1. e Code s valid but suspended CANCEL EMERGENCY OPEN MODE PROGRAM 11 Master Code e 11 oe Result The emergency unlocked condition via REM 2 will be cancelled and the lock will revert to normal operation DELETE ALL USER CODES PROGRAM 12 Master Code 12 12 e 7 secs Result All User Codes will be cleared from the memory SUB MASTER CODES ADD CHANGE SUB MASTER CODE PROGRAM 13 Master Code 13 Sub Master Code eg 2468 ee Result A Sub Master Code 2468 has been entered DELETE SUB MASTER CODE PROGRAM 14 Master Code e 14 e 14 ee Result Sub Master Code has been deleted LOCKED UNLOCKED STATUS PROGRAM 15 1 Master Code 15 1 e Locked No LED flashing this is the default setting 2 Master Code 15 2 e e Locked Red LED flashing 3 Master Code 15 3 ee Unlocked Blue e LED flashing Result f activated LED s will flash continuously every 5 seconds Note LED s will not indicate unlocked mode by key CODELOCKS HEADQUARTERS Tel 44 0 1635 239645 Fax 44 0 1635 239644 sales codelocks co uk www codelocks co uk Helpline service amp spares Freephone 0800 393 405 POI CL2 4 5000 v1 0315 Americas CODELOCKS INC US Tel 1 714 979 2900 Fax 1 714 979 2902 sales codelocks us www codelocks us Helpline service amp spares Toll free 1 877 codelock Asia Pacific CODELOCKS Australia PTY LTD Tel 61 2 9882 1009 Fax 61 2 9882 6
2. 030 sales codelocks com au www codelocks com au Helpline service amp spares Toll free 1800 052 131 CODELOCKS control convenience
3. CL2000 electronic CIOOQOO electronic electronic Programming and Operating Instructions control convenience CODES THE BASICS e The factory set Master Code is 1234 This should be changed immediately after installation See program 10 The Master Code and optional Sub Master Code always start with the prefix This puts the lock into Programming Mode When the Master or Sub Master Code is entered 3 times consecutively without performing a programming function a penalty time of 10 seconds is activated This feature is to discourage the casual use of Master Codes as User Codes The length of the Master Code determines the length of the User Code and the Sub Master Code If the Master Code is changed to another of the same length then the Sub Master and all User Codes will be retained If the Master Code is changed to one of a different length then the Sub Master and all User Codes will be deleted e Codes may be 4 5 or 6 digits long e The lock memory will store 80 different User Codes each identified by a User Code ID 01 to 80 The lock memory can store 10 different One Time User Codes Each One Time User Code is identified by a One Time User Code ID 81 to 90 When in Programming Mode a Program Code must be entered within 5 seconds otherwise the Red light will flash and beep and the lock will revert to normal If a programming mistake is made wait 5 seconds th
4. e Red light will flash and beep and the lock will revert to normal A new code will be rejected if it is already in the memory OPERATING INSTRUCTIONS The CL5000 lock has a 12 button keypad including and buttons The CL2000 and CL4000 locks have an 11 button keypad including the badge bar copeLocs com which acts as the button UNLOCK TIME The factory pre set UNLOCK time is 4 seconds This may be changed see Program 06 PENALTY TIME Entering 3 incorrect codes will cause the lock to suspend activity for a penalty time of 10 seconds KEY OVERRIDE For the CL5000 and CL4000 the Key in Lever allows the lock to be opened for Security and Housekeeping Functions Turn the key clockwise 90 and depress the lever handle to open the door For the CL2000 turning the key clockwise will retract the latch allowing the door to be opened CODE FREE MODE Using the Master or the Sub Master Code programs 08 and 09 will put the lock into and out of Code Free Mode In Code Free Mode battery power is not being used For the CL4000 and CL5000 only if Master and Sub Master Codes cannot be issued for this purpose it is possible to use the Key in Lever to put the lock into Code Free Mode This requires that the cylinder tailpiece be changed according to the instruction on pages 4 and 5 REVERTING TO FACTORY SETTING lf the Master Code is not known the lock memory can be cleared and made to re
5. emoving the battery cover on the inside of the door CODELOCKS CL4000 AND CL5000 LOCKS Removal of front load cylinders to change key bypass function to repin cylinders or to replace with cylinders by a different manufacturer If intending to use a cylinder by a different manufacturer it is advisable to confirm beforehand that the new cylinder will fit the boss Note that the CL5000 uses a 6 pin screw cap cylinder The CL4000 use a 5 pin cylinder 1 2 Remove handle and cylinder cover Turn key 90 clockwise and remove cylinder from boss 3 Remove key from cylinder Hold down the control pin in the end of the cylinder and unscrew the cap Replace the tailpiece hold down the control pin and screw the cap fully on without tightening Ensure control pin projects to lock the cap 9 6 Test the key operation If the key is difficult to insert or tight when turning then the cap maybe too tight Loosen the cap one notch at a time and try the key again If the key inserts and turns OK but is difficult to remove then the cap may be too loose Tighten up the cap one notch at a time Adjust the cap until the key inserts turns and removes easily Storeroom Function tailpiece allows key to turn 90 clockwise to enable handle to retract the latch this is the factory fitted function With key turned 90 clockwise replace cylinder cylinder cover and handle Classroom Function tai
6. lpiece allows key to turn 90 clockwise and be removed leaving the handle engaged in Code Free Mode Code Free Mode is cancelled by turning key 90 anti clockwise CAUTION DO NOT INSERT THE KEY IN THE CYLINDER ONCE YOU HAVE REMOVED THE SCREW CAP THESE TAILPIECES WILL FIT MOST SCREW CAP CYLINDERS FROM OTHER MANUFACTURERS PROGRAMMING INSTRUCTIONS First change the factory Master Code 1234 see program 10 If the Master or Sub Master Code is entered 3 times consecutively without performing a programming function a penalty time of 10 seconds is activated Note On the CL2000 and CL4000 locks CODELOCKS COM aFVIMNNTom OLOJA KOLALKOJ the keypad acts as the button The Master Code and Sub Master Code MUST always start with Codes can only be the same length as the Master Code A or in the Key Sequence opposite indicates LED illumination IF ENTERED A SUB MASTER CODE CAN BE USED INSTEAD OF THE MASTER CODE FOR ALL PROGRAMS EXCEPT PROGRAMS 10 AND 12 4 Lid a ES A ENTER NEW USER CODE PROGRAM 01 Master Code 01 User Code ID eg 05 New Code eg 4321 ee Result New code 4321 entered at User Code ID 05 e when user enters code SUSPEND USER CODE PROGRAM 02 Master Code 02 User Code ID eg 05 ee Result User Code at ID 05 suspended ee when user 05 enters code RESTORE USER CODE PROGRAM 03 Master Code e 03 eUser Code ID eg 05 e o Result Use
7. r Code at ID 05 restored e when user 05 enters code SUSPEND ALL USER CODES PROGRAM 04 Master Code 04 ee Result All User Codes suspended ee when all users enter code RESTORE ALL USER CODES PROGRAM 05 Master Code 05 ee Result All User Codes restored e when all users enter code CHANGE UNLOCK TIME PROGRAM 06 Master Code 06 enter open time range 2 9 secs e e Result After code entry the lock will unlock for the set time Factory pre set time is 4 seconds ONE TIME USER CODE PROGRAM 07 Master Code 07 One time code ID eg 81 One time Code eg 4321 ee Result Code 4321 in position 81 will work once and then be removed from memory Note ID Positions 81 to 90 are reserved for this program function allowing up to 10 One Time User Codes to be entered MASTER CODES lg SET CODE FREE MODE PROGRAM 08 Master Code 08 ee Result Lock will be continuously unlocked CANCEL CODE FREE MODE PROGRAM 09 Master Code 09 ee Result Lock will revert to normal operation CHANGE MASTER CODE PROGRAM 10 Master Code 10 enter length of Master Code followed by new Master Code eg 6 123456 confirm length of Master Code followed by new Master Code eg 6 123456 ee Result Master Code now changed to 123456 Note If the length of the Master Code is changed then all previous User Codes will be deleted ae e Code accepted fr e Code rejected e
8. utes During this time the red LED will flash once every second and beep to indicate the unlocked condition The lock will automatically revert to normal after 30 minutes If required Program 11 can be used to revert the lock to normal before the 30 minute period has finished LOCKED UNLOCKED STATUS INDICATION Using Program 15 the Blue and Red LED s can be programmed to indicate locked and unlocked status BATTERY POWER The CL5000 and CL4000 Electronic Codelocks should provide in excess of 200 000 openings from the 4 x AA cells rated at 2 900 mAh The CL2000 should provide in excess of 80 000 openings from the 2 x AA cells rated at 2 900 mAh LOW BATTERY When the battery power is low the Red LED will flash 5 times before the Blue LED flashes to signal acceptance of the code Batteries should be changed as soon as this happens BATTERY FAILURE OVERRIDE The CL2000 series has been designed so that a PP3 battery can be used to open the lock should batteries fail See image below The procedure is as follows e Place the terminals of the PP3 battery against the contact points on the lock e The positive PP3 terminal to the left hand contact e The Negative PP3 terminal to the right hand contact e On secure maintained contact the lock will beep twice and the Blue light will flash twice e Maintaining contact enter the Master Code e The clutch will release allowing the lock to be opened e Fit the new batteries to the lock by r
9. vert to the factory Master Code as follows 1 Remove one battery 2 Press and hold the 0 button replace the battery the Blue LED will flash twice beep will sound twice then release the O button 3 Within 3 seconds press the button 3 times For CL2000 and CL4000 locks press the 0 button 3 times The Blue LED will light continuously for 7 seconds and then 2 beeps will sound The lock will have reverted to the factory set Master Code 1234 and all other settings will be erased REMOTE RELEASE OPTION The lock has 2 sets of terminals for remote release labelled REM 1 and REM 2 on the printed circuit board in the front housing Cables are provided with the lock for these connections REM 1 is intended for use when there is a need to allow a visitor to open the door after having been identified by intercom or by sight from within REM 1 would be connected to a pushbutton on a reception desk or to the appropriate button on an intercom Pushing the button would cause the Blue LED to light and would release the lock for the normal set time REM 2 is intended for use when there is a need for the door to be released by an alarm system such as a fire alarm This enables emergency personnel to rapidly check that no one is trapped overlooked in classrooms wards guest rooms etc during an emergency evacuation or during a fire drill When activated by an alarm REM 2 will maintain the unlocked condition for 30 min
Download Pdf Manuals