Home

EntreMatic EMSL USER'S MANUAL

image

Contents

1. the inner and outer activation units and with a key switch emergency push button 1f fitted In this setting two way traffic is obtained The operator selects full or partial opening depending on the volume of traffic The door can be opened with the inner and outer activation units and with a key switch if fitted With an emergency push button the door opens fully Ifthe door remains partly open or is prevented from closing for more than 10 sec full opening is automatically selected Ifthe door is closed from full opening for more than 10 sec the next opening will be partial The width of the partial opening is 75 of full opening Open The door is permanently open The door can be moved by hand e g for window cleaning All activation units but emergency push button 1f fit ted are disconnected Reset Set the programme selector to Auto Insert a narrow object in the small hole on the programme selector and push The operator makes a system test of the battery 1f selected electro mechanical lock watch dog relay and closed position The operator is after closing reset and ready for nor mal operation Note The Reset is not available on the PS 5M Issued 2006 08 15 FAAO76D1EMEI Safety 6 0 Safety 6 1 Integrated safety To permit a safe passage between closing doors the doors reverse immediately 1f an obstruction 1s met They then resume their interrupted movemen
2. EntreMatic EMSL USER S MANUAL ENTRE AV matic FAAO76D1EMEI Issued 2006 08 15 All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB Copying scanning alterations or modifications are expressly forbidden without the prior written consent of applicable company within ASSA ABLOY Entrance Systems AB Issued 2006 08 15 FAAO76D1EMEI Table of content 1 2 3 4 4 1 4 2 Dad 6 1 6 2 6 3 6 4 8 1 Important INTOFMATION 3 33 13 110 0 4 615 E 5 o A ee ee ee ere 6 mm 8 3 17 7 7 0 11111111 7 7 Opera 111 1 301 0 8 seleciona 8 9 0 9 Safety SVSLEM With presence 3333 110 9 Safe system With PMOCOCECNS 2 a 1 0 nae 9 1 7 7 111 10 e e o 11 sins 12 7777 01111111 0 12 7 1 1 1 13 FAAO76D1EMEI Issued 2006 08 15 3 Important information 1 0 Importantinformation Important_notice To avoid bodily injury material damage and malfunction of the product the instructions con
3. From fully swung out posi tion the door leaves can manually be slid sideways offering the possibility to transport wide objects through the opening or to make a shop entrance more inviting during good weather con ditions Mechanical emergency unit MEU An elastic cord is used to open the door in the event of power failure Until the power is restored the door remains open The operator will then resume the function set by the programme selec tor The emergency unit is supervised by the operator control unit which means that the door opens and remains in this position if a proper emergency opening no longer can be achieved Every 3 5 h the following opening impulse generates an emergency opening If the elastic cord opens the door within the limited time the test is successful and the door resumes the function set by the programme selector Electrical emergency unit EEU The door is opened by means of a rechargeable battery unit in the event of power failure The door remains in this position until the power is restored The operator will then resume the func tion set by the programme selector The emergency unit is supervised by the operator control unit which means that the door opens and remains in this position if a proper emergency open ing no longer can be achieved Every 3 5 h the following opening impulse generates an emergency opening If there is no open ing impulse within an additional half hour the operator control unit genera
4. as hospitals and homes for elderly people may not be locked or put in programme selection OFF In other buildings emergency escape doors may be locked or put in programme selection OFF after it is secured that all people has left the building 4 2 Unlocking Unlock all the mechanical locks before switching on the operator Note that more than one lock may be fitted AAB454 AAF239EMA FAAO76D1EMEI Issued 2006 08 15 7 Operation 5 0 5 1 Programme selectors Operation The functions of the door are set with different key programme selectors The key must always be removed on emergency escape doors after changing settings Flush mounted Surface mounted PSMB 5 PS 5M PSMB 5 PS 5M AAF268EMA AAF269EMA Programme selector functions Off Exit Auto yt z Auto width The door cannot be opened with inner and outer activation units The door is locked if an electromechanical locking device has been fitted The door can be opened with a key switch emergency push button 1f fitted Passage from inside only The door is normally locked if an electrome chanical locking device has been fitted The door can only be opened with the inner activation unit and with a key switch emergency push button 1f fitted Two way traffic normal operation of the door The door can be opened with
5. device MOLD Micro switch kit LSK Electrical emergency unit EEU Mechanical emergency unit MEU Break out unit PSB Interlocking Emergency opening External error indication Push button PB Double carriage wheels DCW Synchronization FAAO76D1EMEI Made in clear anodized aluminium as standard Paint finished RAL colours or anodizing optional See separate manuals or installation drawings See page 8 and separate installation drawing 1000 154 See separate installation drawing 1000 155 See separate installation drawing 1000 151 Locked without power Locked with power For manual unlocking of the electromechanical locking device LD See separate installation drawing 1000 214 For indication of door and lock position See separate installa tion drawing 1000 146 Used if a door is required to be opened by means of a recharge able battery unit and remain in this position in the event of power failure EXU 1 EXU 3 required See page 10 Every 3 5h the following opening impulse generates an emergency opening If there is no opening impulse within an additional half hour the operator control unit generates the opening impulse itself If the battery opens the door within the limited time the test is successful and the door resumes the function set by the programme selector Note The test is never performed in programme selector set ting Open or in setting Off Used if a door is required to be
6. egular inspection and cleaning the frequency of which is governed by the environmental conditions at least once a year The best way to remove dust and dirt from the EMSL is to use ordinary water and a sponge A neutral washing up liquid may be used Do not expose windows doors or profiles to alkalis Both aluminium and glass are sensitive to alkalis Do not clean with high pressure water Operator programme selector and sensor may be dam aged and water may enter into the profiles Do not use detergents or abrasive additives Do not scrub with materials like Scotch brite as this will cause mechanical damage 8 1 Inspection 1 Make sure that the glazing rubbers have not shrunk at the corners 2 Make sure that the glazing rubbers are undamaged and straight 3 Make sure that the draught excluders are clean and undamaged 4 Make sure that the rubber seals are clean and undamaged 5 Make sure that the glass 1s clean 6 Make sure that the cover and profiles are clean mE li q Issued 2006 08 15 FAAO76D1EMEI Accessories Accessories The sliding door operator EntreMatic EMSL can be equipped with the following standard or optional equipment If you wish to upgrade your operator or add some extra equipment contact your EntreMatic representative Cover Activation units Programme selector PSMB S5 and PS 5M Programme selector PS 2 Electromechanical locking device LD LDP Manual unlocking
7. opened and remain opened by means of an elastic cord in the event of power failure see sep arate drawing 1000 152 Every 3 5 h the following opening impulse generates an emergency opening If the elastic cord opens the door within the limited time the test is successful and the door resumes the function set by the programme selector Enables the door side screens to be broken outwards in case of emergency by applying a defined pressure Typical to reduce energy losses and not for security reasons used between two operators when the first operator must close before the other one can open EXU 1 required Fireman s opening opens the door in any programme selector setting EXU 1 required Obtained if a lamp or a buzzer is connected to EXU 1 Used to give opening impulse to the door See separate installa tion drawing 1000 215 Used for door weights over 100 kg and for narrow door leaves as anti tilt Used between the operators of two single sliding doors work ing together in very large openings Issued 2006 08 15 13 ENTRE AV matic
8. t at low speed to check whether the obstruc tion has disappeared or not dio f 00119 If an obstruction is met between opening doors and surrounding walls or interior fittings the doors stop immediately and then close after a time delay A 6 2 Safety system with presence sensor Usually the safety system incorporates a presence sensor installed above the door opening If the presence sensor detects an object in the doorway while the doors are closing the doors reverse immediately They then resume their interrupted movement as soon as the object is removed E N AAE593BEM 6 3 Safety system with photocells The safety system can incorporate presence photocells in the door opening If an object is break ing the infrared invisible beam between the photocell units while the doors are closing the doors reverse immediately They then resume their interrupted movement as soon as the object is removed lt lt lt lt po AAF241EMA FAAO76D1EMEI Issued 2006 08 15 9 Safety 6 4 Emergency escape AAE619BEM The operator can be fitted with different emergency escape units to ensure a safe evacuation of the building Break out unit PSB The door leaves and the side screens are swung outwards when a defined pressure are applied to them The break out function can also be used to create a wide opening
9. tained in this manual must be strictly observed Note Instructions design specifications and illustrations which are contained in this manual are not binding Rights reserved for changes without previous notice Environment This operator may be equipped with batteries containing materials which are hazardous to the environment Remove the batteries from the operator before it is scrapped The batteries must be disposed of safely 4 Issued 2006 08 15 FAAO76D1EMEI 2 0 FAAO76D1EMEI Introduction Introduction This manual contains the necessary details and instructions for the daily use of the sliding door operator EntreMatic EMSL The EntreMatic EMSL is designed to offer continuous use a high degree of safety and maxi mum lifetime The system is self adjusting to the effects caused by normal variations in the weather conditions and to minor friction changes caused by e g dirt Issued 2006 08 15 5 Service 3 0 Service When your door needs to be serviced contact the nearest authorized EntreMatic service centre Place for telephone number stamp sticker or the like We recommend inspection of doors at least once a year According to regulations inspection of emergency escape doors is required at least twice a year carried out by an authorized service centre Please check the service book 6 Issued 2006 08 15 FAAO76D1EMEI Locks 4 0 Locks 4 1 Locking Doors used for emergency escape in buildings such
10. tes the opening impulse itself If the battery opens the door within the limited time the test is successful and the door resumes the function set by the programme selector Issued 2006 08 15 FAAO76D1EMEI 7 0 FAAO76D1EMEI What s wrong The door does not open The motor does not start The motor starts but stops during opening The door does not close The motor does not start The motor starts but stops during closing The door moves slowly Troubleshooting Troubleshooting Remedies Change the setting of the programme selector Check the mains switch If break out unit PSB is installed check that the door leaves and side screens are completely closed Unlock the mechanical locks Clean the floor guide Check for objects jammed under the door Change the setting of the programme selector If presence photocells are fitted clean the protecting covers Check the mains switch Clean the floor guide Check for objects jammed under the door Prevent traffic using the door and allow it to do a complete opening and closing cycle with low speed Reset the operator by setting the programme selector to Auto and pushing a narrow object in the small hole on the programme selector Allow the operator to control the closed position without inter ruption Issued 2006 08 15 11 Maintenance 8 0 Note Note Note Note Maintenance The cover doors windows and profiles must be subjected to r

Download Pdf Manuals

image

Related Search

Related Contents

DSR-450WSPL broshure, PDF  CADET Christiane « L`écriture de fiction dans les différents parcours    MXU 250  取扱説明書 - 充専株式会社  DCM Convection Microwave Parts and Service Manual  MGE UPS Systems 40-150kVA Power Supply User Manual  Kühlschrank  the ukpms user manual - Pavement Condition Information Systems  User Manual  