ZONEVU ZVS-SSI-48 INSTALLATION MANUAL
Contents
1. document for list of supported features amp details of each protocol Options ZoneVu Pelco P Pelco D Sensormatic Panasonic Forward Vision Molynx Synectics Plettac 360 Vision Diamond VST and TIB Baud Rate Set to match the speed of the camera Options 1200 2400 4800 9600 19200 38400 Mode Set to match the mode of the camera and the connection type see Connections section Options Simplex Half duplex Full duplex Parity Set to match the parity and bit format of the camera Options N81 E71 O71 E81 081 N72 E72 E82 N82 O72 ZVS SSI 48 INSTALLATION MANUAL DOCX Enables x Address Load Back cm 1 Site 0 Select a x Config Version ZoneVu Port Peripheral Port Enables Cameras Available Options Enabled Options Extended Address Range Pelco Single Speed Lens Enable 9 Add gt Enable 10 tdo lt Remove gt Zonevu lt ZoneVu Enables allow the behaviour of the ZVS SSI 48 to be fine tuned Select an option from the Available Options list and click Add to enable it Extended Addressing Select the full range of camera addresses possible under the current Peripheral protocol Deselecting this option will enforce a smaller camera range on some protocols e Pelco P Extended Range 255 Normal range 32 e Molynx Extended Range 512 Normal range 256 e VST Extended Range 128 Normal range 16 Pelco Single Speed Lens Di
2. in fact which is why we place such a high precedence on providing it For all matters relating to support go to our website to find the information you require Please visit http www meyertech co uk support html MEYERTECH LIMITED Zebra Court White Moss View Greenside Way Manchester M24 1UN Tel 44 0 161 643 7956 Fax 44 0 161 643 3992 Email sales meyertech co uk http www meyertech co uk ZVS SSI 48 INSTALLATION MANUAL DOCX Warranty Please refer to Meyertech Limited Terms amp Conditions of Sale of Goods amp Services for interpretation 1 If the Buyer establishes to the Seller s reasonable satisfaction that there is a defect in the materials or workmanship of the Goods manufactured then the Seller shall at its option at its sole discretion and within a reasonable time a arrange for the repair or making good such defect or failure in such Goods free of charge to the Buyer including all costs of transportation of any Goods or materials to and from the Buyer for that purpose b replace such Goods with Goods which are in all respects in accordance with the Contract or subject in every case to the remaining provisions of this Condition 1 provided that the liability of the Seller under this Condition 1 shall in no event exceed the purchase price of such Goods and performance of anyone of the above options shall constitute an entire discharge of the Seller s liability under this warranty 2 Conditio
3. should be fitted across both pins if required TERM The Termination link should be fitted as required by the installation according to the following table TERM ZoneVu Usage J2 Comms Fitted 1200hm ZVS SSI 48 is on the Termination end of line No All other installations Not fitted Termination PROG The Programming link serves several purposes during installation amp testing It is recommended that during normal operation the link is left not fitted to avoid inadvertent changes to the configuration PROG J1 Mode Usage E Both remote 4 local oe Hd to died programming are p p enabled Fitted during Teer made Test message are operation transmitted Not fitted Normal Normal operation Details of the test modes are included in the Reference section at the end of this manual ZVS SSI 48 INSTALLATION MANUAL DOCX Local Programming Selection of the Camera protocol only is provided for by using the PROG jumper without the need for a configuration program Procedure Step Action Notes 1 Power off the ZVS SSI 48 2 Fit the PROG Link CPU LED flashes rapidly Rx Error LED flashes protocol code e N short flashes then 2 sec gap e N Protocol number Min Ye Second 3 Power up Remove PROG link Re fit PROG link Protocol code changes to indicate next protocol Repeat until correct protocol indicated Power off amp remove PROG link
4. the Seller pursuant to the Contract 12 The Seller warrants that it will use reasonable skill and care in providing the Services to the buyer Issue 2
5. JES ee ee ne a ee ee eee 15 DEEL esti eee nee eee eee 15 DTU VAG tir 16 PROTUINTIS Proc dure it A AAA AS 16 pe toy eee ee E E eer enn ete Pe RUE Sane meen APE eae PHAM Eee PERSE eT een ee Peete ene ee eee eee ee ee 17 SUPPONE nae E ee ees 18 A 19 ZVS SSI 48 INSTALLATION MANUAL DOCX Introduction What is a ZVS SSI 48 The ZVS SSI 48 is a multi protocol serial telemetry converter It allows different types of cameras amp receivers to be controlled from a ZoneVu system Meyertech offers a full range of telemetry converters as well as telemetry protocols embedded in system controllers The ZVS SSI 48 is particularly suited to camera end installations and is often used in combination with video encoders to extend their protocol capabilities Another common usage is where a single ZoneVu telemetry line must be split and converted into different protocols in the field For further details or to discuss the suitability for your particular system design please contact Meyertech Sales office The information in this manual is believed to be accurate and reliable However Meyertech Limited assumes no responsibility or liability for its use or for any infringement of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or other rights of Meyertech All specifications are subject to change without prior notice MEYERTECH UMITED are committed to conti
6. Refer to protocol list below N OO oO A Protocol List Nantel Protocol Name Defaut Bane 1 ZoneVu 9600 8N1 2 Pelco D 9600 8N1 3 Pelco P 9600 8N1 4 Sensormatic 4800 8N1 5 Panasonic 19200 8N1 6 Forward Vision 9600 O81 7 Molynx 9600 E81 8 Synectics 38400 N81 9 Plettac 9600 E81 10 360 Vision 9600 N81 11 Diamond 9600 E81 12 VST 9600 N81 18 TIB Tyco 9600 E72 ZVS SSI 48 INSTALLATION MANUAL DOCX A et For selection of all other settings including Baud rate mode amp camera ranges programming must be carried out using the Mpower configuration tool Please refer to the Remote Programming section ZVS SSI 48 INSTALLATION MANUAL DOCX Remote Programming Full programming of the ZVS SSI 48 is only possible using the Mpower configuration tool Remote Programming is achievable with or without the PROG link fitted however this may need to be fitted before power up to ensure the ZoneVu port is configured at 9600 baud Full Duplex Default Connections Direct Connection Connect to the ZoneVu Comms connector directly using a RS422 converter to your PC laptop e Full Duplex RS422 is required In System programming Alternatively the ZoneVu port may be connected to the ZVR port of a site controller Programming is then possible from one of the RS232 ports on the controller e Full Duplex RS422 is required e Correct programming of the controll
7. ZVS SSI 48 INSTALLATION MANUAL DOCX MEYERTECH SECURITY with VISION MEYERTECH UMITED Zebra Court White Moss View Greenside Way Manchester M24 1UN Tel 44 0 161 643 7956 Fax 44 0 161 643 3992 Email tech support meyertech co uk http www meyertech co uk ZONEVU ZVS SSI 48 INSTALLATION MANUAL Issue 2 Firmware v1 3 1 0 ZVS SSI 48 INSTALLATION MANUAL DOCX Contents AS 2 kalidoro Bc 6 p Maea tem fete neem E EEAS E en ne 3 Whatis 2 MAA 3 MUI Uo teats dee cee its eects Pend AA 4 OO VU COMMS cirio 4 sio ee me CCE tee Cae eee en ere ene cae ea eee ere 4 Beg eee ee eee PAP o ee ee ere ee eee 4 Jumper Settings 2c caseereratissaccedteneiestesoetuadtauptendeseelwebisanleabeNedeetivanteedudteleetbeantucsaNtetsedeneavedusurnsdtenceueet 5 TERM PP O O O O PERO cae OO PO ORO E OE POTO sare O 5 O O 5 EScalrioO AMI tin pita vaa 6 A E E A E E 6 so A 6 R mote Programming cesiones io doo ica 8 COMNMBCION Srs it A E A A A A A sd 8 Direct CONTEO corset caca 8 In System programmiga rer reer ee rer sree teres Per es EEEa eA ec meer rr ee E EAEE terres sree arr 8 NOW A o ecco Enana Nae EnaA Ee eaan ai 9 Accessing the configuration esc oce soi cocccsesinsacosed ates pesiseensnaacosec ore ceenvensadsecoesceewensseeeadoucotecdemmeeraaties 9 co A 10 ooo 11 Peripheral al eee nm eerie pre eer er net rr er rere pene ero eer een Oa SENEE peer err erm eee 12 A nn 13 o AOS nn ee eee ecco 14 so te ecules a a actrees tee Weta 15 HED GO
8. ack to our Service Centre in Scunthorpe Use a reputable carrier as again Meyertech cannot accept liability for loss of goods in transit 5 On receiving the ZVS SSI our staff will after initial examination advise of the course of action we intend to take a Repair the ZVS SSI under warranty The ZVS SSI will be repaired and returned to you free of charge b Replace the ZVS SSI under warranty The ZVS SSI will be repaired and returned to you free of charge c Repair the ZVS SSI at a quoted cost An official purchase order to cover the cost and return of the product will be required prior to commencement of repair d Advise you that the ZVS SSI is not repairable You can then decide to have the product returned to you at the standard delivery charge or we can dispose of the product free of charge Meyertech Service Centre Unit 18 Queensway Business Centre Dunlop Way Scunthorpe DN16 3RN Tel 01724 278833 Fax 01724 289099 ZVS SSI 48 INSTALLATION MANUAL DOCX Disposal There are no additional requirements beyond safe working practice in the decommissioning of the Meyertech ZVS SSI However the ZVS SSI contains printed circuit boards populated with electronic components The whole unit must be returned to Meyertech Service Centre for final disposal Please follow the normal returns procedure ZVS SSI 48 INSTALLATION MANUAL DOCX Support At Meyertech our staff understand quality support is important to you vital
9. d Rx Error LED stays on if message not received 5 Half Duplex Loop back Test message send alternately between ZoneVu amp Peripheral ports Note The length of the time a camera moves for in response to a single command will vary between different camera types A ZoneVu camera will typically move for 1 second during this test ZVS SSI 48 INSTALLATION MANUAL DOCX Maintenance The ZVS SSI requires no Planned Preventive Maintenance periods PPM s as it is mainly solid state in design The ZVS SSI contains no serviceable parts and should be returned to our Service Centre in Scunthorpe for repair or replacement under warranty Any repairs attempted repairs or replaced components not carried out by the Meyertech Service Centre will void all Meyertech warranties and liabilities If your ZVS SSI has to be returned to our Service Centre please follow the returns procedure below otherwise delays may be incurred in returning or replacing the ZVS SSI Returns Procedure Prior to returning your ZVS SSI 1 Contact our Service Centre by phone on 0161 643 7956 or by email tech support meyertech co uk for a Goods Return Number 2 The GRN will be logged by our staff along with the reported problem 3 Pack the ZVS SSI into the original packing it was delivered in Failure to do so means the unit may incur further damage in transit which Meyertech cannot be responsible for 4 Organise delivery of the ZVS SSI b
10. e ZVS SSI 48 and displays the software version information If Response confirmed is not seen in the Status please check the connection and use the Select button to retry ZVS SSI 48 Configuration es Address Camera 0 Site 0 Select Back Contig Version Zonevu Port Peripheral Port Enables Cameras Config Structure fi stored jo Software Version 1 0 0 0 Status Response confirmed ZVS SSI 48 INSTALLATION MANUAL DOCX ZoneVu Port Config Version ZoneVu Port Peripheral Port Enables Cameras Baud Rate 9600 v Mode F ull duplex v Parity N81 y gt Zonevu ili lt ZoneVu ZoneVu Port Default Configuration Baud Rate Set to match the speed of the ZoneVu site controller or other Telemetry source Options 1200 2400 4800 9600 19200 38400 Mode Set to match the mode of the Telemetry source and the connection type see Connections section Options Simplex Half duplex Full duplex Parity Set to match the parity and bit format of the Telemetry source Options N81 E71 O71 E81 081 Page 11 ZVS SSI 48 INSTALLATION MANUAL DOCX Peripheral Port Config Version ZoneYu Port Peripheral Port Enables Cameras Protocol Pelco D v Baud Rate 3600 v Mode Simplex X Parity N8l y gt Zonevu il lt ZoneVu Peripheral Port Default Configuration Protocol Select the Protocol type of the camera See Supported Cameras
11. er is required to route telemetry to the appropriate ZVR port ZVS SSI 48 INSTALLATION MANUAL DOCX Mpower Installation amp general operation of Mpower is covered in a separate manual installed with the application This section covers details of the ZVS SSI 48 settings and their usage Accessing the configuration From the main Mpower menu select Configuration Peripherals ZVS SSI 48 Meyertech mPower File Setup Workstation Configuration Diagnostics Other Dialup Keyboard Matrix Peripherals ZVS MSL Receiver ZVS MSI IP Site Controller ZVS MSI 23 3rd Party ZVS MSI 48 ZVS SSI 48 ZVS ROM 16 The Select Unit Address dialogue will be displayed Entering a Site number and Camera number Unit address allows a ZVS SSI 48 to be selected during in system programming la Select Unit Address ee Unit Address H 0 Cancel Site Number Monitor 1 le Mevertech mPower data e Site Number 0 Unit Number 0 can be used with a direct connection regardless of programming e The ZVS SSI 48 will respond to any Camera number Unit address which is enabled on it By default all Cameras up to 1024 are enabled e lf connected through a site controller different camera numbers will be directed to different ZVR ports e Monitor number is not used ZVS SSI 48 INSTALLATION MANUAL DOCX Config Version This screen confirms connection to th
12. hall be redelivered to the Buyer free of charge to the original point of delivery but otherwise in accordance with and subject to these Conditions 5 Alternatively to Condition 1 the Seller shall be entitled at its absolute discretion on return of the defective Goods to the Seller at the Seller s request to refund the price of the defective Goods in the event that such price shall already have been paid by the Buyer to the Seller or if such price has not been paid to relieve the Buyer of all obligation to pay the sum by the issue of a credit note in favour of the Buyer in the amount of such price 6 In respect of all Goods supplied to the Seller by a Third Party Supplier the Seller will on request pass on to the Buyer in so far as reasonably possible the benefit of any warranty given to the Seller by such Third Party Supplier and will on request supply to the Buyer details of the terms and conditions of such warranty and copies of any relevant product information sheets technical data sheets or product leaflets issued by such Third Party Supplier and the Buyer shall be solely responsible to the entire exclusion of the Seller for complying with the same 7 For the purposes of Condition 1 references to Goods shall be deemed to exclude software 8 The Buyer acknowledges that software in general is not error free and agrees that the existence of such errors in the Software Programs shall not constitute a breach of this Contract 9 Inthe even
13. ll also be polled for Alarm and or status information dependent on protocol ZVS SSI 48 INSTALLATION MANUAL DOCX Reference LED Codes Status CPU LED Rx Error LED Notes state state Normal 1Hz Flash Off Power up with PROG link not fitted Self test mode 1Hz Flash 1Hz Flash Fit PROG whilst in Normal OK alternate with state CPU Self test mode 1Hz Flash On Fail state latched until PROG FAIL link removed Programming 10Hz Flash Indicates N short flashes followed by 2 mode Peripheral seconds off protocol N Protocol number Test Modes Test modes are provided to assist the engineer in determining if the setup amp connection to the camera is correct and for diagnosing problems To enter test mode power on the converter in normal mode PROG link not fitted then fit the PROG link e Test Mode 1 starts immediately the link is fitted e Removing the Link stops the test e Re fitting the link selects the next test mode 1 gt 2 gt 3 gt 4 gt 5 gt 1 Test Test Detail Result Mode 1 Pan Left Command sent to each enabled Cameras Pan camera in turn 1 per second 2 Pan Right Command sent to each enabled Cameras Pan camera in turn 1 per second 3 Stop Command sent to each enabled Cameras Stop camera in turn 1 per second Test message send alternately between ZoneVu amp Peripheral ports 4 Full Duplex Loop back Rx Error LED stays on if message not receive
14. n 1 shall not apply unless the Buyer a notifies the Seller in writing of the alleged defect within 12 twelve months from delivery or such other period or periods as may be agreed in writing between the Seller and the Buyer and b allows the Seller a reasonable opportunity to inspect the relevant Goods 3 For the avoidance of doubt the Seller shall be under no liability under the warranty in Condition 1 above a where such defects arise from any drawing design or specification supplied by the Buyer or b where such defects arise from fair wear and tear wilful damage or negligence of a party other than the Seller or its employees or authorised personnel abnormal working conditions failure to follow the Seller s instructions whether oral or in writing misuse or alteration or repair of the Goods without the Seller s approval or c where such defects arise in parts materials or equipment which have not been manufactured or designed by the Seller but have been purchased at the Buyer s request by the Seller from the Buyer s designer and manufacturer or from some other third party the Third Party Supplier d if the total price of the Goods has not been paid by the due date for payment e in respect of any type of defect damage or wear specifically excluded by the Seller by notice in writing or f if the Buyer makes any further use of the Goods after giving notice in accordance with Clause 1 4 Any repaired or replaced Goods s
15. nuous product development and therefore reserve the right to change specifications without notice 2014 ALL RIGHTS RESERVED ZVS SSI 48 INSTALLATION MANUAL DOCX Connections ZoneVu Comms ZoneVu comms should be connected to a source of camera control telemetry such as a ZSC 1000plus ZVR port It can operate in Simplex mode receive only or Duplex mode if alarm or configuration information is required from the camera Supported modes RS 422 and RS 485 only Pin number Simplex Mode Half Duplex Full Duplex 1 Rx Rx and Tx Rx 2 Rx Rx and Tx Rx 3 OV OV OV 4 n c n c Tx 5 n c n c TX 6 Earth Earth Earth Peripheral Comms Peripheral comms should be connected to a camera or Telemetry receiver It can operate in Simplex mode transmit only or Duplex mode if alarm or configuration information is required from the camera Supported modes RS 422 and RS 485 only Pin number Simplex Mode Half Duplex Full Duplex 1 n c Rx and Tx Rx 2 n c Rx and Tx Rx 3 OV OV OV 4 Tx n c Tx 5 TX n c TX 6 Earth Earth Earth DC In Power to the converter is provided by a 12V DC mains input power cube supplied Pin number 1 12V DC 2 OV ZVS SSI 48 INSTALLATION MANUAL DOCX Jumper Seitings Between the DC In and ZoneVu Comms connectors are two 2 pin jumpers Links are supplied fitted to one pin only for retention and
16. sables variable speed lens control for Pelco Cameras Recommended for Pelco Spectra dome cameras Enable 3 to Enable 20 For future use ZVS SSI 48 INSTALLATION MANUAL DOCX Cameras Config Version ZoneVu Port Peripheral Pott Enables Cameras Available Cameras Enabled Cameras un polled Enabled Cameras polled Camera 2 NM Camera 3 gt Camera 4 Camera 5 Camera 6 Camera 7 Camera 8 Camera 9 Camera 10 3 Camera 11 _ Add gt Camera 12 Camera 13 lt Remove Camera 14 Camera 15 Camera 16 Camera 17 Camera 18 Camera 19 Add gt lt Remove Camera 20 Camera 21 gt Zonevu Camera 22 Camera 23 Camera 24 v lt ZoneVu Cameras Default Configuration The Cameras page allows the camera range of the ZVS SSI 48 to be specified and also for certain cameras to be selected for alarm status polling Select one or more Cameras in any list and select Add or Remove to move them between the three lists To select multiple cameras hold the Ctrl key whilst selecting press the shift key to select a range or drag the mouse over a range of cameras Available Cameras Cameras in this list are available but not enabled on this ZVS SSI 48 Enabled Cameras un polled Cameras in this list are enabled for control through this ZVS SSI 48 This is the default for all cameras 1 to 1024 Enabled Cameras polled Cameras in this list are enabled for control and wi
17. t that the Buyer discovers a material error which results in the Programmed Products not performing substantially in accordance with the Functional Specification or the Licensed Programs not performing substantially in accordance with the relevant Program Documentation and notifies the Seller of the error within 90 days from the date of the Seller making available the respective software to the Buyer the warranty period the Seller shall at its sole option either refund the price which the Buyer has paid to the Seller or if such price has not been paid relieve the Buyer of all obligations to pay the sum in respect of the respective software or use all reasonable endeavours to correct by patch or new release at its option that part of the software which does not so comply provided that such non compliance has not been caused by any modification variation or addition to the software not performed by the Seller or caused by its incorrect use abuse or corruption of the software by use of the software with other software or on equipment with which it is incompatible 10 To the extent permitted by English law the Seller disclaims all other warranties with respect to the software which it provides pursuant to the Contract either express or implied including but not limited to any implied warranties of satisfactory quality or fitness for any particular purpose 11 The Buyer is solely responsible for various scanning the software that it receives from