Home
        Premier 412 and 816 User Manual
         Contents
1.                                     22 INS141 5    Premier 412  amp  816 Master User Manual Installation Records       Users       Partitions Functions                                                                                                                Notes       INS141 5 23    Installation Company     Address     Telephone   Fax     Email     Alarm Receiving Centre     Account No   Telephone     Email     Texecom    www texe com    INS141 5    
2.                                    Bypassing Zones                         Manually Bypassing Zones   Unbypassing Zones     Group Bypass                     a    Quick Bypass and Arm                   sse                       User Functions Menu                               11    Reset Alarms                             Last Alarm Log      si  Service Faults                                          zd   Acknowledging a New Service Fault       View Service Faults                                  11  Anti code Reset                                                               12  Toggle Chime On and Off    bee  Change User Code               3  View Log  LCD Only     bes  Abort Communications                                                13    System Program Menus                                Programming Text  LCD                                                    Programming Users                                           Program User   User Options 1   User Options 2   User Options 3   User Text  LCD Only   System Tests  amp  Utilities   Walk Test   Test Speakers  amp  Outputs   Send Test Call   Enable Download Engineer Access   Start Call Back   Program Time       Program Date  Program Banner Text  LCD only   Print 100 Events C95C8D              19    Fire Safety  amp  Maintenance                         20    Flre Safely                       teens  Fire Alarm Operation s  Household Fire Safety                                                    20  Fire Escape Plannin
3.                             od z c oo         X Y Z    Custom characters          z  0   5    Move cursor left and right                                 Backspace  delete              8190 6  0 0 001010000    Accept text       14    INS141 5    Premier 412  amp  816 Master User Manual    System Program Menus       Programming Users       Enter Access code    Then press ce   then C95       Y    Programming Menu  Enter Code  gt  77         ia d PM CRIT Ue  Alam O     e e e e e e    O ames  Service        D       TEN  Alam O       O O    O O            Service        EI n d n  Alarm O W    O O O O O            service O M esty    Continues on  Next Page    Program User          Enter User Number  PE           User Options 1          Enter User Number  PE           User Options 2          Enter User Number  PE           User Options 3          Enter User Number  PE        P gt        Program User 85  Code i                 Alum       Service O          Enter Code MMM    Press or if code is  less than 6 digits              Program User 85  Code i             am              e    Service O          Re enter New Code  DOOD             User B3 Ortionsi   gt  Deke rs  lt     Zones    Sy ert Stemi th Pura                O                    O          Service O   Ready       Use keys CD   to  select deselect Options   Then press or             User B3 Ortions       dob Eek  lt     pank  Alam O O O       Service              Use keys     to  select deselect Options   Then press or      
4.        Press    to scroll up and down through the log   Press to when finished     Abort Communications    This option aborts any communications to the Alarm  Receiving Centre      gt    To Abort Communications  proceed as follows        Enter Access code DDOD  fas  lt  uh VES to Arm   Panes RP LN      ep          for   rtionz  Enter  en  C7     um    6666 0 OO 6 Dames    Service       Ready       Premier 316  lr 3B8 21 25   64  The keypad will bleep and the alarm system will abort  all communications to the Alarm Receiving Centre        INS141 5    13    System Program Menus    Premier 412  amp  816 Master User Manual       4  System Program Menus    The Master User and Users with the relevant access level  can access the System Program Menus  These menus allow  the users access to the more advanced features and  functions of the alarm system     The following programming menus are available     Function  Programming Users       Program User       User Options 1       User Options 2       User Options 3       User Text       System Tests and Utilities       Walk Test  Test Speakers and Outputs  Send Test Call  Enable Download Access  Start Call Back    Program Time                      Program Date       Program Banner Text  Print 100 Events                A Menus C85C05   BED are restricted to Access  codes enabled for Code Programming  Master  Users      Menus DDD   DD are restricted to Access  codes enabled for User Programming     To abort programming at any stage and pr
5.       completion press the key        INS141 5    11    User Functions Menu    Premier 412  amp  816 Master User Manual          Service Faults Displayed on LED Keypads    Fault Condition       AC Fail       Telephone Line Fault       2 Wire Smoke Alarm       Box Tamper  amp  Auxiliary Input    Press   to view type  Lights 1   3 will light up   Light 1   Box Tamper   Light 2   Auxiliary Tamper   Light 3   Auxiliary PA       Date or Time Lost       Zone Tamper Trouble  Press    to view zone number       Keypad Tamper Removed  Press   to view keypad number       Equipment Faults   Press to view fault type    Light 1   Output 1 Fault   Light 2   Output 2 Fault   Light 3   Siren Bell Fault   Light 4   2 Wire Smoke Sensor Fault   Light 5   Auxiliary Fuse Failed   Light 6   Battery Fault   Light 7   Service Timer Zone Soak Test Failed       Light 8   Communication Fault    Service Faults Displayed on LCD Keypads    LCD    Fault Condition       AC Fail    AC Fail       Line Fault    Telephone Line Fault       Smoke Alarm CZW     2 Wire Smoke Alarm       Bos Aus Tamrer    Box Tamper       Aux Tamrer    Auxiliary Tamper       Aux PA Alarm    Auxiliary PA       DateTime Loss    Date or Time Lost       TamrFer Zone  gt  El    Zone Tamper Trouble       TamrFer Keyrad gt  1    Keypad Tamper Removed       Quteut 1 Fault    Output 1 Fault       Quteut Z Fault    Output 2 Fault       Siren Fault    Siren Bell Fault       Smoke Sen  Fault    2 Wire Smoke Sensor Fault       Aux  Fuse Fault    
6.      e Reset  User Options 1 CD e View Alarm Log  User Options 1 can be enabled or disabled for a selected e View Service Faults  user so that the level of access to the system may be e  Enable Chime  altered  The following options are available   u e Change Own Code  CD Enable for Partition 1        Off  The user cannot access the above user functions   On  The user can access Partition 1   Off  The user cannot access Partition 1   User Options 2 DE  e ipe Tor EE ition 2 User Options 2 can be enabled or disabled for a selected     Ta user San een         2 user so that the level of access to the system may be  d BUST CANNOT ACCESS FANON  A  altered  The following options are available   C35 Enable for Partition     Premier 816 Only  X   Enable One Time Use Access Code  zi a Cen CAL    58              The Access code can only be used once to arm and    user cannotaccess             disarm the system  After the Access code has been  X4   Enable for Partition 4  Premier 816 Only  used to disarm the system it is automatically deleted   On  The user can access Partition 4  Off  The Access code behaves normally   Off  The user cannot access Partition 4   16 INS141 5    Premier 412  amp  816 Master User Manual    System Program Menus       C25 Time Lock Code with Control Timer 1   On  When Control Timer 1 is on  the Access code will not  be accepted by the system  When Control Timer 1 is  off  the Access code will be accepted by the system    Off  The Access code will be accepted a
7.     The remote keypad will now indicate information  relevant to the selected partition     79000889898       Service     e Ready     ub UG OGSOr    Service O    Ready       D   After changing to the selected partition  the remote  keypad will only remain in the selected partition for 10  seconds after the last key press  However if an  Access code is entered whilst the remote is in this  mode  the remote keypad will remain in the selected  partition for 1 minute after the last key press     Bypassing Zones    Manually Bypassing Zones  Bypassing a zone prevents it from causing an alarm     PS After manually bypassing a zone  the zone will remain  bypassed until the zone is manually unbypassed     The Bypass menu will time out if no key is pressed for  60 seconds        To manually bypass zones  proceed as follows     Enter Access code DODD    Ea      VES to Arm   209559556      MENU for Ortions    Press    Bypass Zone  B     H  HE BYPASSED  The Ready light will flash quickly     Enter the zone number D    e g  Enter OD to select Zone 2     e  o    e   E dB ou Bypass Zone   Bz  denen Zone BZ Byurassed    The selected zone is now bypassed  Repeat step 3 to  bypass additional zones        mmo                         Dames  Service O    rca          Once the selected zones have been bypassed press   CD Gm to Away arm  to Stay arm  Ge to return to the normal disarmed state    D   If the Quick Bypass feature is enabled  you can omit  step 1 from the above procedure     When one or 
8.    THANK YOU FOR VOTING                   MASTER USER MANUAL       Premier 4412   e  Premier S 9  6     Security Control Panels with Integrated  Communicator    Issue 5    c    Texecom    Www texe com          Contents    Premier 412  amp  816 Master User Manual       About the Alarm System                                3    Introduction  riii rerit  About this Manual     Fire Detection          iicee tenente ener  Monitoring                     Zones and Partitions    Access Codes        Remote Keypads       Keypad Types        Keypad Layouts            sise  F  nction Keys    uu n settle its  Emergency KeVS  s entretient nenne           Operating the Alarm System                        6    Introduction                 IU iini eren                      nado Eran  Access COdes       ene peperere breeders  Arming  amp  Disarming the Alarm System                             Checking if the System is Ready to Arm       Away Arming  Stay Arming                                   Cancelling the Arming Process    Disarming During Entry                Tr A  Disarming when not in                                                        Disarming after an                                                              Auto Stay Arming                                        Changing from Delayed to Instant Stay     Arming and Disarming Partitions       Away Arming Partitions                 Stay Arming Partitions        ers m  Disarming Partitions     Changing to another Partition         
9.   Before Stay arming check the following     e Secure or bypass any perimeter zones that are violated     e Ensure no  unintentionally     perimeter zones are bypassed    e Ensure no perimeter Force Armable zones are violated  unintentionally        To Stay arm the alarm system proceed as follows     Enter Access code DDD    Zones    AlamO O O O O O O O O O med    VES to Arm            for Ortions    Press    re 5    T Premier 516  ETOR aren em 17 30 21 78484    The alarm system will arm immediately and the Armed  light will flash     service O YW Ready          The system is now Stay armed     D   If the Quick Arm feature is enabled  you can omit step  1 from the above procedure     If the system is fitted with a Premier RKP16 Plus then  the Stay light will also illuminate when the system is  Stay armed        INS141 5    Premier 412  amp  816 Master User Manual    Operating the Alarm System       Cancelling the Arming Process     To cancel the arming process during the exit delay   Enter Access code CDC  nus    MENU for Ortions  m0 6 6    6 0    6    mm HO to Disarm  3  Press Press    P5 eed Premier 816  mob 6 800 855 0m 17 38 21 28704    Arming has been cancelled and the alarm system is  now disarmed           cS If the system only has one partition you will not have  to perform step 2     Disarming During Entry       To disarm the alarm system during entry  proceed as  follows     Enter the premises via the designated entry point   the entry tone will sound  Proceed direc
10.   G  jkl5JKL           amp G gt  mno7MNO       Delete User           Enter User Number  DD              Am O X XXX O O O O O O O Amea  Service O    Ready    Program User B    Code         G2pqrs7PQRS   Dtuv8TUV  G 2wXyz9WXYZ   D Space 0          Move Left Right       Backspace  delete     Zones    Alam O                       O O O v                               Press          Program User    C      Allow Arming       The Program User option allows the engineer to assign new en be oye caman the parens        have GS gen  SU system Off  The user cannot arm any partitions   Each user is assigned the following attributes  C8   Allow Bypassing  e Access Code On  The user can bypass zones in partitions they have  This is a unique 4  5 or 6 digit code that is assigned to been given access to   the user  The system will allow a mixture of different Off  The user cannot bypass zones   length Access codes  The Access code must be entered CD Allow Disarming  at a keypad before the user can operate the alarm On  The user can disarm the partitions they have been  system  given access to   e User Options 1 Off  The user cannot disarm any partitions   See User Options 1 below for details      User Options 2 Nore        Engineer code  User 00  can only disarm the  See User Options 2 below for details  Ede if the system was armed with the Engineer  e User Options 3        Allow User Functions  See User Op  ons              Ts or details  On  The user can access the following user functions 
11.   it will turn on and the keypad will    sound the Chime tone  If Chime was on  it will turn off  and the keypad will sound the acceptance tone          6B 0 0 6 6 6 Dames  Service O    Ready          12    INS141 5    Premier 412  amp  816 Master User Manual    User Functions Menu       Change User Code    All users of the alarm system can change their own Access  code number      gt    To change your Access code  proceed as follows   Enter Access code DD    NA    VES to Arm   heo  6666 p MENU for   etions    Enter ae    smo    6 6 8   8 0 0 ou  dee Code i                  Enter new code Ma  If the code is 4 or 5 digits press the G   Ge   key to  accept     He MCI is ae  dee Code i sek    Re enter new code DODD             The keypad will sound an acceptance tone if the new  Access code was accepted  If you hear an error tone   low   please repeat from step 1     View Log  LCD Only     The control panel has a 750 Event Log  which stores all  system activity i e   users entering their codes to arm and  disarm the system  alarm events  faults etc  Each event is  time and date stamped        To view the Event Log  proceed as follows     Enter Access code MODE    VES to Arm   MEHU for Ortions  Enter   amp   gt C6 gt     Event Type   showing Zone Text     Event Type   Alarm           amp  2                Bedroom 1 FA FA Aud BZ Alm  1    13 15 56 28 13 15 56 25 84  T T T  Partitions Time Day Time    1   Press to toggle 4    information displayed                 Day Month         
12.  About the Alarm System        D      Alarm Light  If an alarm has occurred whilst the  partition system was armed the Alarm light will illuminate     The alarm partition system cannot be Armed until a  standing Alarm has been acknowledged reset  see     Acknowledging an Alarm    on page 11      Service Light  The Service light will flash when a new fault  occurs and will change to on steady when the fault has  been acknowledged  When the system is free of all faults  the Service light will be off     The alarm system cannot be armed until the new faults  have been acknowledged  see    Service Faults    on page  11      Armed Light  The Armed light indicates the armed status  of the partition system  The Armed light is on when the  partitions assigned to the keypad are armed  When the  Armed light is off the partitions are disarmed  The Armed  light will flash as follows     Partition in Exit  Slow flash  1 second on  1 second off      Partition is Delayed Stay Armed  Slow flash  1 second on   1 second off      Partition is Instant Stay Armed  Fast flash    milliseconds on  200 milliseconds off       200    Ready Light  If the Ready light is on the partition system is  ready for arming  If the Ready light is off  one or more  zones within the partition system are violated  check the  relevant zones as indicated on the keypads  If the Ready  light is flashing  one or more zones are bypassed or are  violated and force armable     Zone Lights  The zone lights indicate the status
13.  User 5 Ortionss             lt     Zone     ch oe WY rs S OT                         6          O Armed    Service      Ready          Use keys CD   to  select deselect Options           Then press or       Return to point A     Led Key     Off    e On    Slow Flash  x Fast Flash       User Options 1   C1   Enable for Partition 1     Enable for Partition 2   C3   Enable for Partition 3  Premier 816 Only   C4   Enable for Partition 4  Premier 816 Only      Allow Arming   C6   Allow Bypassing     Allow Disarming   Allow User Functions    User Options 2   CD Enable One Time Use Access Code    Time Lock Code with Control Timer 1  C3   Enable Open Reporting   C4   Enable Close Reporting   C5   Enable User as Duress Code   C6   Activate Door Strike Output   CD Allow Global PA Fire Silence    User Options 3   CI   Allow Engineer Code Programming  C2   Allow NVM Locking     Allow Engineer Programming   C Allow Test Call Transmission      Allow Alarm Fault Acknowledgement  C6   Allow User Programming     Allow User Code Programming  Local Partition Access Only       INS141 5    15    System Program Menus    Premier 412  amp  816 Master User Manual       From  Previous Page    User Text                         _  Use    to select User     Engineer  Press to edit text     ser BA Text        Led Key     Off    e On    Slow Flash    Fast Flash       Text Editing Keys             1      amp     gt D abc2ABC       Use keys to enter edit text   Then press to accept     GD def3DEF    ghl4GHI
14.  feature must be enabled to use this  feature        10    INS141 5    Premier 412  amp  816 Master User Manual    User Functions Menu       3  User Functions Menu    This section covers the more advanced functions that  selected users can perform with the alarm system  The  following functions are available     Reset Alarms    This function is used to reset any standing alarms and  service faults  It is also used to reset detectors with a latched  alarm indication  e g   Smoke Detectors        To Reset Alarms  proceed as follows        Enter Access code DDD  per DE VES to Arm   V hci                      for Ortions  Press  amp     gt C0D Press    HOO C OOo OOS Oar Premier 316    ir 38 21 z84 84       Service        Ready    The keypad will bleep and the alarm system will reset  all latching detectors and attempt to clear any standing  Alarms or Service Faults     Last Alarm Log    The control panel has a memory that stores the zones that  caused an alarm when the system was last armed      gt    To view the alarm memory  proceed as follows   Enter Access code DDD  ae ia mum VES to Arm   EMA ge          for Options  Press eC  Last Alarm From   zone 5  Last Alarm From   Zone Ed    The keypad will display the zones that caused an alarm  when the system was last armed           Press Gen  to return to the normal disarmed state     Service Faults    The response to a Service Fault condition is programmed by  the installer but is normally limited to the keypad buzzer  To  silence
15.  local fire  department and request further information on fire  safety and escape planning  If available  have your  local fire prevention officer conduct an in house fire  safety inspection     Maintenance    With normal use  the system requires minimum  maintenance  The following points should be observed     1  Do not wash the security control panel or keypads with  a wet cloth  Light dusting with a slightly moistened cloth  should remove normal accumulations of dust     2  The battery test is designed to determine battery  condition  We recommend  however  that the stand by  batteries are replaced every five years     3  For other system devices such as smoke detectors   passive infrared  ultrasonic or microwave motion  detectors       glass break detectors  consult the  respective manufacturer s literature for testing and  maintenance     Glossary of terms used in this manual     Access Code  A four  five or six digit code that is used to  operate the alarm system     Alarm Receiving Centre  A remote location where alarm  status data is received via the telephone line from the control  panel     Bypass  A feature that allows the user to exclude selected  zones from being monitored by the alarm system     Chime  A feature that allows the keypads and internal  sounder to generate a ding dong sound whenever the  selected zones are violated     Duress Code  A special type of Access code that reports a  signal to the alarm receiving centre that indicates the system  is being
16.  of each  alarm zone within the partition  When a zone is violated or  in trouble the relevant zone light will illuminate  When a  zone is secure the relevant zone light will be off     A keypad can be programmed to blank its display after a  period of time  An Access code may be required to re   enable the display  Otherwise simply press any key     Zone display is always enabled when the alarm system is in  alarm     Function Keys  See    Function Keys        Fire  if the Fire light is on with no zone indicators  illuminated  then a fire alarm has occurred from one of the  2 wire smoke sensors  If there is an accompanied zone  indication  the fire alarm has occurred from the smoke  sensor on the indicated zone     Bypass  If the Bypass light is on  one or more zones have  been manually bypassed   see  Manually Bypassing  Zones  on page 9      Stay  If the Stay light is on  the partition system is in the  stay armed mode  The Armed light will also be flashing     Instant  If the Instant light is on  the partition system is in  the stay armed mode and the delayed zones  front door  etc  are instant  The Armed light will also be flashing  rapidly     Power Light  The power light is on steady when mains  supply is present and flashes when the system is running  on battery  mains fail      LCD Display  16 character Liquid Crystal Display  LCD      Function Keys  The remote keypad function keys are described as follows     A   lt     Function       The Bypass key is used for eith
17.  operated under duress     Forced Armable  An option that can be selected on a zone  by zone basis  that will allow the system to be armed  even if  the selected zone is violated     Group Bypass  A feature that allows the user to bypass a  group of zones in one go     Partition  One or more zones that make up an individual  area  This area can independently be armed and disarmed  from other partitions     Service  A condition that will indicate that a problem has  occurred with the alarm system or with one of its detection  devices     Zone  A zone is an area of protection that has one or more  detection sensors connected to it  motion detectors  glass   break detectors  door contacts or shock sensors         INS141 5    21    Installation Records Premier 412  amp  816 Master User Manual    6  Installation Records    Control Panel       Model  Premier 412  Q Premier 816        Location        Keypads    Police   Medical PA Quick Quick   4 amp 6     7 amp 9  Silent Disarm Bypass    Location Partitions                                                             Timers  Timer Partition 1 Partition 2 Partition 3 Partition 4  Exit Time Sec  Sec  Sec  Sec   Entry Delay 1 Time Sec  Sec  Sec  Sec   Entry Delay 2 Time Sec  Sec  Sec  Sec   Alarm Delay Time Min  Min  Min  Min   Bell Delay Time Min  Min  Min  Min   Bell Duration Time Min  Min  Min  Min                       Zones    Protected Area Zone Text Partitions Zone Type                            IN BR  GOO  N                   
18.  the Service Fault alarm  enter your Access code     A flashing Service light indicates a new fault condition  The  alarm system cannot be armed whilst a new fault exists  The  Service light will remain flashing until the new fault is  acknowledged  after which it will revert to a steady yellow  and the alarm system can be armed  The Service light will  remain steady until all faults have been cleared     AC Fail and Telephone Line Fault can each have a delay  programmed  The Service light will turn steady yellow  immediately on either of these faults but no Service Fault  Alarm  transmission or audible alarm  will occur unless the  delay expires     PS If your installer has disabled AC fail acknowledgement  the Service light will flash    rapidly    during an AC fail  condition  The system can be armed without requiring  acknowledgement of this fault     Acknowledging a New Service Fault   gt  New service faults can be acknowledged as follows     Enter Access code DD      P   VES to Arm   QUE DII wee MENU for Ortions    Press Geu C2 gt            I tX9 Gr CH9  9 GO      System Faults       dns Press Menu   Reset  Line Fault  Press Menu   Reset    The keypad will display all Service Faults           Press       or to acknowledge the fault and return to  the normal disarmed state     View Service Faults       Standing faults can be viewed as follows     1  Press the key followed by the C2   key     2  The keypad will display any Service Faults  see  tables on next page      3 
19.  the selected zones have been bypassed press   A G to Away arm  to Stay arm  to return to the normal disarmed state    D   If the Quick Bypass feature is enabled  you can omit  step 1 from the above procedure     When one or more zones are bypassed the Ready  light will flash and if the system is fitted with a Premier  RKP16 Plus or Premier LCD LCDL then the Bypass  light will also illuminate     Quick Bypass and Arm    The Quick Bypass and Arm feature allows you to bypass a  predefined group of zones and Away or Stay arm the  system  The alarm system has up to four groups        To Quick Bypass a group of zones and Away arm   proceed as follows     Enter bypass group C1     C45    Zone     Am O O O O O O O O O         ervice        Premier 816  19 30 56 28 64    Press    Please Exits     19 30 56 28 64    s    Ready       Press       Am O O O O O O O O                        Ready    s       The Armed and Ready lights will flash and the exit tone  will sound     When the exit tone stops  the system is Away armed  with the selected group of zones bypassed        To Quick Bypass a group of zones and Stay arm   proceed as follows     Enter bypass group CD   C45  Premier 816  19 36 56 254   Press    e  a xh Premier 216  Le ANRT ND    19 30 56 78 84    The alarm system will arm immediately and the Armed  and Ready lights will flash     AmO O O O O O O O O O amd       Service O    Ready       The system is Stay armed with the selected group of  zones bypassed     D   The Quick Arm
20.  user program  menus      gt  Allow User Code Programming   On  The Access code can access users 01 to 31 in the  User programming menus  menus 80   83     Off  The Access code cannot access user 01 to 31 in the  User programming menus     Local Partition Access Only   On  The Access code can only be used to arm and disarm  the partitions that are assigned to the remote keypad   For example  if the user is assigned to all four  partitions and they use a remote keypad that is only  assigned to Partition 1  they will only be permitted to  arm and disarm Partition 1 at that particular remote  keypad    Off  The Access code can be used at any remote keypad   Global Access      User Text  LCD Only  DAD    If the system is fitted with either a Premier LCD or LCDL  remote keypad you can assign up to 8 characters of text to  each user  This text is used when viewing the system Event  Log  see page 13  User text is programmed in a similar way  to mobile phones  Characters are selected by pressing the  corresponding key the appropriate number of times  to  select a character on the same key  press      to move the  cursor along   For details on entering text  see page 14        INS141 5    17    System Program Menus Premier 412  amp  816 Master User Manual    System Tests  amp  Utilities    Enter Access code          Then press  e then C9                  Programming Menu Led Key  Enter Code  gt  77     Off    On    Slow Flash  Fast Flash             Walk Test    Walk Test Fone G1 Acti
21. Auxiliary Fuse Failed       Battery Fault    Battery Fault       Service Reauired    Service Timer Zone Soak Test Failed       Coms Failed       Communication Fault       Anti code Reset    This feature is normally used in the UK where users are not  permitted to reset the panel following a communicated  alarm  However  the user can reset the panel after entering a  unique remote reset number  which is supplied by their  installer or ARC        To perform an Anti code Reset  proceed as follows   Enter Access code DODD    ien um VES to Arm            8655 PIS MENU Por Options    Press      Quote Code   4855  Enter RerPlulj777     eO             keypad will display a  randomly generated       Alarm     O O O           on          4 digit Code     02900909                  Service O Ready       Contact your ARC Installer to obtain a Anti code Reset  number     Tel No     Enter the Anti code Reset number given to you by your  ARC Installer QD     If the code is accepted  the keypad will sound an  acceptance tone and the system will reset and return to  the normal disarmed state     Toggle Chime On and Off    When a zone is enabled for Chime the keypad will generate  a Chime tone every time the zone is violated  This function  allows you to turn the Chime feature on and off      gt    To toggle Chime on and off  proceed as follows     Enter Access code DDD    ee pee VES to Arm   mmo    6    60    6    oam ady HEHU for   rtionz  Press  Premier 516  17 38 21 z84 B4  If Chime was off
22. NOTE    afa MEDICAL    D  amp  D          The emergency keys can be individually enabled or  disabled for each keypad on your alarm system by  the installer     The Panic alarm can be individually programmed for  either audible or silent operation for each keypad     Emergency commands are detailed on the inside flap  label of each remote keypad        INS141 5    Operating the Alarm System    Premier 412  amp  816 Master User Manual       2  Operating the Alarm System    Introduction    Before attempting to operate the alarm system ensure you  have familiarised yourself with all the arming and disarming  methods covered in this section     Access Codes    e  fyou make a mistake whilst entering your Access code   simply enter the correct Access code     Arming  amp  Disarming the Alarm System    Checking if the System is Ready to Arm    To help prevent faults during arming  a Ready light has  been provided on each keypad  The Ready light works as  follows     e  fthe Ready light is on steady then the alarm system is  ready to be armed     e Ifthe Ready light is flashing then the alarm system has  bypassed zones and or Force Armable zones that are  violated  check these zones before proceeding     e If the Ready light is off then one or more zones are  violated  either secure or bypass these zones before  proceeding  The keypads will display the zones that are    violated   zone 81 Active  Front Door  gu    zone B4 Active  Fatio Doorz    Active zones are indicated by Active zo
23. d  indications for Fire  Bypass  Instant and Stay  It also features  two programmable zone inputs that can be utilised by your  installer for detection devices close to the location of the  remote keypad     Premier LCD  The Premier LCD has a standard size 32  character back lit Liquid Crystal Display  It also features two  programmable zone inputs that can be utilised by your  installer for detection devices close to the location of the  remote keypad     Premier LCDL  The Premier LCDL has a large size 32  character back lit Liquid Crystal Display  It also features two  programmable zone inputs that can be utilised by your  installer for detection devices close to the location of the  remote keypad     Keypad Layouts                                             o  1      6    lil  STAY  4 5 6 MENU  6   DISARM     8 9  O AREA       Premier RKP4 8 16                                                                                                                                                                                                  jer    12 13 14 15        Fire    Bypass    Instant Ld Stay            49  C1 2 abc    def _ Arm Bypass  4 ghi 5 jkl 6 mno Stay           7 pars 8 tuv 9 wxyz Disarm Reset  Yes  gt    0    No Area Menu  Premier RKP16 Plus        D         Service         1 2 abe    aet Bypass   Reset  4 qni 5 ju 6 mno  gt  es A  7 pars 8 tuv 9 wxyz Stay v  Yes  gt   Qu No Area Menu  Premier LCD LCDL       INS141 5    Premier 412  amp  816 Master User Manual   
24. d with a Premier RKP76 Plus then the Fire  light will be illuminated  The alarm is also transmitted to the  Alarm Receiving Centre  if your installer has enabled this  feature     Silence  To silence the bell or siren  enter your Access code     Resetting Smoke Detectors   Once the smoke detector is reset  if it still detects smoke  the  alarm sequence will resound as described above  If there is  no smoke  the system will return to normal operation      gt    To reset smoke detectors  proceed as follows     1  Enter your Access code DDC      2  Press the key followed by the C0   key  If your  system is fitted with either a Premier RKP16 Plus or  Premier LCD LCDL then press the key     3  The keypad will bleep and the alarm system will reset  all latching detectors     wore  f you suspect that a fire alarm has transmitted and  that there is no fire condition  call the alarm receiving  centre to avoid an unnecessary response  If a fire  condition is apparent  follow your evacuation plan  immediately  If the alarm sounds at night  evacuate  immediately     The description above may not be applicable  depending on how your installer has programmed the  fire alarm operations on your system  Ask your  installer for more information regarding your system s  operation     Household Fire Safety Audit    Most fires occur in the home  To minimise the risk of fire  it is  recommend that a household safety audit is conducted and  a fire escape plan is developed     e Are all electrical a
25. e exit tone will stop  The selected partition s  is  now Away armed     D   If the Quick Arm feature is enabled  you can omit step  1 from the above procedure     Stay Arming Partitions  This option allows you to Stay arm one or more partitions        To Stay Arm selected partitions  proceed as follows     Enter Access code DD    Zones    AamO O O O O O O O O           VES to Arm   CS WW Ready HEHU for Ortions    Press    AO       O O O O O           YES to Arm   sence O rs Ares  gt         lt           The Ready light will flash quickly   Press D   C to select deselect partitions   e g  Press C1   to select Partition 1     AO     O O O O O O O        VES to Arm   service O dee Area  gt  lt    lt        Partition 1 is now selected     Press    Zones    Alam O O O O O O O O             Premier 816    ir 38 21 25704    The selected partition s  will arm immediately and the  Armed light will flash        Service O    Ready    The selected partition s  is now Stay armed     Disarming Partitions  This option allows you to disarm one or more partitions        To disarm selected partitions  proceed as follows     Enter Access code DE    Zones    AO O O O O O O O O                    for OFtions  HO to Disarm        Service O    Ready    Press        DOT        Cera   AkmO O OO O O OOO E  Service O y    HO to Disarm   Ares  gt  k               The Ready light will flash quickly   Press    C4   to select deselect partitions   e g  Press C2   to select Partition 2     HO to Dizarm   Ar
26. er group or manual  bypass of zones  see page 9         The Menu key is used to access the more advanced  user functions and programming options        The Arm key is used when away arming the system or  partition        The Stay key is used when Stay arming the system or  partition        0 66 00    The Disarm key is used when disarming the system or  partition        9    The Area key is normally used when arming and  disarming a particular partition  When the Area key is  pressed on its own the keypad will indicate the armed  status of all partitions     The Area key can also be used to temporarily switch  the keypad to a different partition  see page 9        The Chime key is used to enable disable the chime  feature  see page 12        The Reset key is used to reset the system after an  alarm or service fault condition  see page 11        The Yes key is used to arm the system and to select  menu options        8 66 0    The No key is used when disarming the system or  partition           C    NOTE    When a keypad is in use other keypads will be locked   out except for emergency functions  The lock out will  persist 4 seconds after the last key is pressed   Information tones will be limited to the keypad in use     Emergency Keys   In case of emergency  the alarm system can provide three  immediate emergency alarms by pressing and holding two  specific keys for three seconds     Emergency Alarm    Press Keys       D  amp  D       FIRE       D  amp  C65       Pouce       
27. es  gt           Zones    AamO O 6 O O O O O O O me         Service                  Partition 2 is now selected for disarm     Press Press    Zones    Alam O O O O O O O O O O ma Premier 816    ir 38 z1 25704       Service O    Ready    The selected partitions are disarmed        INS141 5    Premier 412  amp  816 Master User Manual    Operating the Alarm System       Changing to another Partition   Normally the remote keypad that you use will be assigned to  a particular partition and therefore the zone and status lights  will indicate information relevant to the assigned partition   However  you can temporarily switch the remote keypad to a  different partition so that the zone and status lights indicate  the information relevant to the partition that you have  selected  Whilst in this mode you can also use your Access  code to arm disarm the partition you have selected   providing you have access to the selected partition      In order to use the cross partitioning feature  it is  recommend that the system is configured as follows     e Cross partitioning must be enabled   e The user must be assigned to multiple partitions     e The user should be set for    Local Partition Access Only      see page 17     e The remote keypads should only be assigned to a  single partition        To change to another partition  proceed as follows     Press    AREA ARMED        ir 35 34 25704    Enter partition C15   C45   e g  Press      to select Partition 2     Premier 816  17 35 38 2864
28. escue should be developed  This includes making  sure that those who are to perform the rescue can  promptly hear the fire warning signal     e  f the exit is above the ground level  an approved  fire ladder or rope should be provided as well as  training in its use     e Exits on the ground level should be kept clear  Be  sure to remove snow from exterior patio doors in  winter  outdoor furniture or equipment should not  block exits     e Each person should know of a predetermined  assembly point where everyone can be accounted  for i e  across the street or at a neighbour s house   Once everyone is out of the building  call the Fire  Services     e A good plan emphasises quick escape  Do not  investigate or attempt to fight the fire  and do not  gather belongings or pets as this wastes valuable  time  Once outside  do not re enter the house  Wait  for the Fire Services     e Write the fire escape plan down and rehearse it  frequently so that should an emergency arise   everyone will know what to do  Revise the plan as  conditions change  such as the number of people in  the home  or if there are changes to the building s  construction        20    INS141 5    Premier 412  amp  816 Master User Manual    Fire Safety  amp  Maintenance       e Make sure your fire warning system is operational  by conducting weekly tests  see    Fire Alarm  Operation    on page 20   If you are unsure about  system operation  contact your installing dealer     e We recommend that you contact your
29. eserve the  original settings  press Ges      The alarm system will automatically exit program  mode if no key is pressed for 60 seconds     To access the programming menu  enter your Access    code DDD and press followed by C9          Enter Access code    Then press Ge  then C95       Programming Menu  Enter Code  gt  7     pt All Zone lights lit and  07000000000 Ready light flashes    s             Enter menu command  DOO       A programming menu is selected by entering a two digit  menu code  On completion of each menu option  the  system reverts to the main programming menu  allowing  other programming menu options to be accessed     To exit the programming menu press the key  the  system will revert to normal operation     Programming Menu  Enter Code  gt  7                                   ir All Zone lights lit and       service O w   Ready light flashes       To exit programming mode     press Gen     Y    Premier 816 LCD shows banner text  12 45 59 2804 and time date              Zones    AamO O O O O O O O O OArmed    All zones clear and  service         Ready light on        Programming Text  LCD Only     Text is programmed in a similar way to mobile phones   Characters are selected by pressing the corresponding key  the appropriate number of times  to select a character on  the same key  press C    to move the cursor along      The table below shows the keys to use and the characters  that are assigned to them     Characters                lt                    
30. ess code may also be programmed for Global  Access  A Global Access code can be used at any keypad  and will allow you to arm and disarm any of the partitions  assigned to your code  Alternatively your code may be  programmed for Partition Access  A Partition Access code  will only allow you to arm and disarm the partitions that are  assigned to both the keypad and your code        INS141 5    About the Alarm System    Premier 412  amp  816 Master User Manual       Remote Keypads    One or more remote keypads will be installed throughout  the protected premises  usually one at each entry exit door   Each remote keypad is normally assigned to the partition  that it is going to control  A keypad can be assigned to more  than one partition  if required  global keypad      Keypad Types    The following keypad types are available     Premier RKP4  The Premier RKP4 is styled around the  Premier RKP16  This remote keypad has 4 zone indicator  lights and is designed for use with the Premier 412 control  panel     Premier RKP8  The Premier RKP8 is styled around the  Premier RKP16  This remote keypad has 8 zone indicator  lights and is designed for use with the Premier 816 control  panel     Premier RKP16  The Premier RKP16 has 16 zone indicator  lights and is designed for use with the Premier 412 and  Premier 816 control panels when expanded to 12 and 16  zones respectively     Premier RKP16 Plus  The Premier RKP16 Plus has all the  features of the standard Premier RKP16 plus dedicate
31. g    seereis 20   Maintenance      Inr MX          Installation Records    Control Panek 2 5  uu suu Ce mms URL uns  KCY DAS                                Timers      T T       DO NOT REMOVE COVER    MAINS VOLTAGES INSIDE    No user serviceable parts  servicing by qualified  personnel only           INS141 5    Premier 412  amp  816 Master User Manual    About the Alarm System       1  About the Alarm System    Introduction    Your alarm system consists of a control panel  one or more  keypads and various detectors and sensors  The control  panel will normally be mounted out of sight in a utility room  or basement etc  The control panel houses the system   s  electronics and stand by battery  There is normally no  reason for anyone except an installer or service person to  have access to the control panel     The remote keypad is used to send commands to the  system and to display the current system status via the  various coloured lights  LED   s   The keypad also provides  audible feedback each time a key is pressed  Each keypad  will be mounted in convenient locations inside the protected  premises  near designated points of entry exit     Read this manual carefully and have your installer instruct  you on your system   s operation  Become familiar with the  features that have been implemented on your system  All  users of this system should be equally instructed in its use     About this Manual    This manual is a thorough explanation of all system  functions  including 
32. lst attempting to Away arm the system      gt    To auto Stay arm your alarm system proceed as follows     Enter Access code DDD     me Pen VES to Arm   2068606660 i MENU for Ortions    Press Press    feos a an Please Exit   Da UE M Marie 17 30 21 28784    The Armed light will flash and the exit tone will sound           Do NOT leave the premises during the exit delay  At  the end of the exit delay the alarm system will Stay arm     Changing from Delayed to Instant Stay    When Stay arming the system the delayed zones  front door  etc  are normally delayed  i e   when a delayed zone is  violated it will start the entry delay timer  However  it is  possible to change the delayed zones to instant when the  system is in a Stay armed mode  If a delayed zone is  violated when the system is in the  Instant Stay  mode the  system will generate an alarm immediately        To change from Delayed Stay to Instant Stay  proceed  as follows     Ensure that the system is Stay armed     Press and hold the key until you hear the  confirmation tone     m pu INSTANT STAY  mob 6660 6 6 bem 17 30 21 28 04    The Armed light will flash quickly   The system is Instant Stay armed        pA If the system is fitted with a Premier RKP16 Plus the  Instant light will also illuminate        INS141 5    Operating the Alarm System    Premier 412  amp  816 Master User Manual        gt    To change from Instant Stay to Delayed Stay  proceed  as follows     Ensure that the system is Instant Stay armed     Pre
33. more zones are bypassed the Ready  light will flash and if the system is fitted with a Premier  RKP16 Plus or Premier LCD LCDL then the Bypass  light will also illuminate     Unbypassing Zones    To manually unbypass zones  perform the manual Bypass  procedure on a zone that is already bypassed     e 24 hour zones cannot be unbypassed if they are still  violated     e lf your installer has enabled the    Reinstate Bypassed  Zones on Disarm  option  all zones will automatically be  unbypassed each time the system is disarmed     Group Bypass   The Group Bypass feature allows you to bypass a  predefined group of zones  The alarm system has up to four  groups        INS141 5    Operating the Alarm System    Premier 412  amp  816 Master User Manual          To bypass a group of zones  proceed as follows     Enter Access code DD    m TE    VES to Arm   ete             ees MENU for Ortions    Enter bypass group C1     C followed by       AO O O       O O O O           A Burass Zone  m  service    dee Zone Bi Burassed       Burass Zone  BB  Zone B4 Burassed    The keypad will display the bypassed zones   If required  zones can be added or removed from the  group by entering the required zone number DO   e g  Enter OD to add Zone 5     I 5     num O                          O  Burass Zone  895   service    rc Zone Bi Burassed  Burass Zone  95  Zone B4 Burassed  Burasi Zone  m  Zone B5 Burassed    The selected zone is now bypassed  Repeat step 3 to  bypass additional zones        Once
34. nes are scrolled  the relevant zone lights on in sequence on LCD keypads  LED Keypads       ex If any unbypassed zones that are not enabled for   Force Arming  are violated at the end of the exit  delay this is termed an exit error and the alarm system  will go into fail set state  internal alarm   If  programmed by the installer the external bell will also  sound  Enter a valid user Access code to silence this  alarm     A zone will only be armed when ALL associated  partitions are armed but will be disarmed when ANY  associated partition is disarmed     Away Arming    The Away arming mode is normally used when leaving the  premises  When the system is armed in this mode all  detection zones assigned to your partition s  will be armed     The Ready light must be on steady before the alarm system  can be Away armed        To Away arm the alarm system proceed as follows        Enter Access code CCC  es      VES to Arm   Seas SENATE EHE      PEHLI for Ortions  Press Press       EE D i Please Exit      E QNA MM 17 38 21 2804  The Armed light will flash and the exit tone will sound     Leave the premises  when the system has armed the  exit tone will stop  The system is now Away armed     worm lf the Quick Arm feature is enabled  you can omit step  1 from the above procedure     Stay Arming   The Stay arming mode is normally used when the premises  will be occupied  When the system is armed in this mode all  Interior detection zones assigned to your partition s  will be  bypassed
35. ns that are assigned to their code     User Options 3 C85C3  5    User Options 3 can be enabled or disabled for a selected  user so that the level of access to the system may be  altered  The following options are available     C15 Allow Engineer Code Programming   On  The Access code can access User 00  Engineer  in the  Program New Users menu  menu 80     Off  The Access code cannot access user 00 in the  Program New Users menu     C25 Allow NVM Locking   On  The Access code is allowed to lock unlock the NVM   providing  Allow Engineer Programming  is enabled    Once the NVM is locked the  Load Defaults  jumper  pins on the main control panel are disabled  thus  preventing the panel from being defaulted    Off  The Access code cannot lock unlock the NVM     C35 Allow Engineer Programming   On  The Access code can access the Engineer  programming menus    Off  The Access code cannot access the Engineer  programming menus     X45 Allow Test Call Transmission   On  The Access code can perform a test transmission to  the monitoring station  menu 92  see page 19     Off  The Access code cannot perform a test transmission     C55 Allow Alarm Fault Acknowledgement   On  The Access code can be used to acknowledge and  reset alarms and service faults    Off  The Access code cannot be used to acknowledge and  reset alarms and service faults      gt  Allow User Programming   On  The Access code can access the user program menus   menu 90   96     Off  The Access code cannot access the
36. ppliances and outlets in a safe  condition  Check for frayed cords  overloaded lighting  circuits  etc  If you are uncertain about the condition of  your electrical appliances or household service  have a  professional evaluate these units     e Are all flammable liquids stored safely in closed  containers in a well ventilated cool area  Cleaning with  flammable liquids should be avoided     e Are fire hazardous materials  matches  well out of reach  of children     e Are furnaces and wood burning appliances properly  installed  clean and in good working order  Have a  professional evaluate these appliances     Fire Escape Planning    There is often very little time between the detection of a fire  and the time it becomes deadly  It is therefore very important  that a family escape plan be developed and rehearsed     1  Every family member should participate in developing  the escape plan     2  Study the possible escape routes from each location  within the house  Since many fires occur at night   special attention should be given to the escape routes  from sleeping quarters     3  Escape from a bedroom must be possible without  opening the interior door  Consider the following when  making your escape plans     e Make sure that all perimeter doors and windows are  easily opened  Ensure that they are not painted shut  and that their locking mechanisms operate  smoothly     e  f opening or using the exit is too difficult for  children  the elderly or handicapped  plans for  r
37. r zones  except Fire  Tamper  and Trouble  are disabled during Zone Test allowing Audible  PA buttons  Silent PA buttons  etc  to be tested     Test Speakers  amp  Outputs Ma     This menu options allows you to perform the following tests   CD Test Speakers   C2   Test Bells   C3   Test Strobes   C Test System Outputs    A When performing the    Test System Outputs    option   only outputs programmed by your installer will be  activated during this test     Send Test Call DD    This menu options allows you to send a test call  transmission to your Alarm Receiving Centre     pA If the test call is unsuccessful  the keypad will sound  an error tone     Enable Download Engineer Access DGD  Your alarm system may be configured in such a way that  you have to authorise Download Engineer Access  Once  authorised  your alarm system will allow     e Your installer Alarm Receiving Centre to access the  alarm system via the remote downloading computer     e Your installer engineer to access the control panel  programming menus     The alarm system will allow access until 12 00am  after  which  both Download and Engineer Access will be denied       pqrs7PQRS  G  5tuv8TUV  QG 2wxyz9WXYZ   D Space 0       C    Move Left Right    Backspace  delete     Start Call Back DD    This option will cause the control panel to initiate a call back  sequence  This will allow the remote downloading computer  to remotely access the control panel     pA You should only use this feature when requested by  
38. ss and hold the key until you hear the  confirmation tone     DELAYED STAY  ir 38 21 25 64    The Armed light will flash slowly   The system is Delayed Stay armed     AamO O O O O O O O O Wama    Service O    Ready       PS If your system is fitted with a Premier RKP16 Plus the  Instant light will go off     Arming and Disarming Partitions    This section covers arming and disarming partitions  In  order to use these procedures the following requirements  must be configured     e The alarm system must be split into one or more  partitions     e Your Access code must be assigned to more than one  partition     e The keypad that you use to operate the alarm system  must be assigned to multiple partitions OR your Access  code is enabled for Global Access     Away Arming Partitions  This option allows you to Away arm one or more partitions      gt    To Away arm selected partitions  proceed as follows   Enter Access code DDD  hoe re a VES to Arm   Hune    ss T HEHU for Ortions  Press    oun VES to Arm   s dicte Ares  gt         lt           The Ready light will flash quickly   Press C1     C4   to select deselect partitions   e g  Press      to select Partition 2     AO O   O                       VES to Aem  y  nies    dene Area  gt         lt     Partition 2 is now selected        s    Press Press         t Ed Please Exit      55 NS D pr 17 30 21 Z  ZB4    The Armed light will flash and the exit tone will sound        Leave the area being armed  when the partition has  armed th
39. t all times     C35 Enable Open Reporting   On  The system will report an  Open  condition to the alarm  receiving centre when the Access code is used to  disarm one or more partitions    Off  The system will not report an    Open    status     Nore        panel will always send an open signal after an  alarm even if this option is disabled     X45 Enable Close Reporting   On  The system will report a  Close  condition to the  monitoring station when the Access code is used to  arm one or more partitions    Off  The system will not report a    Close    condition     C55 Enable User as Duress Code   On  The Access code will report a  Duress  condition to the  monitoring station when the Access code is used    Off  The Access code behaves normally     C65 Activate Door Strike Output   On  When a user Access code is entered  the output type   Door Strike  is activated for 2 seconds    Off  The user Access code will not activate the  Door  Strike  output     C75 Allow Global PA Fire Silence   On  Both the 2 Wire Smoke detector input and the Auxiliary  PA input  Auxiliary Input programmed as PA  are  treated as  Global  zones  i e  they are assigned to all  partitions  When an alarm occurs from either of these  inputs the user can silence the alarm for all partitions   but they can only reset the alarm for the partitions that  are assigned to their code    Off  When an alarm occurs from either of these inputs the  user will only be able to silence reset the alarm for the  partitio
40. that has one  or more detection sensors connected to it  motion detectors   glass break detectors  door contacts or shock sensors   A  single zone might be a room  a hallway or a door or window   Two or more of these zones will be linked together by the  control panel to form a partition     A partition is an area of the protected premises  A partition  can be armed and disarmed independently from other  partitions  All of the partitions together form the entire alarm  system  If your alarm system is not divided into partitions  then all devices will be assigned to Partition 1     Some zones may belong to more than one partition  such as  points of entry exit and hallways  These are called Global  Zones because they are not assigned to a single partition     The following table shows the number of zones and  partitions for the Premier 412  amp  816 control panels     4 12    Premier 412 2  Premier 816 4 8 16          Access Codes    As a user of the alarm system  you will be assigned a 4  5 or  6 digit Access code  Access codes are used to arm and  disarm the partition s  to which they are assigned  Some  Access codes can perform additional system functions   such as programming system options  bypassing zones and  performing system tests     Your Access code may not allow you to access certain  system functions  For instance  if your code is only allowed  to arm and disarm Partition 1  you will not be able to arm or  disarm other partitions  or the entire system     Your Acc
41. tly to the  remote keypad     en P Enter Your Code  m9 6 6660 6 6 8 umm GE  30 59 28704  Enter Access code DD  ros com Premier 516  10009068668      02 31 12 28704    The entry tone will stop and the Armed light will turn off   The alarm system is now disarmed           PS If a valid Access code is not entered before the end of  the entry delay  an alarm will occur     Disarming when not in Entry     gt    To disarm the alarm system when not in entry  proceed  as follows     Enter Access code DOME    pes pud          for Ortions  m9    6 6 6 6 6 wam HO to Disarm     Press       Press    es Fe Premier 816  0666666 66 0  17 38 21 28704    The Armed light will turn off  The alarm system is now  disarmed           cS If the system only has one partition you will not have  to perform step 2     If the Quick Disarm feature is enabled and the system  is Stay armed you can omit step 1 from the above  procedure     Disarming after an Alarm       To disarm the alarm system after an alarm  proceed as  follows     Enter Access code DDD           Bs Alm  1  21 18 56 28  zone BS Active  Master Bedroom    The system is disarmed and the keypads display the  source of the alarm     A                     Service O   Ready    The system must now be reset before you can arm again   see page 11 for details on resetting alarms     Auto Stay Arming    If your installer has enabled the Auto Stay feature the system  will automatically Stay arm if the entry exit zone  front door   is not activated whi
42. troubleshooting and programming  Access codes in addition to performing basic system  functions  Most users of the system will not need to know all  of this information  The section of this manual  titled     Operating your Alarm System    explains general system  concepts and instructs the user on how to arm and disarm  the system and bypass zones  The remaining sections of the  manual are reserved for more detailed system information     Fire Detection    This equipment is capable of monitoring fire detection  devices such as smoke detectors and providing a warning  alarm if a fire condition is detected  Good fire detection  depends on having adequate numbers of fire detectors  placed in appropriate locations  This equipment should be  installed in accordance with the relevant local authority fire  regulations  Carefully review the    Fire Escape Planning     guidelines in this manual     PS Your installer must enable the fire detection feature of  this equipment before it will work     Monitoring    This system is capable of transmitting alarms  troubles and  emergency information over telephone lines to an alarm  monitoring station  If you inadvertently initiate an alarm   immediately call the Alarm Receiving Centre  ARC  to  prevent an unnecessary response     PS Your installer must enable the monitoring function  before it will work     Zones and Partitions    Your installer has divided the protected premises into zones  and partitions     zone is an area of protection 
43. ve Top line scrolls active zones  Ho Zones Tested   Ames oes D gt  Fone Bi Tested         Bottom line scrolls tested zones      Activate Zones       Zone light flashing   zone active  service       Ready Zone light on   zone tested                    C   Press C0   to clear tested    zones from display    UI CAM UE  Aw O   O O O O O O O                        Test Speakers  amp  Outputs    Test Sastem Test Sustem System Tests  Enter 1 to 4  _  Enter Test Number L gt  Bells Active CD Test Speakers    D   C2   Test Bells       ime   E C3   Test Strobes     C Press C0   to reset test                C4   Test Outputs                   Send Test Call    Enable Download Engineer Access    Start Call Back    Program Time       Program Time  3 15 Enter the Time in 24hr format  e g  6 30pm   1830  C                Program Date       Enter the Date ina        O  C0  COI  CNDCY2CY  format  e g  28 April 2001     280401                Continues on  Next Page       18 INS141 5    Premier 412  amp  816 Master User Manual    System Program Menus       From  Previous Page        Banner Text  LCD Only                    Led Key      Off   e On     Slow Flash    Fast Flash             Premier 816   Premier 816 Text Editing Keys    I           2                G def3DEF    Use keys to enter edit text  ghl4GHI            Then press to accept  GD jkl5JKL       5 mno7MNO          Print 100 Events    Walk Test MO    The Walk Test feature can only be performed when the  partition is disarmed  24 hou
44. your installer Alarm Receiving Centre  If the Call Back  is unsuccessful the keypad will sound an error tone     Program Time COS    The control panel has a real time clock that is used to date  and time stamp events that are recorded within the system  log  The option allows you to set the control panel time     Program Date Ow    The control panel has a real time clock that is used to date  and time stamp events that are recorded within the system  log  The option allows you to set the date on the control  panel     Program Banner Text  LCD only  DD    If the system is fitted with either a Premier LCD or LCDL  remote keypad you can assign up to 16 characters of text to  the Banner Message  The Banner Message is displayed on  the top line of the LCD display during the normal disarmed  state  Text is programmed in a similar way to mobile  phones  Characters are selected by pressing the  corresponding key the appropriate number of times  to  select a character on the same key  press    to move the  cursor along   For details on entering text  see page 14     Print 100 Events DA  If your system has a printer connected  this menu option  allows the last 100 events in the system Event Log to be  sent to the printer        INS141 5    19    Fire Safety  amp  Maintenance    Premier 412  amp  816 Master User Manual       5  Fire Safety  amp  Maintenance    Fire Safety    Fire Alarm Operation   Alarm   On a fire alarm  the bell or siren will pulse ON and OFF  If  your system is fitte
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
ブーケアンケート 2009 - 若い女性オストメイトの会  Dell 370 User's Manual  Console File Converter User Guide  取扱説明書 UPS モニタ for Windows ユーザーズ・ガイド【インストール編】  Bruciatori di gas ad aria soffiata Gas-Gebläsebrenner    浴室暖房乾燥機 取扱説明書保証書付  Igenix IG4015 electrical kettle  Toshiba RAV-SM2242DT-TR Air Conditioner User Manual  RPDA 5 User Guide (April 2008)    Copyright © All rights reserved. 
   Failed to retrieve file