1. Clear area for outlet quota above the roof slope 5 gt 10 REFERENCE DESCRIPTION CLEAR AREA MM c Distance measured at 90 from the roof surface 1300 a Height above the ridge of the roof 500 The outlet of a chimney ducted system must not be near obstacles that may create turbulence areas and or prevent proper expulsion of combustion products and maintenance operations to be carried out on the roof Verify the presence of other chimney caps or skylights and dormers FUMES EXHAUST SYSTEM PRODUCT REQUIREMENTS Temperature class In the event of a pellet appliance temperature classes below T200 are not allowed Soot fire resistance class The fumes exhaust system interlocked with appliances supplied by solid fuels require soot fire resistance and the specification must be indicated by the letter G followed by the distance from combustible materials in millimeters XX in compliance with UNI EN 1443 In the event of pellet appliances the fumes exhaust systems must be airtight if double designation elements are used G and O with or without seal elastomer for connecting the appliance to the chimney one must comply with the minimum distance XX in millimeters indicated for designation G in the event of fire due to soot one must ensure the restoration of the initial conditions by replacing the gaskets and damaged items and cleaning those remaining in use
2. UNI TS 11278 2008 Metal chimneys flue liners flue ducts UNI 7129 point 4 3 3 Fire Brigade provisions local rules and regulations NATIONAL REGIONAL PROVINCIAL AND TOWN COUNCIL REGULATIONS One must also bear in mind all laws and national regional provincial and town council Standards present in the country in which the appliance has been installed TERMS AND DEFINITIONS Aeration Air renewal is required both for the disposal of the combustion products and to prevent mixtures with a hazardous content of non combusted gases Closed hearth appliance Appliance designed for operation with closed combustion chamber Forced draught appliance Appliance with ventilation in the fumes circuit and combustion with fumes flow at a positive pressure with respect to the environment Chimney Structure consisting in one or several walls containing one or several outflow airways The purpose of this predominantly vertical element is to expel the combustion products at a convenient height from the ground Smoke duct Component or components that connect the outlet of the heat generator to the chimney Chimney cap Device that placed on the chimney outlet allows the dispersion of the combustion products even in presence of adverse weather conditions Condensation Liquid products which form when the fumes temperature is lower or equal to the water dew point Ducting pipe Pipe made up of one or several predominantly vertical
3. STOP PRG1 OFF 00 00 Time 1 switch off MONDAY PRG1 OFF SUNDAY PRG1 OFF ON OFF Ignition switch off consents for various days SET PRG1 65 80 C Temperature setting for the 1 time span START PRG2 00 10 OFF 00 00 Time 2 ignition STOP PRG2 00 10 OFF 00 00 Time 2 switch off MONDAY PRG2 OFF SUNDAY PRG2 OFF ON OFF Ignition switch off consents for various days SET PRG2 65 80 C Setting room temperature for the 2 time slot START PRG3 00 10 OFF 00 00 Time 3 ignition STOP PRG3 00 10 OFF 00 00 Time 3 switch off MONDAY PRG3 OFF SUNDAY PRG3 OFF ON OFF Ignition switch off consents for various days SET PRG3 65 80 C Setting room temperature for the 3 time slot START PRG4 00 10 OFF 00 00 Time 4 ignition STOP PRG4 00 10 OFF 00 00 Time 4 switch off MONDAY PRG4 OFF SUNDAY PRG4 OFF ON OFF Ignition switch off consents for various days SET PRG4 ITAL ENGL DEUT FRAN ESPA KEY LOCK 65 80 C ON OFF Setting room temperature for the 4 time slot Selecting the language Key lock function activation disabling BRIGHTNESS OFF 10 31 ON OFF ENGLISH Selecting the display brightness Resets the values modifiable by the user back to the default values 27 OExtraflame SET POWER The following menu allows to
4. To replace them remove the battery holder as indicated in the figure at the back of the remote control remove or insert the battery according to the symbol on the remote control and on the battery itself For operation 1 CR2025 3V lithium buffer battery is required IF THE REMOTE CONTROL IS OFF BECAUSE IT HAS NO BATTERIES THE STOVE CAN BE CONTROLLED FROM THE CONTROL PANEL ON TOP OF IT The batteries used contain metals harmful WHILE REPLACING THE BATTERY PAY ATTENTION for the environment They must therefore TO THE POLARITY BY OBSERVING THE SYMBOL be disposed of separately in appropriate ON THE INSIDE COMPARTMENT OF THE REMOTE containers CONTROL ENGLISH 23 OExtraflame COMMISSIONING SETTINGS Once the power cable at the back of the stove has been connected move the switch also located on the back to 1 The switch at the back of the stove powers the stove board The stove remains off and a first screen appears on the panel reading OFF ADJUSTING TIME DAY MONTH AND YEAR Set clock allows to adjust the time and date CONTROLS PROCEDURE SENSOR Press key 6 and SET POWER will appear BAN MON TUE WED SUN Press key 2 several times until USER MENU is displayed HOURS 0 23 Confirm using key 6 MINUTES 00 59 SET CLOCK will appear DATE 13 Confirm using key 6 MONTH 1 12 Use key 4or5 to select the day YEAR 00 99 Proceed by pressing k
5. CLEAN JEOPARDISES SAFETY e FORPROPEROPERATION THE STOVE MUST UNDERGO ROUTINE MAINTENANCE BY A QUALIFIED TECHNICIAN AT LEAST ONCE A YEAR ROUTINE MAINTENANCE Some images could be offset from the original model Fumes motor disassembly and cleaning and fumes pipe and T new silicone in the provided points Inspections of gaskets ash drawer and door replace them and apply silicone where envisioned Combustion chamber and heat exchanger full cleaning including ignition plug pipe Feed box complete emptying and cleaning Room air fan disassembly and removal of dust and debris of any pellets Check air intake pipe and cleaning of the flow sensor IS EIS IN IS IS IS ENGLISH 35 OExtraflame ROUTINE MAINTENANCE Some images could be offset from the original model Fumes motor disassembly and cleaning and fumes pipe and T new silicone in the provided points Inspections of gaskets ash drawer and door replace them and apply silicone where envisioned Combustion chamber and heat exchanger full cleaning including ignition plug pipe Feed box complete emptying and cleaning Room air fan disassembly and removal of dust and debris of any pellets 000009 9 Check air intake pipe and cleaning of
6. Check cleanliness of the fumes pipe of the sensor in the primary air channel and the combustion chamber Check for the presence of pellets in the feed box NO The pellet feed box is empty Adjust pellet flow see Pellet feed adjustment IGNITION Pellet feed calibration inadequats Check the procedures described in the Ignition chapter NO IGNITION TANO Take the stove to OFF conditions using key 1 and repeat BLACK OUT 9 9 the procedure described in the Ignition chapter NO PELLETS e TERE Check for the presence of pellets in the feed box The motor reducer does not feed pellets Adjust the pellet flow see Pellet feed adjustment The door is not closed correctly Check hermetic door closure DEPR ALARM The ash drawer is not closed correctly Check hermetic closure of the ash drawer The combustion chamber is dirty Check cleanliness of the fumes pipe and the combustion The flue exhaust pipe is blocked chamber DEBIMETER Flow sensor faulty E E centre FAULT Sensor disconnected Possible air in the system vent the system Lack of adequate circulation Air in the system Lack of or inadequate safety zone H20 OVERTEMP Gitt The water in the stove has exceeded 95 C Possible circulator anomaly If the problem persists the reset operations must be carried out by an authorised technician Check closure of the door Door not closed properly Check that the burn pot is clear
7. INSPECTION AND MAINTENANCE Frequency of operations Maintenance of the heating system and of the appliance must be carried out on a regular basis according to the table below TYPE OF APPLIANCE INSTALLED lt 15kW 15 35 kw Pellet operated appliance 1 year 1 year Water operated appliances 1 r 1 r closed fireplaces thermo stoves thermo kitchens yea yea Boilers 1 year 1 year Fumes exhaust system 4 t of fuel used 4 t of fuel used For further details refer to the cleaning and maintenance chapter Inspection and maintenance report At the end of the inspection and or maintenance operations a report must be issued and released to the owner or person acting for him who must confirm its receipt in writing The report must indicate the situations encountered the action taken any components replaced or installed and any comments recommendations and requirements The report must be kept with the relative documentation In the inspection and maintenance report one must mention anomalies detected that cannot be removed which pose a risk to the safety of the user or serious damage to building components that have been tampered with If anomalies as per above were detected the owner or person acting for him must be warned in writing in the maintenance report to refrain from using the system until the safety conditions have been fully restored The inspection and maintenance report must include
8. Ignition tests Operation of the appliance must be verified with an ignition test i e for mechanical feed appliances one must complete the ignition test verify proper operation for at least the next 15 minutes and adjust the switch off For appliances installed in a hot water heating system closed fireplaces thermo stoves testing must also extend to the entire hydraulic circuit 18 ENGLISH OExtraflame Coverings and finishings The coverings and finishings must only be applied after having verified the proper operation of the appliance according to the indicated modalities TECHNICAL INSTALLATION DOCUMENTATION When installation is complete the installer must provide the owner or person acting for him according to the legislation in force with the declaration of conformity supplied with 1 the use and maintenance manual of the appliance and of the system components such as for example the smoke ducts chimney etc 2 photocopy or photograph of the chimney plaque 3 system booklet where applicable The installer must ask to be issued with a receipt stating that the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation Installation performed by several parties If the individual installation steps are carried out by different parties each must document the work carried out for the customer and the for the operator working on the next step
9. and clean TRAPDOOR FAULTY Burn pot dirty or clogged The automatic burn pot cleaning is blocked If the problem persists contact the service centre Possible air in the system vent the system ALARM The system pressure read by the pressure Possible lack of water or leaks due to anomalies in some MINIMUM PRESSURE switch is too low system component If the problem persists contact the service centre ALARM H20 probe failure Contact after sales centre H20 PROBE Possible air in the system vent the system ALARM The pressure of the water has exceeded en vesselsare not damaged MAX H20 PRESSURE the max threshold Check that the cold system is loaded at the correct pressure If the problem persists contact the service centre 38 ENGLISH QExtraflame ENGLISH OExtrafliame Riscaldamento a Pellet Extraflame S p A Via Dell Artigianato 12 36030 MONTECCHIO PRECALCINO VI ITALY FN 39 0445 865911 E 39 0445 865912 24 info Extraflame it www lanordica Extraflame com The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties 004276005 MU DIADEMA LILIANA IDRO 002
10. between the external and internal environment is equal to or less than 4 Pa Inthe presence of type B gas appliances with intermittent operation not intended for heating they must have their own aeration and or ventilation opening The air inlets must meet the following requirements they must be protected with grids metal mesh etc but without reducing the net useful section they must be made so as to make the maintenance operations possible positioned so that they cannot be obstructed The flow of clean uncontaminated air can also be obtained from a room adjacent to that of installation indirect aeration and ventilation as long as the flow takes place freely through permanent openings communicating with the outside The adjacent room cannot be used as a garage warehouse of combustible material or for any other activity with a fire hazard bathroom bedroom or common room of the building FUMES EXHAUST SYSTEM GENERAL REQUIREMENTS The heat generator works in a vacuum and has an output fan for fume extraction Each appliance must be connected to a suitable fumes exhaust system and ensure adequate dispersion of the combustion products into the atmosphere The combustion products must discharged above the roof Direct discharge from the wall or towards closed spaces is forbidden even with clear skies In particular it is forbidden to use flexible and extendible metal pipes The chimney should only receive the exhaust of the smo
11. elements specifically suitable for collecting and expelling the fumes as well as to withstand the relative components and any condensate over time suitable to be installed in a chimney existing or new technical compartment even in new buildings Sealed installation Installation of an appliance with sealed operation so that all the air required for combustion is taken from outside Maintenance Set of procedures required to ensure and maintain safety and functionality over time and maintain the efficiency of the system within the prescribed parameters Chimney system Chimney installed using a combination of compatible components manufactured or specified by a sole manufacturer whose product liability covers the entire chimney Fumes exhaust system Flue gas exhaust system independent from the appliance made up of a smoke duct chimney or individual flue and chimney cap Radiation area Area immediately in front of the hearth in which the radiant heat caused by combustion is diffused Reflux area Area beyond the extrados of the roof in which overpressure or depressions occur which may affect the proper discharge of the combustion products ENGLISH 11 OExtraflame FUNCTIONAL OPERATIONS DIAGRAM State of the art installation and proper system operation include a series of activities 1 Preliminary activities Verification of the suitability of the power of the heat generator based on the characteristics of the system
12. or than the sum of the inlet cross sections in the event of several valves serving a single pipe The discharge piping of the safety valve must be realised in order not to prevent the regular functioning of the valves and not to cause damages to persons the discharge must flow immediately near the safety valve and be accessible and visible The diameter of the discharge piping must not however be lower than that of the outlet connection of the safety valve For diameter of outlet connection it is intended the minimum internal diameter on the valve outlet upstream of the eventual internal threading CLOSED EXPANSION VESSEL Warnings check that the preload of the expansion vessel is set to 1 5 bar The vessel maximum exercise pressure must not be lower than the calibration pressure of the safety valve increased by overpressures characteristic of the same valve bearing in mind the eventual level difference between vessel and valve and the pressure generated by the functioning of the pump The capacity of the expansion vessel s is evaluated depending on the total system capacity as results from the project The closed expansion vessels must comply with the provisions concerning the design manufacturing conformity assessment and use of pressure appliances Intercepting objects or section decreases must be inserted practiced on the connection piping which can be constituted by system portions The insertion of a three way intercepting valve which allows c
13. tends to become encrusted blocking the holes for air intake due to the excessive pellet feed as it is only burned partially The adjustment to be performed is in percentage Therefore a modification of this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from 30 to 2096 CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until SET ADJUSTMENTS is displayed Confirm using key 6 Press key 2 until PELLET is displayed Press 4 to increase the load and 5 to decrease it Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 9 USER MENU SET CLOCK see chapter commissioning settings ENGLISH 29 OExtraflame CHRONO The chrono allows to program 4 time spans within a day to use every day of the week The switch on and switch off time can be set in every time slot along with the days of use of the programmed time slot and the desired water temperature 65 80 C PROGRAMMING EXAMPLE Let s suppose that the weekly programmer function is to be used and 4 time slots are to be used in the following way 1st time slot from 08 00 to 12 00 every day of the week excluding Saturday and Sunday 2nd time slot from 15 00 to 22 00 only on Saturday and Sunday both times with a water temperature setting of 75 C 1ST TIME SLOT SWITCH OFF CONTROLS PROCEDURE Use keys 4 5 to enter the time 12 00 STO
14. the behaviour of the pump used on our thermo products at the speeds that can be set 1 0 0 0 5 1 0 1 5 2 0 2 5 Flow rate m h 10 ENGLISH OExtraflame DEVICES in the relevant models Door micro switch With the door open the operation of the burn pot cleaning system is blocked Electronic pressure switch in the event of inadequate pression it sends the machine in alarm conditions F 2 5 A 250 V fuse stoves protects the machine from violent current surges 85 C calibrated mechanical bulb with manual rearm intervenes by blocking fuel feed if the pellet tank t reaches the limit of 85 C Rearm must be performed by qualified staff and or the manufacturer s technical after sales assistance Pellet tank temperature control probe if the tank over heats the machine automatically modulates to return to normal temperature values Mechanical air pressure switch blocks the pellet in the event of insufficient depression REFERENCE STANDARDS The installation must be in compliance with UNI 10683 2012 heat generators fed with wood and other solid fuels installation The chimneys must be in compliance with UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNI EN 1806 in the event of non metallic chimneys EN 13384 1 13384 chimneys Thermal and fluid dynamic calculation methods UNI EN 1443 2005 chimneys general requirements UNI EN 1457 2012 chimneys clay ceramic flue liners
15. the main information of the technician or company who performed the inspection and or maintenance operations with their contact details date of intervention and the signature of the operator ENGLISH 19 OExtraflame PELLETS AND FEEDING Pellets are made by applying high pressure to sawdust or wood waste products not containing paint from sawmills carpentry and other activities related to processing and working with wood Given that it does not use any glue to hold it together this type of fuel is completely environmentally friendly In fact the compactness of the pellets over time is guaranteed by a natural substance found in the wood itself wood coal In addition to being an environmentally friendly fuel in that it pushes wood residues to the limits pellets also have technical advantages While wood has a calorific value of 4 4kWh kg with 15 humidity after around 18 months of seasoning the calorific value of pellets is 5 kWh kg Pellet density is 650kg m3 and the water content is equal to 8 of its weight For this reason they do not require seasoning in order to arrive at a sufficiently adequate degree of heat yield The pellets used must comply with the characteristics described by the following standards EN PLUS UNIEN 16961 2 class Al or A2 e NORMM 7135 DIN PLUS 51731 The manufacturer always recommended using pellets with a diameter of 6 mm with its products PELLET STORAGE In order to ensure problem fr
16. this control can the flue fitting be mounted between the boiler and the flue A check of the connections with pre existing flues is recommended AUTOMATIC THERMOSTATIC MIXER VALVE MANDATORY It is required to create an adequate anti condensation circuit that ensures a return temperature for the appliance of at least 55 C The anti condensation valve for example is applied in solid fuel boilers as it prevents the return of cold water in the heat exchanger Routes 1 and 3 are always open and together with the pump installed on the return they guarantee water circulation inside the biomass boiler exchanger A high return temperature allows efficiency improvement reduces formation of smoke condensation and prolongs the life span of the generator Valvesonthe market have differentcalibrations The manufacturer advises use of model 55 c with 1 hydraulic connections Once the valve calibration temperature is reached route 2 is opened and the boiler water goes to the system via the flow Valve sold as an accessory optional 8 ENGLISH OExtraflame LILIANA IDRO DIADEMA IDRO BASIC HYDRAULIC SYSTEM DIAGRAM a 2 YN S T1 T T M T2 LI VB 3 1 2 G VMTA sil KEY A Combustion air inlet 60mm B Smoke ex
17. time slot must be programmed The sequence to be followed is the same and is repeated as per the 1ST TIME SLOT SWITCH ON On this occasion it is only necessary to enter the time for example start at 15 00 and Stop at 22 00 and to activate the days Saturday and Sunday by setting them at ON RECOMMENDATIONS EXAMPLE The ignition and switch off times must be within the arc of Switch on time 07 00 one day from 0 to 24 and not over several days Before using the chrono function set the current day and Switch off time 18 00 time Therefore check that the points listed in the Set clock sub chapter have been followed so that the chrono function works As well as programming it activate it as well Switch on time 22 00 Switch off time 05 00 INCORRECT TO ENABLE THE CHRONO FOLLOW THE INSTRUCTIONS AS DESCRIBED IN THE ENABLE CHRONO CHAPTER WHEN THE WEEKLY PROGRAMMER IS ACTIVE THE RELEVANT ICON WILL LIGHT UP ON THE CONTROL PANEL ADJUSTING LANGUAGE see chapter commissioning settings DISPLAY The DISPLAY menu contains two sub menus Key lock Brightness KEY LOCK The menu allows to lock the display keys like mobile phone CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until USER is displayed Confirm using key 6 Press key 2 until DISPLAY Confirm using key 6 KEY LOCK will appear confirm with key 6 Use keys 4 5 to enable ON disab
18. times until SET ADJUSTMENTS is displayed Press key 6 P d STAND BY will appear Q O Use keys 4 5 to select enable ON disable OFF Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 999 28 ENGLISH OExtraflame ENABLE CHRONO The boiler chrono can be enables disables from this menu CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until SET ADJUSTMENTS is displayed Press key 6 Press key 2 until ENABLE CHRONO is displayed Use keys 4 5 to enable ON disable OFF Press key 6 to confirm and key 1 to return to the previous menus up to the initial status PELLET ADJUSTMENT The following menu allows to adjust the percentage of pellet feed If the stove has functioning problems owing to the quantity of pellets adjust pellet feeding directly from the control board The problems correlated to the amount of fuel can be divided into 2 categories NO FUEL the stove can never develop a suitable flame tending to remain very low even at high powers atminimum power the stove tends to almost switch off taking the stove into NO PELLETS alarm condition when the stove displays the NO PELLETS alarm there may be non burned pellets inside the burn pot EXCESS FUEL the stove develops a very high flame even at low power the panoramic glass is very dirty obscuring it almost totally the burn pot
19. E Temperature safety sensors On the machine or not exceeding 30 cm Missing devices because not as per standard Not exceeding one metre on the flow pipe The domestic heating appliances with automatic feeding must be equipped with a fuel block thermostat or with a cooling circuit set up by the appliance manufacturer The cooling circuit must be activated by a thermal safety valve in order to ensure that the limit temperature set forth by the Standard is not exceeded Connection between the power supply unit and the valve must be free from interceptions The pressure upstream from the cooling circuit must be at least 1 5 bar TYPE OF SYSTEM There are two different types of system Open vessel plant and closed vessel plant The product has been designed and realised to work with closed vessel systems CLOSED VESSEL PLANT System in which the water it contains is not in direct or indirect communication with the atmosphere Generally the closed vessel system has one of the following expansion vessels Pre loaded closed expansion vessel with membrane impermeable to the passage of gases Automatic closed expansion system with compressor and membrane impermeable to the passage of gases Automatic closed expansion system with transfer pump and membrane impermeable to the passage of gases Expansion system without diaphragm GENERALITY The closed systems must have Safety valve Pump control thermostat Acoust
20. GLISH OExtraflame VA EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Protection from rain and wind Protection from rain and wind T Steel plate airtight gt gt Max 3 mt g Ae 3 595 UR LEX Insulated T IT fitting with gt T fitting with LEX inspection plug T fitting with inspection plug gt inspection LX plug S 020 p 4 It is mandatory to use airtight pipes CHIMNEY In addition to the general requirements the chimneys for releasing combustion products into the atmosphere must operate under negative pressure operation under positive pressure is not allowed havea preferably circular internal section square or rectangular sections must have rounded corners with a radius of no less than 20 mm hydraulically equivalent sections may be used as long as the ratio between the longer side and the shorter side of the rectangle which circumscribes the section is in any case no greater than 1 5 be designed for fumes be designed for fumes expulsion be predominantly vertical and have no narrowing along their entire length have no more than two direction changes with a slope angle no greater than 45 be fitted with in the event o
21. ON AND SAFETY DEVICES The installation relative system connections commissioning and inspection of correct functioning must be carried out perfectly in total compliance with Standards in force both national regional and municipal as well as these instructions For Italy installation must be carried out by professionally authorised staff Ministerial Decree dated 22 01 08 n 37 The manufacturer declines all responsibility for damages to objects and or persons caused by the system SAFETY DEVICES FOR CLOSED VESSEL SYSTEM According to the UNI 10412 2 2009 Standard in force in Italy the closed systems must have safety valve pump control thermostat acoustic alarm activation thermostat temperature indicator pressure indicator acoustic alarm regulation automatic circuit breaker switch automatic circuit breaker block switch block thermostat circulation system expansion system safety dissipation system incorporated with the generator with thermal safety valve self activated whenever the appliance does not have a temperature self adjustment system DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection 6 ENGLISH OExtraflame Whenever the generators lack a device those missing can be installed on the generator flow pipe within a distance no greater than 1m from the machine COMPONENT DISTANC
22. P PRG1 Press key 6 once and SET POWER will SET SEH OFF time of the 1st time slot appear USER Press key 2 until SET USER appears To confirm and continue programming STOP PRG1 press button 6 Press button 3 to go 12 00 back to the previous parameter ENABLING THE 1ST TIME SLOT DAYS To enable ON disable OFF the days MONDAY PRG1 Press key 6 to confirm k ON SET CLOCK will appear use Keys dandis i SET CHRONO Keys 2 and 3 to scroll the various days Press key 2 until SET CHRONO appears select from Monday to Friday on ON FRIDAY PRG1 excluding Saturday and Sunday OFF ON To confirm and proceed press key 6 1ST TIME SLOT 2 TEMPERATURE SETTING Press key 6 to confirm and continue programming START PRG1 Using buttons 4 5 select the desired SET PRG1 OFF H20 temperature 75 C START PRG1 OFF appears 65 80 C To confirm and proceed press key 6 1ST TIME SLOT SWITCH ON 2ND TIME SLOT SWITCH ON Use keys 4 5 to enter the time 08 00 At this point the second time slot must which corresponds to the switch on START PRG1 be programmed START PRG2 time of the 1st time slot 08 00 OFF To confirm and continue programming press button 6 Press button 3 to go back to the previous parameter 30 The sequence to be followed is the same and is repeated as for the 1ST TIME SLOT switch on ENGLISH OExtraflame 2ND TIME SLOT SWITCH ON At this point the second
23. QeExtraflame Riscaldamento a Pellet DIADEMA LILIANA IDRO IDRO USER MANUAL ENGLISH INGLESE OExtraflame OExtraflame We thank you for having chosen our company our product is a great heating solution developed from the most advanced technology with top quality machining and modern design aimed at making you enjoy the fantastic sensation that the heat of a flame gives in complete safety ENGLISH 5 WARNINGS A 5 SAFETY 5 ROUTINE MAINTENANCE scscccssssssssssssssssssssncssssenssssssnsensssnssasssassasssssenssnsseaseassoasonssssseassnssoasoassoasoacsssseassasseassassoassasssssoasenssoas 5 HYDRAULIC SYSTEM INSTALLATION AND SAFETY DEVICES ee ae RIE aa SAFELY DEVICES FOR CLOSED VESSEL SYSTEM ee en ag DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD IOC E CLOSED VESSEL PLANT m SAFETY VALVES etes CLOSED EXPANSION VESSEL i COMMISSIONING CHECKS 8 AUTOMATIC THERMOSTATIC MIXER VALVE MANDATORY en 8 LILIANA IDRO DIADEMA IDRO BASIC HYDRAULIC SYSTEM DIAGRAM 22uss00sss0n0sonssonsesnnsnonenonssnnnsnonsnonssnnnsnnnsnnnennnnsnnnene 9 STOVE POSITIONING 91347 6 REFERENCE STANDARDS 2 s0ss00s000nesnsennsssonenonsnnnnennnsnnnennnssnnnsnnnennnnennnsnsnennnssnnnsnnnsnnnsnnnnsnnnsnnnsnnnnsnnnsnnnsnnnssnnnsnnnsnnnsnnnsnnnnsanen GENERAL See INSTALLATION FUMES EXHAU
24. ST SYSTEM GENE VAR OUR MENS E nenn e mn rmn ERE 14 SIVIOKE A e eere LLL MEE enne 15 CHUMAR o A Mm eren Beer eene 17 EUMES EXHAIUSISYSTEMIBRO BUG REQUIREMENTS Anm 18 on BUSTIONIBBOSDUCTSNSBIIEEIEIU E lt lt n 18 TECHNICAL ASTA LATION PACOMEN TAT EA SEN 19 hid luz FEEDING CE ooo oss La LL EL 20 ENGLISH 3 OExtraflame CONTROL PANEL DISPEAY ICONS a fm Ulnnnn BASIC INSTRUCTIONS THE REMOTE CONTROL ENABLE DELAYED SWITCH OFF AND REPLACEMENT OF BATTERIES ueteres iaia Eeer On ADJUSTING TIME DAY MONTH AND YEAR ADJUSTING THE LANGUAGE aaa OPERATION AND LOGIC DopHMIODNUnu ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY DEACTIVATED SUE Ta SET POWER OTHER FUNCTIONS on AIR DISCHARGE n
25. ashing the safety device is active H20 temperature gt 85 C It indicates the puffer request with an additional board Off puffer satisfied pump off Flashing the puffer request exists but the work conditions are not satisfied pump off On the puffer is in request mode and the work conditions are satisfied pump on ENGLISH 21 OExtraflame GENERAL MENU gt cosac exi PARAMETER SCROLLING NEXT 2 PREVIOUS 3 OFF GIG a a e 5 435 MODIFY SETTINGS DATA INCREASE 4 DECREASE 5 6 6 CONFIRM ACCESS MENU e SET POWER 2 i gt SETTEMPERATURE gt SET H20 Y gt SET ADJUSTMENTS 6 BURN POT CLEANING 5 Y Y 22 STATUS HE STOVE STATUS STAND BY ENABLE CHRONO e PELLETS gt USER MENU SET CLOCK SET CHRONO 5 LANGUAGE Si DISPLAY TECHNIC SET KEY LOCK BRIGHTNESS RESERVED TO THE QUALIFIED TECHNICIAN amp RESET BASIC INSTRUCTIONS Before lighting the stove the following points must be The following recommendations must be followed the first verified times the stove is ignited The hydraulic system must be completed in compliance Faintsmells may be produced due to the drying of the with the guidelines of the regulations and the manual paints and silicones used Do not remain t
26. ear Press key 2 several times until USER is displayed Confirm using key 6 Press key 2 until RESET appears Confirm using key 6 Press keys 4 5 to select ON and press key 6 DONE will appear on the display to confirm o o o OTHER FUNCTIONS AIR DISCHARGE This function allows to bleed any air in the stove Once the function has been activated the pump indicator light is activated on the display for 15 minutes 30 seconds the pumps will be powered alternating with 30 seconds of downtime To activate the function With the stove OFF press keys 1 and 4 at the same time enter the password 77 using keys 4 and 5 and confirm with key 6 Cut the power to interrupt FIRST LOAD This function allows to activate the pellet feeding motor reducer for continuous functioning To activate the function When the stove is cold and OFF press keys 2 and 5 at the same time for a couple of seconds the scrolling message first load will appear on the display To interrupt continuous loading simply press key 1 32 ENGLISH QEXxtraflame MAINTENANCE MAINTENANCE WARNINGS Inspection and maintenance operations must be carried out by specialised technicians who are aware of the directions reported in this manual Before carrying out any work make sure that The power cable s plug has been pulled out as the generator might have been programmed to turn on All the generator parts are co
27. ecautions After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning SAFETY The generator must not be used by persons including children with reduced physical sensory and mental capacities or who are unskilled persons unless they are supervised and trained regarding use of the appliance by a person responsible for their safety Children must be checked to ensure that they do not play with the appliance Do not touch the generator when you are barefoot or when parts of the body are wet or damp The safety and adjustment devices must not be modified without the authorisation or indications of the manufacturer Do not pull disconnect twist electric cables leaving the stove even if disconnected from the electric power supply mains It is advised to position the power supply cable so that it does not come into contact with hot parts of the appliance The power supply plug must be accessible after installation Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are essential for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be c
28. ed previously have been checked press key 1 for three seconds to ignite the stove 15 minutes are available for the ignition phase After ignition and having reached the control temperature the stove interrupts the ignition phase and passes to STARTING STARTING During the start up phase the stove stabilises combustion increasing it progressively to then start ventilation and pass on to WORK WORK During the work phase the stove reaches the set power see following item ADJUSTING POWER SETTING Set the operating power from 1 to 5 Power 1 minimum level Power 5 maximum level H20 TEMPERATURE SET ADJUSTMENT Set the boiler temperature between 65 80 PUMP OPERATION The pump activates water circulation when the t of the water inside the stove reaches 60 C As the pump always functions above 60 an always open heating area is recommended to make product functioning homogenous preventing overheating blocks Normally this area is defined Safety zone BURN POT CLEANING At pre set intervals the stove performs burn pot cleaning switching the machine off When the cleaning phase is finished the stove will re start automatically and continue its work going back to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to modulate automatically bringing itself to the minimum power If the temperature increases beyond the set point it will automatically
29. ee combustion pellets must be stored in a dry place Open the tank lid and load the pellets using a scoop THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL WILL AFFECT THE FUNCTIONALITY OF YOUR C GENERATOR AND MAY LEAD TO THE TERMINATION OF THE WARRANTY AND CESSATION OF ANY ACCOMPANYING RESPONSIBILITY ON THE PART OF THE MANUFACTURER 20 ENGLISH OExtraflame CONTROL PANEL BUTTON ON OFF DISPLAY OF VARIOUS TEXT MESSAGES TO ACCESS THE MENU o OPERATION POWER ADJUSTMENT EN TEMPERATURE SETTING DISPLAY ICONS KEY Indicates the receipt of the radio signal On during radio communication Off no radio communication Flashing serial port excluded Indicates the stove modulation On the stove is working at the set power Flashing the power at which the stove is working is different to the power set the stove is modulating for various reasons Indicates the presence of an alarm On indicates the presence of an alarm Off indicates the absence of alarms Flashing indicates the deactivation of the depression sensor It indicates weekly programming functioning Indicator on weekly programming active Indicator off weekly programming disabled Indicates the water temperature status Off the T read by the probe is over the set temperature set On the T read by the probe is below the set temperature set Indicates the contact of the external additional thermostat Clo
30. entions aimed at reducing degradation due to normal use as well as dealing with accidental events entailing the need of first interventions which however do not modify the structure of the system upon which one is intervening or its intended use according to the requirements laid down by the technical standards in force and by the manufacturer s use and maintenance manual ENGLISH 5 OExtraflame HYDRAULIC SYSTEM Certain concepts referring to the Italian UNI 10412 2 2009 Standard are described in this chapter As previously described when installing all national regional provincial and town council Standards in force provided by the country in which the appliance has been installed must be complied with TABLE OF DEVICES FOR CLOSED VESSEL SYSTEM PRESENT AND NOT PRESENT IN THE PRODUCT Safety valve Pump control thermostat managed by the water probe and board program NN Acoustic alarm activation thermostat Water temperature indicator display Pressure transducer with display Acoustic alarm Automatic circuit breater switch managed by board program Pressure transducer with minimum and maximum pressure switch alarm Water overheating automatic circuit breaker blocking thermostat Circulation system pump SRI RE Expansion system During installation of the stove it is MANDATORY to adjust the system with amanometer in order to display the water pressure INSTALLATI
31. eu MEO ip MAINTENANCE DAILY CLEANING TO BE CARRIED OUT BY THE USER cccssssssssssssesssssssssscsssccesscsscscscsssscsssscsscsssssssccsssscsscsesssssccssosseseses DISPLAYS y 4 ENGLISH OExtraflame WARNINGS This instructions manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to another owner or user or if transferred to another place If it is damaged or lost request another copy from the area technician This product is intended for the use for which it has been expressly designed The manufacturer is exempt from any liability contractual and extracontractual for injury damage caused to persons animals and objects due to installation adjustment and maintenance errors and improper use Installation must be performed by qualified staff which assumes complete responsibility for the definitive installation and consequent good functioning of the product installed One must also bear in mind all laws and national regional provincial and town council Standards present in the country in which the appliance has been installed as well as the instructions contained in this manual The Manufacturer cannot be held responsible for the failure to comply with such pr
32. ey 2 Use the same procedure 4 or 5 to set and key 2 to move forward to adjust the hours minutes day month and year Press key 1 several times to confirm and exit the menu ADJUSTING THE LANGUAGE It is possible to select the preferred language to display the various messages SET LANGUAGE CONTROLS PROCEDURE Press key 6 and SET POWER will appear ENGLISH Press key 2 several times until USER MENU is displayed LANGUAGE GERMAN Confirm using key 6 FRENCH SET CLOCK will appear SPANISH Press key 2 until SET LANGUAGE appears Confirm using key 6 Selectthe language using key 4 or 5 Press key 1 several times to confirm and exit the menu DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION C DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE FILLING PHASE IN THE EVENT OF CONTINUOUS NO IGNITION CONTACT AN AUTHORISED TECHNICIAN BURN POT upper DIVIDER KEEP THE CORRECT POSITION AS INDICATED IN THE FIGURE ITIS FORBIDDEN TO USE THE APPLIANCE WITHOUT THE DIVIDER AND OR GLASS PROTECTION SEE THE FIGURE TO THE SIDE ITS REMOVAL JEOPARDISES THE SAFETY OF THE PRODUCT AND C IMMEDIATELY VOIDS THE WARRANTY PERIOD IN THE CASE OF WEAR OR DETERIORATION REQUEST AFTER SALES ASSISTANCE FOR REPLACEMENT OF THE PART REPLACEMENT THAT IS NOT UNDER GUARANTEE AS THE COMPONENT IS SUBJECT TO WEAR 24 ENGLISH OExtraflame OPERATION AND LOGIC IGNITION Once the basic instructions list
33. f operating in damp conditions a device for reflux drainage condensation rainwater Ducted system A ducted system can be installed with one or more ducts operating only with negative pressure with respect to the environment The flexible hose compliant with UNI EN 1856 2 with T400 G characteristics meets the requirements CHIMNEY CAPS The chimney caps must meet the following requirements they must have a useful outlet section no less than double of that of the chimney ducted system on which it is installed they must be adapted in order to prevent the penetration of rain and snow in the chimney ducted system they must be built so that in the event of winds coming from all directions and from any angle the expulsion of combustion products is in any case ensured they must be free from mechanical intake aids ENGLISH 17 OExtraflame COMBUSTION PRODUCTS OUTLET QUOTA The outlet quota is determined by measuring the minimum height between the roof covering and the lower point of the fumes expulsion section into the atmosphere this quota must be outside the reflux area and at an adequate distance from obstacles which hinder or make the expulsion of the combustion products difficult or from openings or accessible areas Reflux area The outlet quota must be outside the reflux area calculated according to the indications below Near the ridge one considers the lowest between the two Buffer area for outlet quota
34. haust outlet 120mm T1 3 bar safety valve 1 2 T2 Boiler flow output 1 T3 Boiler return inlet 1 M Pressure Gauge T Thermometer G Filling system Safety valve discharge SI System exhaust VB Balance valve VMTA Thermostatic mixer valve 55 C VMS Domestic hot water mixing valve IT ISRECOMMENDED TO CONSULT THE TEMPLATES MANUAL AT FOR FURTHER INFORMATION RELATIVE TO THE C HYDRAULIC CONNECTIONS AIR INTAKE FLUE EXHAUST AND DIMENSION SPECIFICATIONS OF THE PRODUCT IN QUESTION ENGLISH 9 OExtraflame STOVE POSITIONING For correct product functioning it is recommended to position it so that it is perfectly level using a spirit level REARMS The figures below illustrate the positions of the tank 85 C and 2 100 C rearms Contact the qualified technician if one of the rearms should be triggered so as to verify the cause e FEATURES DIADEMA IDRO LILIANA IDRO Water content of the thermo product heat exchanger I 21 Volume of expansion vessel integrated in the thermo product I g 3 bar safety valve integrated in the thermo product SI Minimum and maximum pressure switch integrated into the thermo product SI Pump integrated into the thermo product SI Pump max head m 5 9 ENVISION A POSSIBLE ADDITIONAL EXPANSION VESSEL DEPENDING ON THE SYSTEM WATER CONTENT Head m The diagram to the side illustrates
35. he environment The tank must be full of pellets for long periods combustion chamber must be clean not touch the surfaces as they could still be burn pot must be completely free and clean unstable the hermetic closure of the fire door and the ash Airthe room well several times drawer hardening of the surfaces is terminated after several Check that the power supply cable is connected correctly heating processes The bipolar switch in the rear right part must be positioned This appliance must not be used to burn waste on 1 Extraflame has an optional additional board that allows the boiler the following further functions when managing the system The table below indicates the various possibilities that the optional can offer DHW Storage Management Puffer Management 3 heating areas Instant DHW option Puffer pump or 4th heating area management Anti legionella management for DHW storage DHW storage chrono management Auxiliary output management and control 22 ENGLISH OExtraflame THE REMOTE CONTROL All that can normally be implemented through the LCD can be adjusted using the remote control The table below provides a detailed description of the various functions 1 ON OFF Pressing the key for three seconds the stove will switch on or off 2 POWERINCREASE Pressing the key will
36. he support surfaces and or points must have a suitable load bearing capacity to support the weight of the appliance of the accessories and coatings The adjacent side and rear walls and the supporting surface must be made of non combustible material Installation near combustible materials or those sensitive to heat is permitted as long as there is a suitable safety distance which for pellet stoves is equal to REFERENCES INFLAMMABLE OBJECTS NON INFLAMMABLE OBJECTS A 200 mm 100 mm B 1500 mm 750mm C 200 mm 100 mm figure 1 Inspection figure 2 9 Air inlet S floor protection In any case the temperature of the adjacent combustible materials must not reach a temperature equal to or greater than the room temperature increased by 65 C The minimum volume of the premises in which to install the appliance must be greater than 15 m ENGLISH OExtraflame VENTILATION AND AERATION OF THE INSTALLATION PREMISES Ventilation is deemed sufficient when the room is equipped with air inlets according to the table Air inlet See figure 2 Percentage of the 5 net opening section with Minimum net opening value of Applisncesateqones end respect to the appliance fumes the ventilation duct outlet section Pellet stoves UNI EN 14785 80 cm Boilers UNI EN 303 5 50 100 cm In any case ventilation is deemed sufficient when the pressure difference
37. ic alarm activation thermostat Temperature indicator Pressure indicator Acoustic alarm Adjustment automatic circuit breaker switch Automatic circuit breaker switch block thermostat Circulation system Expansion system Safety dissipation system incorporated with the generator with thermal safety valve self activated whenever the appliance does not have a temperature self adjustment system 999999 SAFETY VALVES The load capacity of the safety valve must allow the discharge of a quantity of vapour not lower than O 0 58 kg h where Q is the useful outlet power to the generator water expressed in kilowatt The diameter of the minimum net transversal section of the valve inlet must not be lower than 15 mm The valve load pressure equal to the calibration pressure increased by the overpressure cannot exceed the maximum exercise pressure of the heat generator The designer must check that the maximum pressure existing in every point of the system does not exceed the maximum exercise pressure of its every component The safety valve must be connected to the upper part of the heat generator or outlet pipes very close to the generator The length ofthe piping between the generator coupling and the safety valve must not exceed 1 m The piping connecting the safety valve to the heat generator must not be interrupted and must not have in any point a cross section lower than than that of the safety ENGLISH 7 OExtraflame valve inlet
38. increase the operating power 3 POWER DECREASE Pressing the key will decrease the operating power 4 T INCREASE The set temperature can be increased by pressing this key 5 T DECREASE The set temperature can be decreased by pressing this key 6 rar ora ta Pressing the key once will enable or disable the chrono The delayed switch off can be set by pressing this key 7 ENABLE DELAYED For example if the stove is set to switch off in an hour it shall switch off SWITCH OFF automatically once the set time elapses displaying the countdown every minute for delayed automatic shutdown 8 MENU This key allows to access the user and technical menu the technical menu is reserved for assistance 9 INCREASE The set temperature can be increased by pressing this key 10 ESCKEY 77 or display and returns to the 11 BACK The key returns to the display of the various menus 12 CONFIRMATION KEY adjustments made during the user menu 13 FORWARD The key moves forward in the various menus 14 ENABLE F1 FUNCTION Pre set key for future applications 15 DECREASE The key decreases the value to be set 16 STOVE STATUS Pressing this key will display the general status of the stove Important note the numbers shown on the remote control are purely indicative and are not present on the remote control supplied with the product TYPE AND REPLACEMENT OF BATTERIES The batteries are housed in the lower part of the remote control
39. ke duct connected to the appliance collective flues or conveying exhausts from hoods above cooking appliances of any kind or exhausts from other generators into the chimney itself or smoke duct are not allowed The smoke duct and the chimney must be connected with a continuity solution in order to prevent the chimney from resting on the appliance It is forbidden to have other air supply channels and pipes for plant engineering transit inside the fumes exhaust systems especially if over sized The components of the fumes exhaust system must be chosen in relation to the type of appliance to be installed in compliance with in the event of metal chimneys UNI TS 11278 with particular attention to what is stated in the specification in the event of non metallic chimneys UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNIEN 1806 considering especially temperature class pressure class fumes seal at least equal to the seal required for the appliance moisture resistance resistance to condensation class or level of corrosion and specification of the materials constituting the inner wall in contact with the fumes soot fire resistance class minimum distance from combustible materials Where due to high efficiency a pellet stove has fumes at a temperature of less than 160 C ambient see technical data it must be resistant to moisture The installer of the fumes exhaust system once the installation is complete and the relevant checks and i
40. ld The ashes are completely cold Periodically inspect the T shaped fitting on the smoke pipe located on the outlet of the generator by removing the hermetic container remove any ash and carefully place back the plug with the gasket HAVE THE GENERATOR VENTS AND SMOKE PIPE CLEANED AND CHECKED BY SPECIALISED PERSONNEL EVERY YEAR DAILY CLEANING TO BE CARRIED OUT BY THE USER Daily cleaning must be carried out by the generator s user with the utmost care after reading the instructions related to the procedures that need to be carried out later described in this manual The images are for illustration purposes Burn pot Remove the burn pot from the relevant compartment and free the holes using the appropriate fire irons supplied remove the ash from the burn pot using a suction device Suck the ash deposited in the brazier compartment Scrapers Cleaning of the heat exchangers allows to guarantee constant heat output through time This type of maintenance must be performed at least once a day To do this just use the relevant scrapers positioned in the upper part of the stove moving them up and down several times ENGLISH 33 OExtraflame WEEKLY Clean the combustion chamber and the ash drawer Empty the ash drawer every week or when required It is recommended to remove the ash in the combustion chamber at least once a week using a suitable vac
41. le OFF Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 0 0 0 6 0 USING THE KEY LOCK AFTER ACTIVATION 222 LOCK THE KEYBOARD PRESS KEYS 1 AND 5 AT THE SAME TIME UNTIL THE FOLLOWING APPEARS KEYS LOCKED TO UNLOCK THE KEYBOARD PRESS KEYS 1 AND 5 AT THE SAME TIME UNTIL THE FOLLOWING APPEARS KEYS FREE ENGLISH 31 OExtraflame BRIGHTNESS This menu allows to adjust the brightness of the display The possible settings range from OFF 10 to 31 Activating OFF the back light of the display will go off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until USER is displayed Confirm using key 6 Press key 2 until DISPLAY appears and confirm with key 6 Press key 2 until BRIGHTNESS appears and confirm with key 6 OFF Press keys 4 5 to select the brightness Press key 6 to confirm and key 1 to return to the previous menus up to the initial status RESET Allows to reset all values modifiable by the user to the default values The data is SET H20 75 C SET POWER 5 ENABLE CHRONO OFF START PRG1 OFF STOP PRG1 OFF MONDAY PRG1 OFF all chrono parameters OFF PELLET 00 BURN POT CLEANING 00 STAND BY OFF CONTROLS PROCEDURE Press key SET POWER will app
42. losed during normal functioning of the product When the appliance is functioning and hot to the touch especially all external surfaces attention must be paid 9 9 9 Check for the presence of any obstructions before switching the appliance on following a prolonged period of inactivity The generator has been designed to function in any climatic condition even critical In particularly adverse conditions strong wind freezing safety systems may intervene that switch the generator off If this occurs contact the technical after sales service and always disable the safety systems In the event the flue catches fire use suitable systems for suffocating the flames or request help from the fire brigade This appliance must not be used to burn waste Do not use any flammable liquids for ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas are top quality artisan products and as such can have micro dots crackles and chromatic imperfections These features highlight their valuable nature Due to their different dilation coefficient they produce crackling which demonstrate their effective authenticity To clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them 9 9 ROUTINE MAINTENANCE Based on Decree 22 January 2008 n 37 art 2 routine maintenance means interv
43. nd the fumes exhaust system by verifying the existence of documentation relating to the system existence and content of the chimney plaque suitability of the internal section of the chimney absence of obstructions all along the chimney predominantly vertical height and development of the chimney existence and suitability of the chimney cap distance of the outside wall of the chimney and of the smoke duct from combustible materials chimney type and material absence of other chimney connections 9 9 12 ENGLISH OExtraflame INSTALLATION Installation in premises with fire hazards is forbidden Installation in residential premises except for sealed operation appliances is also forbidden in which there are liquid fuel operated appliances with continuous or intermittent operation which draw the combustion air in the room in which they are installed or inwhich there are type B gas appliances intended for room heating with or without production of domestic hot water and in adjacent and adjoining premises or in which in any case the depression measured during installation between the internal and external environment is greater than 4 Pa Installations in bathrooms bedrooms and studio flats Installation in bathrooms bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken from the outside Installation premises requirements T
44. nspections have been made must fix the chimney plaque supplied by the manufacturer with the product in a visible manner near the fireplace and which must be completed with the following information 99 99 14 ENGLISH OExtraflame nominal diameter distance from combustible materials indicated in millimetres followed by the arrow and flame symbol installer data and date of installation Every time one must cross combustible materials the following indications must be complied with a 1 IP Rp a M IB 1 u 1 5 DESCRIPTION QUOTAIMM b Minimum distance of combustible materials from the intrados of the framework floor wall 500 b 1 Minimum distance of combustible materials from the extrados of the framework floor 500 a Minimum distance from combustible materials defined by the manufacturer G xxx The single wall pipes are indicated in white The insulated double wall chimney systems are indicated in grey One can disregard the quota only in the event of using an appropriate heat protection screen for example wall plate to protect the intrados of the framework floor SMOKE DUCT General requirements The smoke ducts must be installed in compliance with the following general requirements be equipped with at least one sealed outlet for eventual fumes sampling they mu
45. onnection between the vessel and the atmosphere for maintenance Operations is allowed Such device must be protected against accidental manoeuvres The connection pipe must be realised in order not to present scales or deposits storage points In case of more heat generators which feed the same plant or the same secondary circuit each heat generator must be connected directly to the expansion vessel or plant expansion vessels unit altogether dimensioned for the total volume of water contained in the same plant or the same independent circuit Where it is necessary to separate the individual heat generator from the expansion vessel or expansion vessels unit a three way tap must be applied on the connection piping between the generator and the vessel in order to ensure in every position the connection of the generator with the expansion vessel or with the atmosphere The expansion vessels the connecting pipes the bleed pipes and drain pipes must be protected from freezing where this phenomenon occurs The solution used for this purpose is described in the design COMMISSIONING CHECKS Before connecting the boiler a wash all system piping in order to remove any residues which might compromise the correct functioning of certain system components pumps valves etc b check to verify that the flue has adequate draft is not narrowed and that other appliances do not discharge into the flue This is to prevent unexpected power increases Only after
46. or external thermostat switches to the not satisfied status closed contact temperature to be reached it will re ignite N B stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY DEACTIVATED When the STBY function is deactivated the o o LED is fixed When the contact or external thermostat is satisfied open contact temperature reached the stove will go to minimum As soon as the contact or external thermostat switches to the not satisfied status closed contact temperature to be reached the stove will start to work again at the pre set power N B stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored ADDITIONAL THERMOSTAT INSTALLATION Switch the appliance off using the master switch positioned on the rear of the stove Remove the plug from the socket Refertothe electrical diagram to connect the two thermostat cables onto the relative clamps positioned on the rear of the machine one is red and the other one is black STBY clamp AUX Connection reserved for Extraflame conveyed waves accessories Contact the dealer for fur
47. sed contact the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open Flashing with contact closed the contact of the external additional thermo stat is closed and the STBY function is activated Flashing with contact open the contact of the external additional thermostat is open and the STBY function is activated It indicates functioning of the fumes motor Off flue gas motor deactivated On flue gas motor active Flashing breakdown contact technical after sales service It indicates the summer winter function with an additional board Off Activates the winter function On Activates the summer function Not used It indicates the boiler request with an additional board Off DHW satisfied pump off Flashing the puffer request exists but the work conditions are not satisfied pump off On the puffer is in request mode and the work conditions are satisfied pump on It indicates functioning of the pellet feed motor Off pellet feed motor deactivated On pellet feed motor active It indicates the heating request with an additional board Off heating satisfied pump off Flashing the heating request exists but the work conditions are not satisfied pump off the heating is in request mode and the work conditions are satisfied pump on It indicates pump operation Off pump deactivated On pump active Fl
48. set the power Minimum power 1 maximum power 5 CONTROLS PROCEDURE Press key SET POWER will appear Confirm using key 6 The POWER will be displayed Press 4 to increase the setting and 5 to decrease it Press key 6 to confirm and key 1 to return to the previous menus up to the initial status SET TEMPERATURE The following menu allows to set the boiler temperature The possible settings are 65 80 C CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until SET TEMPERATURE is displayed Confirm using key 6 Press 4 to increase the setting and 5 to decrease it Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 999 SET ADJUSTMENTS BURN POT CLEANING The menu allows to increase the frequency of the automatic burn pot cleaning CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several times until SET ADJUSTMENTS is displayed Confirm using key 6 BURN POT CLEANING will appear To increase the automatic cleaning frequency press 4 To go back to standard values 00 decrease by pressing 5 Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 99999 STAND BY The Stby function is used if immediate stove switch off or modulation via an additional thermostat is desired CONTROLS PROCEDURE Press key 6 and SET POWER will appear Press key 2 several
49. st be insulated if they cross through rooms that are not to be heated or outside the building they must not cross rooms in which the installation of combustion appliances is forbidden nor in other premises compartmentalised against fire or with a fire hazard nor in rooms and or areas that cannot be inspected they must be installed so as to allow normal thermal expansion they must be fitted to the opening of the chimney without protruding inwards the use of flexible metal pipes to connect the appliance to the chimney is not allowed NY 54 d T i Chimney Z LA y 2 y 2 Incorrect FL lid 4 7 Correct lt Ko y y Y ae z m j ES Lj OK Lj OK ENGLISH 15 OExtraflame counter slope sections are not allowed the smoke ducts must have along their entire length a diameter that is no less than that of the attachment ofthe appliance exhaust pipe any section changes are allowed only on the inlet to the chimney they must be installed so as to limit the formation of condensation and prevent their release from the joints they must be positioned at a distance no less than that indicated in the product specifications from combustible materials the smoke channel duct must allow to collect the soot and to be cleaned using a swab and inspected after being disassembled or
50. switch off indicating H OFF and will automatically go back on when the temperature drops below the set point SWITCH OFF Press key 1 for three seconds When the operation has been performed the appliance automatically enters the switch off phase blocking the supply of pellets The flue gas exhaust motor will remain on until the stove temperature has dropped below the factory parameters RE IGNITION The stove can only be re ignited automatically or manually when the cooling cycle conditions and the preset timer have been satisfied ENGLISH 25 OExtraflame ADDITIONAL ROOM THERMOSTAT N B Installation must be performed by an authorised technician There is a possibility to thermostat a room adjacent to the room where the stove is positioned just connect a thermostat following the procedure described in the next step it is recommended to position the optional mechanical thermostat at a height of 1 50 m from the floor Stove functioning with the external thermostat connected in the STBY clamp can be different on the basis of the activation or deactivation of the STBY function The STBY clamp leaves the factory jumpered therefore it is always with closed contact on request ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE When the STBY function is activated the lt LED flashes When the contact or external thermostat is satisfied open contact temperature reached the stove will switch off As soon as the contact
51. the flow sensor IS LS ES IS IS IS 36 ENGLISH OExtraflame DISPLAYS DISPLAY REASON OFF Stove off START The start up phase is in progress PELLET FEEDING Continuous pellet feeding is in progress during the ignition phase IGNITION The ignition phase is in progress START UP The start up phase is in progress WORK The normal work phase is in progress MODULATION The stove is working at minimum EEE Automatic burn pot cleaning is in progress CLEANING x a FINAL CLEANING The final cleaning is in progress STAND BY Stove off waiting for re ignition due to an external thermostat The stove will only re start when the external thermostat makes a request STAND BY A new ignition is attempted when the stove has just been switched off When the stove switches off one must wait for the complete shutdown of the fumes motor then clean the burn pot The stove can only be COOLING re ignited when these operations have been performed HOFF Stove off due to water temperature over set As soon as the water temperature drops below the pre set parameters the stove will switch back on OFF Stove off waiting for re ignition as all the requests have been satisfied STAND BY The stove is cooling after a power cut BLACK OUT Once cooling is completed it will re start au
52. ther details A aux CLAMP B stand by CLAMP LILIANA IDRO DIADEMA IDRO 26 ENGLISH OExtraflame MENU STRUCTURE GO BACK EXIT 2 PARAMETER SCROLLING NEXT 2 PREVIOUS 3 AGE MODIFY SETTINGS DATA INCREASE 4 DECREASE 5 6 CONFIRM ACCESS MENU TEXT VALUE FUNCTION SET POWER SET TEMPERATURE SET ADJUSTMENTS STATUS SET CHRONO LANGUAGE DISPLAY POWER SET H20 BURN POT CLEANING 01 05 65 80 C 0 50 Selecting the power Selection of the boiler temperature set point Burn pot automatic cleaning frequency adjustment STAND BY OFF ON Activation or deactivation of the stand by function ENABLE CHRONO OFF ON Activation deactivation of the weekly programmer PELLETS STOVE STATUS DAY 30 20 MON SUN Selecting the percentage of pellet feed References reserved to the technician Setting the day of the week HOURS 00 24 Adjustment of the hour MINUTES 00 59 Adjustment of the minutes DATE 1 31 Adjustment of the date MONTH 1 12 Adjustment of the month YEAR ENABLE CHRONO 00 99 OFF Adjustment of the year Activation deactivation of the weekly programmer START PRG1 OFF 00 00 Time 1 ignition
53. through inspection openings when not accessible from inside the appliance ADDITIONAL REQUIREMENTS FOR APPLIANCES FITTED WITH AN ELECTRIC FAN FOR FUMES EXPULSION For the heat generator appliances equipped with electric fan for expelling fumes the instructions below must be followed The horizontal sections must have a minimum upward slope of 396 Thelength of the horizontal section must be minimal and in any case no longer than 3 metres The number of direction changes including the one due to the use of the T element must not be more than 4 v EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Installation with internal flue Insulated flue Installation with internal external flue Protection from rain and wind Condensation proof T fitting with PIT inspection plug Protection from rain and wind In pl condensation proof T fitting with inspection Insulated flue sulated ug C IT IS NOT RECOMMENDED TO INSTALL A 90 BEND AS THE FIRST INITIAL PART SINCE THE ASH WOULD BLOCK THE PASSAGE OF THE FUMES IN A SHORT TIME CAUSING PROBLEMS TO THE GENERATOR DRAUGHT Ash deposited in the 90 bend Ash deposited in the 90 bend 16 EN
54. tomatically ANTI FREEZE The anti freeze function is in progress as the 20 t is below the factory set threshold the pump is active until the water reaches the pre set factory parameter 2 C ANTILOCK The pump antilock function is in progress only if the stove has been in an OFF state for at least 96 hours the pump is activated for the time pre set by the manufacturer in order to prevent it from blocking AUTO BLOW The automatic blow is active ENGLISH 37 OExtraflame ALARMS DISPLAY EXPLANATION SOLUTION ASPIRATION FAULT Indicates the presence of an alarm Fumes motor fault On indicates the presence of an alarm Flashing indicates the deactivation of the depression sensor The alarm can be reset by pressing key 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displayed Contact after sales centre FUMES PROBE Fumes probe failure Contact after sales centre HOT FUMES High flue gas temperature Check pellet feed see Pellet feed adjustment If the problem cannot be solved contact an authorised technician CLEAN CHECK UP 1 2 1 IN START UP STAGE 2 IN OPERATING STAGE The door is not closed correctly The ash drawer is not closed correctly The combustion chamber is dirty The flue exhaust pipe is blocked Check hermetic door closure Check hermetic closure of the ash drawer
55. uum cleaner MONTHLY Cleaning the deflector The fumes deflector located in the upper part of the combustion chamber must be removed on a monthly basis see figure to the side To remove it simply pull out the central fumes deflector as if it were a drawer 34 ENGLISH OExtraflame i COMPLETELY CLEAR TO ENSURE PROPER COMBUSTION SEE CHAPTER CLEAN CHECK UP ALARM 1 2 SHOULD THE ALARM CLEAN CHECK UP BE TRIGGERED MAKE SURE THAT THE BOTTOM OF THE BURN POT IS FREE FROM RESIDUES OR SCALING THE HOLES ON THE SIDE OF THE BURN POT SEE FIGURE TO THE SIDE MUST BE CLEANING UNDER USER S RESPONSIBILITY ONE CAN USE THE PELLET FEED ADJUSTMENT FUNCTION TO ADJUST THE COMBUSTION ACCORDING TO THE DESCRIBED REQUIREMENTS IF THE ALARM PERSISTS AND THE ABOVE LISTED CONDITIONS HAVE BEEN CHECKED CONTACT THE QUALIFIED AFTER SALES ASSISTANCE CENTRE BURN POT HOLES ALWAYS FOLLOW THE INSTRUCTIONS IN MAXIMUM SAFETY CONDITIONS e WITHTHE STOVE FULLY COOLED DOWN SWITCHED OFF AND DISCONNECTED FROM THE MAINS ELECTRICITY so C e IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY QUALIFIED PERSON SO AS TO AVOID ALL RISKS e FAILURE TO
56. verification of the suitability of the installation site verification of the suitability of the fumes exhaust system verification of the suitability of the outside air inlets 2 Installation implementation of ventilation and connection to the outer air inlets implementation and connection to the fumes exhaust system assembly and installation electric and hydraulic connections installation of insulation ignition and operation test installation of finishings and coverings 9 9 9 3 Issue of complementary documentation 4 Inspection and maintenance Other actions may be required in relation to specific requests of the competent authority PRELIMINARY ACTIVITIES GENERAL Verification of compatibility of the system of any restrictions required by local administrative regulations special or conventional requirements resulting from condominium regulations constraints laws or administration deeds must precede any other assembly or installation operation One must especially verify the suitability ofthe installation premises of the appliances already installed in the installation premises and in the adjacent and adjoining premises also powered by different fuels with particular reference to non compliant installations ofthefumes exhaust system oftheoutside air inlets SUITABILITY OF THE FUMES EXHAUST SYSTEM Installation must be preceded by a compatibility test between the appliance a