Home
        GB Operating Instructions Hanging Balance
         Contents
1. 1 Technical Data                         KERN HDB 5K5 HDB 10K10  Readout  d  59 109  Weighing range  Max  5 kg 10kg       2 Fundamental information  general     2 1 Intended use    The balance you have acquired serves to determine the weigh   ing value of the material to be weighed  It is intended to be  used as a    non automatic    balance  i e  the material to be  weighed is manually and carefully attached at the balance  The  weighing value can be read off after a stable weighing value  has been obtained     2 2 Inappropriate use    Do not use the balance for dynamic weighing  In the event that  small quantities are removed or added to the material to be  weighed  incorrect weighing results can be displayed due to the     stability compensation    in the balance   Example  Slow drain   ing off of liquid from a container suspended from the balance   Do not attach a continuous load  This can damage the measur   ing unit as well as the parts  relevant to safety   Prevent jolts  torsion and oscillation  e g  by appending slop   ingly  of all kinds  Be sure to prevent overloading the balance  in excess of the stated maximum load  max    minus any tare  weight that may possibly exist  This could damage the balance   risk of breakage    Important   e Always make sure that there are no people or materi   als below the load that could be injured or damaged   e The balance is not suitable for weighing people  Do  not use as baby scales   e The balance does not comply with the medic
2. al prod   uct law  MPG    Never operate the balance in hazardous locations  The series  design is not explosion proof  Structural alterations may not be  made to the balance  This can lead to incorrect weighing re   sults  faults concerning safety regulations as well as to destruc   tion of the balance  The balance may only be used in compli   ance with the described guidelines  Varying areas of applica   tion planned use must be approved by KERN in writing     2 3 Guarantee    The guarantee is not valid following   e  non observation of our guidelines in the operating  instructions   e use outside the described applications   e alteration to or opening of the device   e mechanical damage and damage caused by media   liquids   e natural wear and tear   e inappropriate erection or electric installation   e overloading of the measuring equipment    2 4 Monitoring the test substances    The metrology features of the balance and any possible avail   able adjusting weight must be checked at regular intervals  within the scope of quality assurance  For this purpose  the  answerable user must define a suitable interval as well as the    Operating Instructions Hanging Balance    nature and scope of this check  Information is available on  KERN s home page  www kern sohn com  with regard to the  monitoring of balance test substances and the test weights  required for this  Test weights and balances can be adjusted  quickly and at a reasonable price in KERN s accredited DKD  calibratio
3. ginning     Interruption Possible cause    Weight display is e  not illuminated     The balance is not switched on     e The batteries are wrongly inserted  the  batteries are empty    e No batteries are attached    The weight display e Draught air movement  changes continu  RR  ally e  Table floor vibrations    e Vibrations on the balance suspension    e Electromagnetic fields   static charging   choose different location switch off inter   fering device if possible     The weighing    result is obviously  incorrect       The balance display is not set to zero  Adjustment is no longer correct   e Great fluctuations in temperature     e Electromagnetic fields   static charging   choose different location switch off inter   fering device if possible     Switch the balance off if other error messages should appear  and then switch on again  Contact the manufacturer if the error  message does not disappear     HDB BA defsi 0610    
4. ions  please follow the se   quence of operations below       Switch on the balance and keep pressing the HOLD key  until  H x  appears on the display   The currently activated function is shown above    H1 H6     and by a triangle on the display       To select one of the functions  please press the  ON OFF TARE key  The setting is stored by briefly press   ing the HOLD key     Hold    The HOLD function allows the fixed display of weighing values  for longer periods of time    Depending on the operating range the ON OFF switch  criteria  may be selected from 4 options  H1 H4      e Selecting the setting    H1    freezes the weighing values for  5 seconds after the HOLD key was operated    e Selecting    H2    freezes the weighing values from operating  the HOLD key until another key is pressed    e Selecting    H3    freezes the weighing values automatically  for 5 seconds    e Selecting    H4    freezes the weighing values automatically  until a key is pressed     H5   Animal weighing   This function is suitable for unsteady weighing procedures  A  mean value is derived from 16 weighing values     This requires the following setting     Repeatedly press ON OFF TARE until    H5   appears     The setting is stored by briefly pressing the HOLD key     To select the animal weighing function  press the HOLD key   On the bottom left of the display a triangle will start flashing   Weighing values are recorded as long as the triangle continues  flashing  3 sec    Afterwards the ave
5. its packaging  remove the    plastic wrapping and position the balance in its intended work   ing location     5 2 1 List of items supplied  Standard accessories     e Hanging balance   e Hand strap   e Battery   e Operating instructions    5 3 Battery operation and change    Push off the battery cover on the back of the balance in the  direction of the arrow  Insert 2 batteries  AAA 1 5V   Replace  the battery cover  When the batteries are exhausted the mes   sage  LO  appears in the balance display  Press the OFF  switch and replace the batteries immediately  To preserve  battery life the balance switches off automatically after 4 min   utes if no weighing has taken place     6    6 Adjustment    As the acceleration value due to gravity is not the same at  every location on earth  each balance must be coordinated       in compliance with the underlying physical weighing principle    to the existing acceleration due to gravity at its place of location    only if the balance has not already been adjusted to the loca   tion in the factory   This adjustment process must be carried  out during the initial start up  after change in location and varia   tion of surrounding temperature  It is also recommendable to  adjust the balance periodically during weighing operation in  order to obtain exact measured values     6 1 Adjusting    Using a precision weight  the accuracy of the balance can be  checked at any time and adjusted    Adjustment procedure    Check that the surrounding c
6. n laboratory  return to national normal      3 Fundamental safety information  Do not use the hanging balance to transport loads     Prevent jolts  torsion and oscillation  e g  by appending  slopingly  of all kinds     Never use the hanging balance over the maximum  permitted weight    Danger of breaking        Always make sure that there are no living beings or  materials below the load that could be injured or dam   aged      gt  FF FP    The hanging electronic balances from the KERN HDB  series are only suitable for hand held use  They are not  suitable for hanging from a mechanical hook  e g  a  crane hook        gu    Ba    3 1 Observe the information in the operating instructions    Please read the operating instructions carefully before erecting  and commissioning  even if you already have experience with  KERN balances        3 2 Staff training    The device may only be operated and looked after by trained  members of staff     4 Transport and storage    4 1 Acceptance check    Please check the packaging immediately upon delivery and the  device during unpacking for any visible signs of external dam   age     4 2 Packaging    Please retain all parts of the original packaging in case it  should be necessary to return items at any time    Only the original packaging should be used for return consign   ments  Before despatch  disconnect all attached cables and  loose movable parts  Apply any intended transport security  devices  Secure all parts  e g  glass windshield  
7. onditions are stable  A short  warm up time of about 1 minutes are recommended for stabi   lisation    Press    Unit    key approx  3 seconds  CAL    and then the exact  weight of the adjusting weight will appear at the display    Hang on the adjusting weight on the hook of the hanging scale      PF    will appear a short time later  and then turn off    In case of an adjusting error or a wrong adjusting weight     E     appears in the display     Recommended Adjusting weight   not included   HDB 5K5 HDB 10K10          5kg  M1  10kg  M1              7 Operation Instruction    7 1 Weighing   e The balance is switched on by pressing the  ON OFF TARE   key    e The balance display shows  0 00       e Hang on the weighing object carefully     e  f the weighing object is heavier than the weighing range the  display indicates  E      Overload   Be sure to prevent over   loading  chap  2 2    Inappropriate use         e The balance is switched off by pressing the  OFF    key once     7 2 Taring    e Switch the balance on with  ON OFF TARE  key and wait for   0    to appear in the display  Hang on the tare load carefully  and press the  ON OFF TARE  key again     e The balance display becomes  0 00     The weight of the tare  load has however been memorised internally  The item to be  weighed can now be placed carefully in the tare container  and the weight can be read off     7 3 Data Hold    The HOLD key may be used to activate various functions   To select and activate these funct
8. rage weighing value of the  recorded weighing values will be displayed  Press HOLD  the  balance will automatically return to weighing mode     7 4 Weighing units switch over  Using the Unit key you can switch over the display between Ib  and kg  The   marks the active setting     8 Maintenance  upkeep  disposal    8 1 Cleaning    Only use a cloth dampened with mild suds and not aggressive  cleaning agents  solvents or similar   Please ensure that fluids  are not able to get into the device and rub off using a clean   soft cloth  Loose sample residue powder can be removed  carefully using a brush or hand vacuum cleaner     8 2 Maintenance  upkeep    The operating company shall ensure that load bearing compo   nents are checked by a competent person at maximum inter   vals of one year    These checks can be necessary at intervals shorter than one  year depending on the conditions of use  This applies  for ex   ample  in the case of particularly frequent use  increased wear  and corrosion     The device may only be opened by trained service engineers  authorised by KERN   Disconnect from the mains supply before opening     8 3 Disposal   The operating company shall dispose of the packaging and the  device in compliance with the valid national or regional law of  the operating location     9 Troubleshooting   The balance should be switched off for a short time following  an interruption in the programme sequence  It is then neces   sary to repeat the weighing process from the be
9. weighing plate   power unit etc   to prevent slipping and damage     5 Unpacking  installation and commissioning    5 1 Place of installation  place of use    The balance is constructed in such a way that reliable weighing  results can be achieved under normal application conditions   By selecting the correct application location for your balance   you will be able to work quickly and precisely    Therefore please observe the following at the application   location    e Avoid extreme heat as well as temperature fluctuation  caused by installing next to a radiator or in the direct  sunlight    e Protect the balance against direct draughts due to open  windows and doors    Avoid jarring during weighing    e Protect the balance against high humidity  vapours and  dust    e Do not expose the device to extreme dampness for longer  periods of time  Inadmissible bedewing  condensation of air  moisture on the device  can occur if a cold device is taken  into a significantly warmer environment  In this case   please acclimatise the device for approx  2 hours at room  temperature after it has been disconnected from the bat   terys    e Avoid static charging of the material to be weighed  weigh   ing container and windshield     Major display deviations  incorrect weighing results  are possi   ble if electromagnetic fields occur as well as due to static  charging and instable power supply  It is then necessary to  change the location     5 2 Unpacking  Carefully remove the balance from 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Installation Manual - Niagara Pool & Spa  46HH - CEC  Delta Children TB84717PS  Tripp Lite SUWL2120C-5 power cable  August 2014 Brad Clayton  Samsung 2343BW Benutzerhandbuch  romÂnĂ/ moldoveneascĂ ҚАЗАҚ ENGLISH DEUTSCH РУССКИЙ 1  none 27395-WI Instructions / Assembly  ZTE V987 WCDMA/GSM Mobile Phone Quick Start Guide    Copyright © All rights reserved. 