Home

Dome series detailed operating instructions

image

Contents

1. 3 001101 101100 NO 14 001110 011100 NO 15 001111 111100 NO 16 010000 000010 NO 17 010001 100010 NO 18 010010 010010 NO 19 010011 110010 NO 20 010100 001010 NO 21 010101 101010 NO 22 010110 011010 NO 23 010111 111010 NO 24 011000 000110 NO 25 011001 100110 NO 26 011010 010110 NO 27 011011 110110 NO 28 011100 001110 NO 29 011101 101110 NO 30 011110 011110 NO 31 011111 111110 NO 32 100000 000001 4 Multi cameras Selection Control The first step set the camera address According to the method described above to definite of the camera number and set the corresponding address of the camera The second step select the camera Click CAM key to enter the ball machine selection mode respectively enter the numbers 0 9 can directly select the 9 below camera do not need to press ENTER button to confirm To set up nine or more numbered camera press key you can enter values greater than 9 to delete the wrong press C key to confirm press ENTER key then this number of camera choose successfully The third step is to use other keys to control on the camera s operations IV Highlight 1 The maximum operating speed of the camera is of 63 2 A PTZ controller is defaulted can control 32 cameras and most can control up to 127 from No 33 to start somewhere need to use the software Write up to 32 preset points can be set 3 A and B can only be used to set the start and end location of the two cruise mode a
2. PT Dome Controller Dome series detailed operating instructions I Remote Controller key features additional information F1 F4 advanced user defined extensions design for specific users and machine general users will not need it Remote is a multi model fits all HOME shortcut key of preset position the user can customize a particular location DISP display software version number non customers use function key PRSET preset point setting key PATTERN set the parade path to preset point RUN Run PATTERN setted parade path and quit the cruise mode A shortcut key of preset position parade starting point B shortcut key of preset position parade ending point CAM shortcut key of camera selection mode SHOT into the preset point of call mode shortcut AUTO Automatic parade DELETE delete key of the preset point SPEED camera speed setting key ENTER confirm button and automatic cruise stop button P1 P8 shortcut of entering preset point S1 S4 shortcut of different cruise speed SETUP Baud rate and protocol settings button II Setting Methods 1 Call preset points Press the SHOT button to enter Preset point call mode respectively enter the numbers 0 9 can be directly invoked 9 below preset point do not need to press ENTER button to confirm the camera will reach preset point position If want to enter 9 or more preset point please press key To delete the wrong please press C key a
3. ee the PCBA there is a 10 bit mode DIP switch which DIP 1 6 is the camera address DIP7 8 is the baud rate DIP7hit the ON DIP8hit the OFF baud rate is 1200bps DIP7hit the OFF DIP8hit the OFF baud rate is 2400bps DIP7hit the ON DIP8hit the ON baud rate is 4800bps DIP7hit the OFF DIP8hit the ON baud rate is 9600bps DIP 9 is the camera protocol the switch hit the ON is a Pelco P hit the OFF switch is Pelco D DIP 0 is a RS485 terminal resistance hit the ON switch is to connect a 120 resistor 2 Camera Address Setting Camera addresses are set aside in the form of binary code on switch To simultaneously control more than one camera at the same time need to set up different address For example if you want to set on the 4th camera s address first decimal 4 must be converted into a binary that is 100 Then hit the DIP 3 switches ON while hit in the other switch among DIP 1 6 OFF 3 To simultaneous control several cameras the specific address settings please see the following comparison table in the following table use 1 to indicate when DIP switch position is ON and use 0 for OFF Camera number Camera address DIP switch position decimal binary camera switch position 1 6 NO 1 000001 100000 NO 2 000010 010000 NO 3 000011 110000 NO 4 000100 001000 NO 5 000101 101000 NO 6 000110 011000 NO 7 000111 111000 NO S 001000 000100 NO 9 001001 100100 NO 10 001010 010100 NO 11 001011 110100 NO 12 001100 001100 NO 1
4. nd between the A and B it can not set other preset points To set more pre set points the method please accordance with Article 4 to set up 4 Remote control of other key features please refer to the original manual V In particular settings For the PT dome which can t be opened 1 Set address of PT dome a Press the key of CAM select the address number for the PT dome b Then press the key PRESET SETUP hold on them 3 seconds for each 2 Baud rate settings a Press the SETUP key to enter the baud rate and protocol settings choose to the baud rate and protocol which you want to use b Then press the key PRESET SETUP hold on them 3 seconds for each
5. nd press ENTER key the camera will arrive the preset point location 2 Remove existing preset points Press DELETE button for 3 seconds to enter delete mode preset points respectively enter a number 0 9 can directly delete the following nine preset points do not need to press ENTER button to confirm If you want to delete more than 9 preset points please press key then you can enter values greater than 9 To delete the wrong please press C key then press ENTER key the camera will delete this preset point 3 Set up a new preset points Press PRSET button for 3 seconds to enter preset point setting mode enter the numbers 0 9 respectively can be directly preset settings the 9 below point do not need to press ENTER button to confirm To set up more than 9 preset points press key you can enter values greater than 9 To elete the wrong plese press C key then press ENTER key to confirm when the preset point was successfully set 4 Set tour path of preset points The first step set preset points Example pre set point 1 point 2 and points 3 the location of these three preset points and camera lens positions are different that is non linear three positions The second step determine the parade path Such as a parade of the three point manner is 1 2 3 2 1 that is repeated among 123 parade The third step the memory parade path Press PATTERN button 3 seconds into the parade path of preset
6. points the beginning of setting mode enter a number 1 2 3 2 1 respectively the camera will reach the preset point position that is to guide the camera to go a complete manual parade between 3 points and then press button PATTERN 3 seconds to complete the setup The fourth step press RUN button to start to run this parade pattern The camera will follow a ready pre set path to start parade and also will stay in the running the stay location is the all preset points To exit the cruise mode just press RUN button 5 To set the starting point to the end of the parade path Methods The first step set preset points Click PRSET button 3 seconds to enter preset point setting mode respectively enter the letters AB directly to set start and end point If you are running and found anti AB path then re set the AB can be exchanged AB location The second step press AUTO key to run the AB model camera repeatedly uniform parade between AB press S1 S4 can change the speed of parade To stop the parade press ENTER button 6 To set the baud rate and protocol Methos Press SETUP button 3 seconds into camera s set the baud rate and protocol mode use the up down key to select P protocol or D protocol use the left right key to change the baud rate there are 1200 bps 2400 bps 4800 bps 9600 bps optional and then press ENTER button III camera Address Setting 1 DIP Switch Description Open the camera you will s

Download Pdf Manuals

image

Related Search

Related Contents

  Castrol EDGE 5W-30  Samsung Galaxy Note 3 User Manual(Kitkat)  RBMTX-Ux1 User Manual EN  EVI-D100 Technical Manual  Franklin DBF-116 User's Manual  Instructions d`utilisation Instructions d`utilisation  LG DVX162 User's Manual  Manuel d`utilisation du site de la chorale  Medications module user manual  

Copyright © All rights reserved.
Failed to retrieve file