Home

the ArcEquine 2 User Manual.

image

Contents

1. O gP ArcEquine arcequine User Manual Contents What s in the box Charging the Delivery unit Quick start quide How to turn the unit on Guide to treatment programmes Selecting treatment programme Programming the unit Activating the programme Attaching the leg strap Troubleshooting Important information ArcEquine small wonder What is ArcEquine ArcEquine is a drug free non evasive sub sensory treatment which uses microcurrent technology What can it do for your horse Rapid regenerative repair to all tissue including tendons ligaments fractures and wounds Promotes effective dispersal and elimination of swelling bruising inflammation pain and Lactic acid ArcEguine can also be used for hormonal imbalance immune auto immune deficiency e g sarcoids behavioural problems stress anxiety ArcEquine is equally as effective for prevention and maintenance as it is for restoration How does it work Every cell within the body communicates with all other cells by means of a series of minute cell specific sequences of electrical current These regulate the proper functioning of the body If there is disease or damage to a group of cells things fail to work or fail to work properly By re introducing the current from an external source ArcEquine kick Starts and accelerates many essential metabolic processes that enable full restoration in a fraction of the normal healing times with little and
2. High High High Audible Beep Alert enabled High High Low Audible Beep Alert disabled Guide to treatment programmes Each programme lasts 3 hours and should be repeated daily throughout the course of the treatment If the unit is not switched off after each delivery period it will reset after one hour and run for a further three hours However no harm will be done as you cannot over use ArcEquine Please note no two horses respond at the same rate therefore timings shown serve only as a guide and after completion of selected programme it may be necessary to reassess and repeat Programme 1 Programme 2 Programme 3 Programme 4 Standard initiation Weeks 2 amp 3 Weeks 4 586 Pr Wounds Tissue repair Weeks 2 amp 3 Weeks 4 586 Hormonal imbalance weeks ff Immune Auto immune sweets ff Boost immune system Lawes ff Undiagnosed lameness sweets ff Behavioural problems ECC fff Competition Travelling to After event Travelling home r Maintenance 1 week amp Prevention every month Or until sound at walk whichever is the longer Selecting treatment programme First choose the treatment programme you wish to deliver see quide on page 6 If you are not treating a specific condition but using ArcEguine as part of a maintenance and prevention regime we recommend that you first go through Standard initiation programmes 1 2 and 3 Programming the unit At the top of the unit there are four treatment programme
3. LED s To select your treatment programme press the left hand button and cycle through the LED s until the chosen treatment programme is lit Once the treatment programme has been selected you will hear a sequence of short sharp beeps The number of beeps indicates the treatment programme selected For example Three beeps Programme three If the unit has already been used the red LED will indicate the last treatment programme delivered Activating the programme Once the desired treatment programme has been selected press the right hand button once and the unit will begin delivery of the treatment Once activated the left hand button will turn off and the right hand button and programme indicator will turn either Green To indicate complete connectivity Red To indicate no connectivity at one or more of the ArcPads After 30 seconds the right hand button will turn off and the programme indicator will begin to flash and continue to do so throughout the delivery period Leg strap and unit in position Attach strap with the unit positioned to the side of the cannon bone Do not strap to an injured leg Do not over tighten Rotate leg strap between sound legs each day Troubleshooting If the programme indicator has changed from green to red during the treatment and The left hand button has lit up red This indicates that there is insufficient power in the battery to complete delivery of the selected
4. beep to indicate that the unit is now in sleep mode Note The unit is supplied with the Audible Beep Alert on If you require this function turned off go to page 5 Quick start guide 1 2 3 4 5 6 7 8 9 Make sure your delivery unit is fully charged Page 3 Attach ArcPads to leg strap using press studs Turn the unit on Page 5 Select desired treatment programme Pages 6 7 Activate programme Page 7 Connect unit to leg strap Page 8 Secure unit to leg strap using the elasticated bands Page 8 Add a small amount of gel onto each ArcPad Attach the leg strap ensuring the spine of the strap with unit runs vertically along the side of the cannon bone Page 8 10 To protect the unit we advise that you cover with a stable boot or bandage Note See page 9 for further important information Treatment programme indicators How to turn the unit on Press and hold the left hand button for four seconds you will then hear a high pitched beep and the button will light either green or red Indicates the unit is fully charged and ready to use Indicates unit needs charging How to turn the unit off Press and hold the left hand button After two seconds you will hear a confirmation beep The light within the button will then turn off Turning Audible Beep Alert on and off Ensure the unit is turned on Press and hold both buttons at the same time After three seconds you will hear three short beeps
5. for use specifically as directed on horses Applied Microcurrent Technology Equine Limited its distributors employees agents or directors are not responsible for liability or consequential losses from incorrect or inappropriate use arceQUINE enquiries arcequine com www arcequine com
6. often no scar tissue Leg straps arceqauine Delivery unit Conductive gel ArcPads User manual Unit charger f What s in the box 1 x Delivery unit 2 x Leg straps with press studs 4 x Carbon rubber ArcPads 1 x Conductive gel 250ml 1 x Unit charger 1 x User manual The ArcPads have been specifically designed for durability comfort and connectivity They are fixed to the leg strap with press studs The conductive gel has been specifically formulated for use with ArcEquine The contents comply with all equine and veterinary regulations and requirements Use of gel enables electrical connectivity from the ArcPad through the hair to the skin of the horse Registering your ArcEquine Please ensure you register your ArcEquine warranty at www arcequine com Charging the Delivery unit Only use the unit charger supplied Insert the charger into the base of the unit then plug in the charger and switch on When the charger is inserted you will hear two short beeps and the left hand button will indicate Red Still charging Amber Nearly charged Green Fully charged and ready for use After 30 seconds the button will begin to flash and will continue to do so until the unit is fully charged When the left hand button has turned green your unit is fully charged and can be unplugged When your unit is unplugged you will hear a
7. treatment OT The right hand button has lit up red This indicates a loss of connectivity Either the lead has become disconnected or one or Doth of the ArcPads are not making a good enough connection to the skin to complete the circuit Should you require any assistance contact support arcequine com Important information Protect your ArcEquine from wet and damp conditions it is not waterproof The use of microcurrent technology can cause some dehydration Please ensure your horse always has access to clean fresh water when using the ArcEquine unit Use of ArcEquine is in addition to and in no way a substitute for your existing veterinary policy and practice A pdf of this manual along with further information is available on our website www arcequine com Don t forget to register your ArcEquine warranty at www arcequine com Disclaimers ArcEquine statements are based on feedback from users and field trials supervised by qualified clinicians not clinical trials by approved regulatory bodies Patents are pending for human use The products are evolving and in the stage of product testing and feasibility studies Until full regulatory body approval is granted all user testing is the responsibility of the users without liability to ArcEquine Users are responsible for full reading and understanding of this user manual and correct and complete application of the equipment manual instructions ArcEguine is only