Home
SCREEN CREATOR 5 TROUBLESHOOTING AND ERROR CODES
Contents
1. aread error occurs in a clock indicator 5554 In the K Basic SETALARM statement an invalid time hour minute is specified no more alarm settings can be made up to 16 a Write error occurs in a clock indicator 5555 The K Basic RESETALARM statement causes a write error in a clock indicator 5556 The K Basic OPENTIM statement causes excess timers to be gotten up to 16 5557 In the K Basic SETTIM statement e an invalid timer number is specified atimer in use is specified 5558 In the K Basic STARTTIM statement an invalid timer number is specified atimer in use is specified 5559 The K Basic STOPTIM statement causes an invalid specification of a Eu MK 5560 In the K Basic CONTTIM statement e an invalid timer number is specified atimer in use is specified The K Basic READTIM statement causes an invalid specification of a timer number 5563 The K Basic SETBEEP statement causes an invalid specification of ON OFF time or beeping count 5564 The K Basic BEEP statement causes an invalid specification of ON OFF value 5566 The K Basic COPY statement causes an invalid specification of printing color 5567 The K Basic BLCTL statement causes an invalid specification of ON OFF value 5569 The K Basic CHKTIM statement causes an invalid specification of a timer number 5571 The K Basic CHKTIM statement causes an invalid specification of a timer number 5572 In the K Basic SETTIM statement e an invalid ti
2. Action Open the object from the Open command in the library menu make the background small and reduce the area with the change property function for rearranging the object E216 Part of group components is not selected Cause Part of group components is not selected Action When you work with a component select all parent and child components E217 The selected component is being edited Cause Component in editing cannot be cut or deleted Action When you want to cut or delete a component deselect it or close the sub window in editing Then cut or delete it E218 Grouping cannot be made since the number of components exceeds the component arrangement limit Cause Grouping components increment arranged components As a result the number of arranged components exceeds the limit Action Ifthe grouping is mandatory delete another arranged component E219 No component is selected Cause Editing is performed before component selection Action Select a component before editing E220 Grouping cannot be made Selected components include a grouped one Cause already grouped component is about to be grouped Action Deselect a grouped component in selected ones E221 Grouping components failed Cause Grouping components failed Action Terminate Screen Creator and restart Windows If the error still occurs after restarting Windows then reinstall Wind
3. cceccceeseeeesceeeeeeteeeeeeeeseaeeseaeeeeaeeseaeeseaeeeeeeseaeeseeseieeeeeesaas 3 8 3 7 Errors Caused with Too Many Messages lIssued ssssssssseeeneeeeeneee nennen nennen nnne 3 22 3 8 OIP BIt0OIS A miti enean 3 23 3 9 Errors in Peripheral Devices irz erdt eti den cineri fent trt itd nei Ae 3 27 How This Manual Is Organized How This Manual Is Organized This manual Chapter 1 through 4 includes structures of data to be displayed on the OIP and operations in detail for you to use the OIP Chapter 1 Fundamentals in Creating Screens Outlines general ideas and organizations of data to be displayed on the OIP You should read through this chapter before referencing the other chapters Chapter2 Installation for Screen Creator 5 Covers the environment in operation and installation of Screen Creator 5 Chapter 3 Basic Operations for Screen Creator 5 Describes each function name of Screen Creator 5 and operations for the keyboard and mouse Chapter 4 Menu Reference Thoroughly discusses each menu of Screen Creator 5 You are recommended to reference the following manuals for using Screen Creator 5 Vol 1 Screen Creator 5 Manual Introduction Introduces fundamental operations of Screen Creator 5 Vol 2 Screen Creator 5 Manual Operations Describes operations of Screen Creator 5 in details Vol 3 Screen Creator 5 Manual PLC External Equipment Connection Covers the communications procedures with a host computer
4. Contents BH Contents CHAPTER 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 1 Errors and Warnings in Operating Screen 1 2 1 2 Errors during Screen Creator Operation nennen enne nnne nenne nnne 1 3 1 3 Warnings during Screen Creator Operation sssssssseseeeneeeeenneeeneren nennen nnns 1 14 CHAPTER 2 ERRORS WARNINGS IN CREATING DATA 2 1 Errors Warnings in Creating Data sse nennen neret neret nennt nnne nennen 2 2 2 2 J Errors in Gompllationiz 23 n pantalla E e p d ce E eus 2 3 2 3 Errors in Creating Downloading Data esssssseseeeeen eene nnnren nnne nns 2 12 2 4 Warnings in Creating Downloading Data ssssssssseeeeeeeeenneennenen nennen nennen nennen nennen 2 16 CHAPTER 3 ERRORS AT OIP OPERATION 9 1 Errori Display at OIP OperatioDi oio recte dut te te ter A iet eire cord ge rac cc atid 3 2 3 2 Errors at Main CPU Detecting Troubl tnnt nennen 3 4 3 3 Errors during Serial Communication eeessessessseeseseeeeeeeeeee nennen nnne nnns 3 5 3 4 Errors during Downloading Uploading 3 6 3 9 Errors during Message PrOCeSS coe teh e ai amice eed e bu eee oer Reb ee te ie Reds 3 7 3 6 Errors during Operation Program Execution
5. is used by a global function The declared function is the same as that used in the screen program in a global screen Change the function name Subroutine is used by a global subroutine The declared subroutine is the same as that used in the screen program in a global screen Change the subroutine name The system memory exceeds 512 KB A system RAM insufficient error may occur Used amount of the system memory approaches the limit of he OIP memory Perform downloading and display all screens If the system RAM insufficient error does not occur you do not care for the warning If the error occurs change the screen data or operation program to reduce memory use amount The backup variable is handled as a global variable in this panel No backup battery exists in an OIP Jr system Thus a specified backup variable is interpreted as a global variable Since the backup variable is handled as a global variable the backup function is ignored The other functions are not affected 2 16 2 ERRORS WARNINGS IN CREATING DATA 3 ERRORS OIP OPERATION 3 1 3 1 Error Display at OIP Operation 3 1 Error Display at OIP Operation This chapter describes errors to occur during OIP operations If an error occurs during OIP operation its message appears in the OIP screen You can select one of two locations for displaying the error message one is on the error indicator placed in a global scre
6. SWFIG 7664 A switch is specified which has not been recorded in the logical switch table function stop 7665 A switch is specified which has not been recorded in the logical switch table function restore 7666 A switch is specified which has not been recorded in the logical switch table mask change A switch is specified which has not been recorded in the logical switch table switch display incendi You cannot a floppy 3 25 3 8 OIP Errors Check the memory car m ui c I 00 191 010 Dc n MR 7832 A function without a driver is called in the memory card driver serial Check the operation type program and memory card 7833 An access is made beyond the medium size in the memory card driver Size serial type 7834 The current directory is not set in the memory card driver serial type 7840 An initialization error in the memory card driver bus type Check the memory card 7841 An initialization error in the memory card driver bus type 7842 A function without a driver is called in the memory card driver bus Check the operation type program and memory card 7843 An access is made beyond the medium size in the memory card driver size bus type 7844 The current directory is not set in the memory card driver bus type 7901 An OS error Inform the technical to support of this company of 7926 the error code 3 26 ERRORS AT OIP OPERATION 3 9 Errors in Periph
7. Specify a correct device name EC041 The PLC device cannot be used in a library function Cause The PLC device cannot be used in a library function Action Do not use the device EC042 No memory table can be used since no host is specified in the connection device Cause memory table can be used since no host is specified in the connection device Action Add the host in the connection device EC043 The memory table number exceeds 2048 in the CYCLIC declaration Cause The memory table number exceeds 2048 in the CYCLIC declaration lt Action gt Memory tables you can use are 0 through 2047 EC044 The memory table number must be a numeric constant in the memory table CYCLIC declaration Cause The memory table number must be a numeric constant in the memory table CYCLIC declaration lt Action gt Specify the memory table number with an integer EC045 The memory table number must be an integer lt Cause gt The memory table number must be an integer lt Action gt Specify the memory table number with an integer EC046 The memory table continuous declaration must be made with an integer Cause The memory table continuous declaration must be made with an integer Action Specify the continuous declaration with an integer EC047 The memory table number must be a constant in memory table ID comparison Cause The memory table number must be a constant in memory table ID com
8. E200 Invalid input value Name invalid WOO02 Select class want to be saved please Error message example Warning message example As shown in the above example a number follows a letter E and they are called an error number Likewise a warning number begins with a letter W which is followed by a message stating why the warning is displayed The following part of this chapter describes error and warning messages which may appear during operation of Screen Creator We also discuss their possible causes and countermeasure of the errors and warnings 1 2 CHAPTER 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 2 Errors during Screen Creator Operation 1 2 Errors during Screen Creator Operation E000 Memory space is insufficient Cause Memory space is not enough to operate Screen Creator or an error exists in Windows lt Action gt Terminate Screen Creator and restart Windows If no error occurs after restarting Windows then start Screen Creator E001 An error exists in the operating system Windows Cause error might exists in Windows or the Screen Creator file EXE or DLL Action Terminate Screen Creator and restart Windows If no error occurs after restarting Windows then start Screen Creator If Windows is healthy re install Screen Creator E002 file cannot be open Cause The file for editing cannot be open since it is destroyed Action For investigating the
9. Screen Creator 5 1 6 CHAPTER 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 2 Errors during Screen Creator Operation E110 Contents in the user function library are invalid Cause The user function library file USER FNC in the Lib folder is invalid Action Copy the user function file to another folder for investigation and delete it for recreation of functions E111 Contents in the color adjusting file for a bit map and screen are invalid Cause The color adjusting file for a bit map and screen is destroyed Action Delete the color adjusting file once and execute the Bit map color adjusting function again E200 The entered value is invalid lt Cause gt The entered value is invalid lt Action gt Reenter an appropriate value E201 The standard function cannot be saved lt Cause gt You cannot save the standard function afresh Action Re name it as a user function for saving E202 The character strings cannot be saved max count exceeded Cause You cannot save the character strings since the number of character strings exceeds the limit for saving Action Reduce the number of character strings for saving E203 An error exists in component data of a component file Cause Contents of a component are invalid Action Delete the selected component If the component has already been arranged delete it from the screen E204 Saving the component data failed
10. Screen Creator Successful start You may use it as it is but part of the library is possibly destroyed Error occurrence Delete the renamed PLB file and initialize the library Initialization You cannot recover the library Re install Screen Creator 5 When restarting Screen Creator 5 the library in the initial state is usable Since added libraries are all lost it is necessary for repairing operation Repair There are two ways for repairing a library 1 You repair the library on Screen Creator This method is safe in file integrity but it takes long time for repairing Select Add a file from outside in the library menu and select a file for adding it to the library in succession In almost all cases a file exists in the LIB folder and a file name is equal to a library name Thus the operation is not difficult and you can repeat the file selection and addition 2 You can access a file directly This method is not safe in file integrity but it does not take long time for repairing Open the PLB using Memo Pad Then add library entries in accordance with the PLB file format If you enter a wrong class number file name etc an error occurs again In this case you must the operation from scratch Contents in the standard function library are invalid The standard function library file GENERAL FNC in the Lib folder is invalid Copy the standard function file to another folder for investigation and reinstall
11. able to isolate the cause of the error contact the technical support of this company The code for data operation is invalid An error exists in control data operation description Correct the control data operation description Since an invalid drawing element is found the creating operation is canceled 1 compiler cannot recognize the drawn element 2 Screen or component data may be destroyed Delete the element and arrange a drawing element again If not being able to isolate the cause of the error contact the technical support of this company Save Screen again This error may cause when a pattern is drawn in a global screen or a fixed component is arranged Save the global screen once more and create data Global Screen does not exist The global screen does not exist Create the global screen specified with Properties of Project Screen does not exist Recorded screen data does not exist Correct data of the recorded screen or create a screen Screen cannot be open An error occurs in your computer 2 Screen data may be destroyed 1 Start Screen Creator again 2 Check that the computer file system is healthy 2 12 2 ERRORS WARNINGS IN CREATING DATA 2 3 Errors in Creating Downloading Data EL008 Loading Screen failed Cause 1 error occurs in your computer 2 Screen data may be destroyed Action 1 Start Screen Creator a
12. and connections to peripheral devices Vol 4 Screen Creator 5 Manual Standard Component Catalog You can get to know the standard components and their functions the Koyo Ltd offers Vol 5 Screen Creator 5 Manual Control Reference Describes what are controls and how to use controls for creating components Vol 6 Screen Creator 5 Manual K Basic Programming Offers information on how to write action programs for creating screens and how to use functions Vol 7 Screen Creator 5 Manual Trouble Shooting and Error Codes Covers restrictions on creating screens with Screen Creator 5 how to cope with trouble and error codes Safety Precautions Safety Precautions Be sure to follow the safety precautions listed below in order to use the OIP safely Koyo Ltd cannot be held liable for any damages incurred if these safety precautions are not followed N WARNING Design your system so that there are sufficient countermeasures for personnel accidents and major equipment accidents The system should have an external protection and safety circuit so that even if the OIP should malfunction or even if there is a defect in the program the safety of the system is assured Do not use the touch panel of the OIP to make switches that are related to safety or people or major damages emergency safety switches etc Be sure that the System is designed so that it can cope with any errors or malfunctions in the touch panel Be sure that type 3 gr
13. cannot generate data for the selected PLC Check the version of Screen Creator The number of devices arranged in one screen exceeds 16000 A screen exists which uses the number of PLC devices whose upper limit exceeds 16000 Correct the screen The number of continuous Device specifications exceeds the limit The number of continuous device specifications with the BREAD BWRITE statement exceeds the limit The range depends on PLC types Reduce the number of continuous device specifications The number of devices on the global screen exceeds the limit The number of global screen devices plus the sum of sampling devices exceed 16383 upper limit Reduce the number of devices 2 14 2 ERRORS WARNINGS IN CREATING DATA 2 3 Errors in Creating Downloading Data EL064 The sum of communication devices exceeds the limit Cause The sum of communication read write devices in local global screens exceeds 49151 upper limit Action Reduce the total number of devices EL065 The sum of communication protocols exceeds the limit Cause The sum of communication cyclic event protocols in local global screens exceeds 64 KB Action Reduce the number of using devices or use devices in screens continuously as long as you can ELO070 User defined file does not exist Cause The user defined file created by Screen Creator III does not exist Action Restore origina
14. component W009 The component is outside the area Cause Part of the arranged component is outside the area Action Any component outside the area is not saved Enter it in the area before saving W010 The control is outside the area Cause Part of the created component is outside the area Action control outside the area is not saved Enter it in the area before saving 011 No fixed components can be overlapped Cause Fixed components are overlapped and arranged Action Change the arranging position not to overlap each other W012 No switch controls can be overlapped Cause Switch controls are overlapped and arranged Action Change the arranging position not to overlap each other W013 The selected class cannot be deleted Cause class highest class having lower classes cannot be deleted Action Delete the lower class first Then delete the higher one W014 No library file for use exists Cause list file for the library in use exists Action This file is created with the downloading function When the downloading has finished the file is automatically created W015 No child component can be outside the parent component area Cause Part of the arranged component is outside the area The component stuck out of the area is not saved Action Rearrange the child component in its parent area W016 Device editing cannot be start
15. file 1 5 1 2 Errors during Screen Creator Operation E107 lt Cause gt lt Action gt E108 lt Cause gt lt Action gt Contents in the character string file are invalid Contents in the character string file STR in the project folder are invalid Copy the character string file to another folder for investigation and delete it Then select Character string in the menu to re create it Contents in the library file are invalid The library file PLB in the Lib folder is invalid You cannot continue processing if the library file is destroyed Recover the library file in the following procedure lt Recovery Procedure gt E109 lt Cause gt lt Action gt 1 When the PLB file exists in the Lib folder Use Memo Pad to open the file to verify that the file can be accessed normally Accessible the file to another place and delete the PLB file After the deletion restore it Inaccessible Change the file attribute for accessing the file again When being able to access the file copy the file to another place and delete the PLB file If the file still is inaccessible restart Windows and try the file access again If it can be deleted restore it However if it cannot be deleted initialize it 2 When the PLB file does not exist in the Lib folder perform the restore operation Restore Change a name of the PL_ file in the LIB folder to PLB After the name change start
16. lines around the line where the error is detected 007 An error exists in writing K Basic Cause error exists in writing K Basic Action The description violates the K Basic syntax Check several lines around the line where the error is detected 2 3 2 2 Errors in Compilation ECO008 lt Cause gt lt Action gt ECO009 Cause Action ECO10 lt Cause gt lt Action gt ECOI I Cause Action ECO12 lt Cause gt lt Action gt ECO13 lt Cause gt lt Action gt ECO14 lt Cause gt lt Action gt ECO15 Cause Action ECO16 Cause Action ECO17 lt Cause gt lt Action gt The name is too long The name is too long A variable or function name must be specified within 20 bytes An error exists in screen component name An error exists in screen component name Specify a correct screen component or control name The screen component and control are separated with a period The local variable is not declared The local variable is not declared Before using a local variable be sure to declare with LOCAL The variable has been declared as a global variable The global variable is declared twice in the same program Declaration of a global variable must be only once in a program The variable has already been declared as a backup variable The variable declared as a backup vari
17. memory is used for a memory file reduce the allocated size In addition check the operation program to reduce system or backup memory consumption 5110 In the K Basic RUN statement other than a screen component is Check the screen or specified operation program that 5158 In the K Basic FIELD statement the specified file number is invalid caused the error and 5205 The subscript for an array variable is invalid or an error occurs during PLC device reading writing 5206 The subscript for an array variable is invalid or an error occurs during PLC device reading writing 5216 In the K Basic BWRITE statement the argument variable type is invalid the array variable subscript is invalid a PLC device write error occurs a memory table write error occurs 5217 In the K Basic BREAD statement the argument variable type is invalid the array variable subscript is invalid a PLC device read error occurs a memory table read error occurs 5218 The subscript for an array variable is invalid or an error occurs during ee memory table reading writing 5219 The subscript for an array variable is invalid or an error occurs during memory table reading writing 5220 In the K Basic BWRITE statement the argument variable type is invalid the array variable subscript is invalid a PLC device write error occurs e a memory table write error occurs 5221 In the K Basic BREAD statement nvalid argu
18. record buffer is not declared no declaration at FOPEN 5717 In the K Basic MCPY statement the specified file number is invalid other than a character string type array variable is specified the array variable subscript is invalid the record buffer is not declared no declaration at FOPEN 5750 In the K Basic FOPEN statement the specified file number is invalid the specified mode number is invalid at no record buffer declaration the file number that has been opened already is specified the RAM file is not formatted 5751 In the K Basic FCLOSE statement an invalid file number is specified 3 19 3 6 Errors during Operation Program Execution Countermeasure Action 5752 In the K Basic FPRINT statement Check the screen or the specified file number is invalid operation program that the specified record number is invalid caused the error and the file number not opened is specified correct it the record buffer is not declared no declaration at FOPEN the RAM file overflowed In the K Basic FWRITE statement the specified file number is invalid the specified record number is invalid the file number not opened is specified the record buffer is not declared no declaration at FOPEN the RAM file overflowed 5754 In the K Basic FINPUT statement the specified file number is invalid the specified record number is invalid the file number not opened is specified the reco
19. that may cause operator s death or serious injury in neglecting the WARNING item s Describes a peril that may cause bodily injury or serious device damage in neglecting the CAUTION items s Describes general note s in use Explanations and supplements Glossaries used in this manual are as follows OIP PLC Link unit Device Stands for Operation Interface panel Stands for programmable controller It is also called a sequence controller A link unit is a communication equipment which connects this equipment and the PLC The nomenclature of the communication equipment is different from each manufacture and the equipment is called a link unit in general A device is such equipment that an input output relay internal relay timer counter or resister in the PLC Notice Notice vi We have used our best efforts in preparing this manual We make no warranties with respect to the accuracy or completeness of the contents of this manual and purpose We shall not be liable any loss of profit or any other commercial damages applying this manual directly and indirectly 1 Allrights reserved No part of this book may be reproduced in any form or by any means without permission n in writing from Koyo Ltd 2 Contents of this manual shall be subject to change without notice 3 While every precaution has been taken in the preparation of this manual if the reader notice any errors or has any advice on the contents of t
20. the project cannot be performed since the destination folder is invalid or the disk capacity is insufficient 1 Check that the destination folder is correct 2 Check that the disk capacity is sufficient Fixed components are overlapped Overlapped components exist Change component positions or make them movable Switch controls are overlapped Overlapped switch controls exist Arrange the switch controls which are not overlapped The file cannot be referenced in the library The library has the specified name but the corresponding file is not found This statue may occur when a file is deleted ore re named after saved in the library Delete the file from the library since it cannot be used The primary screen has not been recorded The first screen for recording a project does not exist Screen number 1 is the very first screen at the time of panel activation and must exist The screen number 1 must be created in the project recording function The device list file cannot be loaded Downloading data must have been generated before perform the device editing Execute Create in the project Download function Note that the number of items to be edited is up to 8000 Device editing failed During execution of device editing an error occurs Reference the device edit error 1 12 CHAPTER 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 2 Errors during Screen Creator Operation E249 project is uploade
21. the specified line number or shift direction is invalid 5431 The K Basic FREDSP SLDDSP or MTRDSP statement causes a specification of other than the designated control type 5432 The K Basic PLTDSP statement causes a specification of other than a EZ plot graph 5433 In the K Basic BARDSP BLTDSP or CIRDSP statement other than the designated control type is specified the specified bar zone number is invalid 5434 In the K Basic LNEDSP statement other than a line graph is specified the specified line number or point number is invalid 5435 In the K Basic BARSHIFT statement other than a bar graph is specified the specified shift direction is invalid 5436 In the K Basic LNESHIFT statement other than a line graph is specified the specified line number or shift direction is invalid 5437 In the K Basic BARSET BLTSET or CIRSET statement other than the designated type is specified the specified bar zone number is invalid 5438 In the K Basic LNESET statement other than a line graph is specified the specified line number or point number is invalid 5439 In the K Basic LNESHIFT2 statement other than a line graph is specified the specified line number or shift direction is invalid 5441 In the K Basic STRDSP statement other than a character indicator is specified the character string variable is invalid 5442 In the K Basic PIPECOLOR statement other than a pipe is specif
22. 010 Cause Action E011 Cause Action E012 Cause Action Contents of the file are invalid Contents of the specified file are invalid 1 Check that the file or drive name is correct 2 Check that the file is not opened from another application 3 Check that the objective floppy disk is inserted in the drive 4 Check that the floppy disk medium is not write protected The folder cannot be created The folder cannot be written since 1 the folder name contains an invalid character that Windows cannot use or 2 the drive capacity is too small 1 Check the drive capacity 2 Check that the parent folder exists 3 Check that the folder Screen Creator 5 uses is not deleted Refer to Section 2 2 File Configuration after Installation Saving the file failed Saving the file failed since 1 memory space is insufficient 2 the file or folder name is invalid or 3 disk free space is insufficient When this message appears the file may remain on the disk In this case delete it Saving data in operation failed Saving data in operation failed since 1 memory space is insufficient or 2 the parent window distinguishes When this message appears data component and program linked with the parent window may remain In this case delete it The functions of the video driver are insufficient The video driver embedded in Windows does not have enough functions to ma
23. 303 Cache overflow The size of the displayed bit map or the movable component exceeds that of the cache memory Make the bit map or the movable component small Inform the technical 7601 A stop request for logical switch feature was duplicated poe The global screen is not recorded The number of recorded logical switches exceeded the limit 640 77603 A SWWRITE request was received in the stop state of the logical switch function ld A message queue write error 7604 The specified switch is not recorded RB 7605 A parameter for a SWWRITE request is invalid 7606 A recording request was received in operating the logical switch pues A message queue open error A request of the occurrence of a touch panel event was received in the stop state of the logical switch function 7608 A occurrence request error for a touch panel event pom c com 7613 7614 A message queue write error SWWRITE 3 23 3 8 OIP Errors 7615 A message queue open error auto repeat switch Inform the technical 7616 A message queue write error auto repeat switch support of this company of 7617 A switch is specified which has not been recorded in the logical switch table SWWRITE 7618 A switch is specified which has not been recorded in the logical switch table SWWRITE 7623 A switch is specified which has not been recorded in the logical switch table SWREV or SWFIG 7624 A switch is specified which has not be
24. Cause Saving the component data cannot be performed Action This component cannot be arranged on the screen Thus delete it before use E205 Saving the program failed Cause Saving the program cannot be performed Action Write the program again E206 Creation or saving cannot be performed max count exceeded Cause Creation or saving cannot be performed since the number of input items exceeds the limit Action Reduce the number of input items for creation or saving 1 7 1 2 Errors during Screen Creator Operation E207 Cause Action E208 Cause Action E209 Cause Action E210 Cause Action 211 Cause Action E212 Cause Action E213 lt Cause gt lt Action gt E214 lt Cause gt lt Action gt A compile error exists A compile error exists since description on a screen or component program is invalid Correct the screen or component program error You can reference details of the error using the compile error in the reference bar The clipboard cannot be used The clipboard cannot be used since an error exists in Windows Terminate Screen Creator and restart Windows If the same error occurs after the restart reinstall Windows Data in the clipboard is invalid Data in the clipboard is invalid since an error exists in Windows Copy or paste data on the clipboard If an err
25. INGS IN OPERATING SCREEN CREATOR 1 2 Errors during Screen Creator Operation E231 No parent window exists Cause The parent window for the window in editing is closed because of its error Action Since the parent window is closed the window in editing is ineffective Click on the Close button for canceling it E232 No data exists in the library Cause The specified object texture or bit map does not exist in the library Action The drawn object has been deleted in the library Since the object on the screen is in effective delete it E233 same name standard function exists already Cause The name of the created user function is the same as that of the already existing standard function lt Action gt Give another name for saving E234 A syntax error exists in the function Cause syntax error exists in the created function Action Though being saved as it is the function cannot be used in a program Correct the error of the function before saving it E235 component file is invalid Cause The component file in the library is destroyed or the format in the file is invalid lt Action gt You cannot use the component Delete it from the library E236 The screen file is invalid Cause screen file is destroyed or the format in the file is invalid Action You cannot use the screen file Delete it E237 Creating a documentation file fail
26. In the K Basic CVB statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid In the K Basic CVW statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid In the K Basic CVI statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid In the K Basic CVF statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid In the K Basic CVID statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid In the K Basic MKB statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid 3 18 CHAPTER3 ERRORS AT OIP OPERATION 3 6 Errors during Operation Program Execution Countermeasure Action 5706 In the K Basic MKW statement Check the screen or the specified start position is invalid operation program that other than a character string type array variable is specified caused the error and the array variable subscr
27. RATION 3 6 Errors during Operation Program Execution Countermeasure Action 5763 In the K Basic FORMAT statement Check the screen or the specified drive or file name is invalid operation program that the file is not allocated capacity is zero caused the error and the RAM file is being opened correct it In the K Basic FSEEK statement the specified file number is invalid the base position or offset value is invalid 5765 In the K Basic MKDIR statement the directory name is invalid 5766 In the K Basic RMDIR statement the directory name is invalid 5767 In the K Basic CHDIR statement the directory or drive name is invalid 5770 In the K Basic KILL statement the file name is invalid 3 21 3 7_ Errors Caused with Too Many Messages Issued 3 7 Errors Caused with Too Many Messages Issued Error Code 6 OOO 6001 K Basic execution RUN JUMP OPEN SEND The error code at the time an error is detected is 6002 Serial reception CH1 not always associated with the excessive message The code of the last message is pene Hon CH displayed Thus check the screen running in the 6004 Serial reception CH3 error condition or the operation program and a 6005 Parallel input device that frequently issues a message Then 6006 Switch input correct the program to reduce the frequency of 3 22 ERRORS AT OIP OPERATION 3 8 OIP Errors 3 8 OIP Errors Error Code 7 O10 7
28. able is about to be declared with another type Change the variable name The variable has already been declared as a static variable The variable declared as a static variable is about to be declared with another type Change the variable name Plus minus conversion is not allowed Sign conversion is applied to an item other than a numeric constant or numeric variable Apply the sign conversion to only a numeric constant or numeric variable Operation with different types is not allowed Operation with different types is not allowed Correct the operation with the same type addition subtraction substitution etc Perform CONST declaration before use Constant declaration 1s used before CONST declaration Perform CONST declaration This CONST declaration has already been performed The same CONST declaration appears several times Perform declaration not to duplicate CONST declaration 2 4 2 ERRORS WARNINGS IN CREATING DATA 2 2 Errors in Compilation ECO18 Zero divisor occurs Cause The divisor is zero lt Action gt Delete the zero divisor ECO19 The number of dimensions mismatched that of the declared ones Cause The number of variable dimensions in K Basic is not equal to that of the declared ones lt Action gt Change the variable declaration 020 An error exists in the array declaration Cause number of dimensions is not a numeric for declari
29. an an integer array variable real number array variable 5303 5312 5313 5315 5318 5350 5351 5352 In the K Basic OPEN statement other than a component is specified the specified mode is invalid a member in grouped components is specified In the K Basic CLOSE statement other than a component is specified a member in grouped components is specified 3 9 3 6 Errors during Operation Program Execution Countermeasure Action 5354 In the K Basic MOVE statement Check the screen or other than a component is specified operation program that the specified moving method is invalid caused the error and a member in grouped components is specified correct it 5355 In the K Basic PMODE statement other than a component is specified the specified mode is invalid a member in grouped components is specified 5356 In the K Basic PSTAT statement other than a component is specified 5358 In the K Basic GETGNO statement other than a screen is specified 5361 In the K Basic RTSTAT statement other than a component is specified the selected code is invalid 5362 In the K Basic RSTAT statement the ID for a logical name is invalid the selected code is invalid 5363 In the K Basic REGISTOFFSET statement the specified logical name is invalid the specified offset value is invalid In the K Basic DSPMODE statement other than the designated control type is specified the specifi
30. an object that the OIP can execute An error detected during compilation is explained in Section 2 2 Errors in Compilation The second point is when downloading data is generated after screen data of all projects and operation programs are processed At this point operation programs that have not been compiled are compiled and other remaining processes are performed Thus all kinds of errors and warnings to be described in sections in this chapter may appear The error and warning messages involves Section 2 3 Errors in Creating Downloading Data Section 2 4 Warnings in Creating Downloading Data as well as Section 2 2 Errors in Compilation The above errors and warnings appear on the dialog bar in Screen Creator 5 lem CemalaqU biseri Tai Hah 5 1 g 1e malal mic mim ub S mrs Uz alale te Lots a Message type Message selection Information updating When you want to check details of an error or warning select the compile error in the Message type selection box and click on the Update information to the latest button An etror or warning message includes the name of a screen or component where it occurs If the error is detected in an operation program its message also includes line number where it occurs Notice that the error is detected in the line but its cause does not always exist on the line 2 2 CHAPTER2 ERRORS WARNINGS IN CREATING DATA 2 2 Errors in Com
31. be specified in an OPENCOM argument A logical device name must be specified as an argument in the OPENCOM function Specify a logical device name in an OPENCOM argument Only TKY BCR or HST can be specified in an OPENCOM argument The OPENCOM argument is invalid Specify only TKY BCR or HST in the OPENCOM argument An error exists in the function or command argument An error exists in a function or command argument Specify a correct argument This PIO has already been declared The same PIO is declared two or more times Declare the PIO only once The number of function arguments is invalid The number of function arguments is incorrect Specify correct arguments No device name can be used for an argument No device name can be used for a function argument Specify a correct argument The argument is not a variable A variable is not specified for a function argument that must be a variable Specify a correct argument The argument type is invalid The type of the function argument is incorrect Specify a correct argument The comparison type of the SELECT statement does not agree with that of the CASE statement The comparison type of the SELECT statement does not agree with that of the CASE statement Specify a correct type in the CASE statement 2 10 CHAPTER2 ERRORS WARNINGS IN CREATING DATA 2 2 Errors in Compilation ECO78 An error exists in the FOR NEXT statement Cause T
32. cause copy the file for editing to a file folder Then delete the original file When you have a backup file copy it E003 file cannot be read Cause The file cannot be read since 1 a wrong file or drive name is specified or 2 another application has opened the file Action 1 Check that the file or drive name is correct 2 Check that the file is not opened from another application E004 file cannot be written Cause The file cannot be written since 1 a wrong file or drive name is specified or 2 another application has opened the file Action 1 Check that the file or drive name is correct 2 Check that the file is not opened from another application 3 Check that the objective floppy disk is inserted in the drive 4 Check that the floppy disk medium is not write protected E005 file cannot be closed Cause The file cannot be written since 1 a wrong file or drive name is specified or 2 another application has opened the file Action 1 Check that the file or drive name is correct 2 Check that the file is not opened from another application 3 Check that the objective floppy disk is inserted in the drive 4 Check that the floppy disk medium is not write protected 1 3 1 2 Errors during Screen Creator Operation E006 Cause Action E007 Cause Action E008 lt Cause gt lt Action gt E009 lt Cause gt lt Action gt E
33. d Cause The upload editing is attempted even though no uploading has been performed yet Action Upload data from the panel with the project Upload function E250 The project is not downloaded Cause project file has not been transferred to the panel Action You must have transferred the project file at the time of downloading to make the upload editing effective E251 The uploaded project is destroyed Cause The uploaded project is destroyed Action Check that the disk system is working correctly or its capacity is sufficient Then execute the uploading again If the same error exists still you cannot perform the upload editing 1 3 Warnings during Screen Creator Operation 1 3 Warnings during Screen Creator Operation W 000 Cause Action 001 Cause Action W002 lt Cause gt lt Action gt W003 lt Cause gt lt Action gt W004 Cause Action W005 lt Cause gt lt Action gt W006 lt Cause gt lt Action gt W007 lt Cause gt lt Action gt W008 lt Cause gt Editing has already started You have selected a component for which editing has already started You being able to continue the editing since you can edit the selected component The number of colors is invalid The number of colors specified for a screen component or texture to be open does not agree with that of the current pr
34. declaration instead of the AUTO variable declaration 2 5 2 2 Errors in Compilation EC028 lt Cause gt lt Action gt EC029 lt Cause gt lt Action gt ECO030 Cause Action ECO3I Cause Action EC032 lt Cause gt lt Action gt ECO033 Cause Action ECO034 Cause Action EC035 Cause Action EC036 Cause Action ECO37 Cause Action A local or AUTO variable cannot be declared in FIELD A local or AUTO variable cannot be declared in the FIELD statement Use a GLOBAL STATIC or BACKUP variable in the FIELD declaration Variable initialization cannot be declared in FUNCTION or a subroutine Variable initialization cannot be declared in the FUNCTION statement or a subroutine Remove initializing variables other than an AUTO variable from the FUNCTION statement or a subroutine A local variable cannot be declared in a global screen or library function A local variable cannot be declared in a global screen or library function Cancel the local variable declaration In a global screen use a GLOBAL STATIC or BACKUP variable In the library function use the AUTO variable A value of the argument is invalid in checking a local variable The description of the argument violates the LOCAL CHECK statement syntax Check the argument type An error exists in the array element declaration A nonnu
35. e versions of Screen Creator generation downloading data and of the OIP system Then contact the technical support of this company 3871 Flush ROM write error ROM 1 Perform downloading again If the same 3872 Flush ROM write error ROM 2 error still occurs contact the technical 3874 Flush ROM write error ROM 3 Support of this company 3878 Flush ROM write error ROM 4 3 6 ERRORS AT OIP OPERATION 3 5 Errors during Message Process 3 5 Errors during Message Process Error Code 4 100 Check the screen or operation program that 4300 In the K Basic JUMP statement a screen that has not been recorded is specified 4310 In the K Basic OPEN statement anon existing component is specified a member in group components is specified an internal data error in the module occurs A not ESUDPOREG message was received Check the versions of Screen Creator 4510 generation downloading data and of the OIP 4520 overtiow system Then contact the technical support of this company 3 7 3 6 Errors during Operation Program Execution 3 6 Errors during Operation Program Execution Error Code 5 00 5002 The memory area is insufficient The used amount of the 5003 The K Basic work area is insufficient system or backup memory NOE um exceeds the OIP capacity 5004 The backup memory capacity is insufficient Check the used amo ntof the memory with Screen Creator If the backup
36. eate a function or cancel the reference of the non existing function ELO24 Substance of Subroutine does not exist Cause The substance of the called subroutine does not exist Action Create a subroutine or cancel the reference of the non existing subroutine 2 13 2 3 Errors in Creating Downloading Data EL030 Cause Action ELO31 lt Cause gt lt Action gt EL040 lt Cause gt lt Action gt EL041 Cause Action ELO050 Cause Action EL060 lt Cause gt lt Action gt EL061 lt Cause gt lt Action gt EL062 lt Cause gt lt Action gt EL063 lt Cause gt lt Action gt Texture TEX does not exist The texture used in the program or control does not exist 1 Create the texture 2 Copy a texture and record it Texture TEX is destroyed The texture may be destroyed Re create the texture Bit map BMP does not exist The bit map used in the screen or texture does not exist 1 Create a bit map 2 Copy a bit map and record it Bit map BMP is destroyed The bit map may be destroyed Re create the bit map Character string does not exist The character string used in the program does not exist 1 Create the character string 2 Copy acharacter string and record it An error in the connected equipment PLC The PLC of this type is not supported This compiler
37. ed Cause The documentation file cannot be created Action 1 Check the specified name of a file or folder 2 Check the disk free space 3 Check the memory capacity E238 The timer cannot be used lt Cause gt The timer function Windows offers cannot be used lt Action gt Other applications use all timers or an error exists in Windows Terminate the other applications or restart Windows E239 The execution file cannot be started Cause The execution file cannot be started since 1 memory space is insufficient 2 the execution file PA EXE is destroyed or does not exist or 3 an error exists in Windows lt Action gt Restart Windows and start Screen Creator If an error still occurs reinstall Screen Creator 1 11 1 2 Errors during Screen Creator Operation E240 Cause Action E241 lt Cause gt lt Action gt E242 Cause Action E243 Cause Action E244 Cause Action E245 Cause Action E246 Cause Action E247 Cause Action E248 Cause Action Storing to the library failed Storing to the library cannot be performed since 1 memory space is insufficient or 2 an error exists in Windows Restart Windows and re execute processing The project is duplicated No project can be duplicated Give another number for recording Copying the project failed Copying
38. ed Cause You cannot perform device editing since the screen file is left open Action The device editing function updates a screen file Thus all screens must have been closed before the device editing If screen update is necessary perform Create in the downloading function 1 3 Warnings during Screen Creator Operation W017 global screen can be recorded Cause global screen has been recorded Action Do not record a global screen W018 component cannot be reduced since its control sticks out of the control area Cause When a numeric indicator character indicator or clock indicator control exists in component the component area cannot be smaller than the control size Action Adjust the control length for a numeric indicator character indicator or clock indicator before reducing the component size 1 16 CHAPTER 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 2 ERRORS WARNINGS IN CREATING DATA 2 1 2 1 Errors Warnings in Creating Data 2 1 Errors Warnings in Creating Data This chapter describes error and warning messages appear during data creation The data creation is performed in the following two points The one point is when an operation program written in K Basic for a screen component is saved When Compile at saving a screen is set the program is compiled at the time of saving The compile means that program syntax is checked and translated into
39. ed mode is invalid In the K Basic NUMFORM statement other than a numeric control is specified the specified displaying method is invalid 5402 In the K Basic STRFORM statement other than the designated character control is specified the specified displaying method is invalid 5403 In the K Basic FIGFORM statement other than a figure indicator is specified the specified re sizing is invalid 5404 In the K Basic ROTATE statement other than the designated control type is specified the specified rotational angle is invalid 5405 In the K Basic RANGE statement other than the designated control type is specified Zero divisor occurs 5406 The K Basic CLEAR statement causes a specification of other than the NX designated control type 5407 The K Basic NUMDSP or LAMPDSP statement causes a specification of other than a numeric indicator or lamp control 5408 The K Basic NUMDSP statement causes a specification of other than a pee numeric indicator 5409 The K Basic STRDSP statement causes a specification of other than a character indicator 5410 The K Basic STRDSP statement causes a specification of other than a character indicator 5411 The K Basic FIGDSP statement causes a specification of other than a figure indicator 3 10 ERRORS AT OIP OPERATION 3 6 Errors during Operation Program Execution 5412 The K Basic FREDSP SLDDSP or MTRDSP statement causes a Check the screen or speci
40. en and the other is at the bottom of the screen You can specify the error displaying location in Error display setting in System setting in the OIP main body The following two figures represent that the error message is displayed on the error indicator and at the bottom of the screen Error display on the error indicator On the error indicator the Various error information window displays such error information as an error type a four character error code screen number and component number At he center of the indicator brief explanation of the error is displayed Warning message xxxx Screen ID yyyy Parts ID ZZZZ Error display at the bottom of the screen At the bottom of the screen the Various error information section displays such error information as an error type a four character error code screen number and component number At he center of the 3 2 ERRORS AT OIP OPERATION 3 1 Error Display at OIP Operation indicator brief explanation of the error is displayed Errors that possibly occur are classified into the types listed in the following table The error codes and their explanations are presented in the next and following pages in the order of the codes main CPU error communication uploading error operation message operation program excessive message in a peripheral device the OIP The errors listed in the following table
41. en recorded in the logical switch table function stop 7625 A switch is specified which has not been recorded in the logical switch table function restore 7626 A switch is specified which has not been recorded in the logical switch table mask change A switch is specified which has not been recorded in the logical switch table switch display A module internal data error management information 7650 The number of recorded logical switches exceeded the limit 640 An invalid setting value of downloading data 7651 A sub module start error auto repeat switch Wu ee 7655 A message queue open error auto repeat switch 7656 A message queue write error auto repeat switch 7657 A switch is specified which has not been recorded in the logical switch table SWWRITE 7658 A switch is specified which has not been recorded in the logical switch table SWWRITE 3 24 CHAPTER3 ERRORS AT OIP OPERATION 3 8 OIP Errors Countermeasure Action 7659 A message queue write error turning off a momentary switch Inform the technical 7660 A logical switch table error terminator code support of this company of A the error code message queue write error 7661 A logical switch table error switch position or area size A module internal data error 7662 A message queue handle value error SWWRITE A logical switch module operation error A switch is specified which has not been recorded in the logical switch table SWREV
42. eral Devices 3 9 Errors in Peripheral Devices Error Code 8 OOO such as memory cards 8811 A file format error of the MS DOS file system in the RAM drive memory file 8812 The memory file of the MS DOS file system in the RAM drive is write protected 8813 The memory file of the MS DOS file system in the RAM drive cannot be accessed 5 3 27
43. ers is invalid an argument variable type is invalid an array variable subscript is invalid 5671 In the K Basic MID statement the specified record character string number is invalid the specified start position is invalid the specified number of characters is invalid an argument variable type is invalid an array variable subscript is invalid 5672 In the K Basic MID statement the specified record character string number is invalid the specified start position is invalid the specified number of characters is invalid an argument variable type is invalid an array variable subscript is invalid 5673 The K Basic DATES statement causes a read error of a clock indicator 5674 The K Basic TIMES statement causes a read error of a clock indicator 5675 The K Basic LEN statement causes an invalid specification of a f mies 5676 In the K Basic INSTR statement the specified record character string number is invalid the specified start position is invalid 5677 In the K Basic LEFT statement the specified record character string number is invalid the specified number of characters is invalid 5678 In the K Basic RIGHTS statement the specified record character string number is invalid the specified number of characters is invalid 5679 In the K Basic MID statement the specified record character string number is invalid the specified start position is invalid the specified number of characters
44. fication of other than the designated control type operation program that 5413 The K Basic PLTDSP statement causes a specification of other than a caused the error and plot graph correct it 5414 In the K Basic BARDSP or BLTDSP statement other than the designated control type is specified the specified bar zone number is invalid In the K Basic LNEDSP statement other than a line graph is specified the specified line number or point number is invalid 5416 In the K Basic BARSHIFT statement other than a bar graph is specified the specified shift direction is invalid 5417 In the K Basic LNESHIFT statement other than a line graph is specified the specified line number or point number is invalid 5418 In the K Basic NUMCOLOR STRCOLOR or PLTCOLOR statement other than the designated control type is specified the specified display color is invalid the specified tile for color or back color is invalid 5419 In the K Basic FIGCOLOR statement other than a figure indicator is specified the specified tile for color or back color is invalid 5420 In the K Basic FRECOLOR statement other than a free graph is specified specified tile 1 for color 1 or back color 1 is invalid specified tile 2 for color 2 or back color 2 is invalid 5421 In the K Basic LNECOLOR statement other than a line graph is specified the specified line number is invalid the specified line type or l
45. gain 2 Check that the computer file system is healthy ELO009 Creating data for Screen failed Cause 1 Free space in the project folder is too small 2 Anerror may occur in your computer Action Check the free space ELO10 Control does not exist Cause control written in the program does not exist Action Check the program and correct it on an as needed basis ELO020 variable types are different between Screen Component and Screen Component Cause declaration types of the global backup variables are mismatching which are used with two or more positions lt Action gt Correct the program ELO21 The variable types are different between Screen Component and the system function Cause declaration types of the global backup variables are mismatching which are used with two or more positions Action Correct the program ELO22 The initialization information exists in two places Screen Component and Screen Component Cause Initialization for the global backup variables shared by two or more programs at the time of declaration is performed in two or more places Action Correct the programs ELO23 Substance of Function does not exist Cause This error may occur if a function is deleted or a function name is changed after creation of the screen Action Cr
46. he attribute dialog box is not displayed click on the Current attribute button on the drawing tool bar The texture file is invalid The texture file in the library is destroyed or the format in the file is invalid Open the texture with the library menu If the file can be open store it If it cannot be open you cannot use it Thus delete it The texture name has not been entered yet A texture is about to be created on the screen before entering a texture name in the attribute dialog box Enter a texture name in the dialog box If the attribute dialog box is not displayed click on the Current attribute button on the drawing tool bar The switch control cannot be transformed since being overlapped with another one The transformed switch control is overlapped with another one No switch controls can be overlapped with each other Specify an area overlapping with another one No component can be deleted in editing Deletion is attempted to a component whose contents are being edited You cannot delete a component whose contents are being edited Close the sub window in editing for termination the editing Then delete it No editing can be performed during editing contents A component is about to be transformed while its contents are being edited You cannot transform a component whose contents are being edited Close the sub window in editing for termination the editing Then transform it 1 10 CHAPTER 1 ERRORS WARN
47. he comparison type of the SELECT statement does not agree with that of the CASE statement Action Correct the error in the descriptions in the FOR TO statements EC079 No device is used in the specified control Cause A device must be specified in the control when the ADDCYC ADDCYC2 or ADDCYCID statement is used Action Check the program to be whether a device is specified or the ADDCYC statement is used ECO080 The type cannot be specified in a global variable Cause You attempted to combine a variable which cannot be a global variable when a screen file is linked Action Contact the technical support of this company 2 3 Errors in Creating Downloading Data 2 3 Errors in Creating Downloading Data ELO000 Cause Action 1 Cause Action EL002 Cause Action EL003 Cause Action ELO004 lt Cause gt lt Action gt ELOOS5 Cause Action ELO06 lt Cause gt lt Action gt EL007 Cause Action The component area exceeds the screen area A component is arranged outside the usable screen area Change the arranging position of the component An invalid control exists in Screen or Component A control that this compiler cannot recognize is arranged Screen or component data may be destroyed Delete the control used for the component and arrange a control again If not being
48. he destination are displayed in the lower the PLC is not connected the investigation should be 2255 three digits of the error codes CH1 centered on devices that do not exist on the PLC side 2300 Errors at the destination Error codes at to the destination plus 300 are displayed in 2555 the lower three digits of the error codes CH2 2600 Errors at the destination Error codes at to the destination plus 600 are displayed in 2855 the lower three digits of the error codes CH3 Check that the communication conditions agree with the Receive data error CH1 Check the receiving date format The investigation should be centered on the presence absence of a checksum 2905 Timeout error CH1 Check the following items Communication cables PLC station number Setting value of time out interval Destination condition Link unit settings Same as Same as CHI 3 5 3 4 Errors during Downloading Uploading 3 4 Errors during Downloading Uploading Error Code 3 OOO Perform downloading again If the same error still occurs contact the technical PM AE Perform downloading again If the same error still occurs contact the technical The specified transfer rate is invalid Check the versions of Screen Creator generation downloading data and of the OIP system Then contact the technical support of this company Perform downloading again If the same error still occurs contact the technical 3684 Invalid BID Check th
49. his manual please contact our customer support in Sales Division of Koyo Ltd 4 We shall have no liability to any loss or damage caused or alleged to be caused directly or indirectly by the statements contained in this manual or by the computer software and hardware products described in it 5 Koyo Ltd may have patens or pending patent applications copyrights or other intellectual property rights covering subject matter in this manual The furnishing of this manual does not give you any license to these patents or other intellectual property rights And we do not have any responsibility on troubles involved in the patents and other intellectual rights caused by the use of this manual 6 Contact us at the following place concerning other unclear points in this manual Overseas Division Koyo Electronics Industries Co Ltd Address 1 171 Tenjin cho Kodaira Tokyo 187 japan Telephone 81 42 341 7711 Facsimile 81 42 342 6871 Notice Version Up Koyo Ltd has upgraded Screen Creator 5 for adding new functions operationability and so forth Below will be introduced the updated functions 1 Version 2 10 Supporting middle size systems GC53 of GC5x Series Adding the uploading editing function To make this function effective attach all screen data and K Basic programs used in the project and download them to the panel Then download the uploaded entities from the panel and restore them Then you can edit the data and
50. ied the specified ON1 ON2 OFF state is invalid the specified color in the pile is invalid 5450 In the K Basic SWMODE statement other than a switch control is specified the specified model is invalid 5451 In the K Basic SWWRITE statement other than a switch control is specified the specified status is invalid 5452 The K Basic SWREAD statement causes a specification of other than a switch control 3 12 CHAPTER3 ERRORS AT OIP OPERATION 3 6 Errors during Operation Program Execution 5453 In the K Basic SWREV statement Check the screen or other than a switch control is specified operation program that the specified operation is invalid caused the error and 5454 In the K Basic SWFIG statement RENE other than a switch control is specified the specified a sub switch number is invalid the specified status is invalid 5455 In the K Basic PRMCTLI statement other than the designated control switch control type is specified the specified selection code is invalid control switch control setting is invalid 5456 In the K Basic PRMSTATI statement other than the designated control switch control type is specified the specified selection code is invalid 5457 In the K Basic PRMCTL2 statement other than the designated control switch control type is specified the specified selection code is invalid the specified auxiliary selection is invalid 5458 In K Basic PRMSTAT 2 stateme
51. ine color is invalid the specified tile for color or back color is invalid 5422 In the K Basic BLTCOLOR or CIRCOLOR statement other than the designated control type is specified the specified zone number is invalid the specified tile for color or back color is invalid 5423 In the K Basic MTRCOLOR or LAMPCOLOR statement other than a meter or lamp is specified the specified display color is invalid 5424 In the K Basic BARCOLOR statement other than a bar graph is invalid the specified bar number is invalid specified tile 1 for color 1 or back color 1 is invalid specified tile 2 for color 2 or back color 2 is invalid 5425 The K Basic STRDSP statement causes a specification of other than a character indicator 5426 The K Basic FIGDSP statement causes a specification of other than a figure indicator 5427 The K Basic PRDSP statement causes a specification of other than the designated control type 3 6 Errors during Operation Program Execution 5428 In the K Basic BARSET BLTSET or CIRSET statement Check the screen or other than the designated control type is specified operation program that the specified bar zone number is invalid caused the error and 5429 In the K Basic LNESET statement Correct S other than a line graph is specified the specified line number or point number is invalid 5430 In the K Basic LNESHIFT2 statement other than a line graph is specified
52. ipt is invalid correct it 5707 In the K Basic MKI statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid 5708 In the K Basic MKF statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid 5709 In the K Basic MKID statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid 5710 In the K Basic MKS statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid 5713 In the K Basic LPAD statement other than a character string type array variable is specified the array variable subscript is invalid 5714 In the K Basic RPAD statement other than a character string type array variable is specified the array variable subscript is invalid 5715 In the K Basic INS statement the specified start position is invalid other than a character string type array variable is specified the array variable subscript is invalid 5716 In the K Basic MCPY statement the specified file number is invalid other than a character string type array variable is specified the array variable subscript is invalid the
53. is invalid an argument variable type is invalid an array variable subscript is invalid 5680 In the K Basic INPBIT statement the specified port number is invalid the specified bit number is invalid 3 6 Errors during Operation Program Execution Countermeasure Action 5681 In the K Basic OUTBIT statement Check the screen or the specified port number is invalid operation program that the specified bit number is invalid caused the error and 5682 The K Basic OUTSTAT statement causes an invalid specification of a 5683 In K Basic OUTBITSTAT statement the specified port number is invalid the specified bit number is invalid The K Basic LEN statement causes an invalid specification of a recorded character string number In the K Basic INSTR statement the specified record character string number is invalid the specified start position is invalid In the K Basic LEFT statement the specified record character string number is invalid the specified number of characters is invalid In the K Basic RIGHTS statement the specified record character string number is invalid the specified number of characters is invalid In the K Basic MID statement the specified record character string number is invalid the specified start position is invalid the specified number of characters is invalid an argument variable type is invalid the array variable subscript is invalid
54. k Delete the subroutine The INIT block has already been declared Two or more INIT blocks are declared Declare one INIT block The CONF block has already been declared Two or more CONF blocks are declared Declare one CONF block The EVNT block has already been declared Two or more EVNT blocks are declared Declare one EVNT block An EVNT block cannot be specified in a global screen An event block is specified in a global screen Delete the event block 2 8 CHAPTER2 ERRORS WARNINGS IN CREATING DATA 2 2 Errors in Compilation ECO58 The start and end block declarations are invalid Cause start block declaration does not correspond to the end block declaration Action Declare the start and end blocks correctly EC059 The same name function has already been declared Cause The function declaration is duplicated Action Do not duplicate the function declaration ECO060 The specified function is not declared Cause specified function is not declared Action Declare DECLARE the function EC061 The function argument is not the declared one Cause The function argument is not the declared one Action Declare the function correctly EC062 Only a constant or variable can be specified as an argument for function Cause The function argument is other than a constant or variable Action Specify a function argument correctly EC063 The n
55. ke drawing with Screen Creator Displaying may not be performed normally It is necessary to change the video driver hardware or software installed in your computer Copying a file failed Copying a file failed since an invalid folder or file name is specified Check that the file and folder names on the source and destination are correct 1 The disk capacity is sufficient 2 destination file is not write protected The tool bar layout is invalid The position information of the tool bar recorded in the initial file INI file is invalid When this message appears the tool bar position is returned to the default position 1 4 CHAPTER1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 2 Errors during Screen Creator Operation E013 Internal data 15 invalid Cause error exists in the Windows memory or control that Screen Creator uses Action Terminate Screen Creator and restart Windows If no error occurs after restarting Windows then start Screen Creator E014 Configuring a library failed Cause Configuring a library file filed during Screen Creator installation You cannot continue the following operations Action Terminate Screen Creator and reinstall all E100 Reading the initial file PA INI failed Cause The initial file PA INI in the execution folder is invalid You cannot read it Action Copy the PA INI file to another folder for investigation and delete it Then res
56. l data created by Screen Creator again ELO71 The connection equipment information file does not exist Cause The connection equipment information file is not found Action Install Screen Creator 5 again EL080 The backup memory capacity exceeds 63 KB Cause capacity of the backup memory exceeds that of the OIP memory Action Change the operation program to reduce using amount of the backup memory The using amount of the backup memory includes the allocated memory file capacity set by the OIP and the upper limit is 63 KB Thus if this error does not occur the OIP may detect the error during downloading 2 15 2 4 Warnings in Creating Downloading Data 2 4 Warnings in Creating Downloading Data WLOOO lt Cause gt lt Action gt WLOOL lt Cause gt lt Action gt WLO002 Cause Action WLO10 Cause Action WLOI I Cause Action WLO020 Cause Action WLO21 lt Cause gt lt Action gt Screen 1s not recorded The screen used in the program is not recorded Record the screen Component does not exist The component used in the program is not found Arrange the component Texture TEX has been changed The size of the texture used in the Slider control has been changed after screen data creation Go into Edit contents of the component using Slider and check the texture Function
57. may occur in addition to the above ones Countermeasure Action Insufficient capacity of the system The used RAM memory exceeds the system memory RAM limit Check the used system memory capacity Insufficient number of the system referencing Used Memory List in Screen Creator 5 RAM Invalid clock operation note The clock IC operation is unstable This error may occur when the back up battery voltage is low If you do not use the clock function set 1 to the clock operation error mask in the Action Parameter in the Error Indicator Battery voltage drop note The OIP backup battery has been exhausted Replace the battery If you do not want to detect this error set 1 to the battery voltage drop error mask in the Action Parameter in the Error Indicator Note Since a backup battery cannot be fixed to GC53LC LM this error does not occur 3 3 3 2 Errors at Main CPU Detecting Trouble 3 2 Errors at Main CPU Detecting Trouble Error Code 1 DOO Check the versions of Screen Creator generation downloading data and of the OIP system Then contact the technical support of this company 100 1012 16 Interrupt at main CPU to 1063 3 4 ERRORS AT OIP OPERATION 3 3 Errors during Serial Communication 3 3 Errors during Serial Communication Error Code 2 00 2000 Errors at the destination Error codes at Check the destination error code and take measures If to t
58. ment variable type Invalid array variable subscript PLC device read error Memory table read error 3 8 ERRORS AT OIP OPERATION 3 6 Errors during Operation Program Execution Error Code 5222 In the K Basic DEVWR statement Check the screen or the PLC device ID is invalid operation program that e a PLC device write error occurs caused the error and In the K Basic DEVRD statement the PLC device ID is invalid the argument variable type is invalid the array variable subscript is invalid a PLC device write error occurs 3253 5268 5267 5269 In the K Basic GETOFFSET statement the operated ID type is invalid an operation between different types occurs the PLC device ID is invalid In the K Basic GETID statement the operated ID type is invalid the PLC device ID is invalid In the K Basic SHIFT statement other than an integer array variable is specified the array variable subscript is invalid In the K Basic BITSET statement other than an integer array variable is specified the array variable subscript is invalid In the K Basic BITSET statement other than an integer array variable is specified the array variable subscript is invalid In the K Basic EXECPRCODE statement other than the designated indicator is specified the X Y specified value is invalid specified is the subscript for an array variable for which other th
59. mer number is specified atimer in use is specified 5573 In the K Basic STARTTIM statement e an invalid timer number is specified atimer in use is specified 5574 The K Basic STOPTIM statement causes an invalid specification of a 5575 In the K Basic CONTTIM statement the specified timer number is invalid a Working timer is specified 3 15 3 6 Errors during Operation Program Execution timer number operation program that timer number correct 1t The K Basic COLOR statement causes an invalid specification of a display color line type or line width dot size The K Basic PATTERN statement causes an invalid specification of a filling pattern for color or back color setting releasing The K Basic SETBLIGHT statement causes an invalid specification of the automatic turn off time of the backlight The K Basic GETBLIGHT statement causes an invalid specification of the automatic turn off time of the backlight 5611 The K Basic LOOKSYS statement causes an invalid setting 5612 The K Basic PRM LOAD statement causes an invalid setting The K Basic TTYREAD statement causes an invalid setting 5621 The K Basic SETANGLE statement causes an invalid setting of display brightness 5622 The K Basic GETANGLE statement causes an invalid setting of display brightness 5623 The K Basic ERRCTL statement causes an invalid setting 5627 The K Basic GETBOOTVER statement causes an invalid setting 5650 The K Basic INP
60. meric value is specified for a subscript when the array variable element is designated Specify a numeric value to a subscript to access an array variable A variable of ID type cannot be initialized A variable of ID type cannot be initialized Do not initialize a variable of ID type The device name is invalid The description of the device name is invalid Specify a correct device name An error exists in the device name declaration An error exists in the device name declaration Specify a correct device name An error exists in the device name description The name is too long An error exists in the device name description The name is too long Specify a correct device name This device is write protected This device is write protected Do not apply write operation to a write protected 2 6 CHAPTER2 ERRORS WARNINGS IN CREATING DATA 2 2 Errors in Compilation ECO38 No device can be used since the PLC is not set in the connection device Cause No device can be used since the PLC is not set in the connection device Action Set PLC in the connection device EC039 CYCLIC2 declaration cannot be applied to the device Cause CYCLIC2 declaration cannot be applied to the device Action Do not apply the CYCLIC2 declaration to the device EC040 The device name specification is outside the range Cause The device name specifies the outside of the permitted range Action
61. ng an array variable Action Declare the number of dimensions for an array variable with a numeric value ECO21 An error exists in setting the variable size for the character string type Cause character string length is not numeric or the type specifier of the variable is not Action Specify a correct character string length and type specifier 022 An error exists in initializing the variable Cause error exists in initializing the variable lt Action gt Set initializing data as many as elements for array variables ECO23 The initializing character string is too long Cause The initializing character string is too long Action Specify initializing data within the length of the character string in the character string variable ECO24 Field declaration error Cause description of field declaration violates the FIELD statement syntax Action Declare it correctly ECO25 The same local variable name is declared Cause The same local variable name is declared Action Change the local variable name with the duplicate declaration EC026 Another type variable is declared with the same name Cause Another type variable is declared with the same name Action Change the variable name ECO27 AUTO variable can be declared only in FUNCTION Cause AUTO variable can be declared only in the FUNCTION statement Action Use the LOCAL
62. not opened 3 13 3 6 Errors during Operation Program Execution Countermeasure Action 5504 In the K Basic REOPENCOM statement Check the screen or e a logical device other than serial communication is specified operation program that the specified logical device is not opened caused the error and 5505 In the K Basic CLOSEPARALLEL statement an invalid parallel input 201108 it bit number is specified 5506 In the K Basic CLOSEPARALLEL statement an invalid parallel input bit number is specified 5507 In the K Basic IOCTL statement an invalid control I O number or status selection value is specified 5508 In the K Basic IOSTAT statement an invalid control I O number or status selection value is specified 5509 In the K Basic OPENSIO statement an invalid channel number is specified an invalid communication mode is specified other than a character type array variable is specified an array variable subscript is invalid an invalid variable as a receive buffer is specified a local variable or size zero variable an already opened serial port is specified 5510 In the K Basic CLOSESIO statement an invalid channel number is specified e a serial port that has not been opened is specified 5511 In the K Basic SETSIO statement an invalid channel number is specified areceive text length is invalid a port opened in the binary mode e a serial port that has not been opened is specified 5512 In the K Ba
63. nt other than the designated control switch control type is specified the specified selection code is invalid the specified auxiliary selection is invalid 5459 In the K Basic PRMCTL3 statement other than the designated control switch control type is specified the specified selection code is invalid the specified auxiliary selection is invalid indicator switch setting is invalid 5460 In the K Basic PRMSTATS statement other than the designated control switch control type is specified the specified selection code is invalid the specified auxiliary selection is invalid 5461 In the K Basic PRMCTL4 statement other than the designated control switch control type is specified an invalid selection code is specified 5462 In the K Basic PRMSTATA statement the designated control switch control type is specified the specified selection code is invalid the specified auxiliary selection is invalid 5500 In the K Basic INPUT statement an invalid subscript for an array 80 NN 5501 In the K Basic PRINT statement an invalid subscript for an array variable is specified the send message buffer overflows 5502 In the K Basic SEND statement adestination that cannot receive messages is specified the specified logical device is specified which cannot send messages 5503 In the K Basic CLOSECOM statement alogical device other than serial communication is specified the specified logical device is
64. oject When the data is open its color setting is changed to that of the project If you do not like the resultant color correct it Select a class for storing The class belonging to the component is not selected when the component is saved to a library Select a class in the dialog for saving the component Undo cannot be executed The Undo function cannot be executed since a component being edited in the sub window is affected with the function Close the sub window for editing contents for re execution The drawn background was not saved You can arrange only component on the project global screen No background is saved even it drawn Arrange only a component on the global screen Nothing is selected Nothing is selected for an operation for which selection is needed The specified operation is ineffective First selection is made for the operation No group component can be edited Grouped components cannot be edited alone Arrange them on the screen Then edit them on the screen individually The component has been made movable A fixed component is arranged on the project global screen Any component needs to be movable on the global screen A non movable component is made movable Select only one component More than one component is selected for the operation 1 14 CHAPTER1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 3 Warnings during Screen Creator Operation Action Select only one
65. or occurs again restart Windows If the same error still occurs after restarting Windows re install Windows Undo cannot be executed The Undo function cannot be executed since previous operation caused an error Try another operation and execute the Undo function If the error occurs still restart Screen Creator and Windows Executing Undo failed Executing the Undo function failed since previous operation caused an error Try another operation and execute the Undo function If the error occurs still restart Screen Creator and Windows Redo cannot be executed The Redo function cannot be executed since previous operation caused an error Try another operation and execute the Redo function If the error occurs still restart Screen Creator and Windows Executing Redo failed Executing the Redo function failed since previous operation caused an error Try another operation and execute the Redo function If the error occurs still restart Screen Creator and Windows Create or Edit failed Executing the Create or Edit function Terminate Screen Creator and restart Windows If this error still occurs delete and recreate it since an error exists in the editing file 1 8 CHAPTER 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 2 Errors during Screen Creator Operation E215 object larger than the area cannot be arranged Cause Since larger than the area the component texture or bit map to be arranged
66. ounding is used for the protective grounding terminal There is a possibility of electrical shock if the unit is not grounded If the OIP should malfunction immediately turn off the poser and leave it alone If there is direct output to external output device such as PLCs direct output will be driven regardless of the ladder circuit interlock Output may be used to drive motors and the like so avoid using direct output because it is dangerous N CAUTION Use and store the OIP in the environment described in the specifications regarding vibration shock temperature humidity etc Do not use the OIP where it is subjected to inflammable or explosive gas or steam Before turning on the power be sure that the power voltage rating of the OIP and the voltage rating power supply match Using a mistaken power supply can damage the unit Do not disassemble or modify the OIP Doing so can cause malfunctions and lead to other problems The OIP touch panel is made of glass Striking it with hard objects or pressing hard on it may break the glass Do not push down on the OIP touch panel with mechanical pencils screwdrivers or other sharp objects Doing so can damage the touch panel or cause malfunctions Safety Precautions Notations Used In This Manual Notations Used In This Manual This manual uses the following symbol marks for you to use this system comfortably N WARNING Caution Note Describes a peril
67. ows E222 No grouped part is selected Cause editing function you applied cannot be executed without a grouped component selected Action Select a grouped component before applying the editing function When selecting a parent component you can edit all components in the group 1 9 1 2 Errors during Screen Creator Operation E223 lt Cause gt lt Action gt E224 lt Cause gt lt Action gt E225 lt Cause gt lt Action gt E226 lt Cause gt lt Action gt E227 lt Cause gt lt Action gt E228 lt Cause gt lt Action gt E229 lt Cause gt lt Action gt E230 lt Cause gt lt Action gt No character string is entered A character string is about to be created on the screen before entering a character string in the attribute dialog box Enter a character string in the dialog box If the attribute dialog box is not displayed click on the Current attribute button on the drawing tool bar The bit map file is invalid The bit map file in the library is destroyed or the format in the file is invalid Load the file with Paint If the file can be read with Paint store it If it cannot be read with this accessory you cannot use it Thus delete it The bit map name has not been entered yet A bit map is about to be created on the screen before entering a bit map name in the attribute dialog box Enter a bit map name in the dialog box If t
68. parison 2 7 2 2 Errors in Compilation Action EC048 lt Cause gt lt Action gt EC049 lt Cause gt lt Action gt EC050 lt Cause gt lt Action gt EC051 lt Cause gt lt Action gt EC052 lt Cause gt lt Action gt EC053 lt Cause gt lt Action gt EC054 lt Cause gt lt Action gt EC055 lt Cause gt lt Action gt EC056 lt Cause gt lt Action gt EC057 lt Cause gt lt Action gt Specify a memory table number with an integer An error exists in the memory table declaration An error exists in the memory table declaration Specify a correct memory table No outside device is set No outside equipment is set Specify a declared device as outside equipment The library function source does not exist The library function source does not exist The library function you want to use cannot be found Check that the library function exists Only one function block can be declared Two or more functions are created at the same time in the library function creation feature Create one library function at a time The specified library function does not exist The specified library function does not exist The library function you want to use cannot be found Check that the library function exists No subroutine can be specified in a function block No subroutine can be specified in a user defined function bloc
69. pilation 2 2 Errors in Compilation EC000 Memory space is insufficient Cause Memory space is not enough to compile a program or an error exists in Windows lt Action gt Terminate Screen Creator and restart Windows If no error occurs after restarting Windows then start Screen Creator ECOO An error exists Cause error is detected which does not belong to any errors described in this section Action Contact the technical support of this company EC002 The character string is too long Cause The character string is too long Action Make the character string in no longer than 80 bytes One alphanumeric character is one byte But one two byte character consists of two bytes ECO003 An error exists in character string constant Cause error exists in character string constant Action Eliminate the error A character string constant is enclosed with double quotes EC004 Memory space cannot be allocated Cause Memory space cannot be allocated Action Contact the technical support of this company 005 Memory space cannot be allocated in the heap area Contact the selling agency Cause Memory space cannot be allocated in the heap area Action Contact the technical support of this company 006 An error exists in writing K Basic Cause error exists in writing K Basic Action The description violates the K Basic syntax Check several
70. programs Note that the data with the project attached increase their size The following PLCs have been added Koyo Koyo KOSTAC SA SR a Omron SYSMAC a Fuji Dennki FLEX PC NJ T NS T Fuji Dennki Computer link protocol Fuji Dennki Loader command protocol Toyota Koki PCI Toyota Koki PC3 Matsushita Electric Industry 7000 Standard components centered on the parts used for middle size systems GC53 in the GC5x Series have drastically been added vii 1 ERRORS WARNINGS IN OPERATING SCREEN CREATOR 1 1 Errors and Warnings in Operating Screen Creator 1 1 Errors and Warnings in Operating Screen Creator This chapter explains errors and warnings when you operate Screen Creator An error occurs in operating on Screen Creator in a wrong procedure or in detecting trouble to continue processing The error since indicating that you cannot continue processing anymore must be eliminated or another way of operation is needed A warning message is issued to turn the operator s eyes on something wrong such as the operation procedure of Screen Creator is invalid or unpredictable result may occur Viewing the warning message you should examine it closely and remove its cause continue the processing intentionally as it is change the operation etc An error or warning message appears in a dialog box in operating Screen Creator The following figures show an error and warning message examples IN
71. rd buffer is not declared no declaration at FOPEN the RAM file overflowed 5755 In the K Basic LINPUT statement the specified file number is invalid the specified record number is invalid the file number not opened is specified the record buffer is not declared no declaration at FOPEN the RAM file overflowed 5756 In the K Basic FPUT statement the specified file number is invalid the specified record number is invalid the file number not opened is specified the record buffer is not declared no declaration at FOPEN the RAM file overflowed 5757 In the K Basic FGET statement the specified file number is invalid the specified record number is invalid the file number not opened is specified the record buffer is not declared no declaration at FOPEN the RAM file overflowed 5758 In the K Basic FSUM statement the specified file number is invalid the record buffer is not declared no declaration at FOPEN 5759 In the K Basic ONFERR statement an error exists in a component or BN dE 5760 In the K Basic EOF statement the specified file number is invalid the file number not opened is specified 5761 In the K Basic LOF statement the specified file number is invalid the file number not opened is specified 5762 In the K Basic SOF statement the specified file number is invalid the record buffer is not declared no declaration at FOPEN 3 20 CHAPTER3 ERRORS AT OIP OPE
72. sic FLUSH statement an invalid channel number is specified e a serial port that has not been opened is specified 5513 In the K Basic WRITESIO statement e an invalid channel number is specified other than a character string type array variable is specified an array variable subscript is invalid aserial port that has not been opened in the text mode is specified 5514 In the K Basic WRITESIOB statement an invalid channel number is specified other than a character string type array variable is specified an array variable subscript is invalid an invalid receive text length is specified e a serial port that has not been opened in the binary mode is specified 5515 In the K Basic IOCTL2 statement an invalid I O number is specified an invalid PLC device ID is specified 5550 In the K Basic SETDATE statement invalid date year month day is specified Write error occurs in a clock device 5551 In the K Basic GETDATE statement an array variable subscript is invalid a Write error occurs in a clock device 3 14 CHAPTER3 ERRORS AT OIP OPERATION 3 6 Errors during Operation Program Execution Countermeasure Action 5552 In the K Basic SETTIME statement Check the screen or an invalid time hour minute second is specified operation program that a Write error occurs in a clock indicator caused the error and 5553 In the K Basic GETTIME statement an array variable subscript is invalid
73. statement causes an invalid specification of a port number 5651 The K Basic OUT statement causes an invalid specification of a port number 5663 The K Basic LEN statement causes an invalid specification of a NM recorded character string number 5664 In the K Basic INSTR statement the specified record character string number is invalid the specified start position is invalid 5665 In the K Basic INSTR statement the specified record character string number is invalid the specified start position is invalid 5666 In the K Basic LEFT statement the specified record character string number is invalid the specified number of characters is invalid 3 16 CHAPTER3 ERRORS AT OIP OPERATION 3 6 Errors during Operation Program Execution Countermeasure Action 5667 In the K Basic LEFT statement Check the screen or the specified record character string number is invalid operation program that the specified number of characters is invalid caused the error and 5668 In the K Basic RIGHTS statement Contech the specified record character string number is invalid the specified number of characters is invalid 5669 In the K Basic RIGHTS statement the specified record character string number is invalid the specified number of characters is invalid 5670 In the K Basic MID statement the specified record character string number is invalid the specified start position is invalid the specified number of charact
74. tart Screen Creator 5 E101 Reading the entry file ENTRY INI failed Cause The entry file ENTRY INI in the System folder is invalid You cannot read it Action Copy the ENTRY INI file to another folder for investigation and delete it Then reinstall Screen Creator 5 E102 Reading the project file failed Cause project file in the System folder is invalid You cannot read it Action Copy the project file to another folder for investigation and delete it Then select Create in the menu and create the file E103 panel entry is not performed Cause The panel model is not selected when a project is created Action Select a panel model to be used in the project menu property E104 Initializing the icon failed Cause The icon file ICON BMP in the System folder is invalid Action Copy all icon files to another folder Then reinstall copy them from the master disk E105 Contents in the project file are invalid Cause project file PRO in the System folder is invalid lt Action gt Copy the project file to another folder for investigation and delete it Then select Create in the menu and create the file E106 Contents in the project file are invalid Cause record file REG in the project folder is invalid Action Copy the record file to another folder for investigation and delete it Then select Record in the menu and record the
75. umber of function arguments cannot exceed 20 Cause The number of function arguments exceeds 20 Action Reduce the number of the arguments to be 20 or fewer EC064 EXIT FUNCTION can be declared only in a function block Cause EXIT FUNCTION is used in other than a function block Action Stop using EXIT FUNCTION 065 name declared as a function is used for a variable Cause A name declared as a function is used for a variable Action Change the variable or function name 066 The function name cannot be declared with this name Cause An error exists in the function name in the DECLARE declaration Action Specify the function name correctly EC067 A function with the same name exists in the library function Cause created function exists in the library Action Change the function name 2 9 2 2 Errors in Compilation EC068 lt Cause gt lt Action gt EC069 lt Cause gt lt Action gt 70 Cause Action ECO71 lt Cause gt lt Action gt ECO072 Cause Action ECO073 Cause Action ECO074 Cause Action ECO075 Cause Action EC076 Cause Action ECOTT Cause Action The same name subroutine or label exists The same name subroutine or label exists Do not duplicate a subroutine or label name A logical device name must
Download Pdf Manuals