INSTALLATICN AND OPERATING INSTRUCTIONS FOR CEILING
Contents
1. INSTALLATION AND OPERATING INSTRUCTIONS FOR CEILING PIR DETECTOR MODEL PIR360WH Important Read all instructions carefully before proceeding with installation and retain for future reference This product requires connection to a 230V AC 50Hz power source This product is for internal use only During illumination the attached lighting load can become very hot allow adequate cooling time before handing This product should be installed in accordance with current IEE Regulations and any other relevant regulations If in any doubt consult a qualified electrician Do not make any modifications tg the thet unit There are no user serviceable parts ees n a i we ee po Not Suitable for use with dimmgr switches Positioning the unit When selecting the mounting position take into account the following points 1 The sensor is designed for optimum performance when mounted on the ceiling see Figure 2 Avoid pointing at or fositioning close to heat sources such as flu s or heat extraction units which may cause false triggering 3 Avoid pointing at bright light as unit will not function when Lux control is set too dark 4 Avoid mounting at strong electromagnetic disturbance 5 Avoid mounting near reflective surfaces such as pools of water white tiles or white painted surfaces Fitting the unit Before commencing any electrical ey ensure that mains iini cables are isolated by switching off and removing the relevant fuse
2. f 2 Unscrew and remove the cord anchorage plate 3 Connect the mains wires and loading wires to the terminal block and re screw the cord anchorage plate 4 Fit the back plate on the fitting surface and refit plastic cover Black Load Blue Load j Home Ceiling Blue Main Power Brown main Power AN 360 Detection Area Figure 1 Figure 2 Operation mode When the power is on the PIR detector will enter into the warn up period approximately 40 seconds followed by the auto mode the light s will flash 3 times to indicate auto mode During auto mode the walk test should carried out Walk testing Before commencing the walk test the Lux dial should be set to the day position and time dial to the minimum position The PIR will be triggered by movement of the human body Walk slowly during walk testing in order to gain the desired detection area When the walk test is completed the Lux and time can be adjusted to the required levels The PIR detector will change from auto mode to manual override by switching the mains switch OFF ON twice within 3 seconds The lighting loi load will flash 3 times to indicate eye mode Once the PIR detector has been a psalied the u override may be activated by swiuchine the mains OFF ON twice within 3 seconds The lighting load will flash 3 times to indicate override mode The manual override mode will keep the lighting load on for approximately 8 hours If there is no further override o
3. perations the PIR detector will return to auto mode automatically after approximately 8 hours has elapsed The lighting load will flash 3 times to indicate the return to auto mode Mode changing Turn off the override switch for over 3 seconds and then turn on again the PIR detector will begin a new process for mode changing Adjusting the Lux control The Lux control has a build in photocell which detects daylight and darkness Rotate the Lux control to set to he desired level of daylight Allow approximately 5 seconds for the photocell to stabilise at the desired level Adjusting the time on contro The length of time that the switch remains on can be adjusted by from approximately 1045 seconds to approximately 6 1 minutes This is adjusted by rotating the time gauge Once the load has been triggered by the PIR detector any subsequent movement will start the timed period from the beginning Important Never attempt to remove the lens as this will damage the sensor and render all guarantees invalid Technical details Voltage 230 VAC 50Hz Wattage Max 1000W incandescent bulb Resister Load Detection range 360 and Max 5 meters radius see Figure 2 Duration time From 10 5 seconds to 6 1 minutes adjustable Lux control level Daylight and night ee Mounting height 3 meters Sie ee a ne Protection Class Il
Download Pdf Manuals
Related Search
Related Contents
GIBCO Human NSCs - Thermo Fisher Scientific Bentel Security Centrale Absoluta Manuale Installatore Spain FDL.cdr - Recambios, accesorios y repuestos Betriebsanleitung Kenwood KDC-MP245U CD Player User Manual H990取扱説明書 GE GXWH35F Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file