HW-CPP-01 User's Manual 1. Content Item Page Precaution before

image

Contents

1. with brilliant white main body and put this water storage tank cover upside down to assemble with the brilliant white main body the hole of water storage tank cover must be positioned and connected well with the water inlet of main body to avoid any water leakage during hydrotherapy irrigation operation Please refer to PIC 4 3 and PIC 4 4 PIC 4 3 Separate the transparent light PIC 4 4 The hole of water storage blue storage water tank cover with tank cover must be positioned and brilliant white main body connected well with the water inlet 5 Please put the machine on a stable and smooth table Before your first time operation please pour enough purified and sterilized water about 80 volume of water tank or 2 cm above the reference line indicated on the light blue transparent water tank as showing on the PIC 4 6 2 cm above Reference PIC 4 6 Pour water into the water tank about 80 volume of water tank 6 Set the stool steadier on the toilet and connect the anal tube L type tube together with stool steadier as showing on PIC 4 7 PIC 4 8 Press small black switch to PIC 4 7 Connect anal tube L type turn off the device meanwhile orange tube with stool steadier light will glow 7 Everything is now ready plug circuit breaker leakage power cord into wall outlet and instantly press turn off button small black switch at the head o
2. ON press big green bottom at center 3 3 Turn off button OFF press small bottom at side 3 4 Orange indicating light as showing OFF status 3 5 Ground wire green P2 4 Hydrotherapy Device 4 1 Transparent light blue storage water tank cover 4 2 Brilliant white main body 4 3 Water inlet for water container on main body 4 4 Machine base of main body 4 5 Power socket at the bottom of machine base 4 6 Water outlet at the bottom of machine base 4 7 Anti slip footpad at the bottom of machine base Ready assembly with No 4 5 4 7 water tank cover and Main body 5 Outlet pipe of Silicone 6 Stool Steadier 7 Anal Tube L type tube tube P3 4 Installation 1 Insert the circuit breaker leakage power cord into the power socket at the bottom of machine base of main body solidly as PIC 4 1 2 Insert one side of the outlet silicon tube into the water outlet at the bottom of machine base of main body as PIC 4 1 gently pull the outlet silicon tube to make sure it connect the water outlet well 3 Take another end of outlet silicon tube to connect with the accessory stool steadier which we will fix on stool for use later please refer to PIC 4 2 PIC 4 1 Insert the circuit breaker leakage power cord into the power socket Insert PIC 4 2 Connect silicon tube with stool one side of the outlet silicon tube into the steadier water outlet 4 Separate the transparent light blue storage water tank cover
3. pump has stopped running and the water stopped draining out press the Drain button on the panel once again to cut off the power and remove power cord from wall outlet for packing the device up PIC 5 6 Press drain button to drain PIC 5 7 Press for 3 seconds along the the remaining water off the Reset button on the panel of main machine body the device will be recovering 8 In the case of the red indicating light or Error is lighting on to recover the machine Please press the P8 small black button on the head of power cord or directly pull out the power cord plug from wall outlet to switch off the power and then turn on the power again after pressing for 3 seconds along the Reset button on the panel of main body the hydrotherapy device will be recovering If the machine is still not able to operate normally please do not use it and inform our customer service department for an arrangement of maintenance immediately 6 Troubleshooting Guide for Easy problem solving Indicating on panel 5 On P i Condition Debug instruction Pull out the plugs of leakage circuit X X X no power breaker of power cord and re insert to wall outlet l 1 Check that the water in water flashing a i h e Lighting X w o water outflow SOM et AS OMe 2 Switch the power off and turn on the power switch on again to restart the machine next press the Reset button for 3 seconds and check that flashing2 ae Bae Lighting X w o water outflow t
4. HW CPP O1 User s Manual 1 Content Item Precaution before use Machine Introduction How to use Installation Troubleshooting guide 2 Precaution before use 1 Please do not pour water which exceeds 381 into the light blue transparent water tank 2 It is recommended that filtered water is used or supplied from r o unit 3 Please do not turn the power on when the light blue transparent water tank is empty 4 Per use Please pour enough purified water to 2 cm above the line indicate on the light blue transparent water tank 5 Please operate the machine according to this instruction 6 please confirm that the power cord voltage is in correct range to your country between AC220V 240V 7 Please do not disassemble the machine by yourself and only contact your authorized agent 8 Consumer please review the detailed list of indications and contraindications for the use of this equipment if in doubt please seek medical advice from your doctor 3 Machine introduction 1 Remote control 1 1 Infrared emitter 1 2 On Off button 1 3 Drain button 1 4 Battery cover at rear 1 5 Battery compartment at rear Remote Control Front 2 Operation Panel 2 1 Power indicating light 2 2 In Operation indicating light J 2 3 Error indicating light 2 4 Outflow button 2 3 2 5 Drain button 9 4 2 6 Reset button 2 5 2 6 3 Leakage Circuit Breaker Power Cord 3 1 Main control unit 3 2 Turn on button
5. el to start The remote control of HW CPP 01 begins to count down timer of 100 seconds for a presetting water outflow period in this operating mode the stable warm water will be flowing out during this time Please refer to PIC5 4 At this moment the orange indicating light is lighting constantly and the green indicating light flashes on the panel PIC 5 4 The stable warm water between 37 390 will be flowing out in the operating mode When the 100 seconds count down time is up the anal tube nozzle will stop supplying water and there will only be the orange indicating light in lighting on the panel The machine now is staying in standby mode If HW CPP O1 machine is required to be used continuously please repeat the aforesaid procedure 3 6 During treatment if you feel the water is not feeding enough to the bowel In case the machine has to be stopped temporarily you may directly press the ON OFF button of remote control or outflow button of panel to stop the operation the machine will return to stand by mode 7 If you want pack up the device after use you can press the Drain button on the panel around 4 seconds the water pump will start running and the device will be draining the remaining water of the water tank off continuously until empty the orange indicating light of power will go glowing constantly and the green indicating light of in operation will appear flashing on the panel Once the water
6. f circuit breaker leakage power cord in standby meanwhile you will see the orange light on at the head of power cord as PIC 4 8 P5 5 How to use 1 Press the green button at the head of circuit breaker leakage power cord the orange indicator light will go out and the machine will be activated and proceeding with system self test automatically the auto water outflow will stop after 10 seconds running the orange indicator light on the side of main body panel will be brightening constantly and the next green indicator light will be flashing PIC 5 1 Press center green button to power on the device meanwhile orange light will go out 2 The machine will go into Auto heating mode about minute During this period please don t press outflow button on the panel of main body or the ON OFF button of remote control and now the panel only shows the orange indicator light on During this period the user can smear some lubricating oil or surgilube on and around anus also lubricate the nozzle of anal tube for helping inserting the anal tube into anus smoothly button of remote control during auto heating mode at the 1 minute P6 3 After 1 minute auto heating use your hand to hold the anal tube to assist insertion of anal tube into 4 P7 5 your anus and then sit on toilet ready for irrigation treatment in User now could press the ON OFF button of remote control or outflow button on the pan
7. he machine returns to a waiting condition anes proceed with the Procedure 2 flashing4 4 If problem keeps the same inform times Lighting X w o water outflow our customer service department 5 Check that the water in water tank is enough flashin 6 After you drain the water off and Lighting X SUMS W o water outflow pump has stopped running press the continuously i i drain button again to have the machine return to the waiting mode P9 7 Product index 1 1 Personal health care Salon Clinic Hospital Nurse on site sevice Trained hydrotherapist 2 1 Power Adaptor Input 2 2 Power Consumption 2 3 Water Yield 2 4 Outflow Pressure 2 5 Inlet Temperature 2 6 Ambient Temperature Universal AC100 220V 400W 1200W it s subject to the local 400 200c c min Below 1 2Kg cm 2 2psi gt 380 50 3 1 Housing Material 3 2 Housing Colour 3 3 Dimension LxWxH 3 4 Net Weight Gross Weight Plastic Storage Tank Cover Transparent Light blue Main Body Brilliant White 250mm x 160mm x 250mm 3 5g 0 2 Kg AC Power Cable User Manual 4 3 Remote Controller 4 4 Silicone tube 4 5 Stool Steadier 4 6 Anal Tube L type tube 1 pcs 1 pcs 1 set 1 pcs 1 set 15 pcs each P10