INSTALLATION MANUAL for ZSC-1000 and ZSC
Contents
1. Baud Rates The site controller will communicate with other site controllers at various baud rates Baud rate Usage 9600 Small installations 19200 gt 8 sites 38400 As required 57600 As required Turnaround Time Turnaround time is the time taken for transmission equipment to finish receiving data before it starts transmitting Similarly the time taken from finishing transmission to when it goes high impedance For connecting to 3 party transmission equipment our referenced turnaround time should be treated as their maximum turnaround i e 3 party must be faster than Meyertech On some equipment the minimum turnaround time is determined by baud rate i e if the site controller is running at a slow baud they must not have too fast a turnaround as it could turn mid bit Note firmware version from 3 20 0 0 onwards have configurable turnaround times defaulting to 4ms Baud rate Turnaround time ms 9600 4 19200 3 38400 2 57600 1 RS485 Interface e RS485 2 wire e Half duplex e 2 connectors provided to assist daisy chaining e _ Un terminated e _ Un biased e Pre biasing can be achieved by using the 750R pull up resistor provided on pin 8 on the Intersite Out port in conjunction with an external not provided 750R pull down resistor connected to the Ov connection on pin 5 av PING PIN H Whilst every effort has been
2. 6 earth pop gt Mercury 3 ZSC 1000 interconnection diagram SITE IN SITE OUT ZVR2 ZVR3 ZVR 4 9 way D type 9 way D type 9 way D type 9 way D type 6 way 6 way 6 way 6 way female female male female 2 part 2 part 2 part 2 part MEYERTECH LIMITED OFFICE BLOCK ONE SOUTHLINK BUSINESS PARK OLDHAM OL41DE TEL 0161 628 8406 Drwg No 9 zsc 1000 manual doc Whilst every effort has been made to confirm the information in this document is correct MEYERTECH LIN or any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means withc YERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Issue 04 Page 7 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk Intersite Requirements Supported Sites The site controller can connect to a large number of remote sites Remote Site ZSC 1000 ZSC 1000plus Peer peer Direct connection 16 16 99 Simplex Direct connection 99 99 Dialup connection 99 99 Total sites 99 99 limitations when running in simplex mode contact Meyertech for further details dependent on firmware version
3. SK Meyers S K MEYERS Managing Director Meyertech Limited SIGNED ISSUED THIS DAY 20 July 2000 Meyertech Limited Office Block One Southlink Business Park Oldham England OL4 1DE Whilst every effort has been made to confirm the information in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Issue 04 Page 9 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk PRODUCT WARRANTY MEYERTECH UMITED warrants that at the time of shipment the products manufactured by Meyertech will be free from defects in material and workmanship Should any defects appear within twelve months from date of shipment Meyertech shall at it s sole discretion repair or replace the defective material Such material shall not be accepted for return or repair without prior notification of Meyertech Return shipments to Meyertech shall be at the customer s expense Meyertech will return said equipment prepaid via best way This warranty is in lieu of and excludes any and all other
4. expressed or implied warranties of merchantability or fitness or otherwise Items manufactured by any supplier other than Meyertech shall bear only the warranty made by the manufacturer of that product and Meyertech assumes no responsibility for the performance or reliability of that product Meyertech will not be liable for any special or consequential damages or for loss damages or expense directly or indirectly arising from the use of the products or any inability to use them either separately or in combination with any other equipment or material or from any other cause This warranty does not extend to any product manufactured by Meyertech which has been subject to misuse neglect accident war civil disturbance terrorist acts improper installation act of God or in violation of the instructions supplied by Meyertech Whilst every effort has been made to confirm the information in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED
5. ZSC 1000 Installation Manual Issue 04 Page 1 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk MEYERTECH SECURITY with VISION MEYERTECH UMITED Zebra Court White Moss View Greenside Way Manchester M24 1UN Tel 44 0 161 643 7956 Fax 44 0 161 628 9811 Email tech supportsupport meyertech co uk http www meyertech co uk INSTALLATION MANUAL for TM ZSC 1000 and ZSC 1000plus SITE CONTROLLER Whilst every effort has been made to confirm the information in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Issue 04 Page 2 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk CONTENTS CONTENTS ZSC 1000 INTRODUCTION ZoneVu ZSC XXXX CONNECTING THE ZSC 1000 Unpacking Recommended Cable Connector Table Connection Diagram Intersite Requirements PRODUCT WARRANTY Se JN un bk A A KR Y W hn Whilst every effort has been made to confirm the informat
6. he ZSC 1000 and ZSC 1000plus have the same external connections and are installed in an identical manner SYSTEM PARAMETER Local ZoneVu Ports Remote ZoneVu Ports Local 3 Party Control Ports Remote 3 Party Control Ports Intersite ZoneVu Ports Local Cameras Local Monitors Local Keyboards GUls Local Peripherals Local Alarm Events Local Sequences Intersite Video Intersite Camera Control Intersite Capabality ZSC 1000 SUPPORT 3 ZVM ZVK PC2 4 ZVR1 ZVR2 ZVR3 ZVR4 1 PC1 4 ZVR1 ZVR2 ZVR3 ZVR4 2 Intersite In Intersite Out Export and Import Export and Import Full peer to peer ZSC 1000plus SUPPORT 3 ZVM ZVK PC2 4 ZVR1 ZVR2 ZVR3 ZVR4 1 PC1 4 ZVR1 ZVR2 ZVR3 ZVR4 2 Intersite In Intersite Out 4096 2048 32 90 500 32 Export and Import Export and Import Full peer to peer Intersite Input Trunks 384 Intersite Output Trunks 39 128 Timed events 100 128 Information regarding other Meyertech products and technical information can be found at our website http www meyertech co uk Whilst every effort has been made to confirm the information in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to contin
7. ion in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Support Tel 44 0 161 6437956 Issue 04 email tech support meyertech co uk ZSC 1000 INTRODUCTION Thank you for purchasing the ZoneVu ZSC 1000 System Site Controller ZoneVu ZSC XXXX Page 3 of 9 www meyertech co uk As the name suggests the ZoneVu System Site Controller product family are responsible for co ordinating communications at each site Currently three variants are available each having a different level of specification the ZSC 500 ZSC 1000 and ZSC 1000plus models which offer third party control interfaces remote site access and local site control full peer to peer intersite access comprehensive system backup and audit facilities and on line remote support when connected to a PC GUI The ZSC 1000s are the flagship products of the ZoneVu Site Controller family They differentiate themselves from the other family member products through their INTERSITE capabilities which are Peer to Peer and their System Support T
8. made to confirm the information in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Issue 04 Page 8 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk EC DECLARATION OF CONFORMITY ACCORDING TO ARTICLE 10 OF COUNCIL DIRECTIVE 89 336 EEC Manufacturer MEYERTECH LIMITED Address Meyertech Limited Office Block One Southlink Business Park Oldham OL4 1DE Declares that the product s Product Code ZSC 1000 System Site Controller Model s All Product Options All conforms to the following Product Specifications EN55022 CLASS B EN50093 EN60950 Amendments 1 2 amp 3 1992 Supplementary Information MEYERTECH declare under our sole responsibility that the product to which this declaration relates is in conformity with the protection requirements of council directive 89 336 eec on the approximation of the laws of the member states relating to electromagnetic compatibility when installed in accordance with the instructions given in this manual
9. r RS485 ZVR2 6 way 2 part CAMERA CONTROL 2 RS422 or RS485 ZVR3 6 way 2 part CAMERA CONTROL 3 RS422 or RS485 ZVR 4 6 way 2 part CAMERA CONTROL 4 RS422 or RS485 PSU FUSE NONE POWER FUSE 1A Anti surge FUSE not fitted on newer models Whilst every effort has been made to confirm the information in this document is correct MEYERTECH LIMITED cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH LIMITED MEYERTECH LIMITED is committed to continuous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Issue 04 Page 5 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk Connection Diagram ZSC 1000 rear view connectors RS232 RS232 01 first release 10 07 00 2 Rx 2 Rx 3 Tx 3 Tx 5 Gnd 5 Gnd RS485 RS485 Frame earth Frame earth 3 RxTx 3 Rx Tx 4 Rx Tx 4 Rx Tx 5 Gnd 5 Gnd Frame earth 8 5V Frame earth RS422 1 Rx 2 Rx RS422 485 RS422 485 RS422 485 RS422 485 3 Gnd 1 Rx Tx 1 RwTx 1 RxTx 1 Rx Tx 4 Tx 2 Rx Tx 2 Rx Tx 2 RxTx 2 Rx Tx 5 Txt 3 Gnd 3 Gnd 3 Gnd 3 Gnd 6 earth 4 Tx 4 Tx 4 Tx 4 Tx 5 Tx 5 Tx 5 Tx 5 Tx 6 earth 6 earth 6 earth
10. uous product development and therefore reserves the right to change specifications without notice 2000 14 ALL RIGHTS RESERVED ZSC 1000 Installation Manual Issue 04 Page 4 of 9 Support Tel 44 0 161 6437956 email tech support meyertech co uk www meyertech co uk CONNECTING THE ZSC 1000 To obtain the optimum performance from your ZSC 1000 Site Controller please take time to read this manual before commencing installation If you have any questions or problems our staff will be pleased to assist you on our support line TEL 44 0 161 643 7956 Unpacking Unpack the ZSC 1000 and check the contents against the list below 4 ZSC 1000 1u 19 inch Euro enclosure 4 Power Supply 12V Connect up the ZSC 1000 in accordance with diagram shown Looking at the back of the rack pin number one is on the left on the 2 part 6 way connectors of the ZVM ZVK and ZVR ports Recommended Cable RS422 Half Duplex connections Beldon 2 pair 9842 or 9502 RS485 Half Duplex connections Beldon 1 pair 8761 RS422 Simplex connections Beldon 1 pair 8761 Connector Table NAME CONNECTOR FUNCTION TYPE POWER 12V power jack POWER INPUT POWER SITE IN 9 way D type plug INTERSITE COMMS RS485 SITE OUT 9 way D type socket INTERSITE COMMS RS485 PC 1 9 way D type plug PC CONTROL 1 RS232 PC 2 9 way D type plug PC CONTROL 2 RS232 ZVM 6 way 2 part MATRIX NETWORK RS422 ZVK 6 way 2 part KEYBOARD NETWORK RS422 ZVR 1 6 way 2 part CAMERA CONTROL 1 RS422 o