Home
Model 484A SerialPRO II Interface User's Guide
Contents
1. 7 apc casi brawe Model 484A SerialPRO II Interface User s Guide Functional Description The 484A SerialPRO II Interface provides a dedicated easy to use and economical RS232 serial connection to APG cash drawers This interface will plug directly into the RS232 serial port of the host device computer terminal etc It has diagnostic lights to assist in installation and troubleshooting The unique design of this dedicated interface allows you to select 4 different levels of security for the drawer opening sequence significantly reducing the chance of unauthorized openings that result from noise associated with power up and power down of the system The DIP switches for selecting the opening sequence are conveniently located on the bottom of the cash drawer unit near the cable exit These DIP switches also allow for the selection of drawer status reporting location as well as other setup and diagnostic functions This interface is designed for standard RS232 implementations where DTR and RTS are held high while the port is open In most situations it is powered by the serial port eliminating the need for an external power supply An external power supply can be used in situations where DTR and RTS are not consistently held high as is the case with Windows NT The interface includes a cable for connection to the serial port As a standard product this cable is equipped with a 9 pin female DB9F connector and a 25 pin female DB25F to
2. 9 pin male DB9M adapter cable I Configuration and Use This Guide assumes the user has some technical experience connecting computer peripherals 1 Verify DIP switch settings are applicable to the system The DIP switches see Figure 1 below on the electrical interface board are accessible from the bottom of the cash drawer unit Connect the cash drawer to the appropriate dedicated RS 232 serial COM port on the host device Open COM port and wait twelve seconds to charge drawer first time only before transmitting the opening sequence Open the cash drawer through the software or refer to step 5 below Transmit a BEL character from the host to open cash drawer See Section II and Section III for examples If cash drawer openings occur on power up down a higher level of noise immunity should be used This can be done by setting DIP switch 9 and switch 10 off switch 8 on and send any sequence of characters such as UU that produce a minimum of 8 pulse edges Refer to Chart 1 for more details DN Wily Switch Settings Description 1 Diagnostic Tool off Power Test disabled ON Power Test enabled Do not use until instructed 2 Extended Security ON RTS Disable set off RTS Disable released Do not use until instructed 3 4 Signal Source ON off PC operation enabled DB9 contact 3 DB25 contact 2 off ON Terminal operation enabled DB9 contact 2 DB25 contact3 5 CTS RTS Handshaking ON hands
3. opened every 2 3 i seconds See Figure 2 at right for assembly details x z 5 S db There are situations such as Windows NT operating systems where the power supply is required for proper operation j d Power Supply IV Troubleshooting FIGURE 2 Cable This section is intended to assist in configuring the SerialPRO II Interface to work with your specific system The cash drawer is equipped with two diagnostic lights or LED s Light Emitting Diodes inside the drawer to aid in trouble shooting a system These lights can be seen by opening the drawer with the key removing the plastic money tray and looking into the back of the cash drawer The green LED will be off unless the optional power supply is plugged in or DIP switch 1 is ON The yellow LED flashes while any data or character s 1s being received NOTE The 484A SerialPRO II interface allows changing of the DIP switch settings with the power and port active To observe LED s with cash drawer closed place drawer on it s side and partially extract the interface board and bracket assembly from the cash drawer by removing the mounting screws See Figure 2 A To Verify Power Is Being Supplied If the serial port is used to provide power turn DIP switch 1 ON A solid green light indicates power is provided If the green LED does not turn on 1 Check to make sure that the cash drawer is connected to the correct port on the host 2 Confirm that the port on the host is work
4. 12 C 2 44 2C 3 L 76 4C 3 l 108 6c 3 CR lt Ctri gt lt M gt 13 D 3 45 2D 4 M 7 4D 4 m 109 6D 4 SO lt Ctrl gt lt N gt 14 E 2 46 2E 3 N 78 4E 3 n Ho 6E 3 SI lt Ctrl gt lt 0 gt 15 F 2 41 2F 3 O 79 4F 3 o IH 6F 3 DLE lt Ctri gt lt P gt 16 10 2 0 48 30 2 P 80 50 3 p 112 70 2 DCI lt Ctri gt lt Q gt 17 11 3 1 49 31 3 Q 81 51 4 q 113 71 3 DG Ctrl R 18 12 3 2 50 32 3 R 82 52 4 r 114 72 3 DC3 lt Ctri gt lt S gt 19 13 3 3 51 33 3 S 83 53 4 s 115 73 3 DC4 Ctrl T 20 14 3 4 52 34 3 T 84 54 4 t 116 74 3 NAK lt Ctrl gt lt U gt 21 15 4 5 53 35 4 U 85 55 5 u 117 75 4 SYN lt Ctrl gt lt v gt 22 16 3 6 54 36 3 V 86 56 4 v 118 76 3 ETB lt Ctrl gt lt w gt 23 17 3 7 55 37 3 W 87 57 4 w 119 77 3 CAN lt Ctrl gt lt x gt 24 18 2 8 56 38 2 x 88 58 3 x 120 78 2 EM lt Ctrl gt lt Y gt 25 19 3 9 57 39 3 Y 89 59 4 y 121 79 3 SUB lt Ctrl gt lt Z gt 26 1A 3 58 3A 3 Z 90 5A 4 z 122 7A 3 ESC lt Ctrl gt lt gt 27 1B 3 59 3B 3 931 5B 4 123 7B 3 FS lt Ctrl gt lt gt 28 1c 2 lt 60 3C 2 92 sC 3 124 7c 2 GS Cul 29 ID 3 6 amp l 3D 3 93 5D 4 125 7D 3 RS Cub 30 IE 2 gt 62 3E 2 94 SE 3 16 7E 2 US lt Ctrl gt lt gt 31 1F 2 63 3F 2 95 5F 3 DEL 127 7F 2 NOTE If serial port is set for 7 bit characters subtrac
5. com Windows is a trademark of Microsoft Corporation The APG logo APG Cash Drawer and SerialPRO are registered trademarks of APG Cash Drawer Copyright 2002 by APG Cash Drawer Minneapolis Minnesota U S A PN M 23G 484A Rev CHART 1 PULSE EDGES PER ASCII CHARACTER NON PRINTABLE ASCII CHARACTERS PRINTABLE ASCII CHARACTERS Number Number Number Number ASCII Control Dec Hex Jof Pulse ASCII Dec Hex of Pulse ASCII Dec Hex of Pulse ASCII Dec Hex of Pulse Character Character Num Num Edges Character Num Num Edges Character Num Num Edges Character Num Num Edges NUL lt Ctr gt lt gt 0 0 1 space 32 20 2 64 40 2 60 2 SOH lt Ctrl gt lt A gt 1 1 2 33 21 3 A 65 41l 3 a 97 61 3 STX lt Ctrl gt lt B gt 2 2 2 34 22 3 B 66 42 3 b 98 62 3 ETX Cub c2 3 3 2 35 23 3 C 67 43 3 c 99 63 3 EOT lt Ctrl gt lt D gt 4 4 2 36 24 3 D 68 44 3 d 100 64 3 ENQ Cub cE5 5 5 3 137 25 4 E 69 45 4 e 101 65 4 ACK lt Ctr gt lt F gt 6 6 2 amp 38 26 3 F 70 46 3 f 102 66 3 BEL lt Ctrl gt lt G gt 7 7 2 l 39 27 3 G 71 47 3 g 103 67 3 BS lt Ctrl gt lt H gt 8 8 2 40 28 3 H 72 48 3 h 104 68 3 HT lt Ctrl gt lt I gt 9 9 3 41 29 4 I 73 49 4 i 105 69 4 LF Ctr 10 A 3 42 2A 4 J 7A 4A 4 j 106 6A 4 VT lt Ctr gt lt K gt 11 B 3 43 2B 4 K 75 4B 4 k 107 6B 4 FF lt Ctrl gt lt L gt
6. haking enabled If ON do not enable CTS drawer status FIGURE 1 off handshaking disabled RTS at DB9 contact 7 DB25 contact 4 5 6 7 Drawer Status off off drawer status disabled off ON off CTS drawer status DB9 contact 8 DB25 contact 5 off ON RI drawer status DB9 contact 9 DB25 contact 22 8 9 10 Minimum Opening Pulse Edges off ON off Pulse window set to 2 edges off off ON Pulse window set to 1 edge ON off off Pulse window set to 8 edges The APG default settings are shown as bold text above II Cash Drawer Testing The following examples will illustrate how to open the drawer with the original factory switch settings If the operating system is Windows environment use the DOS window for the command entry COMI is used throughout this example Replace COMI with COM2 etc if appropriate Type the bold letters into the computer NOTE The interface operates from 600 to 19 2K baud 9600 baud is shown only as an example The interface 1s not affected by changes in parity bit length and stop bits These parameters can be any setting required by the user A Opening the Cash Drawer using DOS 1 Verify the switches on the cash drawer are set to the original factory settings Refer to Figure 1 in Section I for these settings 2 Setthe Mode command which will define the communication parameters of the serial port C gt MODE COM1 9600 N 8 1 Enter key 3 Wait twelve 12 seconds before attempting to open the cash dra
7. he correct DIP switch see table next to Figure 1 is set ON and close the drawer to allow the host to transmit the opening data sequence out the serial port 5 Recheck all the DIP switch settings if appropriate reset to default See Figure 1 Toggle each switch from its current position to the opposite position and back to be sure each switch is fully seated in the proper position For example if it is ON turn it off and then ON again If the yellow LED flashed and the drawer did not open 1 Ifother devices are on the same port disconnect them The Model 484A SerialPRO II Cash Drawer is not designed to operate with additional devices on the serial port 2 Make sure that the DIP switch settings 8 9 10 are set less than or equal to the ASCII character s pulse count transmitted by the host See Chart 1 3 Iftwo or more characters are used to open the cash drawer check to make sure that the software 1s sending the characters sequentially 4 Configure the drawer to open on one pulse Switch 8 off 9 off 10 ON to determine if the drawer recognizes any of the opening commands from the host 5 Ifthe host device does not provide a high RTS line change DIP switch 2 to off and retest the opening code Leaving switch 2 off will reduce the noise immunity of the interface If difficulties persist contact your supplier for more information or contact APG Cash Drawer technical support at 763 571 5000 or via email at support apgced
8. ing properly Connect another device that has worked previously on this port or if applicable use Section II or Section III to verify proper operation of port CAUTION Turn DIP switch 1 off after this test Do not operate the cash drawer with the switch on it may cause poor performance of the interface If the power supply is providing power and the green LED is not on 3 Check to make sure that the AC power supply is plugged into a 115 VAC 60 Hz outlet and verify that the outlet is functional 4 Check that the power supply cable is connected properly into the board connector on the circuit board inside the cash drawer See Figure 2 B To Verify Signal Is Being Received A flashing yellow light indicates the interface is receiving data from the serial port If the yellow LED did not flash 1 Verify steps 1 and 2 above 2 Check to make sure that the DIP switches 3 and 4 are set correctly for PC or Terminal operation Both cannot be ON or off at the same time 3 Some software applications require hardware handshaking between the host and peripheral devices This may include jumpering the CTS and RTS lines Check to make sure that DIP switch 5 is ON and switch 6 is off if this option is required Switch 6 enables CTS drawer status and cannot be used with CTS RTS handshaking enabled Hardware handshaking of DSR DCD and DTR is incorporated into the attached interface cable 4 Ifthe software package checks for the drawer status verify t
9. t 1 pulse from ASCII characters hex 40 to DEL hex 7F M 23G 484A Rev Copyright 2002 APG Cash Drawer
10. wer the first time The following command will transmit the BEL character Ctrl and G keys held at the same time to open the cash drawer C gt ECHO G 2COMI Enter key B Opening the Cash Drawer using BASIC To open drawer in Basic OPEN COM1 9600 N 8 1 CS DS CD FOR RANDOM AS 1 REM MUST REMAIN OPEN IF DRAWER IS POWERED BY DTR RTS START TIMER WHILE TIMER lt START 12 WEND REM 12 SEC FOR 1ST OPENING CHARGING 6 SEC FOR SUBSEQUENT RECHARGING PRINT 71 CHR 7 REM BEL CHARACTER FOR 2 EDGE PULSE There are two options for reading drawer status in Basic START TIMER WHILE TIMER lt START 2 WEND REM 200 mSEC ALLOWS DRAWER TO OPEN BEFORE CHECKING STATUS CODE INP amp H3FE REM ASSUMING COMI USED 1 Reading CTS drawer status in Basic SW5 ON SW6 off IF CODE AND 16 16 THEN PRINT CTS OPTION DRAWER CLOSED IF CODE AND 16 0 THEN PRINT CTS OPTION DRAWER IS OPEN 2 Reading RI drawer status in Basic SWS off SW6 ON IF CODE AND 64 64 THEN PRINT RI OPTION DRAWER CLOSED IF CODE AND 64 0 THEN PRINT RI OPTION DRAWER IS OPEN III Power Supply Installation Optional a Board Connector This interface will allow openings as frequently as every 6 seconds For Power Supply with serial port COM power Ifa faster cash drawer opening LED s cycle is required the external power supply may be installed Using 2s A a External Cable the power supply the drawer can be repeatedly
Download Pdf Manuals
Related Search
Related Contents
Manuale - Hanna Instruments MailGate User Manual Questões de anos anteriores pflex-um002 - Literature Library Sac Harnais Tandem G24 SERIES GAS-OPERATED COUNTER GRIDDLE Bedienungsanleitung IMPRESSA A One Touch - best-in (Microsoft PowerPoint - MEDEF 35 marchés publics PME) HD CR 43 NDT/CR 43 NDT Copyright © All rights reserved.