1. Channel 2 Flash Dimmer e o III ZN caution RISK OF ELECTRIC SHOCK DO NOT OPEN Hot Lamp Allow to cool for 15 minutes before replacing the lamp DMX Control Dipswitch 10 On POWERMBUPPLY EQUINXX WWW PROLIGHT CO UK tt 10 0ff MIN MAX sLow rast Emi CEO FIREGRACKER ol Music Control Dipswitth 9 Off 10 Off no VW DMJAIN Q Identification 1 DMX input 2 DMX output 3 Dip switches 4 Power input 5 Flash dimmer control 6 Speed control T Fuse Main features e Bright 1500 Watt Lamp e Adjustable flash and intensity rate e Flash rate range of 1 15 Fps e Adjustable hanging yoke e Thermostat protection e Large coverage area e Easy lamp replacement Overheat protection 1 The internal micro processor will automatically limit the flash dimmer level when the lamp flashes for a long period of time The lamp can flash continuously for about 5 minutes with the highest flash speed and dimmer level After that the flash dimmer will gradually decrease to the level of 50 2 When the inside thermostats temperature exceeds 100 C the lamp will automatically switch off Note If the user does not want this thermostat function enabled keep the fixtures angle to the vertical surface more than 45 A Lighting angle Equinox Firecracker DMX Set up DMX 512 e DMX Digital Multiplex is a universal protoc
2. 02 20025208 00202904300 625200 402 ER A ee FEINE DE AEREAS EA EI Ep AA PA AAA AAA SALAS SEA 7 0 55 2700 a aes 305 007 05 01 Oo je e 1 SO jos fm Jo PO Li fo fo JO S Ww M E pE A AA POND A E E A A k gt q k mm el qe gt gt _ q gt q Dip Switch position
3. Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 3 Pin XLR to 5 PIN XLR Conversion Conductor 3 Pin XLR out 5 Pin XLR in Ground shield Pin 1 Pin 1 Negative Pin 2 Pin 2 Positive Pin 3 Pin 3 pa 49 fe eb O 2 0 xX T O 09 2 m Equinox Firecracker DMX Dip Switch Quick Reference Chart Dip Switch Position EC E E 100 1200 0 ee EHE DMX DIP SWITCH TIT PT PT TTT TT eee pa o e a 255 e TO 352 381 15205 200 El AJ LA EI ka 7 255297 5835138 2 DMX Address 2 2 a 154 168 160250 202204305 358 200 422 254 050 AE 16206250250 202304500 200 69002404 To 732 104 106 aw 250 202 324365300 220 fa aa Tun Tao
4. and do not modify the equipment e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the systems life e Only use the equipment indoors e Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from dat
5. EQUIN X www prolight co uk FIREGRACKER Order code STRO12 user manual Equinox Firecracker WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Equinox Firecracker Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment
6. e of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property HALOGEN LAMP WARNING This fixture is fitted with halogen lamps which are highly susceptible to damage if improperly handled Never touch the lamp with your bare fingers as the oil form your hands will shorten the lamp life Also never move the fixture until the lamps have had ample time to cool Remember lamps are not covered under warranty conditions Equinox Firecracker Technical specifications You should find inside the Equinox carton the following items 1 Equinox Firecracker strobe 2 Instruction manual Technical Specifications DMX channels 2 Voltage AC 240V 50Hz Fuse 15 Amp Power Consumption 1500W Dimensions 378 x 100 x 165mm Weight 2 1Kgs Operations There are 3 operating modes to choose from 1 Manual 2 Sound Active 3 DMX Manual Mode To run the Firecracker Strobe in Manual mode set all dip switches to the OFF position In manual mode the unit will function as a normal strobe light Rate speed and intensity brightness are set directly on the unit Note that these sett
7. ings are made by using the controls on the rear of the unit Once the settings are made they can only be changed by physically adjusting the controls on the unit Be aware of this if you plan on installing your strobe in a permanent installation Flash speed is controlled via the SPEED control Flash dimming is controlled via the DIMMER control Sound active Mode To run the Firecracker Strobe in Sound active mode set dip switch 9 to the ON position The Dimming will still be controlled by the DIMMER control on the back of the unit Note that these settings are made using the controls on the rear of the unit Once the settings are made they can only be changed by physically adjusting the controls on the unit Be aware of this if you plan on installing your strobe in a permanent installation Flash Dimming is controlled via the DIMMER control Flash Speed is controlled by the Music DMX Mode To run the Firecracker Strobe into DMX mode set dip switch 10 to the ON position You can now set the required DMX address using dip switches 1 to 9 The start address for this fixture is 1 Please refer to the chart below for DMX functions DMX Chart channel vae Funden 0 255 Flash speed 0 255 Flash dimmer Equinox Firecracker Overview Over view Fixture Control Dipswitch 9 Speed Flash Speed Dimmer Flash Dimmer POWER AC 240V 50Hz 15A Fuse T15A 250V 6 3x32mm Channel 1 Flash Speed
8. ol used as a form of communication between intelligent fixtures and controllers ADMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DATA Cable DMX cable requirements for DMX operation e The Equinox Firecracker can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input out put figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split Equinox Firecracker DMX Set up Notice e Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR A Eee EEN FOT EEN ENE SERENE XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground O Pin 2 Negative FIGURE 3 FIGURE 2