Contents

1. 6 Protect the power cords from being walked on Protect cords from being pinched or sharply bent particularly where they connect to the power outlet the power supply unit and the device Do not jerk knot sharply bend or otherwise abuse the power cords Do not expose the power supply or power cords to sources of heat Keep children and pets away from the power cords Do not allow them to bite or chew on the cords When disconnecting the power cords pull on the plug Do not pull on the cord lf a power cord or power supply becomes damaged in any way stop using it immediately Unplug your device during lightning storms or when unused for long periods of time Always connect the power supply according to the following instructions 1 2 3 fo CADScan Plug the AC power cord into the power supply Plug the DC power cord into the scanner Plug the other end of the AC power cord into the wall socket Copyright Cadscan Limited 2014
2. to increase quality but at a cost of speed 6 Once the desired settings have been chosen click scan Duti JD canne UBIKG 3DSCANNER Not connected This will now activate the scanner and your object will be scanned Do not open the lid during scanning as this will adversely affect scan quality Once complete a window will open displaying your scanned object fo CADScan Copyright Cadscan Limited 2014 To scan a small object Macro Mode You can adjust the position of the turntable and upper scanning head in your CUBIK system to scan smaller objects This configuration creates higher quality scans and is known as macro mode The adjustable parts are shown in the diagrams below Knobs to adjust the top scanning head Knobs to move the turntable fo CADScan Copyright Cadscan Limited 2014 To configure macro mode 1 Loosen the turntable Reach into the scanner and loosen the knurled knobs on either side of the turntable shown in the image above 2 Use the two finger hooks on either side of the turntable to push the turntable forward toward the scanning heads 3 Loosen the upper scanning head The upper scanning head is held in place by four knurled knobs two on either side Slightly loosen these knobs until the scanning head is loose being careful not to remove them completely Knurled a 7 knobs Hockey stick shaped slots a fo CADScan Copyr
3. d 3DSCANNER User Manual fo CADScan Copyright Cadscan Limited 2014 What s in the box Your CUBIK 3D Scanner comes with all the parts you need to get started straight away Your box contains e CUBIK 3D Scanner x 1 e USB Cable Type Ato Type B x2 e IEC Power Cable Country Specific x 1 e Power Adapter x 1 Spares and replacements are available If needed please contact info cad scan co uk IMPORTANT ONLY USE THE CABLES THAT ARE SUPPLIED WITH YOUR SCANNER TO AVOID DAMAGE TO THE EQUIPMENT fo CADScan Copyright Cadscan Limited 2014 Setting up your CUBIK 3D Scanner The rear of the scanner has the following connectors shown in the diagram below e USB Connector x2 e Power Connector x1 USB Connector Power USB Connector 1 Connector 2 1 Download and install the CADScan CUBIK software This software is available from www cad scan co uk 2 Connect USB connectors 1 and 2 to your computer Please wait for the device to be recognised pop up window will appear while the drivers are installed This process may take a few minutes 3 With the power supply unplugged connect the power adapter to the scanner Do not turn on the power before connecting the power adapter to the scanner 4 With the IEC power cable unplugged connect the IEC power cable to the power adapter 5 Connect the IEC power cable to the wall outlet fo CADScan Copyright Cadscan Limited 2014 Scanning your fi
4. ight Cadscan Limited 2014 4 Holding on to the knobs on either side of the scanning head lift the scanning head up and over the half loop then slide it down the hockey stick shaped path until it comes to rest at the bottom Be careful not to let the scanning head fall 5 Tighten the four knobs to fasten the upper scanning head into place 6 Follow the instructions from the previous section above to complete the scan To return the scanner to normal mode 1 Loosen the four knobs holding the upper scanning head 2 Lift the upper scanning head up the hockey stick shaped path and over the half loop at the top The scanning head should come to rest with a click 3 Tighten the four knobs to fasten the upper scanning head into place fo CADScan Copyright Cadscan Limited 2014 Troubleshooting Problem Cause Solution Turntable does not rotate Power supply is not connected Connect the IEC power lead to the power adapter connect the power adapter to the scanner and then finally connect the power adapter to the wall Scanner case does not close properly There is a small chance that the lid may become misaligned with the rest of the case especially if the unit has been handled roughly Open the lid then carefully close it making sure that both sides mate with the case scans of matt black or very shiny objects show errors Some matt black objects do not reflect enough light t
5. is not in use you may need to disconnect all cables from the front and rear of the product to keep them out of the reach of children and pets Do not allow children to play with cables and cords AC powered devices These precautions apply to a product that plugs into a standard wall power outlet Failure to take the following precautions can result in serious injury or death from electric shock or fire or in damage to the device To select an appropriate power source for the device 1 Use only the power supply unit and AC power cord that came with your device 2 Use of any alternative power supply or cord may damage the device 3 Confirm that your electrical outlet provides the type of power indicated on the power supply unit in terms of voltage V and frequency Hz If you are not sure of the type of power supplied to your home consult a qualified electrician 4 Do not use non standard power sources such as generators or inverters even if the voltage and frequency appear acceptable Only use AC power provided by a standard wall outlet 5 Do not overload your wall outlet extension cord power strip or other electrical receptacle Confirm they are rated to handle the total current in amps A drawn by the device indicated on the power supply unit and any other devices that are connected to the same receptacle fo CADScan Copyright Cadscan Limited 2014 To avoid damaging the power cords and power supply 1 2
6. o be imaged by the scanner Very shiny objects reflect too much light making them appear further away to the imaging system Coat the object in a layer of chalk spray This is a safe non permanent coating which can simply be wiped away after use fo CADScan Copyright Cadscan Limited 2014 Important Safety Information Read this guide for important health and safety information that applies to the CUBIK 3D Scanner that you have purchased Warning Failure to properly set up use and care for this product can increase the risk of injury to personnel or damage to the device Read this guide and save it for future reference Do Not Attempt Repairs Do not attempt to take apart open service or modify the scanner or power supply Doing so could present the risk of electric shock fire or other hazard Evidence of any attempt to open and or modify the device including any peeling puncturing or removal of any labels will void the Limited Warranty Usage and Cleaning 1 Only use accessories specified by CADScan 2 Clean only with a dry cloth 3 Do not allow this product to become wet To reduce the risk of fire or electric shock do not expose this product to rain or other types of moisture Keep cables out of the way of people and pets Arrange all cables and cords so that people and pets are not likely to trip over or accidentally pull on them as they move around or walk through the area When the product
7. rst object Your scanner can be configured to scan large or small objects To scan a arge object 1 Open the scanner lid 2 Place the object on the centre of the turntable 3 Close the scanner lid fo CADScan Copyright Cadscan Limited 2014 4 Double click the CUBIK icon on your desktop to open the CADScan CUBIK software Please note that for the Beta release this will be an executable file in the folder where Cubik was installed The following dialogue window will appear E Cubik 30 Scanner og ak 5 Click the Settings Tab The following window will appear E Cubik 3D Scanner O ae 3DSCANNER 10 ON seu fo CADScan Copyright Cadscan Limited 2014 Three settings are available A Scan Resolution You can choose the resolution of the image captures made by the scanner Options available are low medium and high Low resolution scanning is fast while high resolution scanning offers four times the detail but is slower B Number of Turns The turntable rotates in steps so that each face of the object can be scanned to build up a full reconstruction of the object You can choose to have a small number of turns for higher speed or a high number of turns which takes longer but increases the accuracy C Noise reduction You can improve the quality of the scan by using our noise reduction algorithm This algorithm averages the pixel values over several images