Operating instructions for the probe PH MASDVT850W6 BL3.2 X/Y
Contents
1. Fixings S Pe jscrews Fig l Position of the stop circuit coil Fig 2 probe connectors 2 Changing between 2 2 and 2 4 mode 1 Incase of operating in A 2 mode frequency range see list it is necessary to remove the short circuit screw at the 2 tube of the H channel see Fig 3 below In the other case in 4 4 mode frequency range see list use the marker at the A 2 tube and carefully turn in the screw equally and continously until one has contact with the inner conductor of the A 2 line Do not turn this screw too far in order to avoid bending or damage of the inner conductor Slide on the shielding tube and lock it 2 First tune and match H and then X and Y Repeat this procedure for fine tuning Fig 3 screw out gt A 2 mode Fig 4 screw in gt 4 mode 2 Adjustment for Optimization of the stop circuit frequency 1 Adjust the stop circuit frequency by turning the black rod at the bottom of the probe see Fig 5 and observe the insolation at the Network Analyzer see Fig 6 and Fig 7 Fig 6 C stop circuit frequency not optimized Fig 7 C stop circuit frequency optimized
2. Bruker Elektronik GmbH nfo 26 01 2010 Operating instructions for the probe PH MASDVT850W6 BL3 2 X Y H DBB H13857 0001 The probe is delivered in 4 4 mode 1 Listing of the included X Y stop circuit coil X range Y range Coil with 2 5 turns MHz MHz 2 mode 22pF serial C 190 268 117 164 131 196 A 4 mode 22pF serial C 180 217 85 143 86 151 X range Y range Coil with 4 5 turns MHz MHz A 2 mode 22pF serial C 162 265 80 129 116 179 4 mode 22pF serial C 145 214 76 121 78 140 X range Y range Coil with 6 5 turns MHz MHz 2 mode 22pF serial C 177 263 77 110 105 163 4 mode 22pF serial C 125 214 67 106 72 134 1 Changing the stop circuit coil Unscrew but don t remove 4 screws at the flange of the shielding tube and remove the tube 2 Unscrew the two M2 5 fixing screws Fig 1 below and remove the installed stop circuit coil and change it by a disered one Install the new coil in the opposite way do not tighten the screws too much 3 To adjust the optimize stop circuit frequency it is necessary to use a Network Analyzer and connect it between X and Y channel at the probe reflection gt X connector transmission gt Y connector see fig 2 below 4 Slide on the shielding tube and lock it 5 First tune and match H then X and at last Y channel Repeat this procedure for fine tuning EELIST BROKER HP WB73A MAS 3 2 BL CP TRIPLE Com
Download Pdf Manuals
Related Search
Related Contents
GAF 2251000WG Instructions / Assembly ショックリレー Lenovo ThinkCentre M82 User manual Comfort Control Panel CCPPDF file - 0,97MB 2015 210 Popular Brochure Manuali Tecnici Beretta/super exclusive micro - schede Polaroid LCD-1550 User's Manual Brother P-Touch 2400 Thermal Label Printer このたびは日立オーブンレンジをお買い上げ いただき Un pistolet de scellement se décharge et blesse un travailleur : Copyright © All rights reserved.
Failed to retrieve file