BFT Sub Instructions
Contents
1. Fig 3 34 SUB Ver 03 d 152 158 D811036_03 D811036_03 CF Fig 4 Fig 5 Fig 6 2 gt O O 3 3 min 50mm SUB Ver 03 35 Fig 10 36 SUB Ver 03 Fig 12 13 14 SUB 70 SUBG 125 SUB 5 SUBG 2 5 SUB 5 SUBG 2 5 12 Fig 15 Adjustment screw Vis de r glage Tornillo de regulaci n Parafuso de regulac o Vite di regolazione Stellschraube EU 9 01180 SUB Ver 03 37 Fig 16 Fig 17 D811036_03 Fig 18 CS cose N OPEN Fig 19 1
2. Dimensions nen ace L L een See fig 2 Special voltages available on request 6 ACTUATOR INSTALLATION 6 1 Preliminary checks Check that The leaf structure is sturdy and rigid The upper hinge is in working order and possibly adjustable A hole can be dug to lay the case under the hinge pivot or to one side of the hinge pivot for slide arm installation The leaf ground stop plates are fitted Repair or replace all faulty or worn components Fig 3 illustrates an exploded view of the installation Automation reliability and safety are directly affected by the condition of the gate structure 6 2 Electrical installation setup Set up the electrical installation as shown in fig 4 making reference to the current standards for electrical installations i e CEI 64 8 IEC364 complying with HD384 and other national standards Keep the mains supply connections definitely separate from the service connections photocells electric edges control devices etc WARNING For connection to the mains use a multipolar cable of the type provided for by the previously mentioned standards for example if the cable is not protected it must be at least equal to H07 RN F whereas if it is protected it must be at least equal to H07 VV F witha 3x1 5 mm cross section Connect the control and safety devices in compliance with the previously mentioned installation standards Fig 4 shows the number of connections D811036_03 D8110
3. at any time and without undertaking to update the present publication TABLE 1 ENGLISH Mod SUB EL Block type electric lock Pump flow rate l min 130 Opening angle degrees Max leaf length mt 3 5 Max leaf weight kg 8000N 800 Kg Speed degrees sec 3 9 SUB hydraulic blocks 130 1 8 8000N 800 Kg SUB R hydraulic blocks 0 9 130 1 8 8000N 800 Kg SUB E electric lock 0 6 130 2 5 8000N 800 Kg SUB ER electric lock 0 9 130 2 5 SUB G 1 8 8000N 800 Kg SUB GR hydraulic blocks 0 9 180 1 8 8000N 800 Kg SUB GE electric lock 0 6 180 2 5 8000N 800 Kg V1 V2 V1 V2 hydraulic blocks 0 6 V1 180 V2 V1 V2 8000N 800 Kg en SUB GER electric lock 0 9 180 2 5 8000N 800 Kg 9 SUB Ver 03 17 S f LITA 727777777777777777777 77 E I I 4 1 2 IRR VU VU N Fig 1 ss SE Z VAV AV 4 AV AV AV AV AV AV ZZ 2222 ZEZE B
4. SFIATO APERTURA 1 e OPENING BREATHER 1 PURGE OUVERTURE 1 e ENTLUFTUNG FFNUNG 1 PURGADOR APERTURA 1 SANGRIA DE ABERTURA 2 e SFIATO CHIUSURA 2 CLOSING BREATHER 2 e PURGE FERMETURE 2 e ENTLUFTUNG SCHLIEBUNG 2 e PURGADOR CIERRE L 2 e SANGRIA DE FECHO 38 SUB Ver 03 D811036_03 SUB Ver 03 39 FRANCE Parc Club des Aygalades 35 bd capitaine GEZE 13333 MARSEILLE Cedex 14 0491101860 0491101866 BFT Torantriebssysteme GmbH Johannisstr 14 D 90763 F rth http www bft torantriebe de 0049 911 773323 0049 911 773324 ITALIA Via Lago di Vico 44 36015 Schio VI Tel naz 0445 696511 Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales O bft it
5. actuator output shaft 8 1 Version without slow down function Release the jack with key CS supplied in the way shown in fig 18 With the help of pliers completely rotate the output shaft in the direction of gate closing along its entire stroke Arrange small card CA fig 11 by positioning point M in correspondence with the arrow in the casting Rotate the shaft and bring point G right r h or left 1 h in correspondence with the arrow Protect the actuator from any metal spots during the subsequent welding phase The bush can now be welded to the shoe with the leaf mounted in the gate closed and stopped position Disassemble the shoe to weld bush B all the way around its circumference Any small defects in levelling foundation plate P can be corrected by means of adjustment dowels GR fig 3 Place the gate stop on opening in the required position however the gate stop must maintain an extra rotation of at least 5 for safety in order to prevent the rack from reaching its end of travel NOTE The rotation degrees of the SUB R versions are highlighted in fig 12 in the case of versions without slow down function consider the slow down angles 25 25 as normal speed For the SUB G versions take into account a total rotation of 185 For effective 180 openings the safety margin is 2 5 both on closing and on opening 8 2 Version with slow down function The
6. and a jack which provides a hidden underground installation without any hydraulic connections The gate is kept closed by an electric lock or by a hydraulic lock on the SUB versions supplied with it The versions with slow down functions avoid unpleasant slamming noise when the gate is brought to the final opening and closing stages The pushing force can be adjusted with extreme precision by means of two by pass valves which provide antisquash safety The end of stroke operation is electronically set by a timer on the control panel The emergency release activated by the proper key supplied can be easily reached after removing the appropriate cap found on the cover 2 GENERAL SAFETY WARNING An incorrect installation or improper use of the product can cause damage to persons animals or things e The Warnings leaflet and Instruction booklet supplied with this product should be read carefully as they provide important information about safety installation use and maintenance Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach Keep the instructions together with the technical brochure for future reference This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be
7. and anticlockwise to make is less slow Adjust the slow down speed so as to prevent the leaf from slamming when it stops SUB Ver 03 15 ENGLISH 8 4 Installation with slide arm to one side of the hinge pivot This type of installation is illustrated in fig 9 The installation method is described in paragraph 6 5 Furthermore the actuator support base must be tightly secured to the foundation base by means of screws and not just fastened by the four angle bars as in the case of installation under the hinge pivot 9 STOP PLATES The use of ground stop plates F fig 20 is compulsory both on opening and closing The stop plates must lock the leaf while maintaining a safety extra stroke of 5 at least fig 12 10 LEAF PHASE DIFFERENCE In the case where the leaves overlap during the closing manoeuvre the phase difference on closing is set by means of the appropriate trimmer included in the electronic control unit The motor of the delayed leaf must be connected to the terminals of the control unit which are identified by the Mr symbol as illustrated in the control unit wiring diagram 11 ELECTRIC LOCK FITTING This is only needed for models without hydraulic lock on closing Table 1 The EBP mod electric lock fig 16 consists of a continuous service electromagnet hooked to the ground This device remains energised during the whole gearmotor operation time allowing catch D to reach the closing stop point wit
8. that adjusted with the by pass valves approximately 15 kg 150N In order to make the manoeuvre easier it may also be helpful to activate the hydraulic lock in the way described below 13 2 Versions with hydraulic locks Fig 17 Unscrew cap T which is found on the cover of each actuator usually on the inside Insertthe release key supplied in triangular release pivot PST and rotate it anticlockwise by a few turns CS in fig 18 Push the leaf by hand ata speed similar to that of motorised operation Torestore motorised operation turn the key clockwise until itis completely tightened screw the release cap onto the cover and put the key ina place which is known to all users NOTE In order to avoid oxidation of the release device it is helpful to fill its triangular seat with grease 14 AUTOMATION CHECK Before finally making the automation fully operative carefully carry out the following procedure Check that all components are tightly secured Checkthe correct functioning of all safety devices photocells pneumatic edge etc Check the emergency manoeuvre command Check the opening and closing operations with the control devices in use Check the standard or customised electronic function logic in the control unit 16 SUB Ver 03 INSTALLATION MANUAL 15 AUTOMATION OPERATION As automation can be remotely controlled by means of a radio control or start button it is essential to frequ
9. versions provided with slow down function need particular attention in identifying the fixing point of grooved bush B fig 3 It is advisable to use the actuator in a symmetrical way fig 12 shows the 130 degrees of total rotation of an ordinary actuator divided into the various phases By way of example fig 13 shows the correct operation method for an actuator carrying out a leaf opening manoeuvre of 90 that is 20 20 for safety 70 for normal stroke and 10 10 for slow down In order to obtain the angles described use small card CA on the SUB R mod side fig 11 WARNING For effective opening manoeuvres of less than 90 slow down cannot be obtained in both directions You need to decide beforehand whether to have slow down on closing or opening taking into account that slow down begins to happen in the last 25 30 of shaft rotation both on opening and closing fig 14 Having determined the correct angle for fixing the grooved bush fix it in the way described in paragraphs 8 8 1 NOTE Forthe SUB GR versions take into account a total rotation of 185 out of which 2 5 2 5 for safety 25 25 for slow down and 125 for stroke at normal speed This provides a maximum rotation of 180 8 3 Slow down adjustment R versions only Slow down adjustment screws VR are highlighted in fig 15 and can be adjusted by means of a 3 mm Allen wrench This must be turned clockwise to make the movement slower
10. 36_03 and the cross section for power supply cables about 100 m long for greater lengths calculate the cross section needed for the true automation load 6 3 Main automation parts Fig 4 l Type approved adequately rated omnipolar circuit breaker with at least 3 mm contact opening provided with protection against overloads and short circuits suitable for cutting out automation from the mains If not already installed place a type approved omnipolar circuit breaker with a 0 03A threshold just before the automation system Qr Control panel and incorporated receiver SPL Preheating board for operation with temperature lower than 5 C optional S Key selector AL Blinker with tuned antenna M Controller E Electric lock Fte External photocells emitting section Fre External photocells receiving section Fti Internal photocells with CF posts emitting section Fri nternal photocells with CF posts receiving section T 1 2 4 channel transmitter RG58 Cable for antenna D Connector block The connector block fig 6 must always be positioned higher than the motor In fact as the controller is perfectly sealed the tank is made to breathe through the actuator supply cable 6 4 Cementation of the foundation case under the hinge pivot The case must be cemented under the hinge pivot keeping in mind that the actuator bearing shaft must be perfectly aligned to the leaf rotation axis If the gate is pro
11. D811036 ver 03 12 11 02 I AUTOMAZIONE OLEODINAMICA INTERRATA PER CANCELLI A BATTENTE GB PISTON AUTOMATIONS FOR SWING GATES AUTOMATISME OLEODYNAMIQUE ENTERRE POUR PORTAILS A VANTAUX HYDRAULISCHER UNTERFLURDREHTORANTRIEB AUTOMATISMO OLEODINAMICO SOTERRADO PARA PORTONES BATIENTES LEODIN MICA ENTERRADA PARA PORTOES DE BATENTE Uu m UO m ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATION AND USER S MANUAL INSTRUCTIONS D UTILISATION ET D INSTALLATION MONTAGE und BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INSTRUCOES DE USO E DE INSTALACAO 8 n 11 Via Lago di 44 AZIENDA CON SISTEMA QUALIT dis RE VI N CERTIFICATO DA DNV el naz 0445 6965 U _ Tel int 39 0445 696533 UNI EN 150 9001 Fax 0445 696522 Internet www bft it E mail sales O bft it 2 SUB Ver 03 D811036_03 DICHIARAZIONE DI CONFORMIT DECLARATION OF CONFORMITY D CLARATION DE CONFORMIT KONFORMITATSERKLARUNG DECLARACION DE CONFORMIDAD DECLARAGAO DE CONFORMIDADE Fabbricante Manufacturer Fabricant Hersteiler Fabricante Fabricante BET s r l Indirizzo Address Adresse Adresse Direcci n Endere o Via Lago di Vico 44 36015 Schio VICENZA ITALY Dichiara sotto la propria responsabilita che il prodotto a Declares under its own responsibility that the following product e D clare sous sa propre responsabilit que le produit e Erkl rt auf eigen
12. bove the ground by about 10mm fig 6 Position cover CE fig 3 on the box and fix its corners with 2 screws Fill the rest of the hole with concrete 6 5 Cementation of the foundation case to one side of the hinge pivot Installation with slide arm to one side of the hinge pivot This is advisable when you want to avoid disassembling the existing gate leaf Area A highlighted in fig 9 corresponds to a right angled triangle having a side of approximately 200mm where the actuator axis can be laid in order to allow the leaf to open by at least 90 The drive arm provides a distance between centres between grooved bush and sliding roller R of up to 380mm Bush B must be welded to the drive arm with the leaf completely closed the roller must be inserted into slide S taking into account the safety degrees shown on small card CA fig 11 For slowed down versions also take into account the slow down degrees fig 13 Slide 5 fig 9 can be welded or fixed with screws both underneath and to the side of the leaf The position of the slide is to be identified by marking on the leaf the spots reached by sliding roller R both during closing and opening Having identified the mid point between the two markings made previously align the mid point of slide S and fix it tightly If slide S is shorter than the distance between the two markings on the leaf this type of insta
13. dangerous e The Company declines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the present documentation Do not install the product in explosive atmosphere e The construction components of this product must comply with the following European Directives 73 23 EEC 98 37 EEC and subsequent amendments As for all non EEC countries the above mentioned standards as well as the current national standards should be respected in order to achieve a good safety level e The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use e The installation must comply with the provisions set out by the following European Directives 73 23 EEC 98 37 EEC and subsequent amendments e Disconnect the electrical power supply before carrying out any work the installation Also disconnect any buffer batteries if fitted e Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3mm e Check that a differential switch with a 0 03A threshold is fitted just before the power supply mains e Check that earthing is carried out correctly connect all metal parts for closure doors gates etc and all system components
14. draulic circuit and therefore a bleed operation may be required 17 1 Oil bleed NOTE The actuator is supplied without air in the hydraulic circuit If a bleed operation is required proceed as described below a Remove the cover from the actuator b Activate the opening command and loosen the bleed screw S for opening fig 19 20 during leaf movement c Let the air out until non emulsified oil appears if possible try to prevent the oil leaking out of the bleed screw from falling into the foundation case d Tighten the bleed screw before the actuator runs out of operation time e Activate the closing command and loosen the bleed screw for closing which can be seen in fig 20 during leaf movement f Let the air out until non emulsified oil appears g Tighten the bleed screw before the actuator operation time runs out h Repeat this operation several times for both bleed screws i Restore the oil level checking that it just reaches below cap O fig 19 Top up with IDROLUX oil of the same type 18 NOISE LEVEL The aerial noise level produced by the gearmotor under normal operating conditions is constant and does not exceed 70 dB A 19 SCRAPPING Materials must be disposed of in conformity with the current regulations In case of scrapping the automation components do not entail any particular risks or danger In case of recovered materials these should be sorted out by type electrical components copper al
15. e Verantwortung da das Produkt e Declara bajo su propia responsabilidad que el producto e Declara sob a sua responsabilidade que o produto Motoriduttore per cancelli a battente mod SUB SUBE SUBG SUB EG SUB GR SUB R SUB ER SUB EL SUB GER SUB GR Gearmotor for swing gates mod SUB SUBE SUBG SUB EG SUB GR SUB R SUB ER SUB EL SUB GER SUB GR Motor ducteur pour portails battants mod SUB SUBE SUBG SUB EG SUB GR SUB R SUB ER SUB EL SUB GER SUB GR Getriebemotor f r Drehtore Modell SUB SUBE SUBG SUB EG SUB GR SUB R SUB ER SUB EL SUB GER SUB GR Motorreductor para cancelas con batiente mod SUB SUBE SUBG SUB EG SUB GR SUB R SUB ER SUB EL SUB GER SUB GR Motoredutor para port es de batente mod SUB SUBE SUBG SUB EG SUB GR SUB R SUB ER SUB EL SUB GER SUB GR e E costruito per essere incorporato in un macchinario che verr identificato come macchina ai sensi della DIRETTIVA MACCHINE e Has been produced to be incorporated into a machinery which will be identified as a machine according to the MACHINERY DIRECTIVE e A t construit pour l incorporation successive dans un quipement qui sera identifi comme machine conform ment la DIRECTIVE MACHINES Daf r konstruiert wurde in ein Ger t eingebaut zu werden das als Maschine im Sinne der MASCHINEN DIREKTIVE identifiziert wird e Ha sido construido para ser incorporado en una maquinaria que se identificar como m quina de conformidad con la DIRECTIVA MAQUINAS e Foi construido para ser incor
16. ently check that all safety devices are perfectly efficient In case of any operational malfunction take immediate action and request the assistance of qualified personnel It is recommended to keep children at a safe distance from the automation field of action 16 CONTROL The automation system is used to obtain motorised gate opening and closing There are different types of control manual radio magnetic badge access control etc depending on the installation requirements and characteristics For the various control systems see the relevant instructions All automation users must be instructed on proper control and use 17 MAINTENANCE All maintenance on the controller must be performed with the systems power supply shut off Check periodically for oil leaks When topping up the oil always use oil of the same type see data table and proceed as follows a Remove the cap P fig 3 b Top up with oil until it reaches 1 5 mm on the oil cap hole c Reassemble all of the unit ATTENTION The oil of each actuator must be replaced completely every two years Only use oil of the same type see data table Check the safety devices of the automation When any operational malfunction is not resolved disconnect the power supply from the system and request the assistance of qualified personnel If the leaves move jerkily or if excessive noise is noticed during manoeuvring this could be due to air being trapped in the hy
17. hout opposing any resistance this factor allows the pushing load to be reduced on closing thus improving antisquash safety 12 PUSHING FORCE ADJUSTMENT Fig 1 This is obtained by means of two valves marked by the writing close and open respectively used to adjust the pushing force on closing and opening If the valves are turned towards the sign the force is increased if they are turned towards the sign it is decreased To obtain good antisquash safety the pushing force must be slightly greater than that needed to move the leaf both on closing and opening however the force measured at the leaf edge must not exceed the limits set out by the current national standards The actuator is not provided with electrical limit switches Therefore the motors are switched off at the end of the operation time set in the control unit Such operation time must exceed by about 2 3 seconds the moment where the leaves meet the ground stop plates For this reason as well as for safety reasons under no circumstances must the by pass valves be completely closed 13 MANUAL OPENING In case of emergency for instance when there is no power available the gate must be opened by hand 13 1 Versions without hydraulic locks electric lock As these models are irreversible in order to move the gate by hand you only need to open the electric lock by means of the appropriate key and push the leaves with a force strong enough to win
18. llation is not possible Keep in mind that the INSTALLATION MANUAL ENGLISH nearer slide S is to the leaf rotation pivot the greater will the leaf speed be Having identified the actuator position proceed to cementing the foundation case as described in paragraph 6 4 7 BEARING FOUNDATION CASE Two bearing foundation case models CPS for SUB and CPS G for SUB G fig 10 are available Having installed the bearing case the gate becomes operational even without mounting the actuator which can be inserted later In case of any maintenance needed this type of case allows the actuator to be removed without disassembling the gate leaf Should the CPS mod bearing foundation case be used refer to the respective manual for the positioning procedure 8 LEAF MOUNTING With the actuator in its final position proceed as follows Prepare a U shaped shoe fig 3 where the leaf is to be inserted and then fastened in its correct position by welding small plate PS to it Position grooved bush B in the actuator shaft Temporarily fasten the shoe to the leaf mount the leaf in its completely closed position placed over the actuator shaft and perfectly aligned to the rotation axis Before welding bush B to the U shaped shoe the right fixing point must be found To determine the correct point proceed as described below WARNING Do not weld bush B directly to the leaf Do not weld the grooved bush to the
19. n ist solange die Maschine in die es eingebaut wird nicht als mit den Vorschriften der MASCHINEN DIREKTIVE konform erkiart wurde e Se declara adem s que est prohibido instalar el producto antes de que la m quina en la que se incorporar haya sido declarada conforme a las disposiciones de la DIRECTIVA MAQUINAS Declaramos al m disso que proibido instalar o produto antes que a m quina em que ser incorporada tenha sido declarada conforme s disposig es da DIRECTIVA MAQUINAS SCHIO 30 11 2000 li Rappresentante Legale The legal Representative Le L gal Der gesetzliche Vertreter SUB Ver 03 3 ENGLISH Thank you for buying this product our company is sure that you will be more than satisfied with its performance This product is supplied with a WARNINGS leaflet and an INSTRUCTION MANUAL These should both be read carefully as they provide important information about safety installation operation and maintenance This product complies with recognised technical standards and safety regulations We declare that this product is in conformity with the following European Directives 73 23 EEC 98 37 EEC and subsequent amendments 1 GENERAL OUTLINE The SUB hydraulic controller provides the ideal solution for underground hinge pivot installations as it brilliantly solves aesthetic automation problems The SUB actuator consists of a perfectly sealed single block containing a hydraulic control unit
20. porado numa maquinaria que ser identificada como m quina em conformidade com a DIRECTIVA MAQUINAS conforme ai requisiti essenziali di sicurezza delle Direttive It also complies with the main safety requirements of the following Directives Est conforme aux exigences essentielles de s curit des Directives Es entspricht den grundlegenden Sicherheitsbedingungen der Direktiven Es conforme a los requisitos esenciales de seguridad de las Directivas Est conforme aos requisitos essenciais de seguranca das Directivas e e e BASSA TENSIONE LOW VOLTAGE BASSE TENSION 73 23 CEE 93 68 CEE EN 60335 1 1995 NIEDERSPANNUNG BAJA TENSION BAIXA TENSAO DIRETTIVA MACCHINE MACHINERY DIRECTIVE DIRECTIVE MACHINES 98 37 CEE MASCHINEN DIREKTIV DIRECTIVA MAQUINAS DIRECTIVA MAQUINAS e Sidichiara inoltre che vietata la messa in servizio del prodotto prima che la macchina in cui sar incorporato sia stata dichiarata conforme alle disposizioni della DIRETTIVA MACCHINE e We also declare that it is forbidden to start the product before the machinery into which it will be incorporated is declared in compliance with the prescriptions of the MACHINERY DIRECTIVE e Nous d clarons en outre que la mise en service du produit est interdite avant que la machine ou il sera incorpor n ait t d clar e conforme aux dispositions de la DIRECTIVE MACHINES e Es wird au erdem erkl rt da die Inbetriebnahme des Produkts verbote
21. provided with an earth terminal e Fit all the safety devices photocells electric edges etc which are needed to protect the area from any danger caused by squashing conveying and shearing Position at least one luminous signal indication device blinker where it can be easily seen and fix a Warning sign to the structure e The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers components are used Only use original parts for any maintenance or repair operation Donot modify the automation components unless explicitly authorised by the company e Instruct the product user about the control systems provided and the 14 SUB Ver 03 INSTALLATION MANUAL manual opening operation in case of emergency Do not allow persons or children to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel e Anything which is not expressly provided for in the present instructions is not allowed 3 MAIN AUTOMATION PARTS Single block hydraulic actuator fig 1 consisting of M 2 pole single phase motor protected by thermal circuit breaker P Hydraulic lobe pump D Distributor with adjustment
22. uld the checks listed above be satisfactory replace the actuator 22 2 The gate does not open The actuator vibrates but there is no movement 1 The manual release was left engaged Reset motorised operation Should an electric lock be fitted check that it opens correctly after the start command 2 Check that the capacitor is connected to the motor drive terminals 3 Check that the motor common light blue wire is properly connected 4 Disconnect and reconnect the power supply to the system The first start command must open Should the actuator close reverse the respective drive connections to the actuator 5 Help the leaf to open by hand If the leaf opens check if there are any mechanical problems with the leaf or if necessary adjust the by pass valves as described in the relevant item 12 Should the checks listed above be satisfactory replace the actuator WARNINGS Correct controller operation is only ensured when the data contained in the present manual are observed The company is not to be held responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present manual The descriptions and illustrations contained in the present manual are not binding The Company reserves the right to make any alterations deemed appropriate for the technical manufacturing and commercial improvement of the product while leaving the essential product features unchanged
23. uminium plastic etc 20 DISMANTLING When the automation system is disassembled to be reassembled on another site proceed as follows Disconnect the power supply and the entire electrical installation Remove the gearmotor from its fixing base Disassemble the control panel if separate and all the installation components Inthe case where some of the components cannot be removed or are damaged they must be replaced 21 MALFUNCTION CAUSES and REMEDIES When any operational malfunction is found and not resolved disconnect the power supply from the system and request the assistance of qualified personnel installer When automation is out of order activate the manual release to allow opening and closing manoeuvres to be carried out by hand 21 1 The gate does not open The motor does not turn 1 Check that the photocells or electric edges are not dirty or engaged or D811036_03 D811036_03 INSTALLATION MANUAL not aligned Proceed accordingly 2 Check that the electronic equipment is correctly supplied with power Check the integrity of the fuses 3 Check that the functions are correct by means of the control unit diagnosing leds see relevant instructions Identify any causes for faults If the leds show a persistent start command check that no radio controls start buttons or other control devices keep the start contact activated closed 4 If the control unit does not work it must be replaced Sho
24. valves PC Rack pinion jack Components supplied as standard by pass release and adjustment key Capacitor grooved bush and instruction manual WARNING An actuator can be mounted on the left or right hand side as identified by looking at the gate from the inside opening direction An actuator can be recognised as left or right handed by observing the position of release pivot PST Fig 1 shows an actuator to be mounted on the left 4 ACCESSORIES CPS Bearing foundation case provided for automation CID Non bearing foundation case BSC Slide arm for mounting to one side of the hinge pivot 5 TECHNICAL SPECIFICATIONS Single phase power supply 230V 10 50 60 Hz Motor ee EE 2800 min Output shaft revolutions See Table 1 AbSOrDed power anne en ensen etat 250 W 625181212 c 6 3 uF a O A 14A Max torgue sd u iii ei 400 Nm PROS SUG ran m 3MPa 30 bar max Pump eler A See Table 1 Impact SE lon lo on Hydraulic clutch Manual mandeuvfe zu tuna Release key Max no manoeuvres 500 24hours Thermal ee EE 160 C Environmental conditions 10 C to 60 C Degree of protection ail IP 67 Controller weight SUB 220N 22 kg SUB G 240N 24 kg Ollio etcetera er rane en e E Ox nee E IDROLUX
25. vided with fixed hinges disassemble it and remove the lower hinge If the leaf is high enough from the ground and cannot be removed proceed to supporting it by means of a shim placed between the ground and the leaf during installation If the gate is provided with adjustable hinges remove the lower hinge loosen the upper one and move the leaf to the side If the gate has been newly manufactured fit an upper hinge which can be adjusted Dig a foundation hole having the dimensions shown in fig 5 Provide a drainage pipe fig 6 for rainwater in order to prevent stagnation inside the foundation case Lay a raceway for the power supply cable as far as connector block D Laya strong foundation on the bottom fig 5 where to bury the hooks of foundation case P The dimensions for positioning plate P are defined in fig 5 Let the cement harden for the time needed Rest the actuator on base P with its shaft perfectly aligned to the leaf axis fig 7 and weld four angle bars A in correspondence with the four corners of the actuator centring base The minimum dimension between the pillar and rotation shaft axis is shown in fig 6 Assemble the foundation case by fixing its two half sections together by means of the screws supplied fig 8 and fixing small plate PI to the back Position the box around the actuator so that small plate PI fig 8 fits around the shaft and the edge of the box protrudes a