Home
RADIO STROBE VARIANT INSTALLATION MANUAL
Contents
1. RADIO STROBE VARIANT INSTALLATION MANUAL MODEL NUMBERS 53 5310 Sounder Strobe Unit 53 5311 Sounder Strobe Unit with Callpoint Input amp 53 5315 Strobe Only Unit EMS 5000 FIREPOINT Table of Contents Section Page No te LOGGING ON A RADIO SI ROBE 3 6 bea ate CALL POINT 9 2015 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT 1 Logging on a Radio Strobe If the installation has been ordered as a complete system the devices and panel will be supplied already pre programmed In this scenario proceed from section 2 If the devices are purchased separately they must be added manually to the system The process of adding radio devices to the 5000 FirePoint Control Panel is largely carried out automatically by the panel s own operating system It is usual practice for each device to require logging on to the system In such cases the following action must be taken When logging on the 53 5310 Sounde
2. 15 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM 5 5000 ENS 5 www emsgroup co uk Third Party Accredited ISO 90011150 13485150 14001 The information contained within this literature is correct at time of publishing The EMS Security Group Ltd reserves the right to change any infomation regarding products as part of its continual development enhancing new technology and reliability The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specification being written Fire Industry Association 2015 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM
3. and the screen will now display 7 Press 221100 then press the YES key and the screen will display 8 Press the V key until the screen displays 9 Press the YES key and the screen will now display 10 Press the YES key to change and the screen will now display 11 Press the 0 key and the screen will now display 12 Enter the slot number that you want to add a device to e g 125 then press the YES key and the Screen will now display 13 Press the key until the screen displays 14 Press the YES key and the screen will now display 15 Press and hold the logon button as shown in Figure 1 above for 2 3 seconds and the screen will now display 2015 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT 16 Press the YES key twice and the screen will now display 17 Press the NO key three times and the screen will now display Note After logging the device on to the system there will be two faults 13 fault is processor reset 2 fault is the Tamper Make sure the device tamper is clear by re establishing connection of the two parts as explained in section 3 then press the Silence and Reset buttons to clear the faults 18 After the faults have been cleared turn the control key to the OFF position and the screen will display 2 Sounder Volume The Sounder volume can be adjusted using the switch
4. es as shown below in Figure 2 The switch settings for the volume are dispatched as HIGH volume with switches 1 amp 2 both in the On position HIGH Medium Default 1 amp 2 On 1 On 2 Off Figure 2 Sounder switches are shown in Figure 3 Note Not applicable for the Strobe Only device 53 5315 Sounder Volume Configuration Sticker Sounder Volume Switches Where the Switch in an Upwards orientation the On Position Figure 3 2015 EMS Security Group Ltd All rights reece TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT 3 Unit Tamper The radio strobe has a tamper rod that when assembled should be placed into both of the tamper rod cavities as previously shown in Figure 1 4 Strobe Installation When installing ensure all strobes are sited in accordance with survey and design details Having already separated the logon sections we must now remove the two fixing screws for the strobe section When installing the 53 5311 we must also remove the two fixing screws for the auxiliary section Now disconnect the battery connection lead and other leads that obstruct access to the back box section Removing the batteries will expose the mounting holes as shown in Figure 4 NOTE It is important the top mounting hole is used to ensure movement is stopped and that unwanted tamper alarms are not generated 53 5311 Mounting Holes Figure 4 Affix the back box to the wall using no 8 coun
5. r Strobe Unit Remove q this section to Logon When logging on the 53 5311 Sounder Strobe Unit with Call point Input Remove q this section to Logon Remove this section to Logon As seen in figure 1 the box consists of two separate sections being the transmitter section and the battery back box section The strobe can be programmed to the system by the following procedure 2015 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT Tamper Tamper Rod Logon Button Rod Cavity Cavity 2 Battery Tamper Connection Rod Lead gt Sounder Volume Switches Figure 1 Check that all batteries are fitted and that the Battery Connection Lead is in place hence applying power to the transmitter section As shown above in Figure 1 To log on the device to the 5000 FirePoint take the device to the front of the panel Insert the key into the Panels Control Keyswitch located on the bottom right of the Panel Step Action Screen Display No 1 With the key in the ON position the screen will display 2 Press the 0 key and the screen will now display 3 Press the V key until the screen displays 4 Press the YES key and the screen will now display 5 Press the V key until the screen displays 2015 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT 6 Press the YES key
6. tersunk screws with suitable fixings Ensure that the strobes orientation is correct and that countersunk head screws are used so as to prevent the possibility of damaging the internal components 2015 EMS Security Group Ltd All rights TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT Now re insert the 3 x AA cells and 3 x C cell batteries as shown below in Figure 5 and ensure the supplied battery ribbon is wrapped around the first AA cell to enable easy removal of the batteries at a later date Power connector Figure 5 NOTE Observe the correct battery polarity as shown above Now reconnect the power lead between the back box and the front unit Also re establish the connection of any other leads previously removed for the back box installation Locate the transmitter section into the back box ensuring that the tamper rod is correctly in place Now finally secure the sections into place by reapplying the fixing screws 2015 EMS Security Group Ltd All rights ce TSD242 Iss 3 25 06 15 AJM EMS 5000 FIREPOINT 5 Call point Input Wiring On the Sounder Strobe with Call point Input 53 5311 connections to the call point input have to be wired using 4k7 and 2k2 resistors in a normally closed circuit See Figure 6 The input sees 4K7 in a clear state When the 47 and 2k2 resistors are in series making 6 9 the device will send an alarm signal RESISTOR COLOUR CODES Y V R 4K7 Figure 6 0 2 20
Download Pdf Manuals
Related Search
Related Contents
Alarm Handling Manual เอกสารลำดับที่ 2 - Aeronautical Radio of Thailand LTD Final Report on the IOI 2002 Competition 取扱説明書 là - Phil Wake Manual PDF Gear Head FS4200BLU StarTech.com WIRC6PATPLRL networking cable 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file