SMA SPEEDWIRE/WEBCONNECT DATA MODULE

image

Contents

1. 2 1 Appropriate 2 2 Qualifications of Skilled Persons 2 3 Safety Precautions 2 4 Operating 5 5 25 SD Upponea Produits 3 iScope of Delivery eserse adi s Product Description 4 1 Speedwire Webconnect Data Module 42 teu teda Cea ice 13 Cable Old ua sire Sot ien eh 9 CONNECHON iio ee Ee doi iei Gea tea Une e Genes 5 1 Mounting Position and Cable Route 5 2 Cable Requirements and Information on Cable Routing 5 3 Installing the Speedwire Webconnect Data Module 5 4 Connecting the Speedwire Webconnect Data Module 6 COMMISSIONING oues esit di ED ROI 6 1 Commissioning a Large Scale Plant with Cluster Controller 6 2 Commissioning a Small Scale Plant 6 3 Managing a Small Scale Plant with Sunny Explorer 6 3 1 Functions and Parameter Settings in Sunny Explorer 6 3 2 Creating a Small Scale Plant Sunny 6 4 Plant Registration in Sunny 6 4 1 Registering a Large Scale Plant with Cluster Controller in Sunny os 6 4 2 Registering a Small Scale Plant Sunny Portal Installation Manual SWWEBC
2. 10 Stick one the labels with the data for registration in Sunny Portal PIC and RID on the outside of the inverter in the vicinity of the type label 11 If you do not wish to proceed immediately with the connection of the Speedwire Webconnect data module close the inverter see inverter installation manual 5 4 Connecting the Speedwire Webconnect Data Module Depending on the plant topology you require you must connect either one or two cables to the Speedwire W ebconnect data module Requirement The network cables must be pre assembled according to the plant topology and the cable requirements see Section 5 2 page 20 Additionally required material not included in scope of delivery Network cable see Section 5 2 Cable Requirements and Information on Cable Routing page 20 Procedure 1 A DANGER Danger to life due to electric shock when the inverter is opened High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury e Ifthe inverter has not yet been opened disconnect the inverter from voltage sources the AC and DC sides and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Flip the display up until it clicks into place 3 Unscrew the swivel nut of the cable gland on the inverter Installation Manual SWWEBCONDM lA en 13 23 5 Connection
3. Installation Manual SMA SPEEDWIRE WEBCONNECT DATA MODULE SWWEBCONDM lA en 13 Version 1 3 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Manufacturers Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All trademarks are recognised even if these are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by SMA Solar Technology AG is under licence GR Code is a registered trademark of DENSO WAVE INCORPORATED SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E mail info SMA de 2004 to 2013 SMA Solar Technology AG All rights reserved 2 SWWEBCONDM lA en 13 Installation Manual SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document oooooooo o 2 Saey
4. SMA Solar Technology AG 4 19 NP 12 13 14 13 24 Press the seal out of the cable gland from the inside Lead the network cables from the outside into the inverter through the loose swivel nut and the cable gland For each network cable remove one of the filler plugs from the seal and retain for later decommissioning y Lead the network cables through the swivel nut and into the seal Route the network cable plugs into the inverter to the network sockets Push the seal into the cable gland Make sure that any unused cable openings are sealed with filler plugs Screw the swivel nut of the cable gland on lightly Insert the network cables into the network sockets This can be done in any order Fasten the swivel nut on the cable gland hand tight This will secure the network cables in place Flip the display down and fasten it hand tight with the display screw Close the inverter see inverter installation manual In a small scale plant connect at least one inverter directly to the router using a network cable depending on the plant topology In a large scale plant with Cluster Controller connect the Cluster Controller to the Speedwire network in accordance with the required network topology see the Cluster Controller installation manual SWWEBCONDM IA en 13 Installation Manual SMA Solar Technology AG 6 Commissioning 6 Commissioning 6 1 Commissioning a Large Scale Plant with Cluster Cont
5. the inverters with the Speedwire Webconnect data module into your network see Section 2 5 Supported Products page 11 Procedure l 2 Commission all inverters see inverter installation manual For plants in Italy in order to adjust the settings to receive control signals from the network operator in the Speedwire Webconnect data module follow the steps below Connect with Sunny Explorer see Section 6 3 2 page 27 Enter your personal SMA Grid Guard code in Sunny Explorer see Sunny Explorer help Setthe following parameters in Sunny Explorer for setting parameters in a device see Sunny Explorer help Installation Manual SWWEBCONDM IA en 13 25 6 Commissioning SMA Solar Technology AG External Communication gt IEC 61850 configuration Parameter Value Range Resolution Default Application ID O to 16384 1 16384 Goose Mac address 01 0C CD 01 00 00 1 01 0C CD 01 00 00 to 01 0C CD 01 02 00 e In the field Application ID set the Application ID of the network operator gateway You will receive this value from your network operator You can enter a value between O and 16384 The value 16384 indicates deactivated In the field Goose Mac address enter the MAC address of the network operator gateway from which the Speedwire Webconnect data module 15 to receive the control commands You will receive this value from your network operator V The receipt of network operator control signals has been set 6
6. 00 m and 1 000 m 5 3 Installing the Speedwire Webconnect Data Module 1 9 Danger to life due to electric shock when the inverter is opened High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury e Disconnect the inverter from voltage sources on the AC and DC sides and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge Loosen the screw of the display until the display can be flipped up Flip the display up until it clicks into place Installation Manual SWWEBCONDM A en 13 21 5 Connection SMA Solar Technology AG 4 Push the pre mounted filler plug out of the second hole from the left in the inverter enclosure and retain it for future decommissioning 5 Attach the cable gland to the enclosure opening using the counter nut 6 Insert the Speedwire Webconnect data module y a gt me and slide the ribbon cable upwards behind the display The key on the edge of the Speedwire Webconnect data module must fit into the hole in the plastic retainer in the inverter 7 Fasten the Speedwire W ebconnect data module hand tight with the hexagon socket screw AF 3 8 Flip the display down 22 SWWEBCONDM IA en 13 Installation Manual SMA Solar Technology AG 5 Connection 9 Plug the ribbon cable plug onto the centre connector strip
7. 3 Managing a Small Scale Plant with Sunny Explorer 6 3 1 Functions and Parameter Settings in Sunny Explorer The following functions for plant management in Sunny Explorer are available Overview of the plant status Graphic display of key plant data device data and energy values e Parameterisation of individual devices or an entire device class Simple diagnostics through display of faults and events e Data export of inverter energy values and events in CSV format e Device updates You can change the following parameters in Sunny Explorer Device name of the inverter e Automatic IP configuration On Off e DNS IP gateway IP IP address subnet mask Webconnect function On Off 26 SWWEBCONDM A en 13 Installation Manual SMA Solar Technology AG 6 Commissioning 6 3 2 Creating a Small Scale Plant Sunny Explorer Requirements The plant must be commissioned see Section 6 2 page 25 Sunny Explorer must be installed on the computer see Section 2 5 Supported Products page 11 Procedure 1 Connect the computer to the plant router using a network cable 2 If you have used the SMA Connection Assist for the static network configuration ensure that the SMA Connection Assist has ended 3 Start Sunny Explorer and create a Speedwire plant for the small scale plant in Sunny Explorer see Sunny Explorer help 6 4 Plant Registration in Sunny Portal 6 4 1 Registering a Large Scale Plant with Cluster Controller in Sunny Port
8. Africa United Kingdom HA 97 2 698 5080 Other countries Siehe Deutschland pozri Cesko Cesk republika SMA Solar Technology South Africa Pty Ltd Centurion Pretoria SMA Solar UK Ltd Milton Keynes SMA Hellas AE AOrnva EMa a SMA Solar Thailand Co Ltd NUNN SMA Technology Korea Co Ltd N SMA Beijing Commercial Company Ltd ACR SMA Japan K K International SMA Service Line Niestetal 34 SWWEBCONDM IA en 13 SMA Middle East LLC SMA Solar Technology AG 08600 SUNNY 08600 78669 International 44 1908 304899 27 12 643 1785 801 222 9 222 30 212 2229 222 International 66 2 670 6999 82 2 508 8599 86 10 5670 1350 81 33451 9530 e Lay sasidll du Toll free worldwide 00800 SMA SERVICE 800 762 7378423 Installation Manual SMA Solar Technology
9. ONDMM A en 13 Table of Contents SMA Solar Technology AG 7 DECOMMISSIONING iii dic 29 7 1 Removing the Speedwire Webconnect Data Module 29 7 2 Packaging the Speedwire Webconnect Data Module for Shipping 29 7 3 Disposing of the Soeedwire Webconnect Data Module 29 8 30 9 Technical Dalai tomos oa Sorte 31 10 CONTIG uos chia he AAA 32 4 SWWEBCONDM A en 13 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This document is valid for device type SWDM 10 GR1 Speedwire Webconnect data module from hardware version A and firmware version 1 00 1 1 R Target Group This document is for skilled persons Only persons with the appropriate skills are allowed to perform the tasks described in this manual see Section 2 2 page 8 Additional Information Links to additional information can be found at www SMA Solar com Document title Document type Firmware Update with SD Card Technical description Symbols Symbol Explanation DANGER Indicates hazardous situation which if not avoided will result in death serious injury serious injury A CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which if not avoided could result in property damage Information that is important for a spec
10. ace via the individual inverters but centrally via the Cluster Controller see user manual of the Cluster Controller and user manual of the Cluster Controller in Sunny Portal i Deactivation of the Webconnect function of inverters in large scale plants with Cluster Controller In large scale plants with Cluster Controller communication with Sunny Portal takes place via the Cluster Controller itself e For optimum operation of large scale plants with Cluster Controller deactivate the Webconnect function of the inverters with installed Speedwire Webconnect data module see user manual of the Cluster Controller f eD amo ll A A A A GQ GP GP GD Figure 7 Large scale plant with Cluster Controller and inverters in linear topology example Item Designation A Inverter with Speedwire Webconnect data module Cluster Controller Router Internet Sunny Portal Computer with access to the user interface of the Cluster Controller Installation Manual SWWEBCONDM IA en 1 3 17 4 Product Description SMA Solar Technology AG 4 2 Type Label The type label clearly identifies he product The type label is located in the righthand top corner on the front of the product You will find the following information on the type label e Device type Type e Serial number Serial No e Hardware version Version e PIC e RID e address You will require the information on the type label to use the product safel
11. al Requirements The large scale plant with Cluster Controller must be commissioned see Section 6 1 page 25 Ll Your computer must have an Internet connection The Cluster Controller must be connected to a router with Internet connection see installation manual of the Cluster Controller JavaScript must be activated in the Internet browser Procedure e In large scale plants with Cluster Controller register in Sunny Portal using the user interface of the Cluster Controller see user manual of the Cluster Controller Installation Manual SWWEBCONDM lA en 13 27 6 Commissioning SMA Solar Technology AG 6 4 2 Registering a Small Scale Plant in Sunny Portal Requirements The small scale plant must be commissioned see Section 6 2 page 25 PIC and RID must be available for the Speedwire Webconnect data module Your computer must have an Internet connection JavaScript must be activated in the Internet browser In Sunny Portal a maximum of four inverters with installed Speedwire Webconnect data module is permitted per small scale plant O O i Maximum permissible number of devices for a small scale plant in Sunny Portal Small scale plant with Speedwire Webconnect data module cannot be combined with other plants IF you already have a plant with a different communication device e g Sunny WebBox in Sunny Portal you will still need to create a separate small scale plant with Speedwire Webconnect data m
12. and the DC connectors form a DC load disconnect unit IP Internet Protocol PIC Product Identification Code Identification key for registration in Sunny Portal RID Registration Identifier Registration key for registration in Sunny Portal AF Width Across Flats The distance between two parallel flat surfaces flats of a screw head UMTS Universal Mobile Telecommunications System succeeding GSM System Figures The figures in this document have been created for inverters of type Sunny Boy and may deviate slightly in some cases for inverters of type Sunny Tripower Installation Manual SWWEBCONDM A en 13 7 2 Safety SMA Solar Technology AG 2 Safety 2 1 Appropriate Usage The Speedwire Webconnect data module is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimised 10 100 Mbit data transmission between Speedwire devices PV plants The Webconnect function enables direct data transmission between the inverters of a small scale plant and the Internet portal Sunny Portal without any additional communication device and for a maximum of four inverters per Sunny Portal plant For this a Speedwire Webconnect data module must be installed in each of the inverters You can access your Sunny Portal plant from any computer with an Internet connection The Speedwire Webconne
13. at the UMTS provider also provides the VoIP service 10 SWWEBCONDM A en 13 Installation Manual SMA Solar Technology AG 2 Safety 2 5 Supported Products SMA Inverters The Speedwire Webconnect data module may only be installed in the following inverters with at least firmware version 2 53 Sunny Boy Sunny Tripower e SB 2500TLST 21 e STP 8000TL 10 e B 3000TLST 21 e STP 10000TL 10 e SB 3000TL 21 e STP 12000TL 10 e SB 3600TL 21 e STP 15000TL 10 e SB 4000TL 21 e STP 15000TLEE 10 e SB 5000TL 21 e STP 15000TLHE 10 e STP 17000TL 10 e STP 20000TLEE 10 e STP 20000TLHE 10 If the firmware version of the inverter is lower than 2 53 you must perform a firmware update to version 2 53 or higher for this inverter For information on performing the firmware update refer to the Technical Description Firmware Update with SD Card at www SMA Solar com Additional SMA products e SMA Cluster Controller from firmware version 1 0 e Sunny Explorer from software version 1 06 e SMA Connection Assist from software version 1 00 8 R Sunny Explorer and SMA Connection Assist are available free of charge at www SMA Solar com Installation Manual SWWEBCONDM lA en 13 11 3 Scope of Delivery SMA Solar Technology AG 3 Scope of Delivery Check the scope of delivery for completeness and any visible external damage Contact your specialist dealer if the delivery is incomplete or damaged Order Option Speedwire Webconnect Data Module Pre Installed in t
14. ct data module performs the following tasks e Setup of a Speedwire network in small scale and large scale plants Data exchange with Sunny Portal n small scale plants via a router with Internet connection In large scale plants via the Cluster Controller e Data exchange with Sunny Explorer from version 1 06 For PV plants in Italy Connection to or isolation from the electricity grid and definition of the frequency limits to be used with IEC61850 GOOSE messages The Speedwire Webconnect data module is available as a retrofit kit or is pre installed in the inverter For safety reasons it is not permitted to modify the product or install components that are not explicitly recommended or distributed SMA Solar Technology AG for this product Only use the Speedwire Webconnect data module in accordance with the specifications provided in the enclosed documentation Any other use may result in personal injury or property damage The enclosed documentation 15 an integral part of this product Read and observe the documentation Keep the documentation in a convenient place for future reference 2 2 Qualifications of Skilled Persons The work described in this document must be performed by skilled persons only Skilled persons must have the following qualifications Training in the installation and commissioning of electrical devices and plants Knowledge of how to deal with the dangers and risks associated with installing a
15. d and with the ESS plugged in the inverter has the degree of protection IP65 The inverter is thus protected against dust intrusion and water penetration Dust intrusion and water penetration can damage the inverter When the ESS is not plugged in measures must be taken to protect the inverter against dust and water e Firmly plug in the ESS again after performing any work on the inverter Damage to the inverter due to electrostatic discharge The internal components of the inverter can be irreparably damaged by electrostatic discharge e Earth yourself before touching any inverter components Installation Manual SWWEBCONDM A en 13 9 2 Safety SMA Solar Technology AG 2 4 Operating Instructions NOTICE High costs possible due to inappropriate Internet rates When using the Webconnect function a constant Internet connection is required Depending on the quality of the Internet connection the data transfer volume for an inverter is between 150 MB and 550 MB per month When using the plant overview in Sunny Portal with live data display there is an additional data volume of 600 kB per hour e Since there is a constant Internet connection to Sunny Portal time based billing systems should be avoided High costs could be incurred SMA Solar Technology AG recommends using an Internet flat rate i If UMTS is used VoIP is required IF UMTS is used VoIP Voice over IP is required to use the Webconnect function e Ensure th
16. data module In small scale plants the Speedwire network can be set up optionally with linear star or tree topology Depending on the plant the computer with the Sunny Explorer software will be connected to the router or the network switch Figure 4 Small scale plant with two inverters in linear topology example Item Designation Inverter with Speedwire Webconnect data module B Router Internet D Sunny Portal E Computer with Sunny Explorer 14 SWWEBCONDM lA en 13 Installation Manual SMA Solar Technology AG 4 Product Description Figure 5 Small scale plant with two inverters in star topology example Item Designation A Inverter with Speedwire Webconnect data module B Router Internet D Sunny Portal E Computer with Sunny Explorer Installation Manual SWWEBCONDM lA en 13 15 4 Product Description SMA Solar Technology AG Figure 6 Small scale plant with four inverters in tree topology example ltem Designation A Inverter Network switch Router Internet Sunny Portal Computer with Sunny Explorer 16 SWWEBCONDM lA en 13 Installation Manual SMA Solar Technology AG 4 Product Description Use in Large Scale Plants with Cluster Controller The Speedwire network can be set up optionally with linear or tree topology In large scale plants with Cluster Controller the data exchange with Sunny Portal does not take pl
17. e of the Speedwire Webconnect data module in accordance with the regulations for the disposal of electronic waste applicable at the site of installation Installation Manual SWWEBCONDM lA en 13 29 8 Troubleshooting SMA Solar Technology 8 Troubleshooting Problem Cause and corrective measures The Speedwire Webconnect There is no Speedwire connection data module cannot be Corrective measures accessed e Ensure that all network cable plugs are inserted and locked e Ensure that all inverters in the plant are in operation Make sure that the plant router is switched on Make sure that the ribbon cable plug of the Speedwire Webconnect data module is correctly plugged into the centre connector strip in the inverter The inverter does not recognise the Speedwire Webconnect data module Corrective measures e Perform a firmware update on the inverter see Technical Description Firmware Update with SD Card at www SMA Solar com Firewall or IP filter settings are not correct Corrective measures e Adjust firewall or IP filter settings see firewall or router manual The Speedwire Webconnect data module does not have a valid IP address Corrective measures e Ensure that DHCP is activated in the router or assign a manual IP address to the Speedwire Webconnect data module 30 SWWEBCONDM A en 13 Installation Manual SMA Solar Technology AG 9 Technical Data 9 Technical Data General Data Mounting l
18. ect on the signal quality Observe the following cable requirements and the note on laying them i Disturbance of data transmission due to unshielded power cables IF unshielded power cables are used they generate an electromagnetic field which may induce interference in network cables during data transmission When laying network cables observe the following minimum clearances to unshielded power cables Forinstallation without separating strip at least 200 mm Forinstallation with aluminium separating strip at least 100 mm For installation with steel separating strip at least 50 mm 20 SWWEBCONDM IA en 13 Installation Manual SMA Solar Technology AG 5 Connection Cable requirements O 000 UV resistant for outdoor use Number of insulated wire pairs and insulated wire cross section at least 2 x 2 x 0 22 mm or at least 2 x 2 AWG 24 External diameter of the cable the maximum external diameter of the cable depends on the size of the cable gland included in the delivery Cable category Cat5 Cat5e Cat Cat7 Cable shield SF UTP S UTP SF FTP S FTP Plug type RJ45 for Cat5 Cat5e Cat Cable length between two nodes max 50 m with patch cable max 100 m with installation cable SMA Solar Technology AG recommends the following cable types For outdoor use SMA COMCAB OUTxxx For indoor use SMA COMCAB INxxx The cables are available in the lengths xxx 100 m 200 m 5
19. he Inverter A B C Figure 1 Components of the order option Speedwire Webconnect data module pre installed in the inverter Item Number Designation 1 Installation manual B 1 Cable gland 1 Label with PIC and RID for registration of a small scale plant in Sunny Portal Order Option Speedwire Webconnect Data Module as Retrofit Kit Figure 2 Components of the order option Speedwire Webconnect data module as retrofit kit Number Designation A 1 Speedwire Webconnect data module SWDM 10 B 1 Installation manual 1 Cable gland D 2 Label with PIC and RID for registration of a smallscale plant Sunny Portal 12 SWWEBCONDM IA en 13 Installation Manual SMA Solar Technology AG 4 Product Description 4 Product Description 4 1 Speedwire Webconnect Data Module The Speedwire Webconnect data module is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimised 10 100 Mbit data transmission between Speedwire devices in PV plants The Webconnect function enables direct data transmission between the inverters of a small scale plant and the Internet portal Sunny Portal without any additional communication device and for a maximum of four inverters per Sunny Portal plant For this a Speedwire Webconnect data module must be installed in each of the
20. ific topic or goal but is not safety relevant Indicates an essential requirement for achieving a specific goal Desired result x RD I A problem that might occur Installation Manual SWWEBCONDM A en 13 B 1 Information on this Document SMA Solar Technology AG The value can be read from the Energy field Select Settings Enter the value 10 in the Minutes field Select Settings gt Date Select Next Speedwire Webconnect data module Typography Typography Explanation Example bold e Display texts e e Elements of a user interface e Terminals e Elements to be selected e Elements to be entered gt e Connects several elements to be selected Button Key e Button or key to be selectedor pressed Nomenclature Full designation Designation in this document PV plant Plant Small scale PV plant Small scale plant Large scale PV plant Large scale plant SMA Cluster Controller Cluster Controller SMA Speedwire Speedwire SMA Speedwire Webconnect data module SMA Webconnect function Webconnect function SMA inverter 6 SWWEBCONDM A en 1 3 Inverter Installation Manual SMA Solar Technology AG 1 Information on this Document Abbreviations Abbreviation Designation Explanation AC Alternating Current DC Direct Current DHCP Dynamic Host Configuration Protocol Protocol for the dynamic assignment of IP configurations ESD Electrostatic Discharge ESS Electronic Solar Switch The Electronic Solar Switch
21. inverters You can access your Sunny Portal plant from any computer with an Internet connection The Speedwire Webconnect data module performs the following tasks e Setup of a Speedwire network in small and large scale plants Data exchange with Sunny Portal n small scale plants via a router with Internet connection In large scale plants via the Cluster Controller Data exchange with Sunny Explorer from software version 1 06 The Speedwire Webconnect data module is available as a retrofit kit or is pre installed in the inverter Figure 3 Components of the Speedwire Webconnect data module Item Designation A Hexagon socket screw AF 3 Network socket A Network socket B Ribbon cable plug Ribbon cable Type label Installation Manual SWWEBCONDM A en 13 13 4 Product Description SMA Solar Technology AG Label with PIC and RID for Registration of a Small Scale Plant in Sunny Portal To activate the Speedwire Webconnect data module of a small scale plant Sunny Portal you will need the PIC and RID numbers printed on the label included in the delivery After installation of the Speedwire Webconnect data module attach the label on the exterior of the inverter in the vicinity of the type label Keep the other label in a safe place for future reference Use in Small Scale Plants with a Maximum of Four Inverters A small scale plant Sunny Portal can consist of a maximum of four inverters with installed Speedwire Webconnect
22. nd using electrical devices and plants Knowledge of all applicable standards and directives Knowledge of how an inverter works and is operated Knowledge of and adherence to this document and all safety precautions 8 SWWEBCONDM IA en 13 Installation Manual SMA Solar Technology AG 2 Safety 2 3 Safety Precautions This section contains safety precautions that must be observed at all times when working on or with the product To prevent personal injury or property damage and to ensure long term operation of the product read this section carefully and comply with the safety precautions at all times DANGER Danger to life due to electric shock when the inverter is opened High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury e Prior to performing any work on the inverter always disconnect the inverter from all voltage sources on the AC and DC sides see inverter installation manual Observe the waiting time to allow the capacitors to discharge CAUTION Risk of burns due to hot enclosure parts Some parts of the inverter enclosure can get hot during operation Touching these enclosure parts can result in burn injuries Do not touch any parts other than the lower enclosure lid of the inverter during operation NOTICE Risk of damage to the inverter through dust intrusion or moisture penetration if the ESS is not plugged in When close
23. nductive components of the inverter Touching live components results in death or serious injury e Disconnect the inverter from voltage sources on the AC and DC sides and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Press the left hand and right hand lock hooks outwards and remove the ribbon cable plug from the centre connector strip of the inverter 3 Loosen the screw of the display until the display can be flipped up Flip the display up until it clicks into place Unscrew the swivel nut of the cable gland Remove the network cables from the Speedwire Webconnect data module Unscrew the counter nut of the cable gland Remove the cable gland and network cables from the inverter Release the hexagon socket screw of the Speedwire Webconnect data module 3 and remove the module 10 Flip the display down and fasten the display screw hand tight 11 Seal the enclosure opening of the inverter with the corresponding filler plug 12 Close the inverter see inverter installation manual 7 2 Packaging the Speedwire Webconnect Data Module for Shipping e Package Speedwire Webconnect data module for shipping Use the original packaging or packaging that is suitable for the weight and size of the Speedwire Webconnect module see Section 9 Technical Data page 31 7 3 Disposing of the Speedwire Webconnect Data Module Dispos
24. ocation in the inverter Voltage supply via inverter Mechanical Data Width x height x depth 73 mm x 88 mm x 34 mm Communication Communication Interface Speedwire Webconnect Maximum cable length 100 m Connections Type of plug RJA5 Number of RJ45 terminals 2 Ambient Conditions for Storage Transport Ambient temperature 40 C to 85 C Relative humidity non condensing 10 to 100 Installation Manual SWWEBCONDM lA en 13 31 10 Contact SMA Solar Technology AG 10 Contact If you have technical problems concerning our products please contact the SMA Service Line We require the following information in order to provide you with the necessary assistance e Inverters Type Serial number Firmware version e Speedwire Webconnect data module Type Serial number Firmware version Number of Speedwire Webconnect data modules connected e Large scale PV plants Serial number and firmware version of the Cluster Controller e Small scale PV plants Name of your Sunny Portal plant PIC and RID of the Speedwire Webconnect data module Australia SMA Australia Pty Ltd Toll free for 1800 SMA AUS Sydney Australia 1800 762 287 International 61 2 9491 4200 Belgien SMA Benelux bvba sprl 32 15 28 67 30 Belgique Mechelen Belgi Brasil Vide Espa a Espanha Cesko SMA Central amp Eastern Europe 420 235 010 417 s r O Praha Chile Ver Espa a Danmark Se Deutschland Tyskland 32 SWWEBCONDM A en 13 Ins
25. odule It is not possible to combine the Speedwire Webconnect data module and other communication devices within one plant in Sunny Portal Sunny Portal treats the existing plant and the new small scale plant with Speedwire Webconnect data module as independent plants e Create a new small scale plant with Soeedwire Webconnect data module i Exchange of the Speedwire Webconnect data module in the inverter If you have exchanged the Speedwire Webconnect data module in the inverter for a new Speedwire Webconnect data module the PIC and the RID of the inverter change Therefore you must also exchange the inverter using the Plant Setup Assistant in Sunny Portal see the Sunny Portal user manual In the Plant Setup Assistant you must enter the PIC and the RID of the new Speedwire Webconnect data module Starting the Plant Setup Assistant in Sunny Portal The Plant Setup Assistant is a step by step guide to the processes required for user registration and the registration of your plant in Sunny Portal Procedure 1 Open www SunnyPortal com 2 Select Plant Setup Assistant The Plant Setup Assistant opens 3 Follow the instructions of the Plant Setup Assistant 28 SWWEBCONDM A en 13 Installation Manual SMA Solar Technology AG 7 Decommissioning 7 Decommissioning 7 1 Removing the Speedwire Webconnect Data Module 1 DANGER Danger to life due to electric shock when the inverter is opened High voltages are present in the co
26. roller Requirements Speedwire Webconnect data modules must be installed in inverters see Section 5 3 page 21 Speedwire Webconnect data modules must be connected see Section 5 4 page 23 The Cluster Controller must be connected to the Speedwire network in accordance with the desired network topology see installation manual of the Cluster Controller Procedure l 7 Commission all inverters see inverter installation manual For optimum operation of large scale plants with Cluster Controller deactivate the Webconnect function of the inverters with installed Speedwire Webconnect data module see user manual of the Cluster Controller In large scale plants with Cluster Controller communication with Sunny Portal takes place via the Cluster Controller itself 6 2 Commissioning a Small Scale Plant Requirements 000 Speedwire Webconnect data modules must be installed the inverters see Section 5 3 page 21 Speedwire Webconnect data module must be connected see Section 5 4 page 23 There must be a router with Internet connection in the local network of the plant At least one inverter must be connected to the router If the IP addresses in the local network are to be assigned dynamically DHCP must be activated in the router see the router manual If you do not want to use DHCP or your router does not support DHCP use either the SMA Connection Assist or Sunny Explorer to integrate
27. tallation Manual SMA Solar Technology Deutschland Espa a France India Italia Kibris Luxemburg Luxembourg Magyarorsz g Nederland Osterreich Per Polska Portugal Rom nia Installation Manual SMA Solar Technology AG Niestetal SMA Ib rica Tecnolog a Solar S L U Barcelona SMA France S A S Lyon SMA Solar India Pyt Ltd Mumbai SMA Italia S r l Milano BA rre Bkz EMa a Yunanistan Siehe Belgien Voir Belgien Belgique l sd Cesko Csehorsz g zie Belgien Belgi Siehe Deutschland Ver Espana Patrz Cesko Czechy SMA Solar Technology Portugal Unipessoal Lda Lisboa Vezi Cesko Cehia 10 Contact Medium Power Solutions 49 561 9522 1499 49 561 9522 2499 49 176 888 222 44 Wechselrichter Kommunikation SMS mit R ckruf Hybrid Energy Solutions Sunny Island 49 561 9522 399 Power Plant Solutions 49 561 9522 299 900 14 22 22 Sunny Central Exento de tasas en Espa a Internacional 34 900 14 22 22 Medium Power Solutions 33 0 4 72 09 04 40 33 0 4 72 09 04 41 Onduleurs Communication Hybrid Energy Solutions Sunny Island 33 0 4 72 09 04 42 Power Plant Solutions Sunny Central 33 0 4 72 09 OA 43 91 22 61713888 39 02 8934 7299 800 20 89 87 Isento de taxas em Portugal 351 2 12 37 78 60 Internacional SWWEBCONDM A en 13 33 10 Contact Schweiz Slovensko South
28. y and for customer support from the SMA Service Line The type label must be permanently attached to the product Symbols on the Type Label Symbol Designation Explanation CE marking The product complies with the requirements of the applicable EU directives C Tick The product complies with the requirements of the applicable Grua 14 Australian EMC standards Data matrix code 20 code for device specific characteristics 18 SWWEBCONDM A en 13 Installation Manual SMA Solar Technology AG 4 Product Description 4 3 Cable Gland The cable gland fixes the network cables to the inverter enclosure The cable gland also protects the interior of the inverter from dust intrusion and moisture penetration A B D N Figure 8 Structure of cable gland Item Designation A Filler plug B Seal Swivel nut D Counter nut Installation Manual SWWEBCONDM lA en 13 19 5 Connection SMA Solar Technology AG 5 Connection 5 1 Mounting Position and Cable Route A Figure 9 Mounting position and cable route in the inverter with the lower enclosure lid open and the display flipped up Item Designation A Flipped up display B Cable route to network sockets C Opening in the inverter enclosure with filler plug D Mounting position of the Speedwire Webconnect data module in the inverter 5 2 Cable Requirements and Information on Cable Routing With Speedwire the cable length and quality have an eff