Home
CL4000 Programming & Operating Instructions
Contents
1. OPERATING INSTRUCTIONS The CL4000 locks have an 11 button keypad including the Badge Bar which acts as the button UNLOCK TIME The factory pre set UNLOCK time is 4 seconds This may be changed see Program 06 PENALTY TIME Entering 3 incorrect User codes will cause the lock to suspend activity for a penalty time of 10 seconds KEY OVER RIDE The Key in Lever allows the lock to be opened for Security and Housekeeping Functions Turn the key clockwise 90 and operate the lever handle to open the door CODE FREE MODE Using the Master or the Sub Master Code programs 08 and 09 will put the lock into and out of Code Free Mode In Code Free Mode battery power is not being used If the Master and Sub Master Codes cannot be issued for this purpose it is possible to use the Key in Lever to put the lock into Code Free Mode This requires that the cylinder tailpiece be changed according to the instruction SEE LATER REVERTING TO FACTORY SETTING If the Master Code is not known the lock memory can be cleared and made to revert to the factory Master Code as follows 1 Remove one battery 2 Press and hold the O button replace the battery the Blue LED will flash twice beep will sound twice then release the O button 3 Within 3 seconds press the 0 button 3 times The Blue LED will light continuously for 7 seconds and then 2 beeps will sound The lock will have reverted to the factory set Master Code 1234 and al
2. Key Sequence Master Code 04 ee Result All User Codes suspended ee when all users enter code RESTORE ALL USER CODES Program 05 Key Sequence Master Code 05 ee RESULT All User Code restored e when all users enter code CHANGE UNLOCK TIME Program 06 Key Sequence Master Code 06 enter open time range 2 9 secs RESULT After code entry the lock will unlock for the set time Factory pre set time is 4 seconds ONE TIME USER CODES Program 07 Key Sequence Master Code 07 One time code ID eg 81 One time Code eg 4321 ee RESULT Code 4321 in position 81 will work once and then be removed from memory Note ID Positions 81 to 90 are reserved for this program functions allowing up to 10 One Time User Codes to be entered SET CODE FREE MODE Program 08 Key Sequence Master Code 08 RESULT Lock will be continuously unlocked CANCEL CODE FREE MODE Program 09 Key Sequence Master Code 09 ee RESULT Lock will revert to normal operation CHANGE MASTER CODE Program 10 Key Sequence Master Code 10 enter length of Master Code Followed by new Master Code eg 6 123456 Confirm length of Master Code followed by new Master Code eg 6 123456 ee RESULT Master Code now changed to 123456 Note If the length of the Master Code is changed then all previous User Codes will be deleted CANCEL EMERGENCY OPEN MODE Program 11 Key Sequence Master Code e 11 ee R
3. one notch at a time and try the key again If the key inserts and turns OK but 1s difficult to remove then the cap may be too loose Tighten the cap one notch at a time Adjust the cap until the key inserts turns and removes easily Caution Do not insert the key in the cylinder once you have removed the screw cap PROGRAMMING First change the factory Master Code 1234 see program 10 If the Master or Sub Master Code is entered 3 times consecutively without performing a programming function a penalty time of 10 seconds is activated Note The Badge Bar at the bottom of the keypad acts as the button The Master Code and Sub Master Code MUST always start with Codes can only be the same length as the Master Code A or in the Key Sequence below indicates LED illumination If entered a Sub Master Code can be used instead of the Master Code for all programs except program 10 and 12 ENTER NEW USER CODE Program 01 Key Sequence Master Code 01 e User Code ID eg 05 New Code eg 4321 ee Result New Code 4321 entered at User Code ID 05 e when user enters code SUPEND USER CODE Program 02 Key Sequence Master Code 02 User Code ID EG 05 e Result User Code at ID 05 suspended ee when user 05 enters code RESTORE USER CODE Program 03 Key Sequence Master Code 03 e User Code ID eg 05 ee Result User Code at ID 05 restored e when user 05 enters code SUSPEND ALL USER CODES Program 04
4. CL4000 Programming amp Operating Instructions CODES e The factory set Master Code is 1234 This should be changed immediately after installation see program 10 e The Master Code and optional Sub Master Code always start with the prefix This puts the lock into Programming Mode e When the Master or Sub Master Code is entered 3 times consecutively without performing a programming function a penalty time of 10 seconds is activated This feature is to discourage the casual use of Master Codes as User Codes e The length of the Master Code determines the length of the User Code and the Sub Master Code e Ifthe Master Codes is changed to another of the same length then the Sub Master and all User Codes will be retained e If the Master Code is change to one of a different length then the Sub Master and User Codes will be deleted e Codes may be 4 5 or 6 digits long e The lock memory will store 80 different User Codes each identified by a User Code ID 01 to 80 e The lock memory can store 10 different One Time User Codes Each One Time User Code is identified by a One Time User Code ID 81 to 90 e When in Programming Mode a Program Code must be entered within 5 seconds otherwise the Red light will flash and beep and the lock will revert to normal e Ifa programming mistake is made wait 5 seconds the Red light will flash and beep and the lock will revert to normal e Anew code will be rejected if it is already in the memory
5. ESULT The emergency unlocked condition via REN 2 will be cancelled and the lock will revert to normal operation i ru E Lode atonpis Code rejactod lt i Be Cams valid bul suapendad 4 i DELETE ALL USER CODES Program 12 Key Sequence Master Code 12 12 7 secs RESULT All User Codes will be cleared from the memory ADD CHANGE SUB MASTER CODE Program 13 Key Sequence Master Code 13 e Sub Master Code eg 2468 ee RESULT A Sub Master Code 2468 has been entered DELETE SUB MASTER CODE Program 14 Key Sequence Master Code 14 e 14 ee RESULT Sub Master Code has been deleted LOCKED UNLOCKED STATUS Program 15 Key Sequence 1 Master Code 15 1 e Locked No LED flashing this is the default setting 2 Master Code 15 2 ee Locked Red LED flashing 3 Master Code 15 3 ee Unlocked Blue LED flashing RESULT If activated LED s will flash continuously every 5 seconds Note LED s will not indicate unlocked mode by key
6. l other settings will be erased REMOTE RELEASE OPTION The lock has 2 sets of terminals for remote release labelled REM 1 and REM 2 on the printed circuit board in the front housing Cables are provided with the lock for these connections 1 Battery 2 Remote 1 3 Remote 2 4 Clutch Actuator REM 1 is intended for use when there is a need to allow a visitor to open the door after having been identified by intercom or by sight from within REM 1 would be connected to a pushbutton on a reception desk or to the appropriate button on an intercom Pushing the button would cause the Blue LED to light and would release the lock for the normal set time REM 2 is intended for use when there is a need for the door to be release by an alarm system such as a fire alarm This enables emergency personnel to rapidly check that no one is trapped overlooked in classrooms wards guest rooms etc during a fire drill When activated by an alarm REM 2 will maintain the unlocked condition for 30 minutes During this time the red LED will flash once every second and beep to indicate the unlocked condition The lock will automatically revert to normal after 30 minutes If required Program 11 can be used to revert the lock to normal before the 30 minute period has finished LOCKED UNLOCKED STATUS INDICATION Using Program 15 the Blue and Red LED s can be programmed to indicate locked and unlocked status BATTERY POWER These Electronic Codelocks sho
7. uld provide well in excess of 200 000 openings from 4 x AA cells rated at 2 900 mAh LOW BATTERY When the battery power is low the Red LED will flash 5 times before the Blue LED will flash 5 times before the Blue LED flashes to signal acceptance of the code Batteries should be changed as soon as this happens REMOVAL OF FRONT LOAD CYLINDERS TO CHANGE KEY BY PASS FUNCTION TO REPIN CYLINDERS OR TO REPLACE WITH CYLINDERS BY A DIFFERENT MANUFACTURER 1 Remove handle and cylinder If intending to use a cylinder by a different manufacturer it is advisable to confirm beforehand that the new cylinder will fit the boss The CL4000 uses a 5 pin cylinder CHANGING KEY BY PASS FUNCTIONS 4 Storeroom function tailpiece allows key to turn 90 clockwise to enable handle to retract the latch this is the factory fitted function 5 Classroom function tailpiece allows key to turn 90 clockwise and be removed leaving the handle engaged in Code Free Mode Code Free Mode is cancelled by turning key 90 anti clockwise These tailpieces will fit most screw cap cylinders from other manufacturers 6 Hold down the control pin in the end of the cylinder and unscrew the cap 7 Replace the tailpiece hold down the control pin and screw the cap fully on without tightening Ensure control pin projects to lock the cap Test the key operation If the key is difficult to insert or tight when turning then the cap maybe too tight Loosen the cap
Download Pdf Manuals
Related Search
Related Contents
OWNER`S MANUAL umpcec Disque Diamant 3M™ Scotch-BritE™ tErrE DE SiEnnE Flying Mole DADM310 User's Manual 03-la gestione della sicurezza nei laboratori scientifici.… Comprehensive HDAF-VGAF video converter Manual de Instalación y Mantenimiento Untitled Libretto Uso e Manutenzione Mekfarmer 220 - v. Pflug Laser Source Control Unit Copyright © All rights reserved.
Failed to retrieve file