Rascal Plus Installation Manual
Contents
1. PA button Stopping the Bells Following an alarm enter the user code to stop the bells or sounders Entry Upon entry if all is clear the sounder will emit a steady tone In the event of there having been an alarm condition which has auto reset the sounder will pulse In the last remaining 15 seconds of the entry time the sounder will emit a rapid pipping entry hurry up tone go directly to the alarm and enter the user code 10 Resetting To reset following any alarm condition enter the user code The sounder will emit a bip bop reset required sound Press the key to reset If either the tamper or PA circuits are in fault the LED s for those zones will flash Reset the PA push or clear the tamper fault 11 Bell Test Key In Key Numbers Conditions User Code 9 All the LEDs will light There will be a 10 second pause then The internal sounder will operate for 5 seconds The external bell will operate for 5 seconds The strobe where fitted will operate for 5 seconds The control will then automatically revert back to day mode 12 Security Code Programming The control unit has a 4 digit security code that is programmable only by first entering the original code Key In Key Numbers Enter User code 91 New user code Note The factory default code is 1 2 3 4 13 Reading Logs The Rascal includes a logging mode which allows a recall of the last two set and unset events Key In Key Numbers Conditions User c
2. D 12V Positive Hold Off Bell Ring Positive Bell S 18 B Bell Ring Negative Tamper Feed 24 Tamper 2 F Tamper Return Terminations CQR Soundpac Terminations CQR Integra Name Number Name Number 1 7 Ret 24 Tamper 2 2 Tamper Return 24 Tamper ATER Bell S 18 3 ve Trigger Bell S Siren Trig Bell 20 4 12V Hold Off Bell Supply 5 12V Hold Off AIT Pity 6 LED Feed Saa Fit Link 7 No Connection Fit Enable Battery Link 8 NI CAD Charge 9 NI CAD Battery Supply i 1 10 OV Ground 24 Tamper upply SET f7 iil ve Strobe Trigger st F STR Notes 1 When connecting an SAB unit the lid tamper will cause the bell to ring from the SAB battery 2 Terminal 1 should always be used as the start of the tamper loop or the negative hold off feed for SAB unit 3 The tamper return from the Sab unit should be wired in series with all other tamper connections and connected into terminal 2 OO Had WL OD viva EL S a3dAVL TBG KO TI dOO7 43dWYL EISE DAE e e o ZLO O OOOO T 3dWyL ON w Mo 10 1N D L NOILdO Z NOILdO G Es ba CH er N Q Yd W3dWYL Xd D D D Taga AWLNS IXa z L XI sue z onp eSt STOHLNOO ONINILL Guardall Limited Lochend Industrial Estate Newbridge ag oo N CN oO a E mM Lu coo ano 5x a2 SC OO Lu Part No 320232 04
3. Fit a maximum of 2 extra 16 Ohm speakers 15 ID Switched negative voltage feed 16 L Set line for latching detector each to alarm 17 ST Strobe switched negative Fit a maximum of two low current strobes 18 S Bell signal negative 19 H Self actuating siren hold of negative This terminal goes open circuit in alarm Bell relay contacts rated at 1A max 20 Bell hold off positive supply 21 C Remote keypad clock signal 22 D Remote keypad data signal 23 AUX Auxiliary nominal 12V positive 24 AUX Auxiliary nominal 12V negative Maximum current load 150 mA OPTIONS 1 Quick Set Cut link A for quick set in part guard The exit time will be 5 seconds 2 Buzzer Volume Cut link B to reduce the buzzer low level sounder volume Sounders and Strobe Bell cut off is permanently selected The internal sounder and strobe operation are modified when the bell ring time is set to 10 mins or less Note Fit a maximum of two low current strobes Fit a maximum of two 16 Ohm extension speakers in parallel Bell Time Set 10 Mins or Less If a zone is in fault for 10 mins that zone will be isolated permanently If a zone is in alarm for shorter than the bell time the internal sounder and strobe will cut off with the bells at the end of the preset bell time If a zone is in alarm for longer than the bell time the bell will stop at the end of the bell time and the internal sounder will stop when the zone resets or at 10 mins if the zon
4. Guardall 1 2 3 c e add SSS Rascal E Rascal Installation Instructions RASCAL INSTALLATION INSTRUCTIONS Introduction The Rascal is a keypad operated microprocessor alarm control unit It has a host of enhanced features not normally found on a control panel of this size It is provided with a dedicated final Entry Exit Intermediate entry circuit and two alarm zones A common 24hr circuit and a separate Personal Attack circuit are also provided Mechanical It is housed in an attractive durable 3mm thick polycarbonate box To gain access to the printed circuit board remove the lid fixing screws Cable entry points and routing channels are provided on each side of the box Fixing A top keyhole fixing is provided Fix top securing screw hook onto the top keyhole and mark the position of the other holes Remove the unit Drill and plug the remaining fixings then secure to the wall Mains Wiring CAUTION THE ELECTRICAL INSTALLATION SHOULD COMPLY WITH THE LATEST LEE WIRING REGULATIONS IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN The supply should be taken from an unswitched fused spur outlet A three way mains terminal block is fitted below the printed circuit board Other Wiring All other wiring should use British Standard security cable to the other terminals as listed in the connection chart The routing of these cables should be kept away from sources of p
5. e remains in fault Bell Time Set 11 Mins or Longer If a zone is in alarm for less than 10 mins when the bell timer has finished the bell and the internal sounder will stop The strobe will continue until the control panel is switched off Timing Controls EXIT TIME 10 secs to 120 secs approximately ENTRY TIME 10 secs to 120 secs approximately BELL RING TIME 1 min to 40 mins approximately With all controls to increase the time turn clockwise Timing Adjustments Exit entry and bell controls are scanned at 5 min intervals When altering the times make the adjustment and enter the user code Wait 5 seconds then press the key At this point wait a further 20 seconds for the controls to be scanned The new settings will then be effective Standard SAB Universal SAB 1 Terminations Terminations Name Number Name Number 24 Tamper 1 12V Hold Off 12V Hold Off Bell 20 12V Hold Off Bell 20 12V Hold Off Bell S 18 S Bell Ring Negative Bell S 18 Bell Ring Negative 24 Tamper 2 R Tamper Return Negative 24 Tamper 2 Tamper Return Bell Ring Positive 24 Tamper 1 Tamper Feed Universal SAB 2 Flashguard Terminations Terminations Name Number Name Number 24 Tamper 1 12V Hold Off ST v E S Bell 20 12V Hold Off Bell 20 Strobe Bell S 18 Bell Ring Negative 24Tamper 1 ha A 12V Negative Hold Off 24Tamper 2 Tamper Return Negative
6. ne and the exit timer will start Zone 2 will be isolated and it s LED will pulse The IX circuit will become a second delayed entry circuit Leave the protected area by the appropriate route With home set the external bell and strobe are disabled Setting with Individual Circuits isolated Enter the user code The sounder will emit a steady tone Press the key and the number key for the zone to be isolated The LED for that zone will pulse The IX zone intermediate entry is isolated by key number 3 If more than one zone is to be isolated then each zone number must be preceeded by the key i e to isolate zones 1 and 2 enter code followed by 1 then 2 Any Exit Faults This will cause the exit timer to halt and the sounder to pulse The circuit LED will light When the fault is cleared the LED will go out and the exit timer will restart The alarm may not be set with a fault present The minimum exit time folllowing an exit fault will be 5 seconds 24hr Tamper When the panel is set a tamper alarm will activate the internal and external sounders and the strobe When the panel is not set during the day a tamper alarm will activate the internal sounder only In both cases the tamper LED on the control panel will be lit when unset Reset the panel and clear the fault Personal Attack In alarm both the internal and external sounders and strobe will operate The PA LED on the control panel will be lit Reset the alarm and reset the
7. o day mode To disable press followed by the 4 key The FX LED will go out Press the key to revert to day mode To check the Chime simply press the key If the FX LED lights the chime function is on If the LED is off then the chime function is off Always press the key to revert to day mode when finished If the key is not pressed after 15 seconds have expired the control panel will revert to day mode automatically CONTROL OUTPUTS 1 ID Output This is a supply negative OV feed for Viper detectors shatterbox and smoke detectors which require a temporary removal of power to clear their alarm memories The terminal pulses off when the alarm is turned to Ge 1 2 second pulse or at Reset 3 second pulse Current limit 50 mA 2 L Latch Line Set Unset This output is for controlling latching PIR detectors The line goes to 12V when set and returns to OV when unsetting occurs 3 12V Auxiliary This is the supply for PIR or other powered detectors The maximum permissible load is 150 mA 4 Battery Fuse The battery fuse is a20mm 1 Amp anti surge type Connections Terminal Group 1 Alarm connections No Name Description 1 amp 2 24 Tamper Common tamper loop 3 amp 4 PA Personal attack circuit 5 amp 6 1 Alarm Zone 1 7 amp 8 2 Alarm Zone 2 9 amp 10 IX Intermediate entry circuit 11 amp 12 FX Entry Exit circuit Terminal Group 2 Power and Control No Name Description 13 EXT Extension speaker connections 14 SPK
8. ode 93 A steady tone and the display indicating the last set state TO VIEW ANY DAY S LOG Key View Key View 1 Log 1 SET Log 1 UNSET 2 Log 2 SET Log 2 UNSET The log is organised as SET and UNSET events All events are recorded The first to alarm is shown by the relevant LED being lit continuously Subsequent alarms as shown by a fast pulse of the relevant LED Any zones isolated are shown by a slow pulse on the relevant LED When this option is first entered the display will be showing log 1 SET state To display the UNSET Day conditions press the key The buzzer will sound whilst viewing the GET logs Any key press error will cause a return to viewing Log 1 SET To revert back to day mode press the key 14 Walk Test Key In Key Numbers Conditions User code 94 A steady tone The zone alarm devices may now be operated The display will show the zones operated and a high level sounder will follow the status of the zone under test To revert back to day mode press the key Note PA or tamper circuits may not be walk tested An alarm condition will be generated upon operation 15 Chime Control The chime is a tone associated with the entry exit zone FX and can be used to alert the user to any intrusion during the unset times The chime can be turned on and off while the alarm is not set as follows To enable press followed by the 4 key The FX LED will light Press the key to revert back t
9. ossible interference i e fluorescent lights central heating thermostats and fuse boxes etc First Powering Up When power is first applied the alarm will come on in a tamper condition Enter the factory default code 1 2 3 4 to stop the sounder then press the to reset to normal Display Interpretation The first zone to alarm will indicate with a continually lit LED Any secondary or subsequent alarm zones will be indicated by a fast flashing LED Any isolated zones will be indicated by a slow flashing LED Operation Notes sch Hu J There are three set positions Full set arms all zones Two part sets are provided both isolate Zone 2 and make the IX circuit into a second delayed entry circuit Part set and 0 allows the external bell to ring Home set and 4 disables the external bell and strobe Full Set Enter the user code default 1 2 3 4 The sounder will emit a steady tone and the exit timer will start Leave the protected area by the appropriate route Part Set Enter the user code then press the and 0 keys The sounder will emit a steady low tone and the exit timer will start Zone 2 will be isolated and it s LED will pulse The IX circuit will become a second delayed entry circuit Leave the protected area by the appropriate route With part set the external bell will sound in the event of an alarm Home Set Enter the user code then press the and 4 keys The sounder will emit a steady low to
Download Pdf Manuals
Related Search
Related Contents
iPC-Series PCs Manuel - CaryMart Netgear ProSafe Plus JGS516PE Subaru CM631UD (Clarion PF-3391A-A) 建設部 - 秋田市 Manual de Usuario Cortadora de Carne RPJ-2 REV.1 Samsung 241MP Manuel de l'utilisateur ZXHN H168N Manual del Operador HG MIG 200/ 250/ 300/ 350/ 400 Best WPD28I User's Manual Copyright © All rights reserved.