        SUNNY MINI CENTRAL 4600A/5000A/6000A
         Contents
1.                                                                                                                                                                                                                       Object  Description  Screw terminals for      wire bridge          Screw terminals for connecting the cables       Jumper slot  Flat male tab for grounding the cable shield          Silicone tube cable route                         gt     Cable glands             42 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection    Procedure  1  Open the inverter as described in section 7 2  Opening the Inverter   page 55      2  Insert the cable into each inverter     Use 1 of the 2 enclosure openings  F  on the right hand side     DANGER   Danger to life through high voltage if there is a fault with the       SMA Power Balancer cable       Sheath the positive and negative cable conductors in each inverter using the  enclosed silicone tube            the silicone tube to the required length       The silicone tube must completely cover the cable inside the inverter enclosure        Draw the cable along the cable route  E  as far as the terminal block        Ground the cable shield in each inverter at the PE terminal  0      Sheath the positive and negative cable conductors in each inverter with bootlace ferrules     O U o       Connect the positive and negative pole to the  corresponding screw terminals                     s            
2.                               7  In order to connect      3 inverters together  connect      positive and negative conductors from  the 2 other inverters to the terminal block of the middle inverter                                         Inverter 1 Inverter 2 Inverter 3        A B                     Twisted cable Twisted cable                                 pe  max  300 m max  300 m    The cable length between 2 inverters may not exceed 300 m     Installation Manual SMC46 60A IA IEN 120471 43    Electrical Connection    8     Only in the middle inverter  the one with 2 wires  for each terminal   insert one of the provided  jumpers into the lowest of the slots as depicted on  the right     Do not plug the jumpers in the bottom slot of the  2 other inverters     or    Bridge the  A  and  B  screw terminals on the  middle inverter with a wire bridge     Do not bridge the  A  and  B  screw terminals in  the 2 other inverters     Measure the resistance between the terminal  block s positive and negative poles in the middle  inverter       IF the resistance is approximately 27 8          370       the SMA Power Balancer has been  connected correctly  Otherwise  check the  cabling     SMA Solar Technology AG                                            o                                                           10  Close all inverters as described in section 7 3  Closing the Inverter   page 58         i    44    Connection with a Sunny Mini Central 9000TL  10000TL or 11000TL    In 
3.            The maximum open circuit voltage that can occur with   10  C cell temperature may not exceed the maximum input voltage                                               AC Output   Rated power at 230 V  50 Hz 6 000W  Maximum apparent AC power 6 000 VA  Rated grid voltage 230 V  Nominal AC voltage 220 V 230 V 240 V  AC voltage range 160 V     265 V  Nominal AC current at 230 V 26A  Nominal AC current at 240 V 25A  Maximum output current 26     Total harmonic factor of the output current with  lt  3    AC voltage  lt  2  and   AC power  gt  50  of rated power   Rated power frequency 50 Hz   AC power frequency 50 Hz 60 Hz  Operating range at AC power frequency 50 Hz 44 Hz    55 Hz  Operating range at AC power frequency 60 Hz 54 Hz    65 Hz  Displacement power factor  adjustable  0 8 verexcited     0 Bunderexcited       Power factor at nominal AC power              Feed in phases            Connection phases            Overvoltage category according to    IEC 60664 1                  Applies to SMC 6000A 11     Applies to SMC 6000A SMC 6000A IT    Installation Manual    SMC46 60A A IEN 120471 81          Technical Data SMA Solar Technology AG  Efficiency   Maximum efficiency  Nmax 96 1    European weighted efficiency  ney 95 3                 11 2 General Data                                        Width x height x depth with 468 mm x 613 mm x 242 mm  Electronic Solar Switch   Weight 63 kg   Length x width x height of packaging 396 mm x 803 mm x 596 mm  Transport weight 68
4.         PV Inverter    SUNNY MINI CENTRAL 4600A   5000A   6000A    Installation Manual       SMC46 60AIAIEN120471   IMESMC50A_60A   Version 7 1          SMA Solar Technology AG Table of Contents    Table of Contents    1   1 1  1 2  1 3  1 4    2  2 1  2 2    2 3  2 3 1  2 3 2    3 1  3 2    4 1  4 2  4 3    5 1   5 1 1  5 1 2  5 2   5 2 1  5 2 2  5 2 3    Information on this Manual                o o o ooooo    7       a ante RTT      7  Target Group eee even                 ee ee See ee bees 7  Additional Information    scura Awe od bd dr 7  Symbols Used setesi sa aE      8  E 9  Intended                                                9  Safety                                                           10  Explanation of Symbols                                11  Symbols on                       ln ed to 11  Symbols on the Type Label              rra pee thi 12  UNPAID EU UE o E ES S 13  Scope                                                     13  Identifying the Inverter                                 14  Mount                                                        E AA ROS EROR 15                 E          an awe      15  Selecting the Mounting Location                          15  Mounting the Inverter with the Wall Mounting Bracket        17  Electrical Connection                               20  Overview of the Connection Area                        20  O A                  ER        ERSTE a tg 20  Interior  Vi WAR O ARENIS eat d 21  Connection to the Power Distribu
5.      10  Secure the enclosure lid with all screws and the  corresponding conical spring washers     Tighten the screws with 6 Nm torque in the order  shown in the figure on the right  The toothing of the  conical spring washers must point toward the  enclosure lid     The scope of delivery of the inverter includes  another spare screw and conical spring washer        DANGER     Danger to life due to enclosure lid carrying voltage        The grounding of the enclosure lid is ensured by the conical spring washers       Attach the conical spring washers for all 6 screws with the toothing facing toward the  enclosure lid     DANGER   Danger to life due to high voltages in the inverter               Do not switch on the miniature circuit breaker until the PV array has also been  connected and the inverter is securely closed           The inverter is now connected to the power distribution grid  AC      26 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection    5 2 3 Additional Grounding of the Enclosure    IF the installation requires  you can use the ground terminal to connect a second protective conductor  or as equipotential bonding     Procedure          1  Insert the stripped grounding cable  D  under the  clamping bracket  C   max  cross section 16 mm   or with bootlace ferrule max  10     2               2  Screw the clamping bracket tight with screw   A  and conical spring washer             The toothing of the conical spring washer 
6.     10 4 Disposing of the Inverter    Dispose of the inverter at the end of its service life in accordance with the current locally applicable  disposal regulations for electronic waste  Alternatively  send it back to SMA Solar Technology AG  with shipping paid by sender  and labeled  ZUR ENTSORGUNG    for disposal      contact see Page 86      76 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Technical Data    11 Technical Data  11 1 DC AC    11 1 1 Sunny Mini Central 4600A                                  DC Input   Maximum DC power at cos      1 5250W  Maximum input voltage   600 V  MPP voltage range 246       480 V  Rated input voltage 246 V  Minimum input voltage 211V  Start input voltage 300 V  Maximum input current 26A  Maximum input current per string 26A  Number of independent MPP inputs 1  Strings per MPP input 4                  The maximum open circuit voltage that can occur with   10  C cell temperature may not exceed the maximum input voltage     Installation Manual SMC46 60A IA IEN 120471 77                                                 Technical Data SMA Solar Technology AG  AC Output   Rated power at 230 V  50 Hz 4 600 W  Maximum apparent AC power  5 000 VA   Rated grid voltage 230 V   Nominal AC voltage 220 V 230 V 240 V   AC voltage range 160 V     265 V  Nominal AC current at 220 V 20 9 A   Nominal AC current at 230 V 20 0 A   Nominal AC current at 240 V 19 16 A   Maximum output current 26A   Total harmonic factor of the output cu
7.   The fan cables are long enough that you can lift the fans far enough out to disconnect the  internal plug in the inverter   Remove the fan    9  Clean the fan with a soft brush  a paint brush  or a damp cloth          NOTICE   o b Damage to the fan through use of compressed air          Do not use compressed air to clean the fan  This can damage the fan           10  After cleaning  reassemble everything in reverse order          The fans are cleaned     11  Checkthe functioning of the fans as described in the following section     SMC46 60A IA IEN 120471 61    Installation Manual    Maintenance and Cleaning SMA Solar Technology AG    8 2 2 Checking the Fans    You can check that the fans are working in 2 ways     Set the  Fan Test  parameter to  1  in the installer mode using Sunny Data Control   Sunny Explorer or Sunny WebBox     or    Plug the provided jumper into the system control board     Setting Parameters         Request the installer password             SMA Service Line  contact  see          86      2  Set the  Fan Test  parameter to  1  in the installer mode   3  Check the fans  air flow   The inverter takes cooling air in from underneath and then blows it back out on the upper sides   Listen for any unusual noise  which could indicate incorrect installation or that the fans are faulty   4  After checking the fans  set the  Fan Test  parameter back to  O       The test of the fans has been completed   Plugging the Jumper    The inverter recognizes the jumper on
8.   gt        Varistors             22    SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection    5 2 Connection to the Power Distribution Grid  AC     5 2 1 Conditions for the AC Connection         e   Connection requirements of the grid operator    Always observe the connection requirements of your grid operator     Cable Design    Use  Sunny Design  version 2 0 or higher for the dimensioning of the conductor cross sectional areas   see  Sunny Design  program at www SMA de en         i      Halving the cable losses    If 3 inverters with symmetrical feed in are combined to form a three phase system  the  neutral conductor is not subjected to any load  and the cable losses are halved   Thus  the maximum possible cable length is doubled     Cable Requirements        WwW V                                    C  Position Designation Value  A External diameter 12 mm     25 mm  B Conductor cross section 6 mm      16 mm   C Length of insulation to be stripped off   approx  16 mm             Installation Manual SMC46 60A IA IEN 120471 23    Electrical Connection SMA Solar Technology AG    Load Disconnection Unit   You must install a separate miniature circuit breaker for each inverter in order to ensure that the  inverter can be securely disconnected under load  The maximum permissible fuse protection can be  found in section 11  Technical Data   page 77      Detailed information and examples for the rating of a miniature circuit breaker can be 
9.  5 1 2 Interior View    The following figure shows the various components and connection areas of the open inverter       gt                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   Installation Manual SMC46 60A A 1EN 12047 1 21    Electrical Connection SMA Solar Technology AG       O       o               Description    Connection area and slots for communication       Display       Jumper slot for the fan test       LEDs for displaying the operating states       Jumper slot for SMA Power Balancer       Terminals for SMA Power Balancer       Flat male tab for grounding the cable shield when connecting the SMA Power Balancer       Additional terminal for grounding       Terminals for AC cables       Cable glands for the SMA Power Balancer       Cable gland for AC cable       Cable glands for communication       Screwing device for shield connection terminal for communication cable       DC connector       Connection jack for Electronic Solar Switch  ESS            0 2                             
10.  Calibration value  mE            Reaction time                     Current power frequency  ESE TN  CASN FOLS       Installation Manual SMC46 60A IA IEN 120471 53    Commissioning SMA Solar Technology AG    Minimum Frequency  In the last step  the inverter tests the minim  m frequency    Autotest  During the test sequence  the frequency limit applied is     Eee miso A  FAH  shown in the display of the inverter  Fac nins 49 1 BHz  The frequency limit is increased successively until the  disconnection threshold is reached and the inverter disconnects from the power distribution grid     Once the inverter has disconnected from the power distribution grid  the display successively shows  the following values one after the other        e Disconnection value          Calibration value             Reaction time            Current power frequency                 Once the inverter has carried out the 4 tests  it switches to  MPP Operation  MPP   mode  The original  calibration values are then reset and the inverter automatically connects to the power distribution grid   If you would like to carry out the test again  you must disconnect the inverter  i e  disconnect it on the  AC and DC sides and then later recommission it  You can then restart the self test as described in  section 6 3 1  Starting the Self Test by Tapping   page 50   The inverter starts again the test sequence  as described in section 6 3 2  Completion of the Selftest   page 51      54 SMC46 60A IA IEN 120471 Install
11.  kg   Climatic category according to IEC 60721 2 1 AKAH   Operating temperature range  25  C      60  C  Maximum permissible value for relative humidity  100   non condensing   Maximum operating altitude above MSL 2 000 m   Noise emission  typical   lt  42 dB A    Power loss in night operation 0 25 W   Topology LF transformer  Cooling concept OptiCool       Fan connection    designed for safe disconnection in accordance    with DIN EN 50178 1998 04       Electronics degree of protection according to    IEC 60529    IP65          Protection class according to IEC 62103             11 3 Protective Devices       DC reverse polarity protection    short circuit diode       Inputside disconnection device    Electronic Solar Switch       DC overvoltage protection    thermally monitored varistors       AC short circuit current capability    current control       Grid monitoring    SMA Grid Guard 2 1       Maximum permissible fuse protection    40A       Ground fault monitoring    Insulation monitoring  Rio  gt  1 MQ       Galvanic isolation          available          82 SMC46 60A A IEN 120471    Installation Manual    SMA Solar Technology AG Technical Data    11 4 National Standards                                                                                                          National standard as       E E   0101 2012                    s   3 3  3  Ss Ss 8 8 8 81 8          2 9v                    2 2 8 5 5   VDEO126 1 1 Y Y Y Y Y Y       VDE AR N 4105 Y Y Y          AS 47
12. 1    Commissioning    Undervoltage Test    After the overvoltage test  the inverter performs the  undervoltage test  During the test sequence  the current  calibration value of the voltage limit applied is shown in  the display of the inverter     SMA Solar Technology AG                               mins  iss  Bo       The voltage limit is increased successively until the disconnection threshold is reached and the inverter    disconnects from the power distribution grid     Once the inverter has disconnected from the power distribution grid  the display successively shows    the following values one after the other     e Disconnection value     Calibration value     e Reaction time       Current line voltage     52 SMC46 60AA IEN 120471                di solia      nons BES  SEU          Tempo interusenmo          Tensione di rete  Nal  eff                  Installation Manual    SMA Solar Technology AG Commissioning    Maximum Frequency       In a third step  the inverter tests the maximum frequency   During the test sequence  the frequency limit applied is  shown in the display of the inverter     utotezt    aul    is JHE    Ln           max   The frequency limit is reduced successively until the  disconnection threshold is reached and the inverter disconnects from the power distribution grid     Once the inverter has disconnected from the power distribution grid  the display successively shows  the following values one after the other        e Disconnection value         
13. 2  N      wo         z z         o o     v            v                  2s 25  a  a    5 8   92  5 5   5 5          i   o     E o  2    95         oue  85   85  Ow  E   O n  Tole   T     9         4                uror      AREE       e   og    58 3 mm   J  134 0 mm   134 0 mm v    583 mm         gt   pt  gt    25 0 mm 25 0 mm    Installation Manual SMC46 60A IA IEN 120471 17    Mounting SMA Solar Technology AG    CAUTION    N Risk of injury due to the heavy weight of the inverter     The inverter weighs approx  63 kg        e          the wall mounting bracket with the corresponding mounting material   depending on the surface                    side handles  above and below   or a steel rod  maximum diameter of  30 mm  for transport and mounting   The rod must be pushed through the  enclosure openings                 2  Secure the wall mounting bracket to the wall using  appropriate screws and washers       3  Hang the inverter onto the wall mounting bracket  using the opening for this purpose in the rear of the  enclosure        18 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Mounting    4  Screw the inverter onto the wall mounting bracket    on both sides using the screws  M6x8  provided     Only tighten the screws hand tight     5  Check to ensure that the inverter is securely in  place     6  Close the recessed grips with the fan guards  provided  To help you identify the sides  the fan  guards are marked  rechts right  and  links left  on  th
14. 30 V  50 Hz 5 000 W  Maximum apparent AC power 5 500 VA   Rated grid voltage 230 V   Nominal AC voltage 220 V 230 V 240 V  AC voltage range 160 V     265 V  Nominal AC current at 220 V 22 7 A   Nominal AC current at 230 V 21 7A   Nominal AC current at 240 V 20 8 A   Maximum output current 26A   Total harmonic factor of the output current with  lt  3    AC voltage  lt  2  and   AC power  gt  50  of rated power   Rated power frequency 50 Hz   AC power frequency 50 Hz 60 Hz  Operating range at AC power frequency 50 Hz 44 Hz    55 Hz  Operating range at AC power frequency 60 Hz 54 Hz    65 Hz  Displacement power factor  adjustable        ceca 0  Bunderexciied       Power factor at nominal AC power      1       Feed in phases    1       Connection phases    1       Overvoltage category according to    IEC 60664 1                  Applies to SMC 5000A 11     Applies to SMC 5000A SMC 5000A IT          Efficiency  Maximum efficiency  Nmax 96 1   European weighted efficiency  ney 95 3                 80 SMC46 60A IA EN 120471    Installation Manual    SMA Solar Technology AG    11 1 3 Sunny Mini Central 6000A  DC Input    Technical Data                                        Maximum DC power at cos      1 6 300W  Maximum input voltage   600 V  MPP voltage range 246       480 V  Rated input voltage 246 V  Minimum input voltage 211V  Start input voltage 300 V  Maximum input current 26    Maximum input current per string 26 A  Number of independent MPP inputs 1   Strings per MPP input 4 
15. 77            Y  A       C10 11          Y Y Y       PPDS o O O Y Y Y  gt   gt    GBT19939 2005    O O Y Y Y        VDEO126 1 1  O    O  4 Y  4       UTE C15 712 1          C15 712 1           Y Y Y 7      EDF SEI req    PPC          Y Y Y       SI 4777 O    O Y Y Y       DK5940             Y Y   EN 50438  Y Y Y Y Y Y       RD 1663 2000    O O Y Y Y   e   RD 661 2007          Y Y 7         IEC 61727 PEA    Y Y z Y Y    E   G83 1 1          Y Y Y        G59 2 5 5    E   Y E        EN 50438  Does not apply to all national standard deviations    O In planning   11 5 Climatic Conditions   According to IEC 60721 3 4  Installation Type C  Class 4K4H   Extended temperature range  25        60       Extended air humidity range 0      100    Extended air pressure range 79 5 kPa     106 kPa   According to IEC 60721 3 4  Transport Type E  Class 2K3   Temperature range  25  C      70  C                Installation Manual SMC46 60A IA IEN 120471 83       Technical Data SMA Solar Technology AG  11 6 Features  DC connection SUNCLIX DC connector       AC connection    screw terminal                      Display LC text display  Bluetooth  Wireless Technology optional  RS485  galvanically isolated optional       11 7 Electronic Solar Switch  ESS        Electrical endurance in the event of a short circuit   with a nominal current of 35 A    min  50 switching processes                                                                                           Maximum switching current 35A  Maximu
16. A Solar Technology AG       Result Measure       There is no conductive The respective varistor is defective and must be replaced   connection     Varistor failure is generally due to influences that affect  all varistors similarly  temperature  age  induced  overvoltage   SMA Solar Technology AG recommends  that you replace both varistors    The varistors are specially manufactured for use in the  inverter and are not commercially available  They must  be ordered directly from SMA Solar Technology AG   see section 12  Accessories   page 85                   replace the varistors  proceed to step 3             NOTICE            Destruction of the inverter due to overvoltage             If varistors are missing  the inverter is no longer protected against overvoltages     Replacement varistors should be obtained as soon as possible            not operate the inverter without varistors in PV plants with a high risk of  overvoltages              3  Insert an insertion tool into the openings of the  terminal contacts  1         This releases the terminals     If you do not receive an insertion tool for operating  the terminals with your replacement varistors   contact SMA Solar Technology AG  As an  alternative  the individual terminal contacts can be  operated using a 3 5 mm wide screwdriver   Remove the varistor  2     5  Insert the new varistor  3      The pole with the small loop  crimp  must be fitted  to terminal A when replacing the varistor     6  Close the inverter as de
17. MA Czech com    SMA France S A S   www SMA France com   SMA Hellas AE  www SMA Hellas com   SMA Ib  rica Tecnolog  a Solar  S L   www SMA lberica com   SMA Italia S r l   www SMA ltalia com   SMA Technology Korea Co   Ltd     www SMA Korea com       
18. PROM   The data is not relevant for safe operation   e This fault has no effect on the performance of the inverter   EEPROM dBh EEPROM data is defective  The inverter has switched itself off because the  loss of data has disabled important functions of the inverter   Corrective measures  e Contact the SMA Service Line   EeRestore One of the duplicate records in the EEPROM is defective and has been  reconstructed without loss of data     This error message only serves to inform you and has no effect on  the performance of the inverter   Fac Bfr The power frequency is no longer within the permissible range  EGCSTIE           Srr   Fast  is an internal message that has no meaning for the  user   The inverter disconnects itself from the power distribution grid for  Fastest safety reasons   Corrective measures    Check the grid connection and contact the grid operator if  necessary   e If the power frequency is within the tolerable range  but  Fac Bfr     Fac Srr  or  FacFast  faults are still displayed  contact the  SMA Service Line   K1 Close Error during relay test   K1 Open Corrective measures      Ifthis fault frequently occurs or occurs several times consecutively   contact the SMA Service Line   Imax Overcurrent on the AC side  This message is displayed if the current in the    AC grid is higher than specified           Corrective measures       e Check the plant design and grid conditions           Installation Manual    SMC46 60A A IEN 120471 67    Troubleshooting    SMA 
19. Solar Technology AG                                  Message Description and corrective measure  MSD Fac Internal measurement comparison fault or hardware defect   Corrective measures    Ifthis fault occurs frequently  contact the SMA Service Line   MSD Vac Internal measurement comparison fault or hardware defect   Corrective measures      Ifthis fault occurs frequently  contact the SMA Service line   MSD Timeout Internal measurement comparison fault or hardware defect   Corrective measures    Ifthis fault occurs frequently  contact the SMA Service Line   OFFSET The  OFFSET  operating state is a normal operating state that occurs prior    to grid monitoring  If  OFFSET  is displayed as an error  there is a fault in  the data logging        Corrective measures        Ifthis fault occurs frequently  contact the SMA Service line           PowerBalance    The Sunny Mini Central is part of a three phase system with 2 further  Sunny Mini Central inverters equipped with the SMA Power Balancer for  preventing unbalanced loads  The operating parameter  PowerBalancer   is set to  PhaseGuard  or  FaultGuard         Corrective measures      For detailed descriptions of the operation modes  PhaseGuard   and  FaultGuard   refer to section 5 5  Connection of the SMA  Power Balancer   page 37                     Riso The electrical insulation between the PV plant and ground is defective   The resistance between the DC plus and or DC minus connection and  ground is outside the defined limit r
20. This operating mode allows for the implementation of a three phase grid voltage monitoring       If 1 of the 3 inverters indicates a line voltage fault and stops feeding in   the other 2 inverters also disconnect from the power distribution grid automatically     Grid voltage fault  Grid disconnection  Grid disconnection         Output  O VA      D Output  O VA e  p Output  O VA       f 1 of the 3 inverters indicates a device fault and stops feeding in   the other 2 inverters are not affected and continue to feed in at full power                  C  Vy T    Device fault  No reaction  No reaction       A Output  O VA A    Output  Promax         Output  Promax    Installation Manual SMC46 60A IA IEN 120471 39    Electrical Connection SMA Solar Technology AG      Off  The SMA Power Balancer is deactivated  default setting      Inthe event of a device fault or line voltage fault at an inverter  only this inverter is    disconnected from the power distribution grid and the other two inverters continue to run at  an undiminished power level     ON    aa     Vy    Vy YN    Grid voltage fault No reaction  No reaction       A or device fault        Output  Pac    a    Output                Output                  PowerGuard    This setting can be selected if the entire PV plant only consists of three 3 Sunny Mini Central  inverters and in the event of a malfunction  the unbalanced load should be limited to 4 6 kVA  over a 10 minute average     e   Deviating unbalanced load limit for I
21. ange    Corrective measures  e Check the insulation of the PV plant   e          the PV plant for ground faults as described in section  9 3 1  Checking the PV Array for Ground Faults   page 71    ROM The inverter s firmware is faulty        Corrective measures        Ifthis fault occurs frequently  contact the SMA Service line           Trafo Temp F       Temperatures in the transformer have exceeded the acceptable limit  The  inverter stops feeding the grid until the temperature lies within the  acceptable range           Corrective measures        If this fault occurs frequently  check the heat dissipation           68 SMC46 60A A IEN 120471 Installation Manual                            SMA Solar Technology AG Troubleshooting  Message Description and corrective measure  Trafo Temp W If the transformer reaches an inadmissibly high temperature  the inverter  stops feeding the grid until the transformer has reached an admissible  temperature and the plant can begin feeding the grid again   The  Trafo Temp W  warning is displayed until the device is completely  disconnected   Corrective measures  e          the heat dissipation of the inverter   Shutdown Temporary inverter fault   Corrective measures  e Contact the SMA Service Line   Vac Bfr The line voltage is no longer within the permissible range   Bfr  or  Srr  is     an internal message of no relevance for the user   This fault can be       caused by any of the following conditions     e Power distribution grid disconnec
22. as described in  section 6  Commissioning   page 48    or          64 SMC46 60AA IEN 120471    Installation Manual    SMA Solar Technology AG    9 Troubleshooting    Troubleshooting    If the inverter displays other blink codes or error messages than those described below   contact the SMA Service Line     You will also find a description of display messages during operation  status messages and  measurement channels in the user manual provided     Do not perform any repairs that are not described here and take advantage of the 24 hour    replacement service  inverter ready for shipping and handed over to a freightforwarding company    within 24 hours  and the SMA Solar Technology AG repair service instead     9 1 Blink Codes             Green Red Yellow Status   flashing flashing flashing OK  startup phase    is permanently lit is not lit is not lit OK  feed in operation   is permanently lit is not lit ground fault or varistor    defective       is permanently lit    OK  initialization                                         is flashing quickly is not lit is not lit OK  stop    3 x per second  is permanently lit is not lit ground fault or varistor  defective  is flashing slowly is not lit is not lit OK  waiting  grid   1 x per second  monitoring   goes out briefly is permanently lit is not lit ground fault or varistor   approx  1 x per defective  second  is not lit is not lit OK  derating   is not lit is not lit is not lit OK  nighttime  deactivation or  Electronic Solar Swi
23. ation Manual    SMA Solar Technology AG Opening and Closing    7 Opening and Closing    7 1 Safety    DANGER   A Risk of lethal electric shock        Before opening the inverter  observe the following   e Ensure that no voltage is present on the AC side       Ensure that neither voltage nor current is present on the DC side       NOTICE   o   Electrostatic discharges can damage the inverter     The internal component parts of the inverter can be irreparably damaged by electrostatic  discharge                   Ground yourself before touching a component part        7 2 Opening the Inverter    l  Disconnect the miniature circuitbreaker and secure against reconnection     2  Pullthe Electronic Solar Switch downward  slightly  towards the wall        3  Use a current probe to ensure that no current is  present in any of the DC cables                 If current is present  check the installation           Installation Manual SMCA6 60A4A EN 1 20471 55    Opening and Closing SMA Solar Technology AG    4  Unlock and disconnect all DC connectors  To do  this  insert the screwdriver into one of the side slots   blade width  3 5 mm  and pull the DC connectors  straight down  Do not pull on the cable while doing  this                  All DC connectors are disconnected from the  inverter  The inverter is entirely disconnected  from the PV array                    DANGER   Danger to life due to high voltages in the inverter     The capacitors in the inverter require 5 minutes to discharg
24. between the negative pole of  each string and the ground potential  PE      4  Measure the voltages between the positive and  negative poles of each string           A ground fault exists if the measured voltages are stable and the sum of the voltages from  the positive pole to the ground potential and from the negative pole to the ground potential  of a string is approximately equal to the voltage between the positive and negative poles     Installation Manual SMCA6 60A4A EN 1 20471 71    Troubleshooting SMA Solar Technology AG       Result Measure  M You have found a ground fault  e        installer of the PV array must remedy  the ground fault in the affected string  You  can determine the location of the ground  fault as described below      Do not reconnect the faulty string        Close the inverter and commission it as  described in section 7 3  Closing the  Inverter   page 58     M You have found no ground fault  It is likely that one of the thermally monitored   varistors is defective        e Check the varistors as described in section  9 3 2  Checking the Function of the  Varistors   page 73                  Location of the Ground Fault    The approximate position of the ground fault can be determined from the ratio of the measured  voltages between the positive pole against ground potential  PE  and the negative pole against  ground potential  PE                     Example   V    200 V       300 V  pm  A          100 V 100 V ni 100 Y 100 V 100 Y                  
25. cable gland at AC connection       Clamping bracket for additional grounding                               1  1  1  1  8  8 Sealing plugs for      DC connectors  1  1  1  2    Conical spring washers    1 x for enclosure lid screws  replacement   1 x for ground terminal  L 2 Cheese head screws  M6x16     1 x for enclosure lid  replacement   1 x for ground terminal                      M 2 Jumpers  1 x for fan test  1 x for the SMA Power Balancer wiring    N 2 Cheese head screws  M6x8  for securing the inverter to the wall mounting  bracket      1 Silicone tube for insulating      SMA Power Balancer connection cable   P 1 Installation Manual   Q 1 User Manual                   Installation Manual SMC46 60A IA IEN 120471 13    Unpacking SMA Solar Technology AG                Object   Quantity   Description  R 1 Set of documents with explanations and certificates  S 1 Supplementary sheet with inverter default settings                3 2 Identifying the Inverter  You can identify the inverter using the type label  The type label is on the right hand side of the    enclosure   The serial number  Serial No   and the type  Type Model  of the inverter  as well as device specific    characteristics are specified on the type label     Installation Manual    14 SMC46 60A IA EN 120471    SMA Solar Technology AG Mounting    4 Mounting    4 1 Safety    DANGER   Danger to life due to fire or explosion        Despite careful construction  electrical devices can cause fires       Do not mount 
26. ction     8 SMC46 60AJA IEN 12047 1 Installation Manual    SMA Solar Technology AG Safety    2 Safety    2 1 Intended Use    The Sunny Mini Central is a PV inverter which converts the direct current of the PV array to alternating  current and feeds it into the power distribution grid     Operating Principle of a PV Plant with Sunny Mini Central    Sunny Mini Central        Distribution Public Grid                   The Sunny Mini Central may only be operated with PV arrays  PV modules and cabling  of protection  class     Do not connect any energy sources other than PV modules to the Sunny Mini Central     When designing the PV plant  ensure that the values comply with the permitted operating range of all  components at all times  The free design program  Sunny Design   www SMA de en SunnyDesign   will assist you  The manvfacturer of the PV modules must have approved the modules for use with this  Sunny Mini Central  You must also ensure that all measures recommended by the module  manufacturer for long term maintenance of the module properties are taken  see also Technical  Information  Module Technology  in the download area of www SMA de en      For safety reasons  it is forbidden to modify the product or install component parts that are not  explicitly recommended or distributed by SMA Solar Technology AG     Installation Manual SMC46 60A IA IEN 120471 9    Safety SMA Solar Technology AG    2 2 Safety Precautions    DANGER   Danger to life due to high voltages in the inve
27. e         e Wait 5 minutes before opening the inverter              5  Ensure that no voltage is present at the DC plugs on  the inverter                 If voltage is present  check the installation              56 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Opening and Closing    6  Loosen all 6 screws of the enclosure lid and remove  the enclosure lid from the front     7  Verify the absence of voltage L with respect to  N at the AC terminal with an appropriate  measuring device        If voltage is present  check the installation                                   8  Verify the absence of voltage L with respect to PE at  the AC terminal with an appropriate measuring  device        If voltage is present  check the installation                                      The inverter is open and no voltage is present     Installation Manual    SMC46 60AA IEN 120471 57    Opening and Closing SMA Solar Technology AG    7 3 Closing the Inverter    1  Secure the enclosure lid with the 6 screws and the  corresponding conical spring washers     Tighten the screws with 6 Nm torque in the order  shown in the figure on the right  The toothing of the  conical spring washers must point toward the  enclosure lid     The scope of delivery of the inverter includes  another spare screw and conical spring washer        DANGER     Danger to life due to enclosure lid carrying voltage        The grounding of the enclosure lid is ensured by the conical spring washers       A
28. e  2    In this case  the ground fault is between the 2nd and 3rd PV modules           M The ground fault check is now complete     72 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Troubleshooting    9 3 2 Checking the Function of the Varistors    Varistors are wearing parts  Their functional efficiency diminishes with age or following repeated  responses as a result of overvoltages  It is therefore possible that one of the thermally monitored  varistors has lost its protective function  and thus the red LED is lit     r      Position of varistors        1   You can determine the position of the varistors using the illustration below        Observe the following assignment of the  terminals        Terminal A  outer terminal  varistor  connection with loop  crimp        Terminal B  middle terminal      Terminal C  outer terminal  varistor  connection without loop  crimp                        Check the function of the varistors as described below   Open the inverter as described in section 7 2  Opening the Inverter   page 55    2  With the aid of a multimeter  determine for both A     varistors in the installed state whether a conductive  connection exists between connectors B and C           Result Measure  M There is a conductive connection   There is probably a different error in the inverter         Contact the SMA Service Line   see section 13  Contact   page 86                   Installation Manual SMC46 60A IA IEN 120471 73    Troubleshooting SM
29. e Startup Phase                49  Self4est in Accordance with DK 5940  Ed  2 2    Applies to    Only   reia  50  Starting the Self Test by                                                  50  Completion of the                      1    51  Opening and Closing                               55  a         55  Opening the                                                 55  Closing the  veto          ERA 58  Maintenance and                                        60  Cleaning the 1                                              60  Checking  Heat                                                      60    SMC46 60A A IEN 120471 Installation Manual    SMA Solar Technology AG Table of Contents    8 2 1  8 2 2  8 2 3    8 3    9  9 1  9 2  9 3  9 3 1  9 3 2  10  10 1  10 2  10 3  10 4    11    11 1   11 1 1  11 1 2  11 1 3    11 2  11 3  11 4  11 5  11 6  11 7  11 8  11 9    Cleaning  the          a                   VR ue RO IR E 60  Checking                      E            EAA 62  Gleaning the Fan Guards    acces    A           63  Checking the Electronic Solar Switch  ESS  for Wear         64  Troubleshooting   c eek bx Re eR ORE E Ren 65  Blink Codes          aa e Sar    bo      65  Error Messages       SA stude           Op EAE 66  Red LED is Permanently Lit                              70  Checking the PV Array for Ground                                      71  Checking the Function of the Varistors        73  DecommissiOnING sss           RR Ea eee ee Rs          75  Disassemb
30. e inside    The fan guards prevent dirt and insects from  entering the device and  if necessary  can be  reordered from SMA Solar Technology AG   see section 13  Contact   page 86             Optional anti theft protection    e   1 To protect the inverter against theft  the back  panel can be secured to the wall at the bottom  using 2 safety screws        The other 2 holes are spares                       Installation Manual SMC46 60A IA IEN 120471 19    Electrical Connection SMA Solar Technology AG    5 Electrical Connection          NOTICE       E   Electrostatic discharges can damage the inverter             Internal component parts of the inverter can be irreparably damaged by static electric  discharge          Ground yourself before touching a component part           5 1 Overview of the Connection Area    5 1 1 Exterior View    The following figure shows the assignment of the individual connection areas on the bottom of the  inverter     A                                                                                  is     y  Object  Description  A DC connectors for connecting the PV strings  B Jack for connecting the Electronic Solar Switch  ESS  DC load disconnection unit  C Cable glands for optional communication      RS485  PG 16   D Cable gland for connection to the power distribution grid  AC   12 mm     25 mm   E Cable glands for SMA Power Balancer             20 SMC46 60AA IEN 120471    Installation Manual    SMA Solar Technology AG Electrical Connec tion   
31. ectors    All PV module connection cables must be equipped with the included DC connectors before  connecting them to the inverter     To assemble the DC connectors  proceed as follows  Ensure the connectors have the correct polarity   The DC connectors have the symbols     and            Cable requirements   e Use a PV1 F cable                 Procedure    1  Lead the stripped cable all the way into the plug   AR       2  Press the clamping bracket down until it audibly  snaps into place        3  Ensure that the cable is correctly positioned        Result Measure  M Ifthe stranded wire is visible in the chamber     Proceed to step 4   of the clamping bracket  the cable is  correctly positioned                    30 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG    Electrical Connection       Result  M Ifthe stranded wire is not visible in the  chamber  the cable is not correctly  positioned              Measure  e Loosen the clamping bracket  To do so   insert a 3 5 mm screwdriver into the  clamping bracket and lever it out            SE busy  y      Remove the cable and go back to step 1           4  Push the threaded joint up to the thread and screw into place with a torque of 2 Nm           The DC connectors are assembled and        now be connected to the inverter as described in  section 5 4 4  Connecting the PV Array  DC    page 33      Installation Manual    SMC46 60AA IEN 120471 31    Electrical Connection SMA Solar Technology AG    5 4 3 Ope
32. ee phase feed in system     Each of the 3 Sunny Mini Central devices in a group must be connected to a different line conductor  of the low voltage grid  L1  L2 and L3               L1  12  L3    N    By activating this electronic circuit  you can stipulate how the other 2 Sunny Mini Central inverters are  to react if there is a device fault with the 3rd Sunny Mini Central or there is a line voltage fault in its  line conductor     e   Three phase grid connection    For further information on this subject  see the Technical Information  Three phase  connection with Sunny Mini Central  in the download area at www SMA de en     The connections for the SMA Power Balancer are galvanically isolated from the rest of the  Sunny Mini Central electronic circuit     5 5 1 Configuration    If the national standard VDE AR N4105 MP or VDE AR NA 105 HP is set  the SMA Power Balancer is  activated by default and set to operating mode  PowerGuard  in SMC 4600A 11  SMC 5000A 11  and SMC 6000 11  All other national standards deactivate      SMA Power Balancer by default in  SMC 4600A 11  SMC 5000A 1 1 and SMC 6000A 11     The SMA Power Balancer is always deactivated by default in SMC 4600A  SMC 5000A   SMC 5000A IT  SMC 6000A and SMC 6000AT  regardless of which national standard is set     The SMA Power Balancer can only be activated or configured using a communication product   To change the  PowerBalancer  parameter  you need a personal access code   the so called  SMA Grid Guard Code  The a
33. eration     Do not expose the inverter to direct solar irradiation as this can cause excessive heating and  thus power reduction     In living areas  do not mount the unit on plasterboard walls or similar to avoid audible vibrations   When in use  the inverter emits noises which may be perceived as a nuisance in a living area     Observe the minimum clearances to walls  other  inverters  or objects as shown in the diagram in  order to ensure sufficient heat dissipation and  sufficient space for removing the   Electronic Solar Switch           Multiple inverters installed in areas with high ambient temperatures    There must be sufficient clearance between the individual inverters to ensure that the    J    cooling air of the adjacent inverter is not taken in     If necessary  increase the clearance spaces and make sure there is enough fresh air supply  to ensure sufficient cooling of the inverters     SMC46 60A A IEN 120471 Installation Manual    SMA Solar Technology AG Mounting    4 3 Mounting the Inverter with the Wall Mounting Bracket    1  Mark the position of the drill holes using the wall mounting bracket and drill the holes   Use at least 2 of the 6 holes  with 1 hole on the right and 1 on the left     217 3 mm   217 3 mm       gt     gt                  gt        20        11     UN                                  5 86 8 mm             79 2           104 6mm    110 0 mm  873mm   1300mm     1300mm    873mm                                                 E  E     z  o 
34. found in the  Technical Information  Miniature Circuit Breaker  in the SMA Solar Technology AG download area  at www SMA de en     DANGER   Danger to life due to fire        When more than 1 inverter is connected in parallel to the same miniature circuit breaker   the protective function of the miniature circuit breaker is no longer guaranteed     can result in a cable fire or destruction of the inverter       Never connect several inverters to the same miniature circuitbreaker         Observe the maximum permissible fuse protection of the inverter when selecting the    miniature circuit breaker     DANGER   A Danger to life due to fire                 When a generator  inverter  and a load are connected to the same miniature  circuit breaker  the protective function of the miniature circuitbreaker is no longer  guaranteed  The current from the inverter and the power distribution grid can accumulate  to overcurrent which is not detected by the miniature circuit breaker     Never connect loads between the  inverter and the miniature circuit breaker  without fuse protection               Always protect loads separately     NOTICE   Damage to the inverter by using screw type fuses as a load disconnection unit     A screw type fuse  e g  DIAZED fuse or NEOZED fuse  is not a switch disconnector and thus  may not be used as a load disconnection unit  A screw type fuse only acts as cable  protection                                         When disconnecting under load using a screw 
35. ge is set     28 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG    5 4 Connecting the PV Array  DC     5 4 1 Conditions for the DC Connection     Using Y adapters for parallel connection of strings    Y adapters may not be visible within close proximity of the inverter or freely accessible       The DC electric circuit may not be interrupted by Y adapters         Observe the procedure for disconnecting the inverter as described in section    7 2  Opening the Inverter   page 55        Requirements for the PV modules of the connected strings       Same type    Same quantity    Identical alignment      Identical tilt               connection cables of the PV modules must be equipped with connectors   The DC connectors for the DC connection are included in the delivery     e        following limiting values at the DC input of the inverter must not be exceeded        Maximum input voltage  600 V  DC           Maximum input current  26 0 A  DC        WARNING     Risk of lethal electric shock or fire        The maximum possible input current per string is limited by the connectors used  If the  connectors are overloaded  an electric arc may occur and there is a risk of fire     e Ensure that the input current for each string does not exceed the maximum    through fault current of the connectors used        Installation Manual    SMC46 60A IA IEN 120471    Electrical Connection       Electrical Connection SMA Solar Technology AG    5 4 2 Assembling the DC Conn
36. guards must be attached according to the  inside inscription   links left  and  rechts right               NOTICE      N       Risk of damage to the inverter through intrusion of insects              fan guards must not be removed permanently  because otherwise the device is  not protected against insects entering        Installation Manual SMC46 60A IA IEN 120471 63    Maintenance and Cleaning    SMA Solar Technology AG    8 3 Checking the Electronic Solar Switch  ESS  for Wear    Check the Electronic Solar Switch for wear before plugging it in  Depending on the shape of the  Electronic Solar Switch  you can estimate the wear on either the metal tongues  shape A  or on the    plastic  shape B         Result       The metal tongues in the Electronic Solar  Switch are undamaged and not discolored   A            Measure  1  Securely attach the Electronic Solar Switch    handle     2  Commission the inverter as described in  section 6  Commissioning   page 48                      plastic in the Electronic Solar Switch  shows thermal deformation                   or     The plastic in the Electronic Solar Switch is  undamaged           The metal tongues in the Electronic Solar  The Electronic Solar Switch can no longer reliably  Switch have a brown discoloration or are disconnect the DC side   burned through  A   1  Replace the Electronic Solar Switch handle  before attaching it again  for the order  number  see section 12  Accessories    page 85     2  Recommission the inverter 
37. he country specific  requirements     Without such external decoupling protection  the inverter will not disconnect from the  power distribution grid when the standard requirement is exceeded            Install external three phase decoupling protection        Installation Manual SMCA6 60A4A EN 1 20471 47    Commissioning SMA Solar Technology AG    6 Commissioning    6 1 Commissioning the Inverter   1  Check the following requirements before commissioning     The inverter is securely in place     AC cables are correctly connected  power distribution grid      DC cables  PV strings  are completely connected     Unused DC inputs are closed using the corresponding DC connectors and sealing plugs     The enclosure lid is securely screwed in place     The Electronic Solar Switch is securely plugged     The miniature circuit breaker is correctly laid out    2  Switch on the miniature circuit breaker         3 LEDs are lit or flashing  the startup phase is starting      Green LED is lit  commissioning was successful   or       Green LED flashes in case of insufficient irradiation  grid connection conditions have not yet  been reached  Wait for sufficient irradiation     or       The red or yellow LED is lit or flashing  there is a fault  Proceed to step 3        A  Green LED  operation       B  Red LED ground fault or varistor 6  defective    C  Yellow LED  Fault       g                         Self test in accordance with DK 5940  Ed  2 2 during initial start up   applies to Italy 
38. ick audibly into position                       7  Ensure that all DC connectors are securely in place     Installation Manual SMC46 60A A 1EN 120471 35    Electrical Connection SMA Solar Technology AG    8  Check the Electronic Solar Switch for wear  as  described in section 8 3  Checking the Electronic  Solar Switch  ESS  for Wear   page 64  and attach             it firmly      NOTICE    gt    Manipulating the connector in the handle can damage the Electronic Solar  Switch     The connector inside the handle must remain movable in order to ensure proper contact   Tightening the screw voids all warranty claims and creates a fire risk         Do not tighten the connector screw in the Electronic Solar Switch handle             NOTICE       o X Electronic Solar Switch can be damaged        If it is not correctly connected  the Electronic Solar Switch can be damaged by high  voltages       Plug the handle firmly onto the jack of the Electronic Solar Switch             Make sure that the device is securely in place             The PV array is connected     You can now commission the inverter as described in section 6  Commissioning   page 48    The following connections are optional     36 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection    5 5 Connection of the SMA Power Balancer    The Sunny Mini Central is equipped with the SMA Power Balancer as standard  This enables a circuit  connection of    Sunny Mini Central inverters to a thr
39. is too high     The inverter disconnects to assure compliance with the power quality of  the power distribution grid        Corrective measures  Check the line voltage at the terminal of the inverter          f  due to the local grid conditions  the line voltage is 253 V or  more  ask the grid operator whether the voltage at the feed in point  can be adjusted  or whether they would agree to an alteration of  the limiting value of parameter  ACVtgRPro  for power quality  monitoring     e If the line voltage is continually within the tolerance range and this  error message is still displayed  contact the SMA Service Line           Bfr Srr    Internal measurement comparison fault or hardware defect           Corrective measures        Ifthis fault occurs frequently  contact the SMA Service Line              66 SMC46 60AA IEN 120471 Installation Manua       SMA Solar Technology AG    Troubleshooting                                                             Message Description and corrective measure  Derating The  Derating  operating state is a normal operating state which may  occur occasionally and can have several causes   Once the inverter enters the  Derating  operating state  it will display the   Derating  warning until the next total disconnection of the device   at the end of the day    Corrective measures  e Check the heat dissipation as described in section 8 2  Checking  Heat Dissipation   page 60    EEPROM Transition fault while data is being written or read from EE
40. istribution grid with the  display message pictured on the right     Both inverters subsequently switch to  Balanced   mode        If the inverters react as described above  the  functionality test has been completed  successfully  Otherwise  check the  configuration     If applicable  reset       PowerBalancer  parameter to the desired setting in all inverters     Switch on the miniature circuitbreaker again     The functionality test has been completed     Installation Manual                E todau         Mode Balanced             SMC46 60AA IEN 120471    45    Electrical Connection SMA Solar Technology AG    5 6 Communication    The inverter is equipped with a slot for communication interfaces in order to communicate with special  data loggers  e g   Sunny WebBox  or a PC with corresponding software  e g   Sunny Data Control  or Sunny Explorer      Refer to the respective communication interface manual for a detailed wiring diagram and an  installation description for the interface     The inverter s active power can be limited or its displacement power factor can be set externally using  the Power Reducer Box from SMA Solar Technology AG  Detailed information on the  Power Reducer Box is available in its Technical Description at www SMA de en     5 7 Setting the Grid and Country Parameters       Changing grid relevant and country parameters         1      change grid relevant parameters  you need    personal access code   the so called  SMA Grid Guard Code  The applicati
41. l   Radio retrofit kit radio Piggy Back for retrofitting an inverter for BEAMPB NR  communication with Sunny Beam  including  antenna  coaxial cable  and PG cable gland   metal    Fan guard fan guard set  right and left  as spare part 45 7202       Power Balancer plug    retrofit kit for retrofitting a Sunny Mini Central  equipped with an SMA Power Balancer to the  SMA Power Balancer plug in system    PBL SMC 10 NR       RS485 retrofit kit    RS485 interface    485PB SMC NR       SMA Power Balancer  Y cable    connecting cable  2 x 2 m  for  SMA Power Balancer plug in system    PBL YCABLE 10       SUNCLIX DC connector          field plug for conductor cross sectional areas  2 5 mm      6 mm        SUNCLIX FC6 SET          Installation Manual    SMC46 60A IA IEN 120471    85    Contact SMA Solar Technology AG    13 Contact    If you have technical problems concerning our products  contact the SMA Service Line   We need the following data in order to provide you with the necessary assistance     Inverter type   Inverter serial number   Type and number of the PV modules connected  Optional equipment  e g  communication products    Blink code or display message of the inverter    SMA Solar Technology AG  Sonnenallee 1   34266 Niestetal  Germany  www SMA de    SMA Service Line  Inverters  49 561 9522 1499  Communication   49 561 9522 2499    Fax   49 561 9522 4699  E Mail  ServiceLine SMA de  86 SMC46 60AA IEN 120471 Installation Manual    SMA Solar Technology AG Legal Restriction
42. lified person        A        Beware of hot surface     The inverter can become hot during operation  Avoid contact during  operation        Observe all documentation that accompanies the inverter        The inverter must not be disposed of together with the household waste  For  more information on disposal  see section 10 4  Disposing of the Inverter    page 76         CE mark     The inverter complies with the requirements of the applicable  EC guidelines        The inverter has a transformer        Direct current  DC        Alternating current  AC        OM A    Degree of protection IP65     The inverter is protected against dust intrusion and water jets from any  angle                       GUTEZEICHEN    Solar                   RAL quality mark for solar products     The inverter complies with the requirements of the German Institute for  Quality Assurance and Labeling           12 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Unpacking    3 Unpacking    3 1 Scope of Delivery    Check the delivery for completeness and any visible external damage  Contact your specialty retailer  if anything is damaged or missing           D    m es a  G H I    K L                   Object  Quantity   Description       Sunny Mini Central  Fan guards  right left           Wall mounting bracket       DC load disconnection unit Electronic Solar Switch  ESS        DC connectors  4 x positive  4 x negative           Cable gland for AC connection       Counter nut for 
43. ling the Inverter                              75  Packing the 1                                               76                                                              76  Disposing of the                                                76  Technical Data                                    77  DEA c E             77  Sunny Mini Central 46004         77  Sunny Mini Central 5000A         eee 79  Sunny Mini Central 60004  2    see 81  General                                                82  Protective DOCS se          rtt S RR          82  National Standards                                    83  Climatic                                                      83  Features    esc ae vs Ute ca cotes              84  Electronic Solar Switch  ESS                             84  OTS A t      wl ans Sota        poets 84  Distribution Systems                                   84    Installation Manual SMC46 60A IA IEN 120471 5    Table of Contents SMA Solar Technology AG    12                   5                                     85    13 Contacta tito     6 SMC46 60A A IEN 120471 Installation Manual    SMA Solar Technology AG Information on this Manual    1 Information on this Manual    1 1 Validity    This installation manual describes the assembly  installation  commissioning  maintenance and  troubleshooting of the following SMA inverters     e Sunny Mini Central 4600A  SMC 4600A  SMC 4600A 1 1   e Sunny Mini Central 5000A  SMC 5000A  SMC 5000A 11  SMC 5000A IT   e Sunny Mi
44. ly after the system has been restarted   i e  all LEDs must have gone out before a restart      1   2     3     62    Open      inverter as described in section 7 2  Opening the Inverter            55      Plug the provided jumper in the slot on the system control board as shown below                                                                                   suc  2000 E  AT             Close the inverter as described in section 7 3  Closing the Inverter   page 58      SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Maintenance and Cleaning    4  Check the fans  air flow     The inverter takes cooling air in from underneath and then blows it back out on the upper sides   Listen for any unusual noise  which could indicate incorrect installation or that the fans are faulty     5  After checking the fans  remove the jumper  Open and close the inverter as described in section  7  Opening and Closing   page 55       The test of the fans has been completed     8 2 3 Cleaning the Fan Guards    The inverter takes cooling air in from underneath via the fans and blows it out again through the fan  guards on the upper sides  Clean the fan guards if they are dirty   Procedure   1  Remove the fan guards     Insert your finger above in the space between the  fan guard and the enclosure and remove the fan  guard to the side     2  Clean the fan guards with a soft brush  a paint  brush  or compressed oir     3  Reattach the fan guards to the inverter     The fan 
45. m switching voltage 800 V  Maximum PV power 12kw  Degree of protection when plugged IP65  Degree of protection when unplugged 1P21  11 8 Torque   Enclosure lid screws 6 0 Nm  Additional ground terminal 6 0 Nm  Cheese head screw for attaching the enclosure to 6 0 Nm  the wall mounting bracket   SUNCLIX lock nut 2 0 Nm  Screw terminal AC connection 2 5 Nm  RS485 communication connection 1 5 Nm  11 9 Distribution Systems   IT system suitable  TN C system suitable  TN S system suitable  TN C S system suitable  TT system suitable  Split Phase suitable  84 SMC46 60AI AEN 12047 1 Installation Manual    SMA Solar Technology AG    12 Accessories    Accessories    You will find the corresponding accessories and spare parts for your product in the following  overview  If required  you can order these from SMA Solar Technology AG or your specialty retailer              Designation Brief description SMA order number  Bluetooth retrofit kit Bluetooth communication interface BTPBINV NR  Insertion tool for the insertion tool for varistors SB TVWZ  replacement of varistors   Electronic Solar Switch  ESS handle spare part ESS HANDLE 04    Also enter the inverter s  serial number                    Negative grounding set   retrofit kit for the negative connection to ground ESHV N NR  of the DC input   Positive grounding set  retrofit kit for the positive connection to ground of ESHV P NR  the DC input   Replacement varistors       of thermally monitored varistors  2  incl  SB TV4  insertion too
46. must face  toward the clamping bracket           The inverter s enclosure is additionally grounded     Installation Manual SMC46 60A IA IEN 120471 27    Electrical Connection SMA Solar Technology AG    5 3 Setting the Display Language  You can set the language of the display using the switches at the bottom of the display assembly inside  the inverter     When selecting the display language  different switching settings apply to inverters that are set to the  Italian national standard DK 5940  You can see the standard to which the inverter was set upon  delivery on the type label and the supplementary sheet provided with the default settings  For more  information  see the Technical Description  Operating Parameters  at www SMA de en     Procedure    1  Open the inverter as described in section 7 2  Opening the Inverter   page 55      2  Set the switches to the required language  as  shown below                                                                       The following switch settings  except for DK 5940  Ca  apply to all national standards     Language Switch S2 Switch S1  German B B   English B A   French A B   Spanish A A                   The following switch settings apply to inverters that  are set to the Italian national standard DK 5940                 Language Switch S2 Switch S1  lladion  BJA     English A A   German B B   French A B                   3  Close the inverter as described in section 7 3  Closing the Inverter   page 58      M The display langua
47. ni Central 6000A  SMC 6000A  SMC 6000A 11  SMC 6000A IT     Keep this manual in a convenient place for future reference     1 2 Target Group    This manual is for electrically qualified persons  The tasks described in this manual may be performed  by electrically qualified persons only     1 3 Additional Information    You will find further information on special topics such as designing a miniature circuit breaker or the  description of the operating parameters in the download area at www SMA de en     Refer to the user manual provided for detailed information on operating the inverter     Installation Manual SMCA6 60A A EN 120471 7     Information on this Manual SMA Solar Technology AG    1 4 Symbols Used    The following types of safety precautions and general information are used in this manual     T DANGER        DANGER indicates a hazardous situation which  if not avoided  will result in death or  serious injury       WARNING     WARNING indicates a hazardous situation which  if not avoided  could result in death or  serious injury       CAUTION     CAUTION indicates a hazardous situation which  if not avoided  could result in minor or  moderate injury                         io                               NOTICE indicates a situation that can result in property damage if not avoided         s    Information        1   Information provides tips that are valuable for the optimal installation and operation of  your product        This symbol indicates the result of an a
48. ning the DC Connector    1  Unscrew the screw connection        2  Unlocking the DC connector  Insert a 3 5 mm  screwdriver into the snap slot on the side and lever  it out         Wi    3  Carefully pull the DC connector apart     4  Loosen the clamping bracket  To do so  insert a  3 5 mm screwdriver into the clamping bracket and  lever it out     5  Remove the cable             The cable is now removed from the DC connector     32 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection    5 4 4 Connecting the PV Array  DC   ES                  Danger to life due to high voltages in the inverter            Before connecting the PV array  ensure that the miniature circuitbreaker is switched    off                    o   Excessive voltages can destroy the measuring device                            Only use measuring devices with a DC input voltage range up to at least 1 000 V        l  Disconnect the miniature circuitbreaker and secure against reconnection     2        the Electronic Solar Switch downward  slightly  towards the wall     3  Check the connection cable of the PV modules for  correct polarity and make sure that the maximum  input voltage of the inverter is not exceeded     At an ambient temperature above 10  C  the  open circuit voltage of the PV modules must not be  more than 90  of the maximum inverter input  voltage        Otherwise  check the plant design and the   PV module connection  If this is not done  the  maximum in
49. ogy AG Commissioning    6 3 2 Completion of the Self test    Note the values which are displayed during the self test  These values must be entered into a test  report  The test results of the individual tests are displayed 3 times  one after the other   The respective display message is displayed for 10 seconds     The self test changes the upper and lower disconnection thresholds for each protective function      a  linear basis with a modification of 0 05 Hz s and 0 05 Vn s for the frequency and voltage  monitoring  As soon as the actual measured value is outside the permitted range    altered disconnection threshold   the inverter disconnects itself from the power distribution grid  In this  way  the inverter determines the reaction time and checks itself     Overvoltage Test    The inverter begins with the overvoltage test  During the   a ant  Butotezt   test sequence  the voltage limit applied is shown in the   display of the inverter     2562                    ZA  Un       The voltage limit is reduced successively until the  disconnection threshold is reached and the inverter disconnects from the power distribution grid     Once the inverter has disconnected from the power distribution grid  the display successively shows  the following values one after the other           i i 7  Disconnection value  Usiore di soglia    nons zu                 Calibration value          Reaction time       Current line voltage              Installation Manual SMC46 60A IA IEN 120471 5
50. oltages in the event of outage of the power  distribution grid        If you set the inverter to stand alone grid operation  it does not fulfill any country specific  standards and guidelines  If there is a power distribution grid outage  there is consequently  a danger of feedback       Never operate the inverter directly on the power distribution grid when set to  stand alone grid operation        5 7 3    1    Additional Country Parameters    Requirement for the setting    Set the installation country as described in section 5 7 1  Setting the Installation Country    page 46  before setting the country parameter described here     The deactivation criteria  voltage  frequency  impedance  are specified via country parameters as  with all Sunny Mini Central inverters     The additional default country parameter  MVtgDirective  expands the deactivation limits of the  inverter for voltage and frequency to a maximum minimum  This country setting may only be selected  if the PV plant or the inverter is operated with external three phase decoupling protection  which will  automatically disconnect the inverter from the power distribution grid if non permissible voltage and  frequency values occur  Device protection is still guaranteed        DANGER     Risk of lethal electric shock if external decoupling protection is missing        At country setting  MVtgDirective   the inverter may only be operated with an external  three phase decoupling protection device which complies with t
51. on form for the personal access code is available in  the download area at www SMA de en  in the  Certificate  category of the respective  inverter        Ensure that you discuss the changes to these parameters with your grid operator     A detailed description of the operating parameters for the inverter is available in the download area  at www SMA de en in the category  Technical Description  of the respective inverter     5 7 1 Setting the Installation Country    Using the  Default  parameter  you can set the installation country and or the grid connection  standard valid for the country via a communication product  e g   Sunny WebBox  or a PC with  corresponding software  e g   Sunny Data Control or Sunny Explorer   This  however  is only required  if the inverter was originally ordered for another country  You can see the standard to which the  inverter was set upon delivery on the type label and on the included supplementary sheet with the  default settings     46 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection    5 7 2    Setting Stand alone Grid Operation    To operate the inverter in a stand alone grid system with Sunny Island  you must set the  Default   parameter to stand alone grid   OFF Grid   operation     You have several possibilities to set the inverter to stand alone grid operation       Setting via Sunny WebBox    or      Setting via Sunny Data Control or Sunny Explorer    DANGER     Danger to life due to high v
52. only     mie    The Italian DK 5940 standard requires that an inverter must only be connected to the  power distribution grid if the disconnection times for overvoltage  undervoltage   minimum frequency and maximum frequency have been checked     Start the self test as described in section 6 3  Selftest in Accordance with DK 5940  Ed   2 2  Applies to Italy Only    page 50   The test takes approx  8 minutes     3  Read section 9  Troubleshooting   page 65  and if necessary  eliminate the error or fault     48 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Commissioning         6 2 Display Messages During the Startup Phase          e After commissioning  the inverter displays the  device type in the startup phase     i        Sunma Hini Central  llocs  e After 5 seconds or when you tap again on the    enclosure lid  the firmware version of the internal  processors is displayed by the inverter     EFE Laerzion Manx    SER Werzion Hamm       e After a further 5 seconds or when you tap again   the configured country standard is displayed by the  inverter  example   VDE AR N4 105 MP       UpE BER HA18S WHP          Showing the display messages again  valid as of firmware version 2 15     e  1   If you want to view the display messages of the startup phase again while in normal  operation  tap the enclosure lid twice in quick succession     Installation Manual SMC46 60A IA IEN 120471 49    Commissioning SMA Solar Technology AG    6 3 Self test in Accordance 
53. order to be able to connect the SMA Power Balancer with a Sunny Mini Central 9000TL   10000TL      1100011  the Sunny Mini Central 4600A  5000A or 6000A must be  equipped with a special plug  3 inverters are then connected together with a special    connection cable     You can order the plug and the connection cable from SMA Solar Technology AG or your  specialty retailer  Section 12  Accessories   page 85  contains a list of the order numbers     SMC46 60AA IEN 120471    Installation Manual    SMA Solar Technology AG    5 5 3 Testing the Functioning    Electrical Connection    To test whether the SMA Power Balancer operates correctly  proceed as follows     1   2     a    Select the  PhaseGvard  setting of the  PowerBalancer  parameter for all 3 inverters     Check whether all inverters in the group are feeding the power distribution grid normally        If the green LED lights up steadily or if the  display message pictured on the right appears   proceed to step 3     or       If all inverters in this group show the display  message pictured on the right  Check the  installation of the SMA Power Balancer and  contact the SMA Service line  if necessary     Switch off the miniature circuit breaker for  1 of the 3 inverters     The inverter with a deactivated miniature  circuit breaker then indicates a line voltage fault  with the display message pictured on the right    Bfr  and  Srr  are irrelevant      The other 2 inverters then also disconnect  themselves from the power d
54. planation    Operation display  Indicates the operating state of the inverter        Ground fault or varistor defective  Read section 9 3  Red LED is  Permanently Lit   page 70         Error or fault  Read section 9  Troubleshooting   page 65         i   You can operate the display by tapping the enclosure lid   A e Tapping once  the backlight switches on or the display scrolls to the  next display message     e Tapping twice in quick succession   The inverter shows the display  messages from the startup phase again  see section 6 2  Display  Messages During the Startup Phase   page 49       DC load disconnection unit Electronic Solar Switch  ESS               When the Electronic Solar Switch is plugged in  the DC electric  circuit is closed               To interrupt the DC electric circuit and safely disconnect the  inverter when under load  you must first remove the Electronic Solar  Switch    and then all DC connectors                          for SMA bonus program   You will find information on the SMA bonus program at   www SMA Bonus com                      This function is valid from firmware version 2 15       QR Code is a registered trademark of DENSO WAVE INCORPORATED        Installation Manual SMC46 60A IA IEN 120471 11    Safety    SMA Solar Technology AG    2 3 2 Symbols on the Type Label       Symbol       Explanation  Beware of hazardous voltage     The inverter operates at high voltages  All work on the inverter may only be  carried out by an electrically qua
55. pplication form for the personal access code is available in the  download area at www SMA de en  in the  Certificate  category of the respective inverter     The configuration options are described below     Installation Manual SMC46 60A IA IEN 120471 37    SMA Solar Technology AG    Electrical Connection    Configuration Options    There are 4 different configuration options for the  PowerBalancer  parameter        Local connection requirements    1 Select the respective setting and always observe the local connection requirements and  provisions of your grid operator       FaultGuard  This operating mode allows for the implementation of a three phase line voltage monitoring   which also reacts to device faults       If 1 of the 3 inverters indicates a line voltage fault and stops feeding in   the other 2 inverters also disconnect from the power distribution grid immediately     LS  lt  gt  Sy  Grid voltage fault  Grid disconnection  Grid disconnection         Output  O VA         Output  O VA       Output  O VA      If 1 of the 3 inverters indicates a device fault and stops feeding in   the other 2 inverters also disconnect from the power distribution grid 5 minutes later     eO KY dL FEN  SEI                 M    Device fault  Grid disconnection Grid disconnection        Output  O VA     3 after 5 min  J E after 5 min     Output  OVA _    Output  OVA    5    38 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection        PhaseGuard  
56. rrent with  lt  3    AC voltage  lt  2  and   AC power  gt  50  of rated power   Rated power frequency 50 Hz   AC power frequency 50 Hz 60 Hz  Operating range at AC power frequency 50 Hz 44 Hz    55 Hz  Operating range at AC power frequency 60 Hz 54 Hz    65 Hz  Displacement power factor  adjustable    O 8 overexcited    0 Bunderexcited       Power factor at nominal AC power         1       Feed in phases    1       Connection phases    1       Overvoltage category according to    IEC 60664 1                  4 600 VA with VDE AR N 4105     Applies to SMC 4600A 11      Applies to SMC 4600A          Efficiency  Maximum efficiency  nmax 96 1   European weighted efficiency  ney 95 3                 78 SMC46 60A A IEN 120471    Installation Manual    SMA Solar Technology AG    11 1 2 Sunny Mini Central 5000A    Technical Data                                  DC Input   Maximum DC power at cos      1 5750W  Maximum input voltage   600 V  MPP voltage range 246       480 V  Rated input voltage 246 V  Minimum input voltage 211V  Start input voltage 300 V  Maximum input current 26    Maximum input current per string 26 A  Number of independent MPP inputs 1  Strings per MPP input 4               The maximum open circuit voltage that can occur with   10     cell temperature may not exceed the maximum input voltage     Installation Manual    SMC46 60A A IEN 120471    79                                                    Technical Data SMA Solar Technology AG  AC Output   Rated power at 2
57. rter          All work on the inverter may only be carried out by an electrically qualified person     CAUTION    N Risk of burns due to hot enclosure parts       Do not touch the enclosure during operation             Only touch the enclosure lid during operation       NOTICE   o   Dust and water intrusion can damage the inverter                         the Electronic Solar Switch has been pulled out  the inverter only provides degree of  protection IP21  The inverter is then no longer protected against water and dust intrusion   In order to also maintain degree of protection IP65 during temporary decommissioning   proceed as follows    e Unlock and disconnect all DC connectors        Open all DC connectors and remove the cables      Close all DC inputs with the corresponding DC connectors and the supplied sealing   plugs       Firmly connect the Electronic Solar Switch again                PV array grounding  1 Comply with the local regulations for grounding the PV modules and      PV array  In order  to maintain the best possible protection for both the PV plant and human life   SMA Solar Technology AG recommends connecting together the PV array frame and other  electrically conductive surfaces and grounding them     10 SMC46 60AJA IEN 12047 1 Installation Manual    SMA Solar Technology AG Safety    2 3 Explanation of Symbols    This section gives an explanation of all the symbols found on the inverter and on the type label     2 3 1 Symbols on the Inverter       Symbol Ex
58. s    The information contained in this document is the property of SMA Solar Technology AG  Publishing its content  either partially or  in full  requires the written permission of SMA Solar Technology AG  Any internal company copying of the document for the  purposes of evaluating the product or its correct implementation is allowed and does not require permission     SMA Factory Warranty    The current guarantee conditions come enclosed with your device  These are also available online at www SMA de and can be  downloaded or are available on paper from the usual sales channels if required     Trademarks    All trademarks are recognized even if these are not marked separately  Missing designations do not mean that a product or brand  is not a registered trademark     The Bluetooth  word mark and logos are registered trademarks owned by Bluetooth SIG  Inc  and any use of such marks by  SMA Solar Technology AG is under license     SMA Solar Technology AG   Sonnenallee 1   34266 Niestetal   Germany   Tel   49 561 9522 0   Fax  49 561 9522 100   www SMA de   E Mail  info SMA de   O 2004 to 2012 SMA Solar Technology AG  All rights reserved    Installation Manual SMCA6 60A A EN 120471 87    SMA Solar Technology    SMA Solar Technology AG  www SMA de   SMA America  LLC  www SMA America com    SMA Technology Australia Pty   Ltd     www SMA Australia com au   SMA Benelux SPRL  www SMA Benelux com   SMA Beijing Commercial Co   Ltd   www SMA China com   SMA Czech Republic s r o   www S
59. scribed in section  7 3  Closing the Inverter   page 58         M        check and replacement of the varistors is  completed     74 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Decommissioning    10 Decommissioning    10 1 Disassembling the Inverter  1  Open the inverter as described in section 7 2  Opening the Inverter   page 55    2  Remove all cables from the inverter     Close the inverter with the 6 screws and the  corresponding conical spring washers     4  Remove the fan guards from both sides     5  Remove      2 screws on the left and right side of the  inverter that attach it to the wall bracket     6  Disconnect the anti theft protection  if applicable        Installation Manual SMC46 60A IA IEN 120471 75    Decommissioning SMA Solar Technology AG    7  Remove the inverter upwards from the wall  mounting bracket     8  Use the side handles  above and below  or a steel  rod  maximum diameter 30 mm  to transport the  inverter  The rod must be pushed through the  enclosure openings             The inverter is disassembled     10 2 Packing the Inverter    If possible  always pack the inverter in its original packaging  If it is no longer available  you can also  use an equivalent carton  The carton must be completely closeable  have a handle system and be  made to support both the weight and size of the inverter     10 3 Storing the Inverter    Store the inverter in a dry place where ambient temperatures are always between   25  C and  60  C 
60. t the inverter again and contact  the SMA Service Line  see section 13  Contact   page 86             Watchdog Internal program run fault   Watchdog Srr Corrective measures              Ifthis fault occurs frequently  contact the SMA Service line              9 3 Red LED is Permanently Lit    IF the red status display LED is permanently lit during operation  there is a ground fault in the PV array  or at least one of the varistors for overvoltage protection is defective     Procedure  1  Check for ground faults in the PV array as described in section 9 3 1  Checking the PV Array  for Ground Faults   page 71    2  If the red LED continues to be lit  check the varistors as described in section 9 3 2  Checking the  Function of the Varistors   page 73      70 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Troubleshooting    9 3 1 Checking the PV Array for Ground Faults    l  Disconnect the inverter from both the DC and AC sides as described in section 7 2  Opening  the Inverter   page 55      DANGER   A Risk of lethal electric shock          Only touch the cables of the PV array on their insulation       Do not connect strings with ground faults to the inverter     NOTICE   Excessive voltages can destroy the measuring device       Only use measuring devices with a DC input voltage range up to at least 1 000 V                    2  Measure the voltages between the positive pole of    each string and the ground potential  PE      B    3  Measurethe voltages 
61. taly    The unbalanced load for inverters set to the Italian national standard DK 5940 is limited  to 6 kVA over a 10 minute average       If 1 of the 3 inverters indicates a line voltage fault or device fault and stops feeding in   the other 2 inverters automatically limit their power to 4 6 kVA over a 10 minute average                 V    Grid voltage fault    Output limitation    Output limitation   SA or device fault   A    Output  4 6               Output 46kVA           Output  O VA            40 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG    Electrical Connection    5 5 2 Cabling    Cable Requirements   For cabling the SMA Power Balancer  use a  LiYCY  cable  structured as shown here     Indoor  LiYCY 2 x 2 x 0 25    Outdoor  Li2YCYv 2x 2 x 0 25                               Position Designation   A Flexible insulation   B Shielding      Twisted pair 2  2    0 25 mm       Twisted pair 1  2    0 25 mm         Installation Manual SMC46 60A IA IEN 120471 41    SMA Solar Technology AG    Electrical Connection    Overview of the Connection Area                                                                                                                                                                                                                                                                                           CF     LS       E  Um  12                       QO Ed OY   OOOO00000U Q           7      55                                    
62. tch  not connected   is lit flashing fault  is permanently lit is not lit ground fault or varistor  defective  is lit flashing ground fault or varistor       defective and fault          Installation Manual    SMC46 60A IA IEN 120471 65    Troubleshooting    SMA Solar Technology AG    9 2 Error Messages    When a fault occurs  the inverter generates a message which depends on the operating mode and  the type of the fault detected        Message  IPV Overvoltage   IDISCONNECT DC     Description and corrective measure       Overvoltage at DC input     Overvoltage can destroy the inverter        Corrective measures  Disconnect the inverter from the power distribution grid immediately   1  Disconnect the miniature circuit breaker   2  Remove the Electronic Solar Switch   3  Remove all DC connectors   4  Check the DC voltage       Ifthe DC voltage is above the maximum input voltage  check the  PV plant design or contact the PV array installer       Ifthe DC voltage is below the maximum input voltage   reconnect the inverter to the PV array as described in section  5 4 4  Connecting the PV Array  DC    page 33      If the message occurs again  disconnect the inverter again and contact  the SMA Service Line  see section 13  Contact            86             ACVtgRPro    The 10 minute average line voltage is no longer within the permissible  range  This can be caused by either of the following     e      line voltage at the terminal is too high     The grid impedance at the terminal 
63. ted   miniature circuit breaker  fuse     e AC cable is broken           cable is highly resistive    The inverter disconnects itself from the power distribution grid for safety  reasons           Corrective measures  e Check the line voltage and connection on the inverter     e If the line voltage lies outside the acceptable range because of  local grid conditions  ask the grid operator if the voltages can be  adjusted at the feed in point or if they agree to changes in the  values of the monitored operating limits   operating parameters  Vac Min and Vac Max               line voltage lies within the tolerance range  yet  Vac Bfr  or   Vac Srr  faults are still displayed  contact the SMA Service Line              Installation Manual    SMC46 60A IA IEN 120471 69    Troubleshooting SMA Solar Technology AG       Message Description and corrective measure  UpvMax Overvoltage at DC input  The inverter may be damaged        Corrective measures  Disconnect the inverter from the power distribution grid immediately   1  Disconnect the miniature circuit breaker   2  Remove the Electronic Solar Switch   3  Remove all DC connectors   4  Checkthe DC voltage       Ifthe DC voltage is above the maximum input voltage  check the  PV plant design or contact the PV array installer       Ifthe DC voltage is below the maximum input voltage   reconnect the inverter to the PV array as described in section    5 4 4  Connecting the PV Array  DC    page 33      If the message occurs again  disconnec
64. the inverter on flammable construction materials       Do not mount the inverter in areas where highly flammable materials are stored       Do not mount the inverter in a potentially explosive atmosphere     CAUTION      Risk of burns due to hot enclosure parts       Mount the inverter in such    way that it cannot be touched inadvertently     CAUTION    N Risk of injury due to the heavy weight of the inverter       Take the inverter s weight of approx  63 kg into account for mounting                          4 2 Selecting the Mounting Location    Consider the following requirements when selecting the mounting location     e        mounting method and location must be suitable for the inverter s weight and dimensions   see section 11  Technical Data   page 77         Mount on a solid surface                mounting location must at all times be clear and safely accessible without the use of  additional aids such as scaffolding or lifting platforms  Non ulfillment of these criteria may  restrict servicing       max  45                  Installation Manual SMCA6 60A4A EN 1 20471 15    Mounting SMA Solar Technology AG    i    Mount vertically or tilted backwards by max  45       The connection area must point downward    Never mount the device with a forward tilt    Never install the device with a sideways tilt    Do not mount horizontally    Mount at eye level to allow operating states to be read at all times    The ambient temperature should be below 40  C to ensure optimum op
65. tion     Installation Manual SMC46 60A IA IEN 120471 59    Maintenance and Cleaning SMA Solar Technology AG    8 Maintenance and Cleaning    8 1 Cleaning the Inverter    If the inverter is dirty and the visibility of the operating data and operating states of the inverter is only  limited  clean the enclosure lid  the display and the LEDs with a damp cloth  Do not use any corrosive  substances  e g   solvents or abrasives  for cleaning     8 2 Checking Heat Dissipation    8 2 1 Cleaning the Fans   If the fan guards are soiled with loose dust  they can be cleaned using a vacuum cleaner    If you do not achieve satisfactory results with a vacuum cleaner  dismantle the fans for cleaning   Procedure    l  Disconnect the inverter from both the DC and AC sides as described in section 7 2  Opening  the Inverter   page 55      2  Wait for the fans to stop rotating     Cleaning the Fan Guards  3  Removing the fan guards       Press both latches on the right edge of the fan  guard to the right using a screwdriver and  loosen from the retainer       Carefully remove the fan guard                    4  Clean the fan guards with a soft brush  a paint brush  a cloth or compressed air     60 SMC46 60A A IEN 120471 Installation Manual    Maintenance and Cleaning    SMA Solar Technology AG    Cleaning the Fans  5  Press the front latches backward and the rear latch  forward      gt  NA             6  Remove the fan by pulling it slowly and carefully downward     7  Unlock and remove the plug 
66. tion Grid  AC              23  Conditions for      AC Connection                                  23  Connecting the Inverter to the Power Distribution Grid  AC               25  Additional Grounding of the Enclosure                               27    Installation Manual SMC46 60A A IEN 120471 3    Table of Contents SMA Solar Technology AG    5 3    5 4   5 4 1  5 4 2  5 4 3  5 4 4    5 5   5 5 1  5 5 2  5 5 3    5 6    5 7   5 7 1  5 7 2  5 7 3    6 1  6 2  6 3    6 3 1  6 3 2    7 1  7 2  7 3    8 1  8 2    Setting the Display                                            28  Connecting the PV Array                                  29  Conditions for      DC Connection                                  29  Assembling the DC Connectors        eee eee eee eee 30  Opening the DC Connector       0  eens 32  Connecting the PV Array  DC                   e e                     33  Connection of the SMA Power Balancer                   97  Configuration       x1    a tne a 37           oL Aat heo s      ad t an edes a ete 41  Testing the Functioning      isis 45   ComfmRICdlopis s ss tara f oe era 46  Setting the Grid and Country                                       46  Setting the Installation                                                 46  Setting Stand alone Grid                                                 47  Additional Country Parameters    eee 47  Commissioning  2534730   da 48  Commissioning the                                           48  Display Messages During th
67. ttach the conical spring washers for all 6 screws with the toothing facing toward the  enclosure lid        2  Checkthe DC connectors for correct polarity and connect them   To unlock the DC connectors  see section 7 2  Opening the Inverter   page 55                                    3  Close all the DC inputs that are not needed as described in section 5 4 4  Connecting the PV  Array  DC    page 33  to seal the inverter     58 SMC46 60AA IEN 120471 Installation Manual    SMA Solar Technology AG Opening and Closing    4  Check the Electronic Solar Switch for wear  as  described in section 8 3 and attach it firmly              NOTICE   E    Manipulating the connector in the handle can damage the  Electronic Solar Switch     The connector inside the handle must remain movable in order to ensure proper contact   Tightening the screw voids all warranty claims and creates a fire risk         Do not tighten the connector screw in the Electronic Solar Switch handle              NOTICE     LE X Electronic Solar Switch can be damaged        If it is not correctly connected  the Electronic Solar Switch can be damaged by high  voltages       Plug the handle firmly onto the jack of the Electronic Solar Switch           e Make sure that the device is securely in place        Switch on the miniature circuit breaker     6  Check whether the display and the LEDs indicate a  normal operating state  see section  6  Commissioning   page 48                    inverter is now closed and in opera
68. type fuse  the inverter can be damaged       Use only a switch disconnector or a miniature circuit breaker as a load disconnection  unit              24 SMC46 60AA IEN 1 20471 Installation Manual    SMA Solar Technology AG Electrical Connection    5 2 2 Connecting the Inverter to the Power Distribution Grid  AC     1     Check the line voltage and compare with  Vac nom  on the type label     The exact operating range of the inverter is specified in the operating parameters   The corresponding document is available in the download area at www SMA de en     Disconnect the miniature circuitbreaker and secure against reconnection     Loosen all screws of the enclosure lid and remove  the lid              Remove the adhesive tape from the      enclosure opening  see  D       Page 20      Insert the AC cable gland from the outside into the enclosure opening and tighten it from the  inside with the counter nut     Unscrew the cable gland s lock nut and pass it over the cable   Route the cable through the cable gland to the AC terminal     Connect L  N and the protective conductor  PE  to  the terminal blocks using a screwdriver in  accordance with the label        To do this  the PE insulated conductor must be 5 mm  longer than the L and N insulated conductors           L and N must not be swapped                                         Installation Manual SMC46 60A IA IEN 120471 25    Electrical Connection SMA Solar Technology AG    9  Tighten the lock nut firmly to the cable gland
69. verter input voltage can be exceeded  at low ambient temperatures     Installation Manual SMC46 60A A IEN 120471 33    Electrical Connection SMA Solar Technology AG        N   NOTICE     IM            9 X Overvoltage can destroy      inverter            If the voltage of the PV modules exceeds the maximum input voltage of the inverter   it can be destroyed by overvoltage     This will void all warranty claims               not connect strings with an open circuit voltage greater than the maximum input  voltage of the inverter               Check the plant design        4  Check the strings for ground faults as described in section 9 3 1  Checking the PV Array for  Ground Faults   page 71      5  Connect the assembled DC connectors to the inverter     M The DC connectors click audibly into position                                6   n order to seal the inverter  all the DC inputs that are not required have to be closed with  DC connectors and sealing plugs     Sealing plugs         Do not plug the sealing plugs directly into the DC inputs on the inverter     For unused DC connectors  push down the   clamping bracket and push it onto the cable     gland        34 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technology AG Electrical Connection      Plug the sealing plug into the DC connector       Tighten the DC connector  torque  2 Nm           Insert the DC connectors with sealing plugs into  the corresponding DC inputs on the inverter        M The DC connectors cl
70. with DK 5940  Ed  2 2   Applies to Italy Only     6 3 1 Starting the Self Test by Tapping    You can start testing the disconnection times by tapping on the enclosure lid  A prerequisite here is  that the country configuration of the inverter has been set to Italy  IT DK5940  or  trimmed    Proceed as follows for checking the disconnection times     1  Connect      PV array to the inverter  The inverter can only initialize if the PV array produces  enough power  It is therefore not possible to test the disconnection times at night     2  Connectthe inverter on the AC side  For this  you have to establish the AC connection   AC plug or direct connection  and or switch on the miniature circuit breaker     3  The inverter is now in the initialization phase  i e  all    LEDs are lit at the same time     Start the self test immediately after all 3 LEDs have gone out by tapping on the display of the  inverter     4  The question of whether you would like to start the  test sequence appears in the display  Tap on the  display again within 30 seconds to confirm the  question     Audio BHutotezt       Once you have started the test sequence  the inverter checks the disconnection times for overvoltage   undervoltage  maximum frequency and minimum frequency one after the other  During the tests  the  inverter shows the values in the display which are described in section 6 3 2  Completion of the  Selftest   page 51      50 SMC46 60A IA IEN 120471 Installation Manual    SMA Solar Technol
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
file - Frontiers in Zoology  Manual de uso y mantenimiento Índice general  MOTO-POMPES GLAPET PALETTE  KJ-Lincam - K-Team  KitchenAid 9871915A User's Manual  Samsung CE2774 User Manual  Rose electronic RS232 User's Manual  Page 1 Page 2 田植機重要安全ポイ ント ー. ほ場まで移動するときは  Desenho, Especificação e Tecnologia de Sensores  point 2 kurz-spa-180412-01.indd    Copyright © All rights reserved. 