1. Datavideo Technologies Europe BV Tel 31 30 261 96 56 Fax 31 30 261 96 57 E Mail service datavideo nl Datavideo UK Limited Tel 44 1457 851 000 Fax 44 1457 850 964 E Mail sales datavideo co uk Datavideo Technologies Co Ltd Tel 886 2 8227 2888 Fax 886 2 8227 2777 E mail service datavideo com tw Datavideo Technologies China Co Ltd Tel 86 21 5603 6599 Fax 86 21 5603 6770 E mail service datavideo cn Datavideo Technologies S PTE LTD Tel 65 6749 6866 Fax 65 6749 3266 E mail sales datavideo sg Datavideo HK Limited Tel 852 2833 1981 Fax 852 2833 9916 E mail info datavideo com hk Datavideo France Tel 33 1 60 37 02 46 Fax 33 1 60 37 67 32 E Mail info datavideo fr Datavideo India Tel 91 0120 2427337 Fax 91 0120 2427338 E Mail sales datavideo in All the trademarks are the properties of their respective owners Datavideo Technologies Co Ltd All rights reserved 2018
2. Datavideo office or authorized Distributors Certain parts with limited lifetime expectancy such as LCD Panels DVD Drives Hard Drives are only covered for the first 10 000 hours or 1 year whichever comes first Any second year warranty claims must be made to your local Datavideo office or one of its authorized Distributors before the extended warranty expires Disposal For EU Customers only WEEE Marking This symbol on the product indicates that it will not be treated as household waste It must be handed over to the applicable take back scheme for the recycling of electrical and electronic equipment For more detailed information about the recycling of this product please contact your local Datavideo office Packing List 1 x PD 6 1 x Quick Start Guide 1 x Accessory List Product Overview Lights Cameras PD 6 The Datavideo PD 6 is a 19 rack mountable universal AC to DC power distribution center Designed to be used in conjunction with Datavideo Mobile Video Studios like the MS 900 and the CB 22 CB 23 CB 38 all in one cable The PD 6 supplies a steady user chosen voltage for your non Datavideo production kit whilst on location or in your studio Features Automatically adjusts to work with 50Hz or 60Hz supplies between 100 240 VAC 8 DC outputs with a combined total power consumption of 360 Watts Each DC output can be switched to provide either 12 14 4 24 or 48 Volts Each DC output has a multi colou
3. sur la protection contre les surintensit s et les c bles d alimentation Un examen appropri des notes des quipements et de la plaque signal tique doit tre fait pour traiter cette pr occupation E Mise la terre fiable La mise la terre fiable du mat riel mont en rack doit tre maintenue Une attention particuli re doit tre apport e aux connexions d alimentation autres que les connexions directes au circuit par exemple l utilisation de multiprises Warranty Standard Warranty Datavideo equipment is guaranteed against any manufacturing defects for one year from the date of purchase The original purchase invoice or other documentary evidence should be supplied at the time of any request for repair under warranty Damage caused by accident misuse unauthorized repairs sand grit or water is not covered by this warranty All mail or transportation costs including insurance are at the expense of the owner All other claims of any nature are not covered Cables amp batteries are not covered under warranty Warranty only valid within the country or region of purchase Your statutory rights are not affected Two Year Warranty All Datavideo products purchased after 01 Oct 2008 qualify for a free one year extension to the standard Warranty providing the product is registered with Datavideo within 30 days of purchase For information on how to register please visit www datavideo tek com or contact your local
4. 24V 48V DC output ing Tem C O Overlo Powers the PD 6 On Off Light switch indicator e i rking Te Working Temp 0 C to 40 C 32 F to 102 F Environment Working Humidity 10 to 90 non condensing Ser AU OS CMOS ee Has four built in cooling fans please ensure that these are not blocked and that some airflow is available Cooling Fan N B Internal ambient temperature of about 50 C fan starts 2 fans at middle and 1 fan at rightmost N B Internal ambient temperature of about 70 C fan starts 1 fan closes to the Ground terminal DC Output LED LED Color Indicator Indicator Red 48V light Red 24V Green 14 4V Blue 12V Dimension 440 mm x 235 mm x 46 mm Lx W x H Weight Approx 5 2 kg 11 5 lbs When connecting this unit to any other component make sure that it is properly Ground Terminal grounded by connecting this terminal to an appropriate point When connecting use the socket and be sure to use wire with a cross sectional area of at least 1 0 mm2 Service amp Support It is our goal to make your products ownership a satisfying experience Our supporting staff is available to assist you in setting up and operating your system Please refer to our web site www datavideo com for answers to common questions support requests or contact your local office below Datavideo Global Website www datavideo com Datavideo Corporation Tel 1 562 696 2324 Fax 1 562 698 6930 E Mail techsupport datavideo us
5. dataviceo PD 6 Quick Start Guide www datavideo com Dec 18 2013 P N G082060604B3 Contents cla le dc O Safety Instructions Rack Mount asocio caian aii Warranty sea ad hian e ia a A a a a a cheba Nr Ne en A aa a aa ae a aea aa e ea a o ee aan A Pr cn Product OVS IMG Wiegand lcd cece nee ica ois 1d doko AS Front Panel zes esse A ee SEIVICE amp SUPPORT ee es oa Warnings and Precautions i Read all of these warnings and save them for later reference Follow all warnings and instructions marked on this unit Unplug this unit from the wall outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning Do not use this unit in or near water Do not place this unit on an unstable cart stand or table The unit may fall causing serious damage Slots and openings on the cabinet top back and bottom are provided for ventilation To ensure safe and reliable operation of this unit and to protect it from overheating do not block or cover these openings Do not place this unit on a bed sofa rug or similar surface as the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiator This unit should not be placed in a built in installation unless proper ventilation is provided This product should only be operated from the type of power source indicated on the marking label of the AC adapter If you are not sure
6. itions Adjust only those controls that are covered by the operating instructions in this manual improper adjustment of other controls may result in damage to the unit and may often require extensive work by a qualified technician to restore the unit to normal operation e When the product has been dropped or the cabinet has been damaged f When the product exhibits a distinct change in performance indicating a need for service Safety Instructions Rack Mount Marking or Instruction Details Rack Mount Instructions The following or similar rack mount instructions are included with the installation instructions A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits migh
7. of the type of power available consult your Datavideo dealer or your local power company Do not allow anything to rest on the power cord Do not locate this unit where the power cord will be walked on rolled over or otherwise stressed If an extension cord must be used with this unit make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord s rating Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes Never push objects of any kind into this unit through the cabinet ventilation slots as they may touch dangerous voltage points or short out parts that could result in risk of fire or electric shock Never spill liquid of any kind onto or into this unit Except as specifically explained elsewhere in this manual do not attempt to service this product yourself Opening or removing covers that are marked Do Not Remove may expose you to dangerous voltage points or other risks and will void your warranty Refer all service issues to qualified service personnel Unplug this product from the wall outlet and refer to qualified service personnel under the following conditions a When the power cord is damaged or frayed b When liquid has spilled into the unit c When the product has been exposed to rain or water d When the product does not operate normally under normal operating cond
8. r LED confirming the chosen voltage by colour e The unit is designed to provide both DC amp AC overload protection A standard 19 1U rack mountable case Front Panel Power Switch DC Outputs x 8 On Off Switch Powers the PD 6 On Off when using AC Power AC In with built in fuse AC Inlet for connecting to suitable mains power outlet 100 240VAC The socket contains a fuse holder fitted with a 6 3A 250V fuse DC Output ll 8 DC outputs with a combined total power consumption of 360 Watts Each DC output can be switched to provide either 12 14 4 24 or 48 Volts Specification Voltage Range 100 240 VAC AC frequency 50Hz or 60Hz AC Input Fuse Rating 6 3A 250VAC Efficiency Typ UP TO 80 DC Voltage 12V gt 14 4V 24V 48V Rated Power Max 4 channels for 30W 4 channels for 60W AC In outlet AC Inlet for connecting to suitable mains power outlet 100 240VAC The socket with built in fuse contains a fuse holder fitted with a 6 3A 250V fuse 105 150 rated output power a DC Overload Protection Protection type Recovery automatically after fault condition is removed n 8 Groups DC OUTPUT 4PIN XLR Female 5in4 GND PIN2 VCC PIN3 4 NC id O non recovery fuse on the AC input outlet ff Switc Connector 8 Groups Switch S Switch There are four options for each group 12V 14 4V
9. t have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern E Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Instructions de montage en Rack Les instructions de montage en rack suivantes ou similaires sont incluses dans les instructions d installation A Temp rature ambiante de fonctionnement S il est install dans un rack ferm ou unit s multiples la temp rature ambiante de fonctionnement du rack peut tre sup rieure a la temp rature ambiante de la pi ce Par cons quent il faut envisager d installer l quipement dans un environnement compatible avec la temp rature ambiante maximale Tam sp cifi e par le fabricant B D bit d air r duit L installation de l quipement dans un rack doit tre telle que la quantit de flux d air n cessaire au bon fonctionnement de l quipement ne soit pas compromise C Charge m canique Le montage de l quipement dans le rack doit tre tel qu une situation dangereuse ne soit pas li e une charge m canique irr guli re D Surcharge du circuit d alimentation II faut tenir compte de la connexion de l quipement au circuit d alimentation et l effet que la surcharge des circuits pourrait avoir