug and socket can only fit one vvay Replace the cover squarely to the backplate and guide into position so that the controls locate correctly into the spindles while at the same time checking the wires are not trapped Should any difficulty arise recheck the points above Secure the cover temporarily in position with the three retaining screws DO NOT OVERTIGHTEN Switch on the mains electric supply to the shower at the isolating switch Press the START STOP button fig 20 The power indicator will light and the pump starts to operate It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being flushed from the shower When a smooth flow of water is obtained rotate the temperature control from 1 to 10 several times fig 21 to release any trapped air within the unit Once flushing out has been completed stop the water flow by pressing the START STOP button SWITCH OFF THE ELECTRICITY SUPPLY TO THE SHOWER AT THE ISOLATING SWITCH Unscrew the three retaining screws again and lift the cover from the backplate Remove the locking screw from the power selector spindle fig 17 and store for future use Make sure the selector spindle is left in the same position Rep
3. COLD water only Adjusting the temperature control at this setting will only increase or decrease the force of the water from the showerhead It will not alter the water temperature Red outline symbol is the LOW setting for extra economy during hot months Temperature adjustment at this setting is via the temperature control Single red symbol is the MEDIUM setting for economy during warmer months and any temperature adjustment at this setting is via the temperature control Double red symbol is FULL power setting which allows the highest flow achievable for your preferred temperature Temperature adjustment at this setting is via the temperature control To adjust the shovver temperature The shovver temperature is altered by increasing or decreasing the flow rate of the water through the shovver via the temperature control After obtaining your preferred shovver temperature the number can be remembered as the normal setting and should only need to be altered to compensate for seasonal changes in ambient vvater temperatures To decrease the shovver temperature Turn the temperature control anti clockwise towards the lower numbers this will increase the water flow To increase the shower temperature Turn the temperature control clockwise towards the higher numbers this will decrease the water flow Note Be certain the showering temperature is satisfactory by testing with your hand before stepping under the showerh
4. button is pressed FAULT FINDING IMPORTANT Switch off the electricity at the mains supply and remove the circuit fuse before attempting any fault finding inside the unit Cause 1 1 Interrupted power supply 1 2 Plug not connected to socket inside the cover 1 3 Solenoid valve malfunction 1 4 Pump motor faulty Action Cure 1 1 1 Check if a general power cut Check other appliances and if necessary contact the local Electricity Supply Company 1 1 2 If the power neon does not illuminate when the Start Stop button is pressed check the consumer unit fuse or circuit breaker or isolating switch If blown or faulty renew or reset as applicable If it fails again consult a competent electrician 1 2 1 Remove the cover and ensure the plug and socket are firmly connected 1 3 1 Have solenoid checked by a competent electrician or contact Customer Service 1 4 1 If the power neon is lit when the Start Stop button is pressed have the pump checked by a competent person or contact Customer Service 2 Water too hot 2 1 Not enough water flowing through the shower 2 2 Increase in ambient water temperature 2 1 1 Increase the flow rate via temp control 2 1 2 Blocked showerhead clean or replace showerhead 2 1 3 Blocked filter see filter maintenance 2 2 1 Switch to reduced power setting and readjust flow rate via temperature control to give the required temperature 3 Water te
5. money order 2 By telephone quoting credit card MasterCard or Visa details 3 By website order www tritonshowers co uk TRITON STANDARD GUARANTEE Triton guarantee this product against all mechanical and electrical defects arising from faulty workmanship or materials for a period of two years for domestic use only from the date of purchase provided that it has been installed by a competent person in full accordance with the fitting instructions Any part found to be defective during this guarantee period we undertake to repair or replace at our option without charge so long as it has been properly maintained and operated in accordance with the operating instructions and has not been subject to misuse or damage This product must not be taken apart modified or repaired except by a person authorised by Triton This guarantee applies only to products installed within the United Kingdom and does not apply to products used commercially This guarantee does not affect your statutory rights What is not covered 1 Breakdown due to a use other than domestic use by you or your resident family b wilful act or neglect c any malfunction resulting from the incorrect use or quality of electricity gas or water or incorrect setting of controls d faulty installation 2 Repair costs for damage caused by foreign objects or substances 3 Total loss of the product due to non availability of parts 4 Compensation for loss of us
6. to prevent overheating Fuses do not give personal protection against electric shock A 30mA residual current device RCD MUST be installed in all UK electric and pumped shower circuits This may be part of the consumer unit or a separate unit Switch off immediately at isolating switch if water ceases to flow during use Other electrical equipment i e extractor fans pumps must not be connected to the circuits within the unit Switch off at isolating switch when not in use This is a safety procedure recommended with all electrical appliances As with all electrical appliances it is recommended to have the shower and installation checked at least every two years by a competent electrician to ensure there is no deterioration due to age and usage INTRODUCTION This book contains all the necessary fitting and operating instructions for your Triton pumped electric shovver Please read them carefully and keep for future reference The shower installation must be carried out by a competent person and in the sequence of this instruction book DO NOT attempt any electrical or plumbing vvork necessary to install this product unless you have good practical experience and adequate understanding of the IEE regulations and water regulations Care taken during the installation will ensure a long trouble free life from your shower SPECIFICATIONS Electrical Nominal power rating at 240V 8 5kW 40A MCB rating 9 5k
7. tools near water The use of a residual current device RCD is recommended Note The control knobs are an integral part of the cover DO NOT attempt to remove them IMPORTANT The unit must be mounted on a flat surface which covers the full width and length of the backplate It is important that the wall surface is flat otherwise difficulty may be encountered when fitting the cover and subsequent operation of the unit may be impaired Unscrew the two top and one bottom retaining screws fig 7 and lift the cover from the backplate Note Deviations from the designated entry points will invalidate product approvals If a top entry is required for the water pipe remove the top cut out in the backplate fig 8 and rotate the inlet elbow so that it points upward If a bottom entry is required for the cold water pipe then a hole will need to be cut out of the cover fig 9 and the inlet elbow rotated to face downward If entry is required from the back rotate the inlet elbow upwards and fit the supplied elbow to connect to the pipe fig 10 Make sure the hole in which the pipe enters through the wall is filled in completely in order to stop any possible ingress of water into the cavity area After choosing the site for the shower use the backplate as a template and mark the three fixing holes fig 11 Drill and plug the wall to suit the fixing screws supplied The wall plugs provided are suitable for most brick wa
8. 5 gallons Stop Gate Mains electric supply valve valve via double pole switch 8cm minimum JI 2 I I ye gt Shovver unit Mains vvater supply Separate permanently connected supply from consumer unit Fig 5 Diagrammatic view not to scale Ne 7 VVATER REQUIREMENTS VVARNINGI Under no circumstances must this T80si pumped shovver be connected directly to the mains water supply The installation must be in accordance with Water Regulations Bylaws To guarantee activating the heating elements the shower must be connected to a cold water supply which is gravity fed from a static cold water storage cistern with a minimum capacity of 114 litres 25 gallons There MUST be a maximum head of water of 10 metres and a minimum head of 8cm as measured between the bottom of the cistern and the top of the shower unit There MUST be no other cold water draw offs between the cistern and the unit and the pipe MUST NOT supply water to any other tap or fitting at a lower level Note The supply pipe from the cistern should be on the opposite side to the float operated valve to prevent air being drawn into the pipe when the cistern is filling If it is intended to operate the shower in hard water areas above 200 ppm temporary hardness a scale inhibitor should be fitted Fig 5 shows a typical system layout DO NOT use jointing compounds on any pipe fittings for the installation SITING OF THE SHOVVER
9. AUTION DO NOT attempt to replace the PRD unless competent to do so screws Note Before replacing the cover it is strongly Outlet pipe advised to prime the unit see commissioning 805 SPARE PARTS Ref Description Part No Motor and pump assembly 840001 20 2 Connecting pipe lovver 7052554 Connecting pipe upper 7052555 Thermal cut out 22010070 Terminal block 22009230 Can assembly 8 5kW 240V 84500810 9 5kW 240V 84500800 6 Selector switch microsvvitch amp wire assy 8 5kW wireset 82500260 9 5kW wireset 82500270 Connecting pipe 7052556 Flow valve assembly 82100300 Solenoid 22009120 10 Inlet pipe assembly 82800600 11 Outlet pipe assembly 85000200 Outlet pipe amp terminal block wiring assy 8 5kW wiring 82200840 9 5kW wiring 82200830 12 Filter 82800620 Pressure relief device 82800450 15mm John Guest stem elbow 22008180 13 Cover assembly c w knobs amp button 84900030 Start stop switch 83305380 Problem Symptom 1 Shovver inoperable no water flow when the Start Stop
10. TRITON T80si pumped electric shower TRITON 7805 Installation and operating instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT VVITH THE USER 2180286 May 2008 T80si pumped CONTENTS Page Important safety information 1 Introduction 2 Specifications 2 Advice to users 2 Main components 3 Electrical requirements 4 Water requirements 6 Siting of the shower 7 Fitting the shower to the wall 8 Plumbing connections 10 Electrical connections 11 Commissioning 12 Operating the shower 14 Operating functions 16 Instructions for installers and service engineers only 17 18 Spare parts 19 Fault finding 20 21 Guarantee service policy etc rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone 0870 067 3767 Facsimile 0870 067 3334 E mail technical tritonshowers co uk 1 2 1 3 1 4 1 5 1 6 b 1 7 1 8 1 9 2 2 2 3 PLEASE READ THIS SAFETY INFORMATION Products manufactured by Triton are safe and vvithout risk provided they installed used and maintained in good vvorking order in accordance vvith our instructions and recommendations WARNING DO operate shower if frozen or suspected of being frozen It must thaw out before using DO NOT operate the unit if the showerhead or spray hose b
11. W 40A MCB rating Nominal power rating at 230V 7 8kW 40A MCB rating 8 7kW 40A MCB rating Water Inlet connection 15 mm diameter Outlet connection V2 BSP male thread Entry Points Water cable bottom top or back Materials Backplate cover controls showerhead ABS Sprayplate Acetal Elements Minerally insulated corrosion resistant metal sheathing Dimensions Height 365 mm Width 245 mm Depth 104 mm Standards and Approvals Splashproof rating IPX4 Complies with the requirements of current British and European safety standards for household and similar electrical appliances Complies with requirements of the British Electrotechnical Approvals Board BEAB Meets with Compliance with European Community Directives CE ADVICE TO USERS IMPORTANT When first installed the unit will be empty It is essential the unit should contain water before the elements are switched on It is vital that the followed commissioning procedure is Failure to carry out this operation will result in damage to the unit and will invalidate the guarantee The following points will help you understand how the shower operates a The electric heating elements operate at a constant rate at your chosen power setting It is the flow rate of the water passing through the heater unit which determines the shower temperature at any given setting The slower the flow the hotter
12. d off to the heating elements preventing any maintained temperature rises Overheat cut out During normal operation if an overheat temperature is sensed power to the elements will be reduced Water will continue to flow When the temperature has cooled sufficiently power to the elements will be automatically restored to the previous setting at the time of interruption Safety cut out The unit is fitted with a non resettable over temperature safety device In the event of abnormal operation which could cause unsafe temperatures within the unit the device will disconnect the heating elements It will require a visit from a qualified engineer to determine the nature of the fault and replace the safety device once the unit has been repaired INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY CLEANING THE INLET FILTER It is recommended that the filter is periodically cleaned in order to maintain the performance of the shovver It is essential that this operation is carried out by a competent person SVVITCH OFF THE ELECTRICITY SUPPLY AT THE MAINS Remove the cover and disconnect the plug There is no need to turn off the vvater supply the act of removing the filter unit automatically isolates the vvater supply Note Should debris be trapped on the shut off seat inside the valve vvater vvill continue to flow out as the filter is removed It is therefore advisable to locate the main isolating valve b
13. e of the product or consequential loss of any kind 5 Call out charges where fault has been found with the appliance 6 The cost of repair or replacement of pressure relief devices showerheads hoses riser rails and or wall brackets isolating switches electrical cable fuses and or circuit breakers or any other accessories installed at the same time 7 The cost of routine maintenance adjustments overhaul modifications or loss or damage arising therefrom including the cost of repairing damage breakdown malfunction caused by corrosion furring pipe scaling limescale system debris or frost d Ne A Triton Showers Triton Road Nuneaton Warwickshire CV11 4NR Triton is a division of Norcros Group Holdings Limited Customer Service 0870 067 3333 Scottish and Northern Ireland Customer Service Fr 0845 762 6591 Trade Installer Hotline Fr 0870 067 3767 Fax 0870 067 3334 www tritonshowers co uk E mail technical tritonshowers co uk Extended Warranty AVAILABLE NOW Call 0870 067 3333 for more details TRITON reserve the right to change product specification without prior notice EROA TRITON SHOWERS 2008
14. e shower must only be connected to a 3 1 The electrical supply must be adequate for 230 240V ac supply If you are installing a the loading of the unit and existing circuits shower with a kilowatt rating above 9kW it 4 Check your consumer unit main fuse box is advisable to contact the local electricity has a main switch rating of 80A or above supply company and that it has a spare fuse way which will 1 1 The electrical rating of the shower is shown take the fuse or Miniature Circuit Breaker on the rating label Fig 3 within the unit MCB necessary for the shower Fig 4 4 1 If your consumer unit has a rating below 80A or if there is no spare fuse way then the TRITON Shepperton Park installation will not be straightforward and Triton Road Nuneaton z Warwickshire CV ANR may require new consumer unit serving MODEL 77777 the house just the shower 230 240V ru 4 2 You will need to contact the local electricit BEAB y MAX PRESSURE IPX4 company They will check the supply and carry out what is necessary Fig 3 5 For close circuit protection DO NOT use a RATED PRESSURE MODEL No 00000000 rewireable fuse Instead use a suitably rated Ena 00000000 J Miniature Circuit Breaker MCB or cartridge S fuse see Table A Fig 4 Schematic of installation circuit 5 1 30mA residual current device RCD must be installed in all UK electric and pumped Pull cord shower circuits This may be part of the isolating switch consumer u
15. ead There will always be a time delay of a few seconds between selecting a flow rate and the water reaching the stable temperature for that flow rate CAUTION It is recommended that persons who may have difficulty understanding or operating the shower controls should not be left unattended while showering Special consideration should be given to young children and the less able bodied WARNING After any servicing of mains water supply always flush out the pipework to remove any debris Always make sure the unit is started on COLD in order to purge any air in the pipework WARNING This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that they do not play with the appliance T80si pumped Fig 23 Q Low Full ON Povver Medium selector povver Temperature control temperature WARNING DO NOT use abrasive or aggressive cleaning products when cleaning the shower as they may damage the unit OPERATING FUNCTIONS Power on indicator fig 23 The power neon will light when the START STOP button is pressed This indicates that power is on to the pump and power selector Low water pressure cut out Should the water pressure fall below the minimum required to operate the shower power will be switche
16. ecomes damaged DO NOT restrict flow out of shower by placing showerhead in direct contact with your body DO NOT operate the shower if water ceases to flow during use or if water has entered inside the unit because of an incorrectly fitted cover WARNING If restarting the shower immediately after stopping be aware that a slug of hot water will be expelled for the first few seconds GENERAL Isolate the electrical and water supplies before removing the cover Read all of these instructions and retain them for later use DO NOT take risks with plumbing or electrical equipment Isolate electrical and water supplies before proceeding with the installation The unit must be mounted onto the finished wall surface on top of the tiles Do not tile up to unit after fixing to wall Contact Customer Service see back page if any of the following occur If it is intended to operate the shower at pressures above the maximum or below the minimum stated If the unit shows a distinct change in performance If the shower is frozen If it is intended to operate the shower in areas of hard water above 200 ppm temporary hardness a scale inhibitor may have to be fitted For advice on the Triton Scale Inhibitor contact Triton Customer Service The showerhead must be cleaned regularly with descalent to remove scale and debris otherwise restrictions to the flow on the outlet of the unit will result in higher temperatures and cou
17. efore removing the filter in the event that the unit needs isolating DO NOT rely on the filter shut off valve vvhen carrying out repairs or service to other areas of the shovver unit Unscrew the filter fig 27 by turning anti clockwise Remove the unit complete with the filter and wash under running water Make sure all debris etc is removed Replace by pushing the unit back into its housing until the threads engage and then turn fully clockwise until tight DO NOT OVERTIGHTEN Before replacing the cover it is strongly advised to prime the unit by opening the bleed screw until water drains from it Close the bleed screw and connect the plug to the cover Replace the cover and secure with the fixing screws Switch on the electric supply and start the shower on the COLD SETTING ONLY and with the temperature control rotated fully anti clockwise When a smooth flow of water is obtained the shower can then be used in the normal manner 805 pumped INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY REPLACING THE PRD The PRD is situated behind the outlet pipe fig 28 To access the PRD FIRST SVVITCH OFF THE ELECTRICITY SUPPLY then unscrevv the hose and remove the cover Remove the four screws securing the outlet pipe Four in position Carefully pull avvay from the can and outlet pipe then unscrew the two screws holding the PRD to screws the outlet pipe C
18. fore completing the connection of the water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the water supply long enough to clear the debris to waste PLUMBING CONNECTIONS Plumbing to be carried out before wiring DO NOT use jointing compounds on any pipe fittings for the installation DO NOT solder fittings near the shower unit as heat can transfer along the pipework and damage components Note An additional gate valve or fullway lever valve MUST be fitted in the water supply to the shower as an independent means of isolating the water supply should maintenance or servicing be necessary IMPORTANT The fitting on the inlet elbow is a push in type The pipework must be cut with a pipe cutter and all burrs and rough edges removed from the end of the tube The fitting can be used with copper and plastic pipe If using chrome plated copper pipe remove the first 25 mm of plating completely from the connecting surface If it is not completely removed then the collet will not grip the pipe and under pressure the pipe may be forced out Procedure Turn off water supply either at the mains stopvalve or the isolating stopvalve to the cistern Drain the cistern IMPORTANT The pipework must be brought direct from the cold water storage cistern with no other cold water draw offs between the shower and the c
19. ible hose screwed to the outlet but WITHOUT the showerhead attached Make sure the outlet of the flexible hose is directed to waste The COLD position MUST be used To check that the temperature control is correctly positioned on the stabilising valve temporarily place the cover in position so that the splines engage then rotate the temperature control fully anti clockwise Remove the cover and position the temperature control so that it points towards 1 fig 15 Position the power selector to the COLD position fig 16 DO NOT remove the locking screw fitted to the power selector spindle fig 17 it can be removed only when the commissioning procedure has been completed Make sure the water supply is still turned on to the shower Open the bleed screw on the pump unit fig 18 by rotating one revolution When water flows from the drain pipe this indicates that any trapped air is vented and that the pump unit is primed The bleed valve must now be closed by rotating in the opposite direction Offer the cover to the backplate unit Check that the power selector is still at the COLD position and the temperature control is at 1 Note Check the START STOP button is not depressed in the cover which indicates START The button should be flush with the cover otherwise water will flow as soon as the electricity is switched on 805 Attached to the 5 5 button inside the
20. ipped direct or buried non insulated Installed in an conduit insulated wall trunking wall 6 mm 6 mm 6 mm 32A 38A 46A 10 mm2 mm 10 mm2 43A 52A 63A 16 mm 16 mm 16 mm 57A 69A 85A Note Cable selection is dependent on derating factors 8 2 9 1 9 2 9 3 It is also necessary to satisfy the disconnection time and thermal constraints which means that for any given combination of current demand voltage drop and cable size there is a maximum permissible circuit length The shower circuit should be separated from other circuits by at least twice the diameter of the cable or conduit The current rating will be reduced if the cabling is bunched with others surrounded by thermal loft or wall insulation or placed in areas where the ambient temperature is above 30 C Under these conditions derating factors apply and it is necessary to select a larger cable size In the majority of installations the cable will unavoidably be placed in one or more of the above conditions This being so it is strongly recommended to use a minimum of 10mm cabling throughout the shower installation In any event it is essential that individual site conditions are assessed by a competent electrician in order to determine the correct cable size and permissible circuit length L Minimum capacity 114 litres 2
21. istern Fit the pipework to the inlet elbow Make sure the elbow collet is fully engaged with the pipe Although the pipework connection to the shower is via 15 mm diameter pipework on long runs use 22 mm diameter piping as far as possible to avoid restricting the flow to the shower Make sure that the backplate of the unit is flat on the wall and positioned squarely Tighten the fixing screws Turn on the water supply and check for leaks in the pipework connection to the shower IMPORTANT Using a suitable sealant always seal around the incoming pipework to prevent water entering the wall Note At this stage no water can flow through the unit ELECTRICAL CONNECTIONS SVVITCH OFF THE ELECTRICITY SUPPLY AT THE MAINS Fig 13 shows a schematic wiring diagram The cable entry points are shown in fig 1 The cable can be surface clipped hidden or via 20 mm conduit Note Metal conduit entry can only be from rear Route the cable into the shower unit and connect to the terminal block fig 14 as follows Earth cable to terminal marked E Neutral cable to terminal marked N Live cable to terminal marked L IMPORTANT Fully tighten the terminal block screws and check that no cable insulation is trapped under the screws Loose connections can result in cable overheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable m
22. lace the cover as described above and permanently secure with the three retaining screws DO NOT OVERTIGHTEN Switch the mains electric supply back on to the shower at the isolating switch Once the riser rail is fitted the shower is ready for normal use 8 start stop 64 temperature Fig 22 Povver on a indicator lt power temperature start stop aa Note In normal use it is in order to leave the water supply permanently on to the shower unit but as with most electrical appliances the unit must be switched off at the isolating switch when not in use OPERATING THE SHOWER WARNING Before normal operation of the shower it is essential the following commissioning procedure is completed correctly To start the shower Pressing the START STOP button fig 22 switches on the pump allowing water to immediately flow through the unit To stop the shower Press the START STOP button This switches off the pump and the water flow will cease WARNING If restarting immediately after stopping be aware that a slug of hot water will be expelled for the first few seconds To use the power selector The power selector fig 22 has four settings COLD LOW MEDIUM and FULL POWER Blue symbol is for
23. ld also cause the Pressure Relief Device in the unit to operate This product is not suitable for mounting into steam rooms or steam cubicles PLUMBING The plumbing installation must comply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS 6700 The supply pipe must be flushed to clear debris before connecting to the shower unit DO NOT solder pipes or fittings within 2 4 2 5 2 6 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 10 300 mm of the shower unit as heat can transfer along the pipework and damage components DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater can DO NOT use excessive force when making connections to the flexible hose or showerhead finger tight is sufficient All plumbing connections must be completed before making the electrical connections ELECTRICAL The installation must comply with BS 7671 Requirements for electrical installations IEE wiring regulations building regulations or any particular regulations as specified by the local Electrical Supply Company This appliance MUST be earthed In accordance with The Plugs and Sockets etc Safety Regulations 1994 this appliance is intended to be permanently connected to the fixed wiring of the electrical mains system Make sure all electrical connections are tight
24. lector Pressure switch Temperature valve Solenoid valve Earth connection Rear pipe cable entry area Inlet elbow Thermal cut out outlet Outlet pipe Filter Inside cover fig 2 20 Start Stop switch Other items Screw fixing kit Instructions guarantee etc N 245 gt J IN ELECTRICAL REQUIREMENTS 2 Before making any sort of electrical connection vvithin the installation make sure hi that no terminalis live Ifin any doubt THIS APPLIANCE MUST BE EARTHED switch off the whole installation at the mains supply and remove the correct fuse The installation supply cable and circuit PRS protection must conform with BS 7671 IEE 3 The shower must be connected to its own wiring regulations and be sufficient for the independent electrical circuit IT MUST NOT amperage required be connected toa ring main spur socket The following notes are for guidance only outlet lighting circuit or cooker circuit 1 Th
25. lls use an appropriate masonry drill but if the wall is plasterboard or a soft building block you must use suitable wall plugs and an appropriate drill bit Screw the two upper fixing screws into position T80si pumped leaving the base of the screw heads protruding 6 mm out from the wall Hook the backplate over the top screws and fit the lower fixing screw into position DO NOT fully tighten the screws at this stage as the fixing holes are elongated to allow for out of square adjustment after the plumbing connections have been completed Note A temporary factory fitted locking screw is fitted to the power selector spindle fig 12 This is to make sure the spindle is held in the COLD position while the commissioning procedure is carried out DO NOT remove the locking screw before this procedure is completed Locking VVARNINGI The outlet of the shower acts as a vent and MUST NOT be connected to anything other than the hose and showerhead supplied IMPORTANT Be
26. mperature cycling hot cool at intervals 3 1 Heater cycling on outlet thermal cut out 3 1 1 See Water too hot causes 2 1 and 2 2 and their appropriate action cures If it continues contact Triton Customer Service 4 Water too cool or cold 4 1 Too much flow 4 2 Reduction in the ambient water temperature 4 3 Electrical malfunction or safety cut out has operated 4 1 1 Reduce the flow rate via the temperature control 4 2 1 Switch to full power setting and readjust the flow rate via the temperature control to give the required temperature 4 3 1 Have shower unit checked by a competent electrician or contact Customer Service Problem Symptom 5 During use the vvater flovv ceases abruptly FAULT FINDING Cause 5 1 Interrupted power supply 5 2 Solenoid valve malfunction pump still operates 5 3 Pump motor faulty Action Cure 5 1 1 See 1 1 1 and 1 1 2 5 2 1 Switch off immediately Have solenoid checked by a competent electrician or contact Customer Service 5 3 1 See 1 5 1 6 Shower 6 1 Water starvation 6 1 1 Check the filter is not blocked First isolate performance drops to the unit the electricity supply and then remove the cover indicated by a gradual 6 1 2 Check the cold water cistern is full reduction in water 6 1 3 Make sure the water supply pipe is not flow blocked or air locked 6 1 4 Check there is no simultaneous demand from the cistern during showeri
27. ng 6 1 5 Reprime the unit without electricity switched on to the unit see commissioning section 7 Pressure relief 7 1 Blocked 7 1 1 Clean or replace blocked cartridge in the device has operated showerhead showerhead and then fit a new PRD water ejected from 7 2 Twisted blocked 7 2 1 Check for free passage through the hose PRD tube flexible shower hose 7 3 Showerhead not removed while commissioning Replace the hose if necessary and then fit a new PRD 7 3 1 Fit a new PRD Commission the unit with showerhead removed Note Identify cause of operation before fitting new PRD unit When fitting a new PRD follow the commissioning procedure It is advised all electrical maintenance repairs to the shower should be carried out by a suitably qualified person Service Policy In the event of a complaint occurring the follovving procedure should be follovved 1 Telephone Customer Service on 0870 067 3333 0845 762 6591 in Scotland and in Northern Ireland having available the model number and povver rating of the product together vvith the date of purchase 2 Triton Customer Service vvill be able to confirm whether the fault can be rectified by either the provision of a replacement part or a site visit from a qualified Triton service engineer 3 Ifa service call is required the unit must be fully installed for the call to be booked and the date confirmed In order to speed up your request please have
28. nit or a separate unit Table A RCD 22 be part of cons mer un CIRCUIT PROTECTION unit cartridge rating MCB fuse 7 0kW 30 32A 30A Fissor 7 5kW 32A 35A MCB Incoming 8 0kW 40A 35A Supply 8 5kW 40A 45A 80A or 100A main switch AN 9 0kW 40A ASA 9 5kW 40 45A 45A 10 5kW 45A ASA N S 2 6 1 6 2 8 1 A 45 amp double pole isolating switch with a minimum contact gap of 3 mm in both poles must be incorporated in the circuit It must have a mechanical indicator showing when the switch is in the OFF position and the wiring must be connected to the switch without the use of a plug or socket outlet The switch must be accessible and clearly identifiable but out of reach of a person using a fixed bath or shower except for the cord of a cord operated switch and should be placed so that it is not possible to touch the switch body while standing in a bath or shower cubicle It should be readily accessible to switch off after using the shower Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those rooms must be protected by a 30mA RCD The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B To obtain full advantage of the power provided by the shower use the shortest cable route possible from the consumer unit to the shower Table B Twin and earth PVC insulated cable Current carrying capacity Cl
29. re to follow this procedure may also cause the PRD to operate Make sure the shower is positioned over a bath or shower tray because if the PRD operates then water will eject from the bottom of the unit Should this happen turn off the electricity and water supplies to the shower at the isolating switch and stopvalve Contact Customer Service for advice on replacing the PRD WARNING The shower must not be positioned where it will be subjected to freezing conditions Cold water supply from cistern top bottom or back Ceiling Height of showerhead and shower to suit user s requirement Shower can be mounted either side of the riser rail ay A Bee de ee eee tre ee oe a Shower unit 1 pa must not P S Outline of bath di be vvithin shovver tray rj an area or cubicle H 1 metre from base KJA poi 1 Fig 6 Diagrammatic view not to scale IMPORTANT The unit must be mounted on a flat surface which covers the full width and length of the backplate It is important that the wall surface is flat otherwise difficulty may be encountered when fitting the cover and subsequent operation of the unit may be impaired TRITON 7808 FITTING THE SHOWER THE WALL WARNING Check there are no hidden cables or pipes before drilling holes for wall plugs Use great care when using power
30. the water becomes and the faster the flow the cooler the water b During the winter the cold water supply will be cooler than in the summer months Therefore the temperature of the water will vary from season to season on any one setting of the temperature control e g if you have chosen medium power for your preferred shower temperature in the summer you may have to increase that to full power during the winter months If for any reason there is a sudden rise water temperature the shower has thermal cut out devices built in see items 3 and 4 under Fault Finding If water ceases to flow switch off the shower at the start stop button and the isolating switch Contact Triton Customer Service for advice If ever the water becomes too hot and you cannot obtain cooler water first check that the sprayplate in the showerhead is not blocked DO NOT place items such as soap or shampoo bottles on top of the unit Liquid could seep through the joint between the cover and backplate and possibly damage the sealing rubber Replacement parts can be ordered from Customer Service See spare parts for details and part numbers MAIN COMPONENTS Inside unit fig 1 1 Y N A Nn ORA WON lt eo SNA MWA WNES Top cable pipe entry Motor unit Pump unit Bleed screw Wall screw fixing Feed pipe Thermal safety cut out main Terminal block Can and element assembly Power se
31. ust be secured either by routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The use of connections within the unit or other points in the shower circuit to supply power to other equipment i e extractor fans pumps etc will invalidate the guarantee WARNING Do not switch on the electricity supply until the commissioning procedure has been completed and the cover has been fitted Failure to do so could cause the pump to run dry and invalidate the guarantee Fig 13 koy outlet 1 Terminal block 7 Microswitch 9 5kW 2 Earth post 8 Neon indicator 3 Thermal cut out 9 Elements 8 5kW main 10 Element additional 4 Start Stop button for the 9 5kW 5 Pump and motor assy 11 Thermal cut out 6 Selector microswitches 12 Solenoid valve N Terminal block Fig 15 1 10 TE 6 U Locking COMMISSIONING WARNING Before normal operation of the shower it is essential the following commissioning procedure is completed correctly The first operation of the shower is intended to flush out any remaining unit debris and to make sure the heater unit contains water before the elements are switched on This operation must be carried out with the flex
32. your postcode available when booking a service call 4 Itis essential that you or an appointed representa tive who must be a person of 18 years of age or more is present during the service engineer s visit and receipt of purchase is shown 5 charge will be made in the event of an aborted service call by you but not by us or where a call under the terms of guarantee has been booked and the failure is not product related i e scaling and fur ring incorrect water pressure pressure relief device operation electrical installation faults 6 lf the product is no longer covered by the guarantee a charge will be made for the site visit and for any parts supplied 7 Service charges are based on the account being settled when work is complete the engineer will then request payment for the invoice If this is not made to the service engineer or settled within ten working days an administration charge will be added Replacement Parts Policy Availability It is the policy of Triton to maintain availability of parts for the current range of products for supply after the guarantee has expired Stocks of spare parts will be maintained for the duration of the product s manufacture and for a period of five years thereafter In the event of a spare part not being available a substitute part will be supplied Payment The following payment methods can be used to obtain spare parts 1 By post pre payment of pro forma invoice by cheque or

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  Nokia 6085 Cell Phone User Manual  NetKarma Cytoscape Visualization Plug  syringe pumps - Harvard Apparatus  Piano di Emergenza e Evacuazione    PTS 4V PTK 4  Bedienungsanleitung - CONRAD Produktinfo.  Powador Mini-Argus Mini-Argus FR  the legal mumbo jumbo we paid our lawyers for this, and to get our  