GB Operating Instructions Hanging Balance

image

Contents

1. 1 Technical Data KERN HDB 5K5 HDB 10K10 Readout d 59 109 Weighing range Max 5 kg 10kg 2 Fundamental information general 2 1 Intended use The balance you have acquired serves to determine the weigh ing value of the material to be weighed It is intended to be used as a non automatic balance i e the material to be weighed is manually and carefully attached at the balance The weighing value can be read off after a stable weighing value has been obtained 2 2 Inappropriate use Do not use the balance for dynamic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the balance Example Slow drain ing off of liquid from a container suspended from the balance Do not attach a continuous load This can damage the measur ing unit as well as the parts relevant to safety Prevent jolts torsion and oscillation e g by appending slop ingly of all kinds Be sure to prevent overloading the balance in excess of the stated maximum load max minus any tare weight that may possibly exist This could damage the balance risk of breakage Important e Always make sure that there are no people or materi als below the load that could be injured or damaged e The balance is not suitable for weighing people Do not use as baby scales e The balance does not comply with the medic
2. al prod uct law MPG Never operate the balance in hazardous locations The series design is not explosion proof Structural alterations may not be made to the balance This can lead to incorrect weighing re sults faults concerning safety regulations as well as to destruc tion of the balance The balance may only be used in compli ance with the described guidelines Varying areas of applica tion planned use must be approved by KERN in writing 2 3 Guarantee The guarantee is not valid following e non observation of our guidelines in the operating instructions e use outside the described applications e alteration to or opening of the device e mechanical damage and damage caused by media liquids e natural wear and tear e inappropriate erection or electric installation e overloading of the measuring equipment 2 4 Monitoring the test substances The metrology features of the balance and any possible avail able adjusting weight must be checked at regular intervals within the scope of quality assurance For this purpose the answerable user must define a suitable interval as well as the Operating Instructions Hanging Balance nature and scope of this check Information is available on KERN s home page www kern sohn com with regard to the monitoring of balance test substances and the test weights required for this Test weights and balances can be adjusted quickly and at a reasonable price in KERN s accredited DKD calibratio
3. ginning Interruption Possible cause Weight display is e not illuminated The balance is not switched on e The batteries are wrongly inserted the batteries are empty e No batteries are attached The weight display e Draught air movement changes continu RR ally e Table floor vibrations e Vibrations on the balance suspension e Electromagnetic fields static charging choose different location switch off inter fering device if possible The weighing result is obviously incorrect The balance display is not set to zero Adjustment is no longer correct e Great fluctuations in temperature e Electromagnetic fields static charging choose different location switch off inter fering device if possible Switch the balance off if other error messages should appear and then switch on again Contact the manufacturer if the error message does not disappear HDB BA defsi 0610
4. ions please follow the se quence of operations below Switch on the balance and keep pressing the HOLD key until H x appears on the display The currently activated function is shown above H1 H6 and by a triangle on the display To select one of the functions please press the ON OFF TARE key The setting is stored by briefly press ing the HOLD key Hold The HOLD function allows the fixed display of weighing values for longer periods of time Depending on the operating range the ON OFF switch criteria may be selected from 4 options H1 H4 e Selecting the setting H1 freezes the weighing values for 5 seconds after the HOLD key was operated e Selecting H2 freezes the weighing values from operating the HOLD key until another key is pressed e Selecting H3 freezes the weighing values automatically for 5 seconds e Selecting H4 freezes the weighing values automatically until a key is pressed H5 Animal weighing This function is suitable for unsteady weighing procedures A mean value is derived from 16 weighing values This requires the following setting Repeatedly press ON OFF TARE until H5 appears The setting is stored by briefly pressing the HOLD key To select the animal weighing function press the HOLD key On the bottom left of the display a triangle will start flashing Weighing values are recorded as long as the triangle continues flashing 3 sec Afterwards the ave
5. its packaging remove the plastic wrapping and position the balance in its intended work ing location 5 2 1 List of items supplied Standard accessories e Hanging balance e Hand strap e Battery e Operating instructions 5 3 Battery operation and change Push off the battery cover on the back of the balance in the direction of the arrow Insert 2 batteries AAA 1 5V Replace the battery cover When the batteries are exhausted the mes sage LO appears in the balance display Press the OFF switch and replace the batteries immediately To preserve battery life the balance switches off automatically after 4 min utes if no weighing has taken place 6 6 Adjustment As the acceleration value due to gravity is not the same at every location on earth each balance must be coordinated in compliance with the underlying physical weighing principle to the existing acceleration due to gravity at its place of location only if the balance has not already been adjusted to the loca tion in the factory This adjustment process must be carried out during the initial start up after change in location and varia tion of surrounding temperature It is also recommendable to adjust the balance periodically during weighing operation in order to obtain exact measured values 6 1 Adjusting Using a precision weight the accuracy of the balance can be checked at any time and adjusted Adjustment procedure Check that the surrounding c
6. n laboratory return to national normal 3 Fundamental safety information Do not use the hanging balance to transport loads Prevent jolts torsion and oscillation e g by appending slopingly of all kinds Never use the hanging balance over the maximum permitted weight Danger of breaking Always make sure that there are no living beings or materials below the load that could be injured or dam aged gt FF FP The hanging electronic balances from the KERN HDB series are only suitable for hand held use They are not suitable for hanging from a mechanical hook e g a crane hook gu Ba 3 1 Observe the information in the operating instructions Please read the operating instructions carefully before erecting and commissioning even if you already have experience with KERN balances 3 2 Staff training The device may only be operated and looked after by trained members of staff 4 Transport and storage 4 1 Acceptance check Please check the packaging immediately upon delivery and the device during unpacking for any visible signs of external dam age 4 2 Packaging Please retain all parts of the original packaging in case it should be necessary to return items at any time Only the original packaging should be used for return consign ments Before despatch disconnect all attached cables and loose movable parts Apply any intended transport security devices Secure all parts e g glass windshield
7. onditions are stable A short warm up time of about 1 minutes are recommended for stabi lisation Press Unit key approx 3 seconds CAL and then the exact weight of the adjusting weight will appear at the display Hang on the adjusting weight on the hook of the hanging scale PF will appear a short time later and then turn off In case of an adjusting error or a wrong adjusting weight E appears in the display Recommended Adjusting weight not included HDB 5K5 HDB 10K10 5kg M1 10kg M1 7 Operation Instruction 7 1 Weighing e The balance is switched on by pressing the ON OFF TARE key e The balance display shows 0 00 e Hang on the weighing object carefully e f the weighing object is heavier than the weighing range the display indicates E Overload Be sure to prevent over loading chap 2 2 Inappropriate use e The balance is switched off by pressing the OFF key once 7 2 Taring e Switch the balance on with ON OFF TARE key and wait for 0 to appear in the display Hang on the tare load carefully and press the ON OFF TARE key again e The balance display becomes 0 00 The weight of the tare load has however been memorised internally The item to be weighed can now be placed carefully in the tare container and the weight can be read off 7 3 Data Hold The HOLD key may be used to activate various functions To select and activate these funct
8. rage weighing value of the recorded weighing values will be displayed Press HOLD the balance will automatically return to weighing mode 7 4 Weighing units switch over Using the Unit key you can switch over the display between Ib and kg The marks the active setting 8 Maintenance upkeep disposal 8 1 Cleaning Only use a cloth dampened with mild suds and not aggressive cleaning agents solvents or similar Please ensure that fluids are not able to get into the device and rub off using a clean soft cloth Loose sample residue powder can be removed carefully using a brush or hand vacuum cleaner 8 2 Maintenance upkeep The operating company shall ensure that load bearing compo nents are checked by a competent person at maximum inter vals of one year These checks can be necessary at intervals shorter than one year depending on the conditions of use This applies for ex ample in the case of particularly frequent use increased wear and corrosion The device may only be opened by trained service engineers authorised by KERN Disconnect from the mains supply before opening 8 3 Disposal The operating company shall dispose of the packaging and the device in compliance with the valid national or regional law of the operating location 9 Troubleshooting The balance should be switched off for a short time following an interruption in the programme sequence It is then neces sary to repeat the weighing process from the be
9. weighing plate power unit etc to prevent slipping and damage 5 Unpacking installation and commissioning 5 1 Place of installation place of use The balance is constructed in such a way that reliable weighing results can be achieved under normal application conditions By selecting the correct application location for your balance you will be able to work quickly and precisely Therefore please observe the following at the application location e Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight e Protect the balance against direct draughts due to open windows and doors Avoid jarring during weighing e Protect the balance against high humidity vapours and dust e Do not expose the device to extreme dampness for longer periods of time Inadmissible bedewing condensation of air moisture on the device can occur if a cold device is taken into a significantly warmer environment In this case please acclimatise the device for approx 2 hours at room temperature after it has been disconnected from the bat terys e Avoid static charging of the material to be weighed weigh ing container and windshield Major display deviations incorrect weighing results are possi ble if electromagnetic fields occur as well as due to static charging and instable power supply It is then necessary to change the location 5 2 Unpacking Carefully remove the balance from

Download Pdf Manuals

image

Related Search

Related Contents

Installation Manual - Niagara Pool & Spa  46HH - CEC  Delta Children TB84717PS  Tripp Lite SUWL2120C-5 power cable  August 2014 Brad Clayton  Samsung 2343BW Benutzerhandbuch  romÂnĂ/ moldoveneascĂ ҚАЗАҚ ENGLISH DEUTSCH РУССКИЙ 1  none 27395-WI Instructions / Assembly  ZTE V987 WCDMA/GSM Mobile Phone Quick Start Guide  