User's Manual TR-77Ui

image

Contents

1. Start gt gt All Programs gt gt T amp D Recorder for Windows TR 5 7xU gt gt T amp D Recorder for Windows application A Accessories EC AAMC e Quick Start All Programs gt fag T amp D Recorder for Windows A Log off Disconnect T amp D Recorder for Windows is made up of two applications T amp D Recorder for Windows and Quick Start To get any necessary help go to the Help menu in T amp D Recorder for Windows as opened above click on Search by Topic to show the top window in which all of related topics are listed Contents Tab Index Tab Search Tab E Ti Recorder frr Windows delp T amp Hide Print Options Gork res Index Search T amp D Recorder P i t for Windows Help Hel Outline 4 Menu Win Launcher a ers E amp Copyrights and others Q Outline Search Tab Contents Tab By clicking on one of the topics listed you can find detailed information for that subject Index Tab By selecting a Keyword in the Keyword list and clicking the Display button at the bottom a detailed explanation will appear Enter the keyword you wish to search for and click the List Topics button All topics that contain the keyword will be displayed By selecting a Keyword in the Keyword list and clicking the Display button at the bottom a detailed explanation window will appear 22 Specifications Device Type TR 77Ui Number
2. Unit Button You can make or change the LCD display settings from the DISPLAY button on the front of the TR 77Ui Unit There are two LCD display modes for current readings Alternating Display and Fixed Display Alternating Display The LCD display shows Temperature and Humidity alternatingly in the following order Temperature C F gt gt Humidity gt gt Fixed Display The LCD display shows one measurement item specified by pressing the button on the Unit The factory default setting is an alternating display between Temperature and Humidity Example During an Alternating Display T By pressing the button Measurement Items _ when the Unit has been Temperature and Humidity x DAE aaa set to an Alternating i 5 Display the LCD display haic m mode will change to a Z ee Ent Fixed Display Press the button Fixed Display Temperature With each pressing of the CEB RE were button the item for a Fixed 1 D l is Display will change Press the button Humidity C22 onerim me 445 The LCD display mode will change to an Press the button Alternating Display Alternating Display 21 How to Open the Application and Help After software installation has been completed T amp D Recorder for Windows will be registered in the Windows Start Menu Click as follows to open Windows
3. ambient temperature is from 10 to 60 C and the humidity is 90 RH no condensation or less To prevent damage to the Unit from static electricity remove static electricity from your body by touching metal around you door knob window frame before touching the Unit Static electricity may cause not only damage to the Unit but may cause breaks in or a loss of data If the Unit is not to be used for a long period of time for safety reasons please remove the battery If left in the Unit it may leak and lead to malfunctioning Please take extra caution when plugging in and pulling out the USB plug while another USB device such as CDD or HDD is in operation It may cause problems to your CD RW or other device We shall not guarantee the operation of our device if you have connected it to your computer using a USB hub or a USB extension cable Please do not insert your fingers or any foreign objects into any of the devices jacks Do not use any other batteries than those that are specified in this User s Manual It may cause a fire or other trouble including malfunction Do not use or store the TR 77Ui Unit in any of the following places Doing so may cause electrocution fire and or other adverse effects to the device and or your computer Areas exposed to direct sunlight This will cause the inside of the device to become overheated and may cause fire deformation and or other damage including malfunction Areas prone to s
4. and using the product 1 Getting Ready provided in this manual 1 Install the software T amp D Recorder for Windows 2 Get the TR 77Ui ready to use 3 Install the USB device driver and confirm its usage 2 Making the TR 77Ui Unit Settings using supplied software Starting Recording 1 Make Settings for Device Names Recording Intervals and Recording Modes 2 Start Recording 3 Downloading Data Displaying Graphs 1 Connect the TR 77Ui with a USB communication cable to a computer 2 Download data via the Software 3 Display graphs via the Software For details about making TR 77Ui Unit Settings or about Downloading Data see the explanation in the Software User s Manual and or the Software Help What is TR 77Ui Thermo Recorder Outline TR 77Ui Thermo Recorder is a data logger capable of measuring displaying and recording temperature and humidity TR 77Ui has one temperature channel and one humidity channel The measuring accuracy of 2 5 RH enables more precise measurements and allows for measurement within a wider range The data recorded into the TR 77Ui Units can then be downloaded quickly via USB communication cable to your computer whereby with our exclusive software you can easily process the data into graphs tables save to files and or print it out to help you analyze that data Basic Functions Humidity Measuring Range 0 to 99 RH The TR 77Ui with the sensor
5. included in this package can simultaneously measure and record temperature in a range of 30 to 80 C and humidity in a range of 0 to 99 RH Data Recording Capacity 8 000 readings x 2 channels One channel can record and hold up to 8 000 measurement readings At the longest recording interval of 60 minutes recording can continue consecutively for one year Ten Months of Operation with just One AA Alkaline Battery Our low energy consumption design gives you ten months of continuous operation with only one AA alkaline battery This enables measuring and recording over long periods of time NOTE Battery life varies depending upon the type of battery the battery performance the measuring environment and the frequency of communication Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life Battery Life Warning Display When the battery power becomes low a battery life warning signal will appear in the Unit s LCD display If the battery power becomes even lower the Unit will automatically go into sleep mode in order to protect the data Data Protection Function When battery power becomes low a battery life warning signal will appear in the Unit s LCD display and if the battery power becomes even lower the Unit will automatically go into sleep mode in order to protect the data In sleep mode all normal operations
6. of Measurement Channels Measurement Items Attached Sensor 2 Channels 1 Temperature 1 Humidity Temperature Humidity 30 to 80 C 0 to 99 RH 2 5 RH at 25 C and 10 to 85 RH 4 RH at 25 C and 0 to 10 RH or 85 to 99 RH 0 3 C at 10 C Add 0 1 RH C When at other than Measuring Accuracy ace ae 25 C add to the accuracy noted above with Attached Sensor temperatures Hysteresis 1 5 RH or lower when used at temperature humidity equal to or lower than the following 50 C 75 RH 60 C 50 RH 70 C 35 RH 80 C 25 RH Measurement Display 01 C 0 1 RH Resolution i ae Platinum Sensor Recording Interval Recording Capacity Resistance Sensor Electrostatic Capacitance Type Select from 15 choices 1 2 5 10 15 20 and 30 seconds 1 2 5 10 15 20 30 and 60 minutes 8 000 readings x 2 channels Recording Modes ENDLESS ONETIME LCD Displayed Items Measurements Ch 1 only Ch 2 only alternating display Measurement and Recording Status Battery Life Warning Amount of Recorded Data Unit of Measurement Power 1 AA Alkaline Battery LR6 Battery Life 1 About 10 months Data Backup aa when battery power is low or when switch is off About 1 Interface 2 USB Communication Serial RS 232C Communication USB Communication Time When downloading 1 Unit of full data about 8 seconds Dimensions Weight of TR 77Ui Unit Operating Environment Att
7. R 77Ui User s Manual Published by T amp D CORPORATION Copyright T amp D Corporation All rights reserved 2010 01 1st printing This is printed on recycled paper Provisions for Free Repair If the Unit does not work properly despite the fact that the customer used it properly and in line with the User s Manual the Unit shall be repaired free of charge through the distributor which sold the Unit If the customer requests free repair because of trouble within the warranty period bring or send the Unit along with the warranty to the dealer A service charge may be added if a repairperson must be sent out to the place of use for repair If you have moved after purchasing or the product was received as a gift or there are difficulties contacting the shop from which you purchased the Unit please contact T amp D directly for service Free repair is not available in the following cases even though it is within the warranty period 1 Trouble or damage was caused by careless operation natural disaster fire public pollution or use of a power source other than specified 2 If repair adjustment disassembly or modification of the Unit has been carried out by a person other than a T amp D authorized engineer 3 Trouble or damage was caused by transportation movement or dropping of the Unit after purchase 4 Failure to submit the Warranty or failure to fill in all items required in the Warranty The
8. Thermo Recorder TR 77Ui User s Manual CE Copyright T amp D Corporation All rights reserved 2010 01 16504530001 1st Edition Notices about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and or other countries Windows Vista is either a registered trademark or trademark of Microsoft Corporation in the United States and or other countries Company names and product names are trademarks or registered trademarks of each company Specifications design and other contents outlined in this manual are subject to change without notice On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mistakes errors or unclear explanations in this manual T amp D Corporation accepts no
9. WER button OFF will appear in the LCD display and the Unit will turn off NOTE During recording the power cannot be turned off Please stop recording first and then press the POWER button to turn off the power Even if the power has been turned off the recorded data will be saved However if the battery power is totally lost all data will be lost so please download data as soon as possible to avoid losing any necessary data 17 18 Connecting the Sensor Connect the sensor to the sensor jack on the TR 77Ui Unit To avoid poor connections be sure to push the sensor connector securely into the jack The temperature humidity sensors included with the TR 72U and the TR 72W are not compatible with the TR 77Ui Make sure to use the sensor exclusively designed to be compatible with the TR 77Ui Starting Recording from TR 77Ui Unit Button By pressing the REC STOP button on the TR 77Ui Unit you can start a recording session immediately NOTE The Device Name Channel Name Recording Mode and all other recording condition settings must be made first via the computer using the software Start Recording Press in the REC STOP button on the front of the Unit until the REC mark appears in the LCD display When displayed recording has begun REC Mark lights up REC DATA com ENPLEss Mii NOTE By starting a new recording session all data currently saved in the Unit
10. Warranty cannot be reissued This Warranty only promises customers free repair within the period and conditions clarified in this Warranty Therefore the customer s legal rights will not be limited by this Warranty For further information on repair and others service questions after the termination of the warranty period contact your dealer Thermo Recorder R 77Ui Warranty Warranty period 1 year from date of purchase Customer s name Address Phone No Date of Purchase Dealer s name Address Phone No p Main Unit excluding sensors and any other options Object of Repair ludi d h Method of Repair Send in for Repair Free repair of the Unit will be carried out according to the details laid down in this manual only if the unit has broken down under normal usage as outlined in this User s Manual and during the stated warranty period Please contact your dealer about repair and present this document when seeking repair T amp D corporation Shimadachi 817 1 Matsumoto Nagano 390 0852 Japan Facsimile 81 263 40 3152 E MAIL support tandd com
11. ached Sensor H55xW78xD18 mm about 62 g including one AA battery Temperature 10 to 60 C Humidity under 90 RH no condensation HHA 3151 x 1 Accessories Included in Package AA alkaline battery LR6 x 1 USB Communication Cable x 1 US 15C length 1 5 m Software CD ROM Hardware User s Manual Warranty Software User s Manual 1 Battery life varies depending upon the type of battery the measuring environment the frequency of communication and the ambient temperature in which it is used 2 If necessary serial communication can be established by using our TR 77Ui communication protocol contact your local dealer to write a software program In this case it will be necessary to connect to your computer using our optional serial communication cable TR 07C Please contact your local dealer or the Sales Department of T amp D Corporation for details 23 24 Options Temperature Humidity Sensor HHA 3151 unit millimeters Cable Length 1 5 m L 65 L 1500 J r T iL K l D or ae z Materials Temperature Humidity Sensor Polycarbonate Vinyl chloride shielded wire Humidity Measurement Range 0 to 99 RH Temperature Measurement Range 30 to 80 C Humidity Measurement Accuracy 2 5 RH at 25 C and 10 to 85 RH 4 RH at 25 C and 0 to 10 RH or 85 to 99 RH Add 0 1 RH C When at other than 25 C add to the accuracy noted above Sensor Response Time Humidity About 21 s
12. al room temperature before using it again Do not expose the temperature humidity sensor to a strong impact This may effect measurements or cause damage including malfunction When the temperature humidity sensor is not being used please place it in the attached vinyl bag with the drying agent included and store it in a cool dark place with a temperature of between 15 to 30 C and a humidity of below 30 RH Before Using this Product Please be careful about the procedures when using this product with USB communication In order to use a USB connection to communicate between this product and a computer it is necessary to install the software and the USB device driver Before connecting this product to a computer with a USB communication cable it is necessary to first install the software and the USB device driver If you connect a TR 77Ui to the computer before installing the USB device driver may not be installed properly If you have connected a TR 77Ui to your computer before installing the USB device driver make sure to click the Cancel button in the Wizard window when it pops up on the computer display Then disconnect the USB communication cable from the TR 77Ui For more details about the proper installation procedure see the Software User s Manual that accompanies T amp D Recorder for Windows Basic Procedures The following outline shows the basic procedures for getting ready making settings
13. cting yourself and other people from bodily harm and or damage to property Explanation of Symbols Explanation of Warning Symbols These entries are actions that absolutely under DANGER circumstance should be taken The taking of such an action may cause serious personal physical damage or death These entries are actions that if taken may lead CAUTION to physical injury or damage to persons or things Explanation of Picture Symbols Denotes an important warning or caution Inside or near the symbol will appear another symbol giving details Ex stands for CAUTION AGAINST ELECTRIC SHOCK Denotes a forbidden action Inside or near the symbol will appear another symbol giving details EX stands for DO NOT TAKE APART Denotes an action that you must take Inside or near the symbol will appear another symbol giving details EX cA stands for UNPLUG POWER PLUG FROM OUTLET gt S o O 802o Sooo A DANGER Do not take apart repair or modify the Unit Doing so may cause fire or electrocution If water or a foreign body enters into the Unit immediately turn OFF the power remove batteries and stop using Continued use may cause fire or electrocution Do not use this Unit in wet or humid places such as a bathroom It may cause a fire or other trouble including malfunction Store the TR 77Ui Unit sensors batteries and communication cables out of the reach of children Touching them may cause i
14. displayed on the computer screen via the software if a Unit is connected to the computer with a USB communication cable If a Unit is left without a battery for some time all data may be lost so please work quickly when changing the battery When a battery life warning signal appears try to replace the battery with a new one as soon as possible 1 When it is time for the battery to be replaced a battery life warning signal will appear If at this time you change the battery recording will continue uninterrupted and all data will be saved for downloading 2 If the battery is not changed but it remains in use SLP will appear in the LCD display Recording will stop in order to protect recorded data until this point ca If you change the battery at this point it Lo Lm is still possible to download all saved Lo recorded data 3 If the battery is further left unchanged the display will automatically shut off and all previously recorded data will be lost About Battery Life A TR 77Ui Unit can be used continuously for about ten months with one AA Alkaline Battery Battery life varies depending upon the type of battery the battery performance the measuring environment and the frequency of communication 16 Turning ON the Power By holding in the POWER button at the left side the Unit will turn on A POWER Button 4 Turning OFF the Power By holding in the PO
15. econds 90 Temperature About 7 minutes 90 1 RH yr 0 1 C yr 1 5 RH or lower when used at temperature humidity equal to or lower than the following 50 C 75 RH 60 C 50 RH 70 C 35 RH 80 C 25 RH Sensor Temperature Durability 30 to 80 C Conditions for Use 19 Long Term Stability Humidity Hysteresis Do not expose to condensation dampness corrosive gases or organic solvents Sensor Extension Cable TR 1C30 unit millimeters Cable Length 3 0 m 3000 a Materials Vinyl chloride shielded wire NOTE It is possible to use up to three extension cables per sensor Serial Communication Cable TR 07C unit millimeters Connector Type Specialized Connector D sub9 pin For communication with computer Cable Length 1 5 m 1500 USB Communication Cable US 15C unit millimeters Connector mini B A plug For communication with computer 1500 7 1450 yO Ta i Cg Wall Attachment TR 07K2 unit millimeters Included Screw x 2 and Double sided Tape x 1 Compatible Device TR 77Ui Materials Polycarbonate 75 a i d 25 E For product information or questions contact us at T amp D corporation Shimadachi 817 1 Matsumoto Nagano 390 0852 Japan Fax 81 263 40 3152 E mail support tandd com Office Hours Monday to Friday 9 00 12 00 13 00 17 00 GMT 9 00 Tokyo Time Web Site http www tandd com Thermo Recorder T
16. ich adjustment settings have been written the original sensor s adjustment values will become invalid and the newly connected sensor s adjustment values will become valid 10 Package Contents The following items are included in the package TR 77Ui Unit x 1 DE m AA Alkaline Battery x 1 USB Communication Cable T amp D Recorder for Windows US 15C x 1 Software CD ROM x 1 L gt i SK Hardware User s Manual Warranty x 1 Software User s Manual x 1 TR 77Ui Appearance Diagram and Part Names Part Names and Functions FRONT Thermo Recorder TR 77U DISPLAY INTERVAL REC STOP Button Button Button DISPLAY Pressing this button will change the LCD display mode INTERVAL It is possible to make or change recording interval settings from this button on the Unit and view the currently set recording interval REC TOP Pressing this button will start or stop recording LEFT SIDE RIGHT SIDE p Sensor Jack Uag USB Cable Jack 1 POWER B lten i P Serial Cable Jack 2 j T7 i 1 Enable communication by connecting the data logger to the computer with a USB cable Before communicating via USB it is necessary to install the USB device driver After installing the USB device driver your computer will be able to detect and recognize any TR 77Ui Unit that is connected with a USB communication cable Fo
17. in display messages that appear on the LCD display FULL The data capacity is FULL Upon reaching capacity of 8 000 readings FULL will appear on the LCD display When this message appears recording has been stopped Only when recording in ONETIME mode will this be displayed DAA ower aa E F E E 2 ee es Sensor Error This will be displayed when a sensor has not been connected has not been completely inserted or the wire has been broken Measurement and recording will continue so battery power will be consumed cap 224 me ONETIME Cc SLP Sleep Mode If the battery power becomes extremely low this message will appear on the LCD display When this appears recording has been stopped in order to save the already recorded data See Changing the Battery on page 16 and change the battery ca cs ak JD 13 14 Nothing Appears If after going into sleep mode above the battery is further left unchanged the display will automatically shut off If that occurs all recorded data will be lost See Changing the Battery on page 16 and change the battery Installing the Battery 1 Remove the battery cover from the back of the Unit 2 Always use a new battery Insert one AA alkaline battery making sure that the and are in the correct direction 3 Replace and close the battery cover 15 Changing the Battery Besides the Unit s LCD display the battery level can be
18. njury and swallowing batteries is extremely dangerous If any smoke or strange smells are emitted from the Unit immediately turn OFF the power remove batteries and stop using Continued use may cause fire or electrocution Do not drop the Unit or expose the Unit to a strong impact If that happens to the Unit immediately turn OFF the power remove batteries and stop using Continued use may cause fire or electrocution This device is designed exclusively to measure and record temperature and humidity Do not use it for any other purpose than to measure and record temperature and humidity A CAUTION This Unit is not waterproof If the Unit gets dirty wipe it with a clean cloth and a mild detergent Harmful gases or chemicals may cause corrosion and or other danger to the Unit Also by coming in contact with hazardous substances harm may occur to the people handling the Unit Therefore do not use or store the Unit in any environment that is exposed to chemicals and harmful gases Battery life varies depending upon the type of battery the battery performance the measuring environment and the frequency of communication Battery terminals may provide insufficient contact due to age or vibration This may lead to data loss CO O S gt S gt Condensation may occur if the Unit is moved from one environment to another where the difference in temperature is great Use the Unit in an environment where the
19. ons may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING This equipment has been verified to comply with the limits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment You are cautioned that changes or modifications not expressly approved by party res
20. ponsible for compliance could void your authority to operate the equipment Contents Safety Precautions and Instructions 2 Before Using this Product nnnnnnnnnn G Basic Procedures 2 2 nnnnnnnnnnnnnnnnnnnnnnnnn 7 What is TR 77Ui Thermo Recorder 8 Package Contents nenenennnnnnnnnnnnnnnnnnnncnnncnnne 10 TR 77Ui Appearance Diagram and Part Names 11 Main Display Messages 13 Installing the Battery Changing the Battery 16 Turning ON the Power 17 Connecting the Sensor 18 Starting Recording from TR 77Ui Unit Button 19 Setting Recording Interval from TR 77Ui Unit Button 20 Changing the LCD Display Mode from TR 77Ui Unit Button 21 How to Open the Application and Help 22 Specifications 23 Options 24 Safety Precautions and Instructions To ensure safety be sure to obey all of the following warnings The following items should be strictly obeyed for the safe usage of this Unit and for prote
21. r details about how to install the USB device driver see Installing the USB Driver in the Software T amp D Recorder for Windows TR 5 7xU User s Manual 2 Serial Communication Cable is an Optional Accessory 11 12 LCD Display Channel Mark The Channel No of the measurement being displayed will appear Recording Mark The recording status will appear ON Recording in progress BLINKING Waiting for programmed start Data Capacity Scale After every 2 000 readings the scale will be marked from left to right COM Mark ON Connected via USB cable BLINKING Data is being sent or received In communication with the computer Recording Mode ONETIME Upon reaching capacity of 8 000 readings FULL will appear in the Unit s LCD display and recording will automat ically stop ENDLESS Upon reaching capacity of 8 000 readings the oldest data is overwritten and recording continues Battery Life Warning Signal When the battery power becomes low a mark will appear in the Unit s LCD display If the battery power becomes even lower SLP will appear and normal operations will stop Please change the battery as soon as the Battery Warning Mark appears Unit of Measurement The unit of the measurement C F for the display will appear Measurements and Messages Area Current measurements or operational messages such as FULL or SLP will appear Main Display Messages The following are the ma
22. responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our Unit Please be fully aware of this before using our product Some of our products which come under the category of strategic goods in foreign trade law need the permission of the Japanese government to be exported outside of Japan Please read the warranty and provisions for free repair carefully FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructi
23. trong magnetic fields This may cause damage including malfunction Areas exposed to water leakage This may cause electrocution or other damage including malfunction Areas exposed to excessive vibration This may cause injury malfunction damage or loss of proper electrical contact Areas near fire or exposed to excessive heat This may cause damage including malfunction and deformation Areas prone to smoke dust and dirt This may cause damage including malfunction A Cautions about using the Sensors When using the Temperature Humidity Sensor HHA 3151 please take note of the following S gt gt P e The sensor can measure temperature within the range of 30 to 80 C and humidity within the range of 0 to 99 RH Only use the sensor within these measurable ranges If extremely severe temperature changes occur the humidity measurements may appear abnormal Once the sensor s temperature becomes stable the measurements will return to normal During use the surface of the temperature humidity sensor will accumulate impurities dirt causing a decrease in the sensor s accuracy and sensitivity If the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor sooner This temperature humidity sensor is not waterproof If the sensor gets wet immediately remove the sensor from the Unit and wipe it with a clean cloth as soon as possible Then allow the sensor to dry in norm
24. will be erased Even if the Unit is waiting for a programmed start by pressing the REC STOP button until the REC mark appears you can start a new recording session immediately Stop Recording You can stop a recording session by pressing the REC STOP button until the REC mark disappears from the LCD display When it has disappeared recording has stopped DATA com ENPLESS Mii o cme REC mark disappears LILIES c 19 Setting Recording Interval from TR 77Ui Unit Button You can make or change recording interval settings from the INTERVAL button on the front of the TR 77Ui Unit 1 Press in the INTERVAL button on the front of the Unit until the recording interval appears in the LCD display 2 With each pressing of the INTERVAL button the recording interval time will change Press until the desired setting appears RATA es a ENDLESS IT IT ad h 15 seconds 15 minutes 3 When the desired recording interval appears stop pressing the INTERVAL button Within a few seconds the current measurement readings will return to the display and the setting will be finished By pressing the INTERVAL button during recording or while waiting for a programmed recording to start the currently set recording interval will be displayed During recording or while waiting for a programmed recording to start you cannot make recording interval settings 20 Changing the LCD Display Mode from TR 77Ui
25. will stop and it will become impossible to switch on the power of the Unit NOTE If the Unit remains in sleep mode for about 2 months without a change of battery or if the battery is left out of the Unit for more than 2 minutes all recorded data will be lost Current Readings Monitoring Display With our exclusive software you cannot only monitor the current measurements at a set interval but can view those measurements in a continually changing graph You can simultaneously display the current measurements and corresponding graphs for the number of Units you have connected 15 Recording Intervals Select from 15 recording intervals from 1 second to 1 hour to meet your needs Also there are two recording modes to choose from ONETIME and ENDLESS ONETIME Upon reaching capacity of 8 000 readings FULL will appear on the LCD display and recording will automatically stop ENDLESS Upon reaching capacity of 8 000 readings the oldest data is overwritten and recording continues Adjustment Function By entering the adjustment values beforehand it is possible to view and record the adjusted measurement values Adjustment values are written directly into the sensors themselves not into the Units Therefore when replacing a sensor it is necessary to re set any desired adjustment settings into the newly connected sensor Note that when replacing one sensor in which adjustment settings have been made with another one in wh