1. The following installation parts are supplied Use them as eWith cover open required Name and Shape Q ty Application Display panel Wired remote Main unit controller su We TH FR sa RT STOP vy A ej 2 Installation manual This manual Q at DAY SS FAN 09 1 wu wom lt L TIMER DELETE TIMER SET MAINTENANCE ECONOMY 9 Ila H G2 el Operating manual Instruction book for opera KE tion 1 i e Display panel Remote controller For connecting the remote cable 10m controller 8 TTT 3 6 9 12 15 1821 1 Exclude some models ao o T ia fa Ha E 52 oe ela Screw For installing the remote M4 x 16mm controller ey gt D sETTEMP V SETTEMP A Set Temperature Binder For remote controller and Button Qu 1 remote controller cable 2 G TIMER MODE CLOCK ADJUST Timer Mode Clock Adjust binding Button UTY RNKYT does not contain cables DAY DAY OFF Day Day OFF Button 4 OG SETBACK Set Back Button lt gt Set Time Button 3 ELECTRICAL
2. power supply Remote controller cable En 5 Modify the cable as per below methods 1 Use a tool to cut off the terminal on the end of the remote controller cable and then remove the insulation from the cut end of the cable as shown in Fig 1 2 Connect the remote controller cable and connecting cable as shown in Fig 2 3 Be sure to insulate the connection between the cables Fig 1 Fig 2 Black Insulated connection Connecting A Black cable Remote controller cable Red 5 3 2 When connecting to exclusive terminal block 1 When connecting to the exclusive terminal block of TYPE A or TYPE B Fixing screw of M3 Cut the Y type terminal at the end of remote controller cable and connect it screw Ae or Terminal block able Terminal block Terminal block to outdoor unit nd Terminal block to power supply E Remote controller remote controller cable Indoor unit PCB Y type terminal may be damaged if it is inserted to the exclusive terminal block strongly X It may be failed if it is connected to the outdoor unit or the terminal block for power supply 2 When connecting to the exclusive terminal block of TYPE C Fixing screw M4 Connect the end of remote controller cable directly to the exclusive terminal block M4 screw A e TYPEC N Terminal block Terminal block ermi
3. Fixed at OFF Cannot be used Refer to 6 2 Master Slave INSTALLATION DIP METHODS switch 1 3 Fixed at OFF Cannot be used DS 1 4 x Fixed at OFF Cannot be used 5 x Fixed at OFF Cannot be used 6 Disable Enable Memory backup setting 1 Factory setting 1 Memory backup setting Set to ON to use batteries for the memory backup If batteries are not used all of the settings stored in memory will be deleted if there is a power failure 5 3 Connection of Remote Controller Cable CAUTION When connecting the remote controller cable to the indoor unit do not connect it to the outdoor unit or the power terminal block It may cause a failure There are 2 methods to connect the remote controller cable to the indoor unit One is the connection using contained connecting cable and the other is the connection the remote controller cable is connected to the exclusive terminal block of the indoor unit Exclusive terminal block for remote controller connection method is different depending on each model Modify the remote controller cable as per below description and connect it For the details refer to the installation manual of the indoor unit to be used 5 3 1 When connecting to the connector Connect the remote controller cable to the connecting cable and insert it to the connector Connecting cable Indoor unit Terminal block Connector PCB to outdoor unit
4. For details of the operation methods refer to the operating manual Request the user to keep this manual on hand for future use such as for relocating or repairing the unit This mark indicates procedures which if NWARNING improperly performed might lead to the death or serious injury of the user Perform electrical work by an authorized service personnel in accordance with the installation manual and the electrical wiring regulations or implementation regulations of the country Also do not install this unit by yourself Improper electric work will cause electric shock or a fire Perform installation work in accordance with the installation manual Request an authorized service personnel to perform installation work Do not install this unit by yourself Improper installation will cause injury electric shock fire etc In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Install a leakage circuit breaker to power supply cable in accordance with the related laws and regulations and electric company standards This mark indicates procedures which if improperly performed might possibly result in personal harm to the user or damage to property NCAUTION When detecting the room temperature using the remote controller please set up the remote controller according to the following condition
5. FUNCTION SETTING be sure to turn off the power and turn it on again 11 ADMINISTRATIVE INDOOR UNIT SETTING If Priority on Administrative Indoor Unit is selected in the setting of priority mode by PUSH SWITCH of outdoor unit refer to installation manual of outdoor unit an indoor unit selected from the same refrigerant system can be set to Administrative Indoor Unit Administrative Indoor Unit shall be set by the wired remote controller What is Administrative Indoor Unit An indoor unit which decides the priority mode cooling or heating in a same refrigerant system Administrative Indoor Unit can be set to a unit in a same refrigerant system About setting and releasing of Administrative Indoor Unit Setting and releasing of Administrative Indoor Unit another indoor unit Setor release Administrative Indoor Unit 2 Press the xow MODE button Display 1 b when setting and display 1 a when releasing gt The display blinks when the xot MODE button is pressed and the display of 1 a and 1 b alters whenever the xow MODE button is pressed The contents set in the wired remote controller are transferred to the indoor unit immediately after the display is selected It may take 10 seconds depending on communication conditions While this period the button operation will be suspended gt It returns to the normal display after 20 seconds automatically if th
6. cables Remote controller 2 Remote controller DIP Switch 1 No 2 setting Set the remote controller DIP switch 1 No 2 according to the following table Number of remote Slave unit controllers DIP switch 1 DIP switch 1 No 2 No 2 1 Single OFF _ 2 Dual OFF a Group control and dual remote control can be used together When connecting 2 remote controllers the remote controller can also be connected together with another type of remote controller 7 TURNING ON THE POWER CAUTION Recheck the wiring Incorrect wiring will cause trouble 1 Check the remote controller wiring and DIP switch settings 2 Install the front case When installing the front case connect the connector to the front case in 5 INSTALLING THE REMOTE CONTROLLER 3 Check the indoor and outdoor unit wiring and circuit board switch settings and then turn on the power of the indoor and outdoor units After D has flashed on the set temperature display for Several seconds the clock display will appear in the center of the remote controller display SU WO TU WE TH FR SA 200 For the wiring and circuit board switch settings method refer to the installation manual for the indoor unit and outdoor unit 8 SETTING THE ROOM TEMPERATURE DETECTION LOCATION N CAUTION As the temperature sensor of remote control
7. data again as per procedure 4 5 above 1 After the indoor unit stops operation press the MODE button of wired remote controller for 5 seconds continuously The operating mode of the wired remote controller display lights on after 5 seconds as follows 1 a The indication 1 b The indication not set as setas Administrative Administrative Indoor Unit Indoor Unit 3 le 5 e 5 s MODE button is locked by below reasons while the marking lights on In such case Administrative Indoor Unit cannot be set or released Operation Lock Display Priority on Administrative Indoor Unit is not selected in the setting of priority mode of outdoor unit Set Administrative Indoor Unit in the wired remote controller after selecting Priority on Administrative Indoor Unit in setting of priority mode of outdoor unit Another indoor unit was set to Administrative Indoor Unit already Release the setting Administrative Indoor Unit of 6 Repeat steps 2 to 5 to perform additional settings Press the SETTEMP V button B A button and FAN button simultaneously again for more than 5 seconds to cancel the function setting mode In addition the function setting mode will be automatically canceled after 1 minute if no operation is performed 7 After completing the
8. heating fire or electric shock Install the power supply cable and remote controller cables of the indoor or outdoor unit 1 m away from television and radio to avoid distorted images and noise Perform wiring so that water does not enter this unit along the external wiring Always install a trap to the wiring or take other countermeasures Otherwise it will cause trouble or electric shock or fire Confirm the name of each unit and name of each terminal block of the unit and connect the wiring in accordance with the directions given in the manual so that there is no incorrect wiring Incorrect wiring will damage the electric parts and cause smoke and fire When installing the connection cable near a source of electromagnetic waves use shielded cable Otherwise a breakdown or malfunction could result 5 1 Installation Open the operation panel on the front of the remote controller remove the 2 screws indicated in the following figure and then remove the front case of the remote controller When open the remote controller remove the connector from the front case The cables may break if the connector is not removed and the front case hangs down When installing the front case connect the connector to the front case When removing and connecting the connector be careful not to break the cables Front case back side Rear case Screws Connector 1 Pass the remote controller cabl
9. on the function numbers and setting numbers Prepare for setting of indoor unit referring to installation manual of indoor unit before start of functional setting 1 Press the SETTEMP V button g SET TEMP A button and 90 FAN button simultaneously for more than 5 seconds to enter the function setting mode pS SETTEMP 32 FAN 2 Press the SETBACK button to select the indoor unit number GB SET BACK SU S TU WE TH FR SA nn nn a Unit number of ees SEEN INDOOR UNIT 3 Press the lt button or gt button to select the function number ey 4 Press the SET TEMP YV button or SET TEMP A button to select the setting number The display flashes during setting number selection BEA 5 Press the TIMER SET button to confirm the setting Press the TIMER SET button for a few seconds until the setting number stops flashing If the setting number display changes or if is displayed when the flashing stops the setting number has not been Set correctly An invalid setting number may have been selected for the indoor unit Function Number EM Mn an Jjn TI Fr When Setting Number data is not set in the indoor unit dis properly is displayed Blinking changes to steady Set the Setting Number illumination When Setting Number data is set in the indoor unit
10. sulfuric gas chlorine gas acid or alkali It will cause the copper pipes and brazed joints to corrode which can cause refrigerant leakage Area containing equipment that generates electromagnetic interference It will cause the control system to malfunction preventing the unit from operating normally Area that can cause combustible gas to leak contains suspended carbon fibers or flammable dust or volatile inflammables such as paint thinner or gasoline If gas leaks and settles around the unit it can cause a fire Do not use the unit for special purposes such as storing food raising animals growing plants or preserving precision devices or art objects It can degrade the quality of the preserved or stored objects Install the unit in a well ventilated place avoiding rains and direct sunlight Dispose of the packing materials safely Tear and dispose of the plastic packing bags so that children cannot play with them There is the danger of suffocation if children play with the original plastic bags Do not insert articles into the slit parts of this unit Doing so will cause trouble heating or electric shock Do not operate this unit when your hands are wet Touching the unit with wet hands will cause an electric shock If children may approach the unit take preventive measures so that they cannot reach the unit En 2
11. REQUIREMENT 6 TIMER DELETE Timer Delete Button When connecting the remote controller use the following TIMER SET Timer Set Button START STOP Start Stop Button Use Size Wire type Remarks 8 exon MODE Mode Button Remote 0 33 mm 22AWG Use shield 9 FAN Fan Control Button controller cable Polar 3 core cable in 4 4 Horizontal airflow direction and swing Button Twisted pair accordance os with local rules 3 0 Vertical airflow direction and swing Button for cable 43 ECONOMY THERMO SENSOR Economy Thermo Sensor Button 4 SELECTING AN INSTALLATION FILTER RESET Maintenance Filter Reset amp 8 Operation Lamp Day Display s Operation Lock Display Temperature Display Unit mm Fan Speed Display Timer Mode Display Operation Mode Display Timer and Clock Display Q3 Filter Display Economy Display Thermo Sensor Display Vertical Swing Display Horizontal Swing Display Defrost Display 120 Hole x 3 En 3 5 INSTALLING THE REMOTE CONTROLLER N WARNING Always use the accessories and specified installation work parts Check the state of the installation parts Not using the specified parts will cause units to fall off water leakage electric shock fire etc Insta
12. TEMP A button Range of setting is 00 63 Indoor unit address data 8 xn Ex When Indoor unit address data 12 is selected En 7 5 Fix the Indoor unit address data by pressing the TIMER SET button Data is transferred to the indoor unit TIMER SET NO When Indoor unit address data is not set in the indoor unit address is displayed Setthe Indoor unit address data again as per procedure 3 5 above BU we FR DiDi When Indoor unit address data is set in the indoor unit properly Blinking changes to steady illumination Refrigerant circuit address setting 6 Press the SETBACK button and select the Remote controller address Select the relevant indoor unit Remote controller address B SETBACK E CUM TY WE TH FR SA Ex When Remote controller address 01 is selected 7 The Address code 02 blinks when pressing the lt button or gt button Address code ER Te pol Down button Up button 8 Set the Refrigerant circuit address data by pressing the SETTEMP V button A button Range of setting is 00 99 Refrigerant circuit address data D 00 Ex When Refrigerant circuit address data 18 is selected DW ru FR sa 8 9 Fi
13. VRF SYSTEM WIRED REMOTE CONTROLLER UTY RNK INSTALLATION MANUAL For authorized service personnel only zt 6 SETTEMP J START STOP 4 v Contents 1 SAFETY PRECAUTIONS 2 2 MAIN UNIT AND 9 3 3 ELECTRICAL 3 4 SELECTING AN INSTALLATION LOCATION 4 1 4 2 Name of parts 5 INSTALLING THE REMOTE CONTROLLER 5 1 Iristallation entren cene 4 5 2 Setting the DIP switch nre 5 5 3 Connection of Remote Controller Cable 5 6 INSTALLATION METHODS 6 1 Group COMTO ere 6 6 2 Dual remote control 6 7 TURNING ON THE 7 8 SETTING THE ROOM TEMPERATURE DETECTION LOCATION e T 9 ADDRESS SETTING 7 10 FUNCTION 5 2 8 11 ADMINISTRATIVE INDOOR UNIT SETTING 9 12 TEST RUN i ee teo o ete nd Cad 10 13 ERROR CODE DISPLAY 10 PART NO 9373328070 07 English Portugu s 1 SAFETY PRECAUTIONS The SAFETY PRECAUTION indicated in the manual contain important information pertaining to your safety Be sure to observe them
14. display it means under maintenance Indoor unit cannot be operated 13 ERROR CODE DISPLAY If an error occurs the following display will be shown Faulty unit No 0 15 CO Error code SU MO U WE 1H FR SA VIE 2 1 JIN TIN Ex Error code display Do not used the operation below if an error has occurred When 0 15 is indicated on the Faulty unit No error has occurred at the indoor unit Refer to the indoor unit installation manual Faulty unit No Indoor unit lt remote rr controller communication LL error rr 16 Incompatible indoor unit LLI is connected En 10
15. e operation button is not pressed When setting or releasing is completed the indication on wired remote controller changes to the normal indication from blinking 3 Complete the setting or releasing of Administrative Indoor Unit e Press the xov MODE button of the wired remote controller again for 5 seconds continuously The indication returns to normal display if the xov MODE button is pressed for 5 seconds continuously It returns to normal indication after 20 seconds even if the MODE button is not pressed En 9 12 TEST RUN Test run method of the indoor unit is explained Refer to the indoor unit installation manual for the list of items to check 1 If the operation lamp is on press the START STOP button to turn it off START STOP 4 e 2 Press the MODE button and 9 FAN button at the same time for more than 2 seconds to start the test run The operation lamp will light up and g will be displayed on the set temperature display FAN MODE 1 D n ti at Es Test run display 3 To stop the test run press the START STOP button SETTEMP V button SETTEMP A button do not function However the other buttons can be used to change the settings Test run is used for constrained operation of the outdoor unit Note When gg is indicated on the temperature
16. e through the hole in the rear case and connect the remote controller cable to the remote controller terminal block specified in Fig 1 2 Clamp the remote controller cable sheath with the binder as shown in Fig 1 3 Cut off the excess binder 4 Install the rear case to the wall box etc with 2 screws Fig 2 Fig 1 112V 2 Signal Red White Black _ 3 Unit mm T 1 12V Red 2 Signal White 3 COM Black Tightening torque 0 8 to 1 2N m 8 to 12 kgf cm CAUTION When connecting the remote controller cables do not over tighten the screws N CAUTION Be careful to avoid breaking the cable by over tightening the binder Fig 2 Example Remote controller cable Connector Box Rear case Screws C Earth Ground the remote controller if it has a earth ground cable Wrap the connector and remote controller cables with vinyl tape or some other type of insulation as shown in the figure Remote controller 5 2 Setting the DIP switch Set the remote controller DIP switches Fig 3 Set DIP switch 1 NO 6 to ON For the other switch set it according to the situation Fig 3 Example pum Joe ou 103 Y Front case back side I 20m sid E 48 J EAN DIP switch N DS 1 Switch state NO OFF ON Detail 1
17. ler detects the temperature near the wall when there is a certain difference between the room temperature and the wall temperature the sensor will not detect the room temperature correctly sometimes Especially when the outer side of the wall on which the sensor is positioned is exposed to the open air it is recommended to use the temperature sensor of the indoor unit to detect the room temperature when the indoor and outdoor temperature difference is significant The detection location of the room temperature can be selected from the following 2 methods Choose the detection location that is best for the installation location The temperature sensor of the indoor unit or the remote controller can be used to detect the room temperature Press the ECONOMY THERMO SENSOR button for 2 seconds or more to select the temperature sensor of the indoor unit or the remote controller Indoor unit E me 5 lt gt 24 e NoTEs The remote controller sensor cannot be used if the indoor unit has no temperature setting function When this function cannot be used the lock display will flash when the ECONOMY THERMO SENSOR button is pressed 9 ADDRESS SETTING Address setting method of indoor unit can be selected from 3 options outdoor unit indoor unit and remote controller Refer to the installation manual of outdoor unit o
18. ll at a place that can withstand the weight of the unit and install positively so that the unit will not topple or fall When installing this unit make sure that there are no children nearby Otherwise injury or electric shock could result After installing this unit perform the test run to confirm that the unit is operating properly Then explain the operation of this unit to the customer Before starting installation work turn off the power of this unit and the connection destination Do not turn on the power again until installation is completed Otherwise it will cause electric shock or fire Use the accessories or specified power supply cable and remote controller cables Do not modify power supply cable and remote controller cables other than those specified do not use extension cords and do not use independent branch wiring Overcurrent may cause electric shock or fire Install the remote controller cables securely to the terminal block Confirm that external force is not applied to the wire Use remote controller cables made of the specified wire If intermediate connection or insertion fixing are imperfect it will cause electric shock fire etc When connecting the power supply cable and transmission cable route the cables so that the rear case of this unit is securely fixed If the rear case is imperfectly fixed it may cause fire or overheating of the terminals Perform earth Ground work p
19. nal block to to outdoor unit Remote controller remote controller cable Indoor unit Power supply PCB E X It may be failed if it is connected to the outdoor unit or the terminal block for power supply En 6 6 INSTALLATION METHODS 6 1 Group control 1 Wiring method indoor unit to remote controller Indoor unit Remote controller cable When there is earth ground Remote controller cable A number of indoor units can be operated at the same time using a single remote controller Indoor unit 0 Indoor unit 1 Indoor unit 2 Indoor unit 3 z v1 v2 vs z vi vz va z vi va vs Remote controller cable Remote controller When there is a earth ground cable 2 Remote controller address setting Set each remote controller address using the switch of each indoor unit in order from 0 Refer to the installation manual for the indoor unit Up to 16 indoor units can be connected 6 2 Dual remote control 2remote controllers can be used to operate the indoor units The timer cannot be used on the slave units ADDRESS SETTING and FUNCTION SETTING cannot be used on the slave units The remote controller UTB LA and remote controller UTB U UTB P UTB R cannot be connected at the same time 1 Wiring method Indoor unit to remote controller Indoor unit Remote controller When there are earth ground d
20. ositively Do not connect the earth Ground wire to a telephone earth Ground wire water pipe or conductor rod Always fasten the outside covering of the connection cord with the cord clamp If the insulator is chafed electric discharge may occur When performing cable wiring work be sure that it does not touch the user Doing so will cause injury or electric shock If any cable is damaged do not repair or modify it yourself Improper work will cause electric shock or fire En 4 CAUTION Do not set the DIP switch or rotary switch of this unit except as specified in this manual or the operating manual supplied with the air conditioner Setting the switches other than specified will cause an accident or trouble Use an insulated screwdriver to set the DIP switches Before opening the case of this unit completely discharge static electricity charged on you body Not doing So will cause trouble Do not touch the circuit board and circuit board parts directly with your hands Otherwise injury or electric shock could result Tightening the mounting screws too tight will damage the case of this unit Be careful so that the front case does not fall after the front case screws are removed Otherwise injury could result When performing wiring work be careful not to damage the cable or injure yourself Also connect the connectors securely Loose connectors will cause trouble
21. r indoor unit when set up from the outdoor unit or the indoor unit Indoor unit address and Refrigerant circuit address can be set using the remote controller This function can be set in all indoor units when the remote controller is connected Remote controller address cannot be set in this function Ensure to set with the Rotary switch of PCB of the indoor unit When setting the address of indoor unit refer to installation manual of indoor unit When setting the address of outdoor unit automatically refer to installation manual of outdoor unit When setting the address with a remote controller refer to installation manual of indoor unit for setting details of indoor unit Switching selection of address setting mode 1 Press the SETTEMP V button SETTEMP A button and 8 FAN button for more than 5 seconds simultaneously Then shift to Address setting mode A xm Indoor unit address setting 2 Press the G 8 SETBACK button and select the Remote controller address Select the relevant indoor unit Remote controller address Address setting mode initial display SET BACK Ex When Remote controller address 01 is selected 3 The Address code 01 blinks when pressing the lt button or gt button Address code EIDER 4 Set the Indoor unit address data by pressing the SETTEMP Y button or SET
22. s If the remote controller is not well set the correct room temperature will not be detected and thus the abnormal conditions like not cool or not heat will occur even if the air conditioner is running normally A location with an average temperature for the room being air conditioned Not directly exposed to the outlet air from the air conditioner Out of direct sunlight Away from the influence of other heat sources Pay abundant care when transporting this unit because it is a precision device Improper transportation will cause trouble Do not touch the switches with sharp objects Doing so will cause injury trouble or electric shock Do not expose this unit directly to water Doing so will cause trouble electric shock or heating Do not set vessels containing a liquid on this unit Doing so will cause heating fire or electric shock Use a power source exclusively for this unit Never share the power source with other electrical equipment Doing so will cause fire and electric shock Do not install the unit in the following areas Do not install the unit near a source of heat steam or flammable gas Area filled with mineral oil or containing a large amount of splashed oil or steam such as a kitchen It will deteriorate plastic parts causing the parts to fail or the unit to leak water Area that generates substances that adversely affect the equipment such as
23. x the Refrigerant circuit address data by pressing the TIMER SET button Data is transferred to the indoor unit TIMER SET EE Noe NO eon When Refrigerant circuit address data is not set in the indoor unit is displayed Set the Refrigerant circuit address data again as per procedure 8 9 above UO zu We TH FR sA as GOOD gie 18 When Refrigerant circuit address data is set in the indoor unit properly Blinking changes to steady illumination Completion of address setting mode 10 Address setting mode is released and returns to normal display if the 8 SETTEMP WV button SETTEMP button and FAN button are pressed simultaneously p IRFAN a CEL Normal mode display Address setting mode is released automatically if no key is pressed for 60 seconds even the above buttons are not pressed Switch to Address setting mode as per procedure 1 above 11 After completing the ADDRESS SETTING be sure to turn off the power and turn it on again 10 FUNCTION SETTING This procedure changes the function settings used to control the indoor unit according to the installation conditions Incorrect settings can cause the indoor unit to malfunction Perform the FUNCTION SETTING according to the installation conditions using the remote controller Refer to the indoor unit installation manual for details
Download Pdf Manuals
Related Search
Related Contents
Burnham 4S Dimension Guide : Free Download, Borrow, and Streaming : Internet Archive MR365MEGANE4 – MEGANE II RENAULT Guida all`installazione WV-CW504SE - Psn Samsung NV100HD Kasutusjuhend Mode d`emploi du système de réservation par Internet avec 取扱説明書 - M Data Capture 2014 Installation and User Manual. Samsung 510N manual de utilizador 取扱説明書 - 三菱電機 取扱説明書 Copyright © All rights reserved.