Home
SERVICE MANUAL
Contents
1. Zl OOF COOMMO cc SAFTY RECAUTIONS Read all of the instructions before using this appliance When using this appliance always exercise basic safety precautions including the following 1 Use this appliance only for its intended purpose as described in this uses and care guide 2 This freezer must be properly installed in accordance with the installation section Instructions before it is used See grounding instructions in the installation section 3 Never unplug your freezer by puling on the power cord Always grasp the plug firmly and pull straight out from the outlet 4 Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length the plug or the connector end 5 Unplug your freezer before cleaning or before making any repairs Note If for any reason this product requires service we strongly recommend that a certified technician perform the service 6 If your old freezer is not being used we recommend that you remove the door and leave the shelves in place this will reduce the possibility of danger to children 7 This freezer should not be recessed or built in an enclosed Cabinet is designed for freestanding installation only 8 Do not operate your freezer in the presence of explosive fumes 9 Do not refreeze foods which have been thawed complet
2. 5 Net weight kg 31 Packing dimensions H W D cm 89 62 5 58 5 Gross weight kg 34 20 container load pcs 76 40 container load pcs 152 40 High cube container load pcs 227 INATALLATION AND ACCESSORY PARTS Unpacking Your Freezer 1 Remove all packaging material this includes the foam base and all adhesive tape holding the freezer accessories inside and outside 2 lnspect and remove any remains of packing tape or printed materials before powering on the freezer Adjusting Your Freezer 1 Your freezer is designed for freestanding installation only It should not be recessed or built in 2 Place the freezer on a floor strong enough to support it fully loaded 3 When moving the freezer never tilt it more than a 45 degree angle This could damage the compressor and the sealed system 4 1 the freezer is tilted let it stand in an upright position for at least 24 hours prior to plugging This is to allow the refrigerant to settle e Proper Air Circulation e assure your freezer works at the maximum efficiency it was designed for you should install it in a location where there is proper air circulation e Plumbing and electrical connections e The following are recommended clearances around the freezer Do not over fill freezer for proper internal air circulation Electrical Requirement e Make sure there is a suitable power Outlet with proper grounding to power the freezer Avoid the use of cutting off the third grou
3. 8950 resp 8953 Energy consumption year from gt to Energy consumption EN153 24 h Cooling system K Compressor A Absorbtion Maximum noise level kg 24h kWh year h cm C kWh year KWh 24 h dB A CHEST FREEZERS P Newlll Haier Chest Freezer FS ST CE GS 104 103 9 240 13 Manual R600a C P 220 240 50 75 0 8 150 155 lt 18 240 0 66 K 45 Chest straight edges Colours Cabinet white Top white Door glass Door frame white Fascia panel Handle w b g s white white pocket Inside door drawers W white T transparent Product classification Super eco Eco Standard Standard Lid Number Handle Lock 1 pocket Type of lid Hinge Counter balanced Sliding Hinge plastic Inside walls Stainless steel Aluminium Synthethic RE Aluminium mat Insulation Lid thikness cm 7 Walls thikness cm 6 5 Baskets number n 1 metal Defrost drain Interior light Calendar Adjustable thermostat Fast freeze lamp yellow light Breakdown light red Fast freeze switch Freezer temperature warning indicator LED by sound Thermometer Outside In partition Maximum loading level marking adjustable Adjustable feet front rear n feet Mobility wheels front rear n Flush back skin evaporator Unit dimensions H W D cm 84 5 57 55 Height with open lid cm 134
4. Compressor efficiency is reduced 8 The drying filter is blocked 1 Check if there is short circuit and solve it if not change capable fuse 2 Check and connect tightly or change 3 Use till voltage rises to rated value or attach a stabilizer 4 Rotate the knob to wanted position for suitable temperature 5 Change the controller 6 Change starting thermal protection unit 7 Measure using RX1 position of avometer if there is wire broken change compressor 8 Change compressor relay 9 Change compressor 1 Adjust and make it close to evaporator cover 2 Change the temperature controller 3 Reduce them 4 Put the freezer to suitable place and make air circulate well 5 Remove frost regularly 6 Check or supplement refrigerant Change compressor 8 Change new drying filter 1 The knob of temperature controller has 1 Change the position to runs without been to over cooling position moderate stop 2 The contacting point of temperature 2 Repair or change temperature controller is adhered in freezer is temperature sensing probe of 3 Adjust to suitable position too low controller is not placed well and causes normally contact tightly with maladjustment evaporator cover 4 Compressor efficiency reduced 4 Change compressor Compressor 1 Supplement a stabilizer buzzes and 1 Voltage is too low adjust to rated value cannot be 2 Change starting
5. In these cases it is normal that the red indicator light goes on It goes off automatically when the interior temperature reaches approximately 15 yellow SUPER FREEZE SWITCH The compressor continues cooling until the SUPER FREEZE switch is turned off again SYSTEM FLOW CHART R 7 N 6 1 Er R PN M e Sy ff NU AU 1 r I 1 D U J WASZ VN X GH an T VA LOT L i y CA KZ AU NU The refrigeration system of direct cooling single system freezers belongs to the category of a single temperature and single control refrigerating system with only one evaporator and is controlled by a single temperature control SYSTEM FLOW SCENOGRAPH CIRCUIT DIAGRAM 1 Brief principle diagram CIRCUIT DIAGRAM FAT FF IE aa vel oj Lig I XP POWER PLUG M COMPRESSOR RT STARTER Hyg YELLOW LAMP HRD RED LAMP Hon GREEN LAMP F MOTOR PROTECTOR SAT THERM OSTAT Brief description of principle about Thermostat When the temperature in the freezer is higher and reaches the value for starting the machine the thermostat will be closed the compressor will run When the temperature in the freezer is lower and reaches the value for closing the machine the thermostat will be open thus the c
6. glass door has beer closed well dirt and put on a little talcum power Whether the glass door door sez bar is too dirty or sealed wel Sincere Forever Haier Group Tel 86 532 88938356 Web site htitp www haier com
7. infinite or Q Whether the starting current is Inner thouble of about 5A compressor If it is infinite or N 0 then the starter 15 out of work resistance between running jack and starting jack is 16 ether compressor pin 1S tight contact is good Insert again electrify and test ether input and voltage of main control board Main control board 15 out of work Whether each contact of mam control board is normal Compressor doesn t start sometimes because the temperature in case is between starting and stop temperature should pay attention when to test frighten each contact and tes machine again MOU TROUBLE SHOOTING 2 Poor cooling Poor cooling eck the diaplay temperature rember whether it is setted at 18 Change to lower vhether the rear side and topi too close to the wall Avoid these N matters which will affect heat radiation of condenser and Y reduce refrigeration ability Whether the cellar is under sunlight directly vhether the cellar is near ther source Whether the room temperature is too hoot or not Frequent opening and extended opening of glass door will reduce refrigeration ability by cloth pieces or paper or dirt or Whether the
8. or change cushion 6 Change compressor 1 Check leakage make welding repair and fill refrigerant again 2 Clean the capillary or change filter Frost at 1 There is some leakage of refrigerant 1 Check leakage make welding evaporator is 2 There is dirt block but not serious repair and fill refrigerant again 1 There is serious leakage of refrigerant 2 There is dirt blocked the capillary or system There is no frost at evaporator not full 3 Refrigeration quantity of compressor 2Clean the capillary and filter is reduced 3 Change compressor Evaporator frosts too rapid frost 1 Food put into freezer contains water layer too thick 2 much food has been stored or frozen to ice Electricity 1 Freezer body has not been connected leakage of tothe ground freezer body 2 compressor terminal contacts body you will feel shell and causes short circuit tingle when 3 When the components of electrical touching system get wet insulation ability is hand dropped electricity leaks 1 Environment temperature too high or insulation ability of insulator is dropped 2 There is short circuit between fan coils or the fan coil is burned The blade of fan is blocked or fan Fan too noisy Supporter Is loose 2 of fan axle is too big Electricity leakage of fan The fan 1 Check if any connection has come off doesn t run Check is the fa
9. CAUTION m READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE Chest Freezer SERVICE MANUAL MODEL BD 103GC m Features 1 Deep and quick freezing 2 Square cabinet and square lid 3 Mechanical temperature control with power indicator 4 High pressure foam cover for efficient Temperature preservation 5 Eximious water disposal device 6 Wide climate zone design Haier Group CONTENTS CONTENTS deta seed a a e aa AO ak SAFTY PRECAUTIONS 2 ona lee el aa EE tw SPEGIFIC ATIONS twoi id a enedes INATALLATION AND ACCESSORY PARTS IDENTHFICAHONS Gai lat xc o d b R Pk o DISASSEMBLY micra ab ROLE de C W FUNCTION SCHEDULE 2 wa dawca do Give eee SYSTEM FLOW CHART ec s zd a i dowi odka dada SYSTEM FLOW SCENOGRAP Pievicsinecevsiscwnesccdsiwtnwweecisecantnawneanssacaucwncsuncecains CIRCUIT DIAGRAM 5 Te EE ONCE NORMAL PROBLEMS Ea Alo Gap R FROUBEE SHOOTING r o L GCOMprESSOFAOESN
10. ely 9 Do not use any electrical device or any sharp instrument in defrosting your freezer 10 WARNING Keep ventilation Openings in the appliance enclosure or in the built in structure clear of obstruction WARNING Do not use mechanical devices or other means to accelerate the defrosting process other than those reconnended by the manufacturer WARNING Do not damage refregerant circuit WARNING Do not use electrical appliances inside the food storage compartments of the appliance unless they are of the recommended by the manufacturer SPECIFICATIONS Superfast freeze function Adjustable temperature control with power indicator High pressure and microbiological foam filled door for energy conservation convenient water drain Hi temp indicator castors External controls O HFC 0 Comply with RoHS Commercial brand Product description Type of appliance FS free standing Bl built in Energy efficiency class N 16 32 C ST 16 38 C T 18 43 C Freezer star rating Approvals VDE TUV IMQ NF OVE DEMKO etc Certifications Climate class Gross capacity Total net capacity Freezing capacity kg 24h Energy consumption year Max storage time at breackdown Defrosting Manual Automatic R134a R600a R141b C P Kind of coolant Foaming components Voltage frequency Input power currency Lenght of cable incl plug Temperature range DIN
11. g the unit For draining place a tray beneath the outer drain plug Pull out the drain dial and rotate it so that the arrow points down ward This will let the water flow out into the tray e Remove the drain plug from the inside of the freezer Defrosting usually takes a few hours To defrost faster keep the freezer door open When done push the drain dial in and turn the arrow to the up position Re plug the drain plug inside the freezer compartment Note monitor the container under the drain to avoid overflow e Wipe the interior of the freezer and replace the electrical plug in the electrical outlet e Rest the temperature control to the desired setting PARTS IDENTIFICATIONS Control panel DISASSEMBLY Assembly and disassembly should be done after the plug is pull out of the socket 2 It should be down as instructed in the Explosive Review 3 Disassemble the Compartment grill With the crossed screwdriver to turn the screw in a anticlockwise manner it could be disassembled easily 4 Disassemble the compressor cover With the crossed screwdriver to turn the screw in an anticlockwise manner and take it out from the lower left to the upper right Disassemble the control panel stretch your arm into the compartment push the connector inside when the clip falls off the cabinet take off the control panel and the connective wire cord with an acutilingual plier Disassemble the thermostat take off the kn
12. n is burned Electricity The service time is too long leakage of temperature The environment is too dirty controller Humidity is too high There is leakage of temperature sensing medium 2 Damage of cam of contacting point spring etc Temperature controller out of order The probe of temperature sensing tube doesnt contact evaporator lt has not been mounted to position or changed during transportation well 1 Please let or make food dry after cleaning then store it 2 Store only corrects quantity of food 1 Make the ground connection as stipulated 2 Change compressor 3 Check carefully step by step if insulation is seriously damaged please change remove wet parts and put them into drying box to make them dry 1 Change fan 2 Change fan 1 Clear obstacles around the fan or tighten the supporter 2 Change the fan 1 Change the fan 2 Change the fan 1 Change temperature controller 2 Use brush to remove dust 3 Make the temperature dry and control the environment humidity Change temperature controller Mount it again TROUBLE SHOOTING 1 Compressor doesnt start Comprssor doesn t start Y Change a new control panel and test CE di Lower the setting temperature is higher then environment temperature and test Compressor is open circuit or short Circuit ompessor is
13. nding this is a dangerous practice since it provides no effective grounding for the freezer and may result in shock hazard Install Limitations e Do not install your freezer in any location not properly insulated or heated e g garage etc Select a suitable location for the freezer on a hard even surfaces away from direct sunlight or heat source e g radiators baseboard heaters cooking appliances etc Any floor unevenness should be corrected Operating Your Freezer Once the freezer is in its proper place plug it in an electrical outlet having 230 volts set the temperature on the temperature contrail knob min being the warmest and max being the coldest Initially set the temperature on medium Place food inside the freezer After using the freezer for 24 hours set the freezer to your desired setting In case you unplug your freezer or experience an electrical outage allow 5 Minutes before plugging it back in Note If the freezer has been placed in a horizontal or tilted position for any period of time wait 24 hours before plugging the unit in Food Storage Basket Your Freezer has 1 or 2 removable basket It allows you to store food more accessibly or you can remove it if not needed Defrosting and Draining The Freezer e Defrost whenever the frost becomes 5MM thick Never use a sharp metallic instrument to remove the frost as it may damage the cooling coils A punctured coil will void the warranty eunplu
14. ob of the thermostat and turn the nut anticlockwise with a pinchers clamp then it could be moved Disassemble the hinge assembly and the hinge cover screw off the two screws on the hinge cover take away the cover then screw off the eight screws on the bottom hinge so the whole hinge could be moved 9 away the compressor First take off the compressor cover and the wire cord Open the pipe with the plier to let out the coolant then pull out the discharge and the suction after heated by gas jointing Q Disassemble the compressor sole plate turn off the four screws of the compressor sole plate with a cross screw anticlockwise then take away the plate from the sideway Function Schedule Adjustable temperature dial Your freezer will automatically maintain the temperature level you select The temperature level you select Min is the warmest is the coldest We recommend a medium setting Do not adjust your freezer frequently green CONTROL The green control light must always be on when the is very important to pay attention to this because in the appliance is connected to the mains and switched on It event of a power failure the red and yellow lights stop operating and do no longer provide a warning red ALARM lf the red indicator light goes on there may be several reasons for this namely First start up of appliance Restart after defrosting Filling freezer with fresh food
15. ompressor will be stop running CIRCUIT DIAGRAM 2 Connect diagram BU Ey Red light light Yellow light j Thermostat compressor Notice BN brown BU Blue BK Black GNYE Kelly RED Red Normal problems Compressor can not be started Compressor Starts too frequent operation time too long but temperature drop In freezer is too slow 1 Fuse is broken 2 The contact of plug socket and cable is not good Cable broken 3 The voltage is too low 10 15 less than rated voltage 4 The knob of temperature controller is at rest position 5 The temperature controller is out of order 6 Starting relay or thermal protection unit is out of order or broken 7 Wire broken of motor starting coil or operation coil 8 The compressor motor is burned or rotator and stator are blocked to dead 9 There is leakage of high pressure gas valve or the shaft is embraced to dead 1 The distance between temperatures sensing tube of temp Controller and evaporator are too big 2 The temperature controller is out of order 3 Food stuffs in the freezer too much door opens too frequent and open time too long 4 The environment temperature is too high humidity too high airflow is impeded 5 The frost layer at the evaporator is too thick 6 The refrigerant is insufficient or leakage 7
16. relay started 2 Starting relay out of order 3 Change compressor thermal 3 The starting coil of starting motor is protection broken 4 The shaft and piston in the unit jump 4 Compressor does not run compressor is blocked please repeatedly change 1 The voltage is too high 2 Over load protection unit is not good it jumps earlier 3 Starter contacting point is adhered 4 There is short circuit in compressor 5 There is mechanical problem in the compressor 6 Temperature around compressor is too high 1 The floor is loose 2 The freezer body is not stable and in level When compressor runs friction between tubes and freezer body causes resonance 4 Compressor fixing screw is loose 5 The vibration absorption cushion for compressor fixing is too tight or too loose or ageing 6 Compressor inside noise 15 too big or vibration absorption suspending spring is broken 1 Supplement a stabilizer and adjust its value to rated 2 Change over load protection unit 3 Change starting relay 4 Change compressor 5 Change compressor 6 lncrease heat radiation space After short time of operation over load protection unit cuts off 1 Reinforce the floor 2 Make the freezer body stable 3 Move the tube a little away to TOO much avoid friction noise when compressor runs 4 Make the tight 5 Adjust the degree of tight or loose of vibration absorption cushion