Home
INSTALLATION AND OPERATING INSTRUCTIONS
Contents
1. CONTROL For all models except HSX6N Most of the stored heat is radiated from the grille during the discharge period Additional heat or boost is regulated by the Output Control With this set to 6 the boost begins in the early afternoon Turning the control towards 1 will progressively delay the commencement of the boost At 3 the boost will start in the evening Once set the boost will repeat itself automatically day after day If no boost is required e g when the room will be unoccupied for a long period set the Output Control to 1 With the control in this position the heater will take less energy during the next charging up period CLEANING To maintain the appearance of the heater wipe occasionally with a dry cloth when the heater is cool Do not use abrasive powders of furniture polish Discolouration of wall finishes can sometimes occur immedi ately above a storage heater due to the properaties of some paints and decorating materials or the presence of environ mental impurities in the air Such as soot or incense gener ated from the burning of candles etc AFTER SALES SERVICE Your Storage Heater is guaranteed for two years from date of purchase We undertake to exchange or repair within the period any part found to be defective due to a manufacturing fault This guarantee does not affect you statutory rights Should you require after sales service please contact the supplier through whom you purchased the heater
2. WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD IF DURING ANY REASSEMBLY OF THE HEATER A PART OF THE THERMAL INSULATION SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY IT SHOULD BE REPLACED BY AN IDENTICAL PART INSTALLATION INSTRUCTIONS 3 HSXDA MODELS ONLY The Room Sensor is located atthe rear of the right hand side of the heater Carefully slide the sensor plate down from its transit position to its The heater will arrive separately from its Model 6N 4 bricks Model 12N 8 bricks storage bricks the following bricks will ode 18N 12 bricks be required Model 24N 16 bricks Sri NT r m E a DAGIEN _ 4 ra F PEF a i WARNING This appliance must be earthed Only heat resisting cable min rating T85 should be used The wires in the mains cable will be coloured as follows GREEN amp YELLOW EARTH BLUE NEUTRAL BROWN LIVE SUGGESTED FIXINGS SOLID BRICK BLOCK No 10 Rawlplug fibre inserts 5 5mm drill bit Drill hole 6mm deeper than rawlplug length PLASTERBOARD If possible locate studding and use No 10 woodscrews directly into the wood otherwise M5 rawlplug intersets are suitable NOTE FOR OTHER WALL TYPES e g Timber frame and hollow concrete SEEK SPECIALIST ADVICE FIXING ASSEMBLY 1 ENSURE THAT FIXING KIT AND FEET HAVE BEEN LOCATED BEFORE DISPOSING O
3. or telephone 0117 923 5375 Please do not initially return faulty appliance or part of an appliance to us as this may result in transit damage and or a delay in providing service Let us know your difficulty quoting the model number and serial number located along the wall bracket We will then take the appropriate action SALES HEATSTORE Island Park Bristow Broadway Bristol BS11 9FB Tel 0117 923 5375 Part No 83103 Fax 0117 923 5374 Issue 9 May 2005
4. F PACKAGING 2 Fit the feet with the open end of the foot to the front of the heater Secure each foot using two taptite screws provided operational position e os oe RS Transit Position 3 Operational Position Place the heater on its feet and in the desired position against the wall Ensure the heater is based on a firm level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection Cut away any gripper rod or carpet which would prevent the heater sitting firmly on the floor 5 Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall Remove the wall bracket from the heater by removing the screw at each end Place the heater to one side and reposition the bracket against the wall using the corner marks for alignment Four fixing positions must be chosen for the 24N three for the 18N and two for the 12N and 6N Mark the positions for the fixing holes two at the extreme ends and the others spaced evenly between them Remove the bracket from the wall drill the holes in the positions marked and insert suitable fixings previously described Secure the wall bracket to the wall 6 If mains connection is to be made from the left side at this point the mains lead must be secured to the back of the heater using ties provided in the fixing kit 7 THE FOLLOWING MUST BE APPLIED WHEN FIXING T
5. HE HEATER TO THE WALL BRACKET i If no skirting board is present secure the heater through the wall bracket slots closest to the wall ii If 100mm 4in skirting is present secure the heater through the outer slots lil If skirting taller than 150mm 6in is present this must be reduced to 150mm 6in over the entire width of the heater plus 25mm 1in at each end Do not fully tighten these screws until the bricks are loaded into the heater as some settling of the heater may occur NOTE NEVER REMOVE THESE SCREWS WITHOUT FIRST UNLOADING THE HEATER 8 Remove the front panel by removing the two self tapping screws along its bottom edge With hands positioned on each side of the panel lift upwards to unhook the top edge whilst pressing down on the top panel with your thumbs The panel can now be lifted clear and set to one side Remove the inner front by removing the screws along its top and sides As the front insulation is attached care must be taken when lifting this panel from the heater and placing it to one side Remove the internal packing by sliding it up and off the elements taking care not to damage the insulation 1 0 Remove one element to allow access for the back rows of bricks On the 24N remove the element to the right of centre on the 18N remove the central element on the 12N the left hand element should be removed and on the 6N there is only one element Loosen the two screws se
6. HSXDA N automaticASX N manua STORAGE HEATER RANGE MODELS HSX6N 6kWh HSX DA12N 12kWh HSX DA18N 18kWh HSX DA24N 24kWh INSTALLATION ano OPERATING INSTRUCTIONS IMPORTANT PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE NOTE ALSO THE INFORMATION GIVEN ON THE HEATER The installation must be carried out by a competent electrician and should be in accordance with E E Regulations A Double Pole Switch with a contact separation of at least 3mm on each pole must be provided in the installation The heater is not suitable for connection to a 30A ring circuit Do not position the heater under windows where curtains can contact the heater casing WARNING THE SURFACES ON THIS HEATER CAN BE HOT This heater meets EN60 335 safety requirements However any heater type becomes hot in normal operation Care must be taken to ensure that prolonged skin contact with the heater does not occur WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE IMPORTANT Due to the newness of materials the heater will produce a slight smell for the first few days of operation ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN CAGED BIRDS OR PERSONS
7. curing the element tails in the ceramic connector block and lift the element up and out of the heater Carefully fit the bottom row of the back layer of bricks placing the two end bricks in position first with the narrow end of the recess over the slot in the base insulation Fit the top row of bricks with the narrow end of the recess to the top 12 Refit the element which has been removed by feeding the tails down through the hole in the base insulation and into the connector block Ensure the element is fully pushed home then securely tighten the two screws in the block Fit the front layer of bricks again with the recess towards the element The complete core will comprise 6N 1 x 4 Brick Columns 12N 2 x 4 Brick Columns 18N 3 x 4 Brick Columns 24N 4 x 4 Brick Columns 13 Replace the inner front complete with insulation by locating its bottom edge behind the front lip of the chassis and inserting retaining screws along the top and both sides 15 For models 12N 18N and 24N only check that the flap mechanism operates freely on its hinges and that with the output control set to 1 the flap is correctly seated in its closed position _ Feed the mains cable through the cable clamp and make connections as marked on heater Pull back any slack through the clamp and tighten clamping screw WARNING This appliance must be earthed 1 7 Replace outer front panel and grille by hooking the grille into it
8. er of the heater To adjust the controls on the heater use a coin and engage it in the slots provided on the top surface of the knob There are no user adjustable controls on the HSX6N CONTROL FUNCTIONS THE INPUT CONTROL For models HSXDA12N 18N 24N only This heater is fitted with a user adjustable automatic input control which varies the charge taken in response to weather conditions taking into account the amount of energy already stored in the heater Set at 6 the heater takes maximum charge and at 1 the heater takes a minimum charge at any room temperature The casing of the heater particularly in late evening may feel cool this is quite normal The input control may require a few days experimentation before your comfort level is established Initially set the control to 4 the following evening if the room is too warm reduce to 3 or if it is too cool increase to 5 On subsequent evenings adjust by half divisions until our comfort level is achieved Having established the setting the input will automatically carry the amount of heat stored to compensate for weather variations OPERATING INSTRUCTIONS For models HSX12N 18N 24N only Initially set the input to 4 If the heater does not maintain a satisfactory room temperature the following day this setting should be increased Conversely if the room temperature is too high this setting should be reduced The input control should only require seasonal adjustments THE OUTPUT
9. s retaining slot on the top panel and lowering it into position Secure the front panel with the two self tapping screws CLINT MMTMMT MTT ET TN TWO FIXING Sae SCREWS 18 Check that the screws securing the heater to the wall bracket have been fully tightened IT IS ESSENTIAL THAT ALL SCREWS ARE REPLACED TO ENSURE EARTH CONTINUITY Once installed do not attempt to reposition the heater without first obtaining the services of a competent electrician OPERATION This storage heater takes in Energy when electricity tariffs are low and dissipates it when tariffs are normal SAFETY INSTRUCTIONS 1 Ventilate rooms well during commissioning 2 Do not move the heater in any way once installed without the services of a competent electrician 3 Do not cover the heater with clothing etc at any time or position furniture close to or against the heater 4 Ensure a clearance of at least 150mm between heaters and curtains 5 Floor standing heaters must only be fitted with the back against a wall 6 Should your heater fail to operate either employ the services of a competent electrician or Telephone 0117 923 5375 ALSO REFER TO COVER PAGE COMMISSIONING Set both the Input Control and the Output Control to 6 and leave the heater for 48 hours Following the commissioning period adjust the controls as stated below SETTING THE CONTROLS The controls are located under the hinged flap at the top right hand corn
Download Pdf Manuals
Related Search
Related Contents
User Manual for the jailbreak tool upgrader. User`s Guide - TeleVantage Harbor Freight Tools 6 Amp 3 in. x 21 in. Professional Belt Sander Product manual Kingston Technology ValueRAM 64GB DDR3-1333 取扱説明書 Manual Técnico KAY Annexe J 1976 - Asave Challenge GT Tourisme Pressione o botão PROPRIO FOOT Copyright © All rights reserved.
Failed to retrieve file