Home
User Manual - ATP Instrumentation
Contents
1. TypeK 200 C 1370 C 328 F 2498 F Range Type J 200 C 1100 C 328 F 2012 F 200 C 0 C 328 F 32 F 40 5 rdg 2 C 3 6 F TypeK 0 C 1000 C 32 F 1832 F 0 15 rdg 1 C 1 8 F 1000 C 1370 C 1832 F 2498 F 40 5 rdg 1 C 1 8 F Accuracy 200 C 0 C 328 F 32 F 40 5 rdg 2 C 3 6 F Type J 0 C 1000 C 32 F 1832 F 40 15 rdg 1 C 1 8 F 1000 C 1100 C 1832 F 2012 F 40 5 rdg C 1 8 F Resolution 0 1 C F lt 1000 1 C F gt 1000 AVG The average value for last 10 readings Power Supply 1x 9V battery Power Life At least 30 hours Operating 20 C 60 C 10 RH 90 RH conditions Storage conditions 20 C 60 C 10 RH 75 RH Dimensions 185 x 66 x 33 mm L W H Weight 245g 4 Meter Description D TA thermocouple sensor 2 T3 thermocouple sensor 3 T2 thermocouple sensor 4 T1 thermocouple sensor 5 LCD display 6 T1 T2 amp T3 T4 function button 2 Backlight button AVG button 9 HOLD button Power ON OFF button QD Set selection button 2 MAX MIN button 3 Units select button Va Tripod bush 15 Battery cover Battery cover screw 5 LCD Display Description D Min icon O i MAX 2 Max icon et i no nee G Low battery Icon j LI LUI 4 Temp units icon eI it 9 5 T1 T3 reading I I I HE 1 0 1 9
2. A 6 Temp units icon Data Hold icon 9 AVG icon Type K J thermocouple D Auto power off icon 2 T2 T4 icon 3 T3 T4 icon T1 T2 icon 5 T1 T3 icon Note When T1 T2 icon appears the 7 area displays the DIF value for T1 T2 When T3 T4 icon appears the DIF value for T3 T4 is displayed 6 Operating Instructions 6 1 Operating steps 6 1 1 Open the battery compartment install a 9V battery and close the battery compartment cover 6 1 2 Connect thermocouples 6 1 3 Power the meter on to start measurement Note 1 When the low battery icon 4 Ph appears replace the meters battery 2 Whilst measuring the tip of the temperature sensor must be fully in contact with the object being measured 6 2 Button Function 6 2 1 CT Button After powering the meter on press button to select the measuring of T1 T2 or T3 T4 Press and hold the button for 3 seconds to select K type or J type measurement Under measuring mode of T1 T2 press E button once T1 T2 icon will appear on the LCD display and the DIF value for T1 T2 will be shown at the T2 display area Press this button again to enter into T2 measurement mode Under measuring mode of T3 T4 press y button once T3 T4 icon will appear on the LCD display and the DIF value for T3 T4 will be shown at the T4 display area Press this button again to enter into T4 measurement mode 6 2 3 Button FFE After powering the meter on press E2 butto
3. User Manual Thermocouple Thermometer T H T MIN MAX L AM 258 TI SET Type K Please read this user manual thoroughly before using this unit and keep it for your future reference Contents 3 Specifications scie tt t nt beta bb tn bou te ata ttl 4 Meter Description seeren 5 LCD Display Description nene 1 A Satety Read the following safety information carefully before attempting to operate the meter Use the meter only as specified in this manual otherwise the warranty may be invalidated Environment conditions Altitude up to 2000 meters RHs90 Non Condensation Operating Temperature 25 C 70 C Maintenance Repairs or servicing should only be performed by ATP Instrumentation Ltd Cleaning Wipe the unit with a dry soft cloth Do not use abrasives or solvents on this instrument Safety Symbol Complies with EMC 2 Features This device is a contact thermometer with Type K J dual input It is widely used in safety and fire inspection plastic moulding asphalt marine printing ink and ink dryer temperature diesel and fleet maintenance Precise contact measurement Type K J dual input measurement Four measurements and dual displays Large LCD display with backlight MAX MIN AVG HOLD function C selection Auto power off 3 Specifications
4. cal atp instruments co uk www atp instrumentation co uk
5. n to turn the backlight on off The meter will be automatically powered off after 30 seconds inactivity 6 2 4 Button After powering the meter on press G button to freeze the current reading press it again to return to normal mode 6 2 5 Button Whilst measuring press lt button AVG icon will appear then the LCD screen will display the average of the last 10 readings Press this button again to return to normal mode 6 2 6 D Button Whilst measuring press button once to view the current MAX MIN reading Press and hold button for 3 seconds to return to normal mode 6 2 7 Button After powering the meter on press Ly button to select C or F 6 2 8 Button After installing the battery press button to power the meter on Press and hold this button for 3 seconds to turn the meter off 7 Notes Repairs or servicing should only be performed by ATP Instrumentation Ltd Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage Check if the thermocouple is well connected with the meter Plug the thermocouple into the meters thermocouple input jack 8 Accessories User manual Tripod Optional 9V Battery 4 Type K thermocouples ATP ATP Instrumentation Ltd Tournament Way Ashby de la Zouch Leicestershire LE65 2UU Sales 01530 566 800 sales atp instruments co uk Repair and Calibration 01530 566 804 _ techni
Download Pdf Manuals
Related Search
Related Contents
1129079-2-A 空間線量計 RADCOUNTER DC-200 Copyright © All rights reserved.
Failed to retrieve file