1. gauge panels to new J1939 compatible engines e the use of standard economical electric gauges with new J1939 engines e noneed for installation of additional gauge senders tachometer magnetic pickups and wiring CANdrive is packaged in a compact surface mounted case with epoxy encapsulation for maximum durability and environmental sealing Electrical connection is via a 12 way automotive type connector Model CDV100F has a forward facing connector and one power CAN status LED Model CDV300R has 8 LEDs for indication of J1939 transmitted engine faults and status All models include a 6 way DIP switch for flexible configuration Standard models amp accessories Stock code Description 79 70 0104 CDV100F CANdrive J1939 to gauge interface 1 x CAN status LED connector forward 79 70 0105 CDV300R CANdrive J1939 to gauge interface 8 x status fault LEDs connector rearward 78 00 0437 CDV PW 30 8 way wiring harness length 30 in 760mm Patent applied for GB2424280 Specifications Power supply Operating voltage 12V range switch S5 on up 7 to 16 VDC 24V range switch S5 off down 19 to 30 VDC Current consumption CDV100 25 mA typ CDV300 50 mA typ 2 LEDs lit Inputs CANbus SAE J1939 protocol Input has a 120 Ohm terminating resistor removable by switch S4 Outputs all ratings non reactive Oil pressure gauge engine temperature gauge switch selectable for Murphy VDO or Datcon gauges see Gauge Co
2. 00 02 0618 revision H 2015 07 13 section 80 CANdrive CANbus SAE J1939 to Electric Gauge Interface C Installation and Operating Instructions MURPHY gt Please read the following information before installing A visual inspection of this product for damage during shipping is recommended before installation It is your responsibility to ensure that qualified mechanical and electrical technicians install this product If in doubt please contact your local Murphy or Enovation Controls representative General Information MWO LD 22 E 47 WARNING DD aw 2 4 BEFORE BEGINNING INSTALLATION OF THIS PRODUCT Y Disconnect all electrical power to the machine Y Make sure the machine cannot operate during installation Y Follow all safety warnings of the machine manufacturer Y Read and follow all installation instructions As part of the MurphyLink family CANdrive offers a cost effective instrument solution for modern electronic engines CANdrive modules read engine ECU CANbus J1939 data drive standard electric panel gauges and provide LED indication of status and faults CANdrive has three dedicated outputs for tachometer oil pressure and coolant temperature gauges with DIP switch selectable compatibility for Murphy VDO or Datcon gauges For volume orders the outputs can be custom configured for other gauge types lamps relays or remote signalling CANdrive advantages include e the retrofitting of existing electric
3. 00 blue _ temperature AT H A tachometer Notes 1 CANbus J1939 networks typically have two 120 Ohm terminating resistors one at each end with a shield screen connected to ground earth at one end only Check engine amp ECU documentation for details CANdrive installation and operation 00 02 0618 revisionH 2015 07 13 p3 4 Operation and Maintenance Operation Gauge driver outputs The gauge outputs operate when CANdrive reads valid J1939 data for engine speed oil pressure and coolant temperature lf CANdrive stops receiving valid data the gauge outputs are maintained at the last known value for approximately 5 seconds after which time the outputs turn off Indicating LEDs All standard models have a green CAN LED A flashing CAN LED indicates that CANdrive is powered but is not receiving any J1939 data A constantly lit CAN LED indicates power on with good CANbus connection and J1939 activity Note J1939 activity can originate from ANY device on the CANbus network and may not necessarily be valid data from the engine ECU Model CDV300R has additional LEDs for indication of J1939 transmitted engine faults CANdrive responds to single DM1 active fault code messages that contain SPN Suspect Parameter Number FMI Fault Mode Indicator and warning stop lamp data CANdrive also reads multi packet transport messages broadcast using the BAM protocol Typically LEDs light continuously to indicate a shutdown fault
4. 100F CDV300R Rear view System connection front view front view CANdrive Standard Electric Gages Oy Tachometer i CEs INAENDA ESDI ch seh A F A CANdrive CANdrive Rear connector on CDV300R only Panel Installation CANdrive modules are surface mounted with 4 x no 4 screws fixing centre dimensions as Dimensions shown Select screw length according to panel thickness ensuring a maximum of 13mm mm in 12inch screw depth into the CANdrive fixing holes 68 2 7 panel cutout CDV300R Model CDV100F with forward facing connector is designed for surface mounting inside an enclosed panel Model CDV300F with 8 LED indicators and rearward facing connector 56 is designed for front of panel mounting this module requires an additional 60 x 40mm 96 2 20 2 4 x 1 6 in panel cut out for rear access to connector and switches A CDV300F with 1 0 60 optional gasket CDVG fitted into a well behind the case rim provides IP65 front of panel 2 4 environmental sealing Before installing ensure that the final mounting location meets operating temperature and 4 x fixing environmental sealing requirements and allows access for 20 holes 2 3 0 12 l 0 8 Max screw a connection of the wiring harness 18 depth 13 0 5 b configuration of DIP switches S1 to S5 location as shown above right Alternatively 56 set these switches before panel fixing see Configuration section below for full detai
5. 15 07 13 p4 4
6. L SALES FWMURPHY COMI EMAIL INFO ECONTROLS COM MURPHY CONTROL SYSTEMS amp SERVICES Maintenance and Warranty CANdrive has no user serviceable parts Maintenance is therefore limited to the following preventative checks Check that electrical connections are secure e Check that the CANdrive is securely mounted and kept free from ingress of water or build up of excessive dust dirt The front label and casing may be wiped with a clean damp cloth Do not use cleaning solvents CANdrive is supplied with a 2 year warranty on parts and workmanship In the event of a fault or technical query please contact your Murphy representative for technical support Further information Document 00 02 0251 EG S 21 series electric gage installation 00 02 0258 AT series tachometer installation Description SALES amp SUPPORT INTERNATIONAL EUROPE MIDDLE EAST amp AFRICA PHONE 44 1722 410055 FAX 44 1722 410088 EMAIL SALES ENOVATIONCONTROLS EU WWW FWMURPHY EU FM 28221 Tulsa OK USA CHINA FM 28221 Rosenberg TX USA PHONE 86 571 8788 6060 FM 620667 San Antonio TX USA FAX 86 571 8684 8878 FM 29422 UK EMAIL APSALES FVWVMURPHY COM LATIN AMERICA amp CARIBBEAN PHONE 1 918 317 2500 EMAIL LASALES FVWVMURPHY COM SOUTH KOREA PHONE 62 70 7951 4100 EMAIL SKOREASALES FVWVWMURPHY COM FM 523851 TS 589322 China INDIA PHONE 91 91581 37633 EMAIL INDIASALES FVWVWMURPHY COM 00 02 0618 revisionH 20
7. and flash to indicate a non shutdown warning fault LED Mode Fault J1939 SPN FMI Orel 100 1 ci shutdown gt 0 O ke l Overspeed shutdown 190 0 Flashing Overspeed warning gt 0 GE paniis PV l Reserved for future use AN Flashing Warning fault E Q Flashing Shutdown fault i j CANdrive can handle up to 8 simultaneous faults at one time additional fault messages are not registered When a fault becomes inactive and is no longer broadcast the appropriate LED goes out after approximately 2 seconds ENOVATION CONTROLS CORPORATE HEADQUARTERS 5311 S 122ND EAST AVENUE TULSA OK 74146 USA MURPHY PRODUCTS PHONE 918 317 4100 ENOVATION CONTROLS SAN ANTONIO OFFICE FAX 918 317 4266 5757 FARINON DRIVE SAN ANTONIO TX 78249 USA WWW FWMURPHY COM ECONTROLS PRODUCTS PHONE 210 495 9772 FAX 210 495 9791 ENOVATION CONTROLS HOUSTON OFFICE 105 RANDON DYER RD ROSENBERG TX 77471 USA ENOVATION CONTROLS LTD UNITED KINGDOM CHURCH ROAD LAVERSTOCK SALISBURY SP1 1QZ UK MURPHY ECONTROLS TECHNOLOGIES CHINA ohh kl EENT ROLA EUM 77 23RD STREET HANGZHOU ECONOMIC amp TECHNOLOGICAL DEVELOPMENT AREA HANGZHOU ZHEIJIANG 310018 CHINA PHONE 281 633 4500 FAX 281 633 4588 EMAIL CSS SOLUTIONS FWMURPHY COMI MURPHY INDUSTRIAL PANEL DIVISION PHONE 918 317 4100 FAX 918 317 4124 EMAIL IPDSALES FWMURPHY COMI CANdrive installation and operation SALES amp SUPPORT NORTH AMERICA EMAI
8. are wave output OV to battery positive DC with a frequency proportional to engine speed At 1500 RPM engine speed the output frequency is 119 Hz 41 suitable for driving charge alternator he ils based tachometers such as the Murphy ATA and ATHA series Pin 7 gives no output when engine speed is An 8 way 30 270mm wiring harness is available as below 100 RPM an additional loose item or as part of a CANdrive kit For customer made harnesses part numbers for the onee A o t acne mating connector plug and pins are as follows P E A E ne A a E negative terminals to battery negative ideally via Murphy Molex dedicated wiring to terminal 3 The use of dedicated part ref part ref return wiring to pin 3 rather than a ground earth return Connector plug shell x 1 79 70 1001 03 09 1125 minimises gauge inaccuracies caused by ground noise 1 required per unit or 03 09 1126 CAN Hi Connect each output to the appropriate gauge Connector pins pack of 50 o max 8 required per unit l Connect these terminals to the engine CANbus taking Terminal functions care to observe the correct polarity The CANbus cable Pin Function shield screen is typically connected to ground earth at one end only often at the ECU refer to the engine 1 Negative DC power supply manufacturer s installation guidelines 2 Positive DC power supply a 3 Negative DC gauge common return CANbus J1939 specifications require two 120 Ohm terminating re
9. ls 2 20 Configuration DIP switches S1 to S5 allow OEM or user configuration of Switch A on up CANdrive operating options Switch S6 is not used CANdrive position Y of down is supplied with all switches in the ON up position Switch settings must be made as appropriate according to Murphy EG S temp and pressure gauges the configuration table right Adjustment of the switch Datcon temp and 0 7 bar pressure gauges positions must be made while CANdrive is powered down Datcon temp and 0 10 bar pressure gauges VDO temp and 0 10 bar pressure gauges 0 10 20 bar o o7 14 21 28 34 41 48 55 62 69 76 83 90 97 2 171 143 123 103 88 74 60 47 33 240 195 160 140 115 100 82 68 55 43 35 VDO0 10bar_ 15 30 45 60 70 81 92 103 114 125 136 148 160 170 182 Temperature gauge compatibility table temperature versus approximate equivalent sender resistance Ohms Tem 90 100 110 120 130 140 Cc O a gt lt m Cp D N B O DS o1 CANdrive installation and operation 00 02 0618 revisionH 2015 07 13 p2 4 Electrical Connection CANdrive electrical connection is via a 12 Pin Function way automotive type receptacle shown right CANadrive models are available with the connector facing forward through the front label F option e g model CDV100F or Pin 7 gives a Squ
10. mpatibility section for pressure temperature verses equivalent sender resistance tables Tachometer pulsed DC 119 Hz 1 1500 RPM Physical Electromagnetic compatibility 2004 108 EC Case material polycarbonate polyester epoxy encapsulation Overall dimensions w x h x d 68 x 92 x 22mm 2 7 x 3 7 x 0 9 in allow 50mm 2 0 in depth with connector Weight approx 80g 0 2 Ib Temperature operation 40 to 85 C 40 to 185 F 70 RH storage 55 to 105 C 67 to 221 F Environmental sealing IP60 CDV300R IP65 from front with optional CDVG gasket Vibration 15g 10 to 2000 Hz 3 axis Shock 50g 11 mS 3 axis Stock code Description 79 70 1003 CDVG optional sealing gasket for CDV300R 78 70 0363 CDV100F plus CDV PW 30 harness 78 70 0364 CDV300R CDV PW 30 and CDVG gasket 79 70 1001 CANdrive connector plug shell 79 70 1002 Connector pins for above pack of 50 In order to consistently bring you the highest quality full featured products we reserve the right to change our specifications and designs at any time MURPHY products and the Murphy logo are registered and or common law trademarks of Enovation Controls LLC This document including textual matter and illustrations is copyright protected by Enovation Controls Ltd with all rights reserved 2015 Enovation Controls Ltd A copy of the product warranty may be viewed or printed by going to htto Avww fwmurphy com warranty General Information cont CDV
11. sistors at each end of the network CANdrive is supplied for use with 12V 7 to 16V DC CANdrive is supplied with a 120 Ohm network operation If 24V 19 to 30V DC operation is required terminating resistor in circuit If CANdrive is not push DIP switch S5 to the off down position positioned at the end of the CANbus network switch Connect a 1 Amp anti surge fuse in the positive DC line out the terminating resistor by pushing DIP switch 54 pin 2 off down see Configuration section for details Pins 1 and 3 are internally linked pin 1 is typically used 9 Reserved for future use as a power supply connection pin 3 is typically used as 10 Factory use a common negative return for the gauge outputs 11 Factory use 4 Oil pressure gauge output 12 Factory use 6 Coolant temperature gauge output These connections are reserved for future use or are 7 Tachometer output used in the factory setup of CANdrive Do not connect wiring or equipment to these terminals connection may Pins 4 and 6 give a variable current output for driving resul in penmanent damage ioc ANdrive oil pressure and coolant temperature electric gauges The current output versus pressure temperature is specific to each gauge type as selected using DIP switches S1 S2 and S3 see Configuration section Typical Connection Shown with Murphy EG S series gauges Swichgages and AT H A tachometer G S 21P oil pressure CAN CANdrive EG S 21T Ig coolan 12