Home
UNIT OPERATING INSTRUCTIONS
Contents
1. UNIT OPERATING INSTRUCTIONS aA D lt er EE UNIT OPERATING INSTRUCTIONS Chiller Freezer and Heat Cool Systems IMPORTANT The mains cable must be isolated when plugging in to or unplugging from the unit Refrigeration Controller Operation The end user can alter the set point of the GAH Controller over a pre set range and initiate a manual defrost with the unit in normal operating mode The control parameters are pre set at the factory to suit normal operation for chill mid temp freeze or heat cool operation They can only be altered by entering the programming mode and as such should only be altered by a competent and authorised service engineer in the event of extraordinary operation requirements or conditions The controller has two temperature sensors one for the box temperature and one for the Evaporator coil temperature GD GAH One Call 01394 421140 The controller also has an internal timer that operates whilst the unit is switched on providing timing for defrosts and it has an internal memory to store all of the factory defined and user defined parameters In normal use the display will show the internal loadspace temperature There are also indicator lights to advise when the compressor is running when the fans are running and when the defrost is in operation Compressor Fans Defrost OFF ON Manual defrost decrease I
2. Start the vehicle engine and push the unit switch s to the ON position For units running on mains electric standby plug the unit into the mains supply and then push the unit switch s to the ON position To stop the unit To stop the unit from operating push the unit switch s to the OFF position For units running on mains electric standby always push the unit switch s to the OFF position before disconnecting the mains supply Note If you make deliveries continuously throughout the day leave the unit switch on Gi GAH One call 01394 421140 REFRIGERATION CONTROL OFF COMPARTMENT No 2 F m a e des lo g t j Flo DOS CDEL O ON GAH REFRIGERATION Lra Eol Syeten To change the thermostat settings in either compartment Press and HOLD the Info and Set button for at least Ye a second and the current temperature set point will be displayed With the Info and Set buttons still depressed raise or lower the setting by pressing the increase or decrease buttons By releasing the Info and Set button you will automatically store the setting Note The thermostat setting will only change within the limits in which the unit was designed to operate To defrost the unit Defrosting is an automatic function built into the control system The unit will defrost 30 minutes after being switched on and every hour thereafter A manual defrost can be initiated by pressing and HOLDING the Manual Defrost and Decrease button
3. for 2 seconds
4. nfo Set Point To start the unit Start the vehicle engine and push the unit switch to the ON position For units running on mains electric standby plug the unit into the mains supply and then push the unit switch to the ON position To stop the unit To stop the unit from operating push the unit switch to the OFF position For units running on mains electric standby always push the unit switch to the OFF position before disconnecting the mains supply Note If you will be making deliveries continuously throughout the day leave the unit switched on Refrigeration Control Increase Exit To change the thermostat settings Press and HOLD the Info Set Point button for at least a second and the current temperature set point will be displayed With the Info Set Point button still depressed raise or lower the setting by pressing the increase or decrease buttons By releasing the Info Set Point button you will automatically store the setting Note The thermostat setting will only change within the limits in which the unit was designed to operate To defrost the unit Defrosting is an automatic function built into the control system The unit will defrost 30 minutes after being switched on and every hour thereafter A manual defrost can be initiated by pressing and HOLDING the Manual Defrost Decrease button for 2 seconds www gah co uk GAH Dual Systems and Flexi temp OFF COMPARTMENT No ON To start the unit
Download Pdf Manuals
Related Search
Related Contents
Jøtul F 600 ,精 密 水 準 器 〝 取扱説明書 RIDGID bRaD naIleR MODel nO. R213bna RePaIR Guia para a Ligação do Q200/HE para o Eventos sunway tg te 2. Device Access USB 3.0 フラッシュメモリ MF-KCU3xxx シリーズ 取扱説明書 ご使用の Nikon Coolpix S3000 User`s Manual Manual del propietario MANUAL Y LISTA DE PARTES Copyright © All rights reserved.
Failed to retrieve file