NI 9481 Operating Instructions and Specifications
Contents
1. 4 electromechanical relay channels Relay pe nenda re e RENAR Single pole single throw SPST Power on output state Channels off National Instruments Corp 11 NI 9481 Operating Instructions and Specifications Switching capacity resistive load Switching voltage 60 VDC max 250 V max Switching current per channel One channel on 4 A max at 30 VDC 1 A max at 60 VDC 4 A max at 250 Vins All channels on 2 A max at 30 VDC 1 A max at 60 VDC 2 A max at 250 Nun Resistance per channel channel on 50 mQ Switching rate 1 operation per second Relay release time 5 ms max Relay operate time 10 ms max Relay bounce time s sssseeeeereeeeeee 3 ms Off state leakage s 10 LA max Life expectancy Mechanical no load 20 000 000 operations Electrical connecting to load 100 000 operations NI 9481 Operating Instructions and Specifications 12 ni com OR NEE 460 321 hours at 25 C Bellcore Issue 2 Method 1 Case 3 Limited Part Stress Method N Note Contact NI for Bellcore MTBF specifications at other temperatures or for MIL HDBK 217F specifications Power Requirements Power consumption from chassis Active mode ssssssss 580 mW max Sleep mode sse 5 mW max Thermal dissipation at 70 C Active mode seninim 1 5 W max
2. Figure 2 NI 9481 Terminal Assignments National Instruments Corp 7 NI 9481 Operating Instructions and Specifications Each electromechanical relay channel has two interchangeable terminals CHa and CHb Each channel has an LED that indicates the state of the channel When a channel LED is lit the channel is on When the LED is dark the channel is off The LEDs are disabled when the chassis is in sleep mode Refer to the Sleep Mode section for more information about sleep mode When connecting a load to the NI 9481 connect the positive lead of the load to either the CHa or the CHb terminal and the ground of the load to one of the leads of the power supply Connect the remaining CHa or CHb terminal to the other lead of the power supply Figure 3 shows a possible configuration EE CHa i J Y lr i i gt p L 6 1 Load E CHb AC Ll Figure 3 Connecting a Load to the NI 9481 NI 9481 Operating Instructions and Specifications 8 ni com Note You must use 2 wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9481 When the channel is turned on the terminal connected to the load drives current or applies voltage to the load When the channel is off the terminal does not drive current or apply voltage to the load Wiring for High Vibration Applications If an application is subject to high vibration
3. Sleep mode eere 5 mW max National Instruments Corp 13 NI 9481 Operating Instructions and Specifications Physical Characteristics If you need to clean the module wipe it with a dry towel Screw terminal wiring 12 to 24 AWG copper conductor wire with 10 mm 0 39 in of insulation stripped from the end Torque for screw terminals 0 5 to0 6N m 4 4 to 5 3 Ib in 0 25 mm to 2 5 mm 150 g 5 3 oz Safety Safety Voltages Connect only voltages that are within the following limits CHa to CHb esee 250 Vims max Measurement Category II Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system This category refers to local level electrical distribution such as NI 9481 Operating Instructions and Specifications 14 ni com that provided by a standard wall outlet for example 115 V for U S or 230 V for Europe Caution Do not connect the NI 9481 to signals or use for measurements within Measurement Categories ITI or IV Isolation Channel to channel Contnuous ssesseeseeeeeeeeeee 250 Vms Withstand 1 400 V ms verified by a 5 s dielectric withstand test Channel to earth ground COontinuous 250 Vims Withstand AA 2 300 V ms verified by a5 s dielectric withstand test Hazardous Locations US UL veces sise Class I Division 2 Groups A
4. B C D T4 Class I Zone 2 AEx nC IIC T4 National Instruments Corp 15 NI 9481 Operating Instructions and Specifications Safety Standards This product meets the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use e EC 61010 1 EN 61010 1 e UL61010 1 CSA 61010 1 N Note For UL and other safety certifications refer to the product label or the Online Product Certification section Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 IEC 61326 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions e FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions NI 9481 Operating Instructions and Specifications 16 ni com Note For the standards applied to assess the EMC of this N product refer to the Online Product Certification section NI Note For EMC compliance operate this device with shielded cabling CE Compliance C lt This product meets the essential requirements of applicable European Directives as follows e 2006 95 EC Low Voltage Directive safety e 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory
5. National Instruments recommends that you either use ferrules to terminate wires to the detachable screw terminal connector or use the NI 9932 backshell kit to protect the connections Refer to Figure 4 for an illustration of using ferrules Refer to Figure 1 for an illustration of the NI 9932 connector backshell National Instruments Corp 9 NI 9481 Operating Instructions and Specifications T d p g SSSESE Figure 4 10 Terminal Detachable Screw Terminal Connector with Ferrule Sleep Mode This module supports a low power sleep mode Support for sleep mode at the system level depends on the chassis that the module is plugged into Refer to the chassis manual for information about support for sleep mode If the chassis supports sleep mode refer to the software help for information about enabling sleep mode Visit ni com info and enter cseriesdoc for information about C Series documentation NI 9481 Operating Instructions and Specifications 10 ni com Typically when a system is in sleep mode you cannot communicate with the modules In sleep mode the system consumes minimal power and may dissipate less heat than it does in normal mode Refer to the Specifications section for more information about power consumption and thermal dissipation Specifications The following specifications are typical for the range 40 to 70 C unless otherwise noted Output Characteristics Number of channels
6. OPERATING INSTRUCTIONS AND SPECIFICATIONS 4 Channel SPST Electromechanical Relay Module Fran ais Deutsch ZE SO fP ni com manuals Ww NATIONAL y INSTRUMENTS This document describes how to use the National Instruments 9481 and includes specifications and terminal assignments for the NI 9481 Visit ni com info and enter rdsoftwareversion to determine which software you need for the modules you are using For information about installing configuring and programming the system refer to the system documentation Visit ni com info and enter cseriesdoc for information about C Series documentation N Note The safety guidelines and specifications in this document are specific to the NI 9481 The other components in the system might not meet the same safety ratings and specifications Refer to the documentation for each component in the system to determine the safety ratings and specifications for the entire system Visit ni com info and enter cseriesdoc for information about C Series documentation NI 9481 Operating Instructions and Specifications 2 ni com Safety Guidelines Operate the NI 9481 only as described in these operating instructions Hot Surface This icon denotes that the component may be hot Touching this component may result in bodily injury Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the module take the following precautions A hazardous volta
7. ation Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 662 457990 0 Belgium 32 0 2 757 0020 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 21 5050 9800 Czech Republic 420 224 235 774 Denmark 45 45 76 26 00 Finland 358 0 9 725 72511 France 01 57 66 24 24 Germany 49 89 7413130 India 91 80 41190000 Israel 972 3 6393737 Italy 39 02 41309277 Japan 0120 527196 National Instruments Corp 21 NI 9481 Operating Instructions and Specifications Korea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351 210 311 210 Russia 7 495 783 6851 Singapore 1800 226 5886 Slovenia 386 3 425 42 00 South Africa 27 O 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 2005151 Taiwan 886 02 2377 2222 Thailand 662 278 6777 Turkey 90 212 279 3031 United Kingdom 44 0 1635 523545 NI 9481 Operating Instruct
8. compliance information To obtain product certifications and the DoC for this product visit ni com certification search by module number or product line and click the appropriate link in the Certification column National Instruments Corp 17 NI 9481 Operating Instructions and Specifications Shock and Vibration To meet these specifications you must panel mount the system and either affix ferrules to the ends of the terminal wires or use the NI 9932 backshell kit to protect the connections Operating vibration sinusoidal IEC 60068 2 6 5 g 40 to 500 Hz 0 062 in double amplitude 10 to 40 Hz Environmental National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure Refer to the manual for the chassis you are using for more information about meeting these specifications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 to 70 C Storage temperature IEC 60068 2 1 IEC 60068 2 2 40 to 85 C Ingress protection IP 40 NI 9481 Operating Instructions and Specifications 18 ni com Operating humidity IEC 60068 2 56 esses 10 to 9096 RH noncondensing Storage humidity IEC 60068 2 56 esses 5 to 9596 RH noncondensing Maximum altitude 2 000 m Pollution Degree IEC 60664 Environmental Management Nl is committed to designing and manufacturin
9. g products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the NI and the Environment Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document National Instruments Corp 19 NI 9481 Operating Instructions and Specifications Waste Electrical and Electronic Equipment WEEE X EU Customers At the end of the life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers and National Instruments WEEE initiatives visit ni com environment weee Baar mis Riehl SEDE CHE ROHS RS E National Instruments A t HETE E SS T dd WR gap f REA dz da RoHS T National Instruments F El RoHS HX Ef L TEESE ni com environment rohs china Forinformation about China RoHS compliance go to ni com environment rohs china NI 9481 Operating Instructions and Specifications 20 ni com Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Applic
10. ge is a voltage greater than 42 4 Vy or 60 VDC to earth ground Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards Caution Do not mix hazardous voltage circuits and human accessible circuits on the same module Caution Make sure that devices and circuits connected to the module are properly insulated from human contact National Instruments Corp 3 NI 9481 Operating Instructions and Specifications Caution When module terminals are hazardous voltage A LIVE 242 4 V 4 60 VDC you must ensure that devices and circuits connected to the module are properly insulated from human contact You must use the NI 9932 connector backshell kit to ensure that the terminals are not accessible Figure 1 shows the NI 9932 connector backshell Figure 1 NI 9932 Connector Backshell NI 9481 Operating Instructions and Specifications 4 ni com Safety Guidelines for Hazardous Locations The NI 9481 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nC IIC T4 hazardous locations and nonhazardous locations only Follow these guidelines if you are installing the NI 9481 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhaza
11. ions and Specifications 22 ni com National Instruments NI ni com and LabVIEW are trademarks of National Instruments Corporation Refer to the Terms of Use section on ni com 1ega1 for more information about National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice atni com patents 2003 2008 National Instruments Corp All rights reserved 373507D 01 Sep08
12. rdous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Caution For Zone 2 applications install the system in an enclosure rated to at least IP 54 as defined by IEC 60529 and EN 60529 gt be P National Instruments Corp 5 NI 9481 Operating Instructions and Specifications Special Conditions for Marine Applications Some modules are Lloyd s Register LR Type Approved for marine applications To verify Lloyd s Register certification visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the module Caution To meet radio frequency emission requirements for marine applications use shielded cables and install the system in a metal enclosure Suppression ferrites must be installed on power supply inputs near power entries to modules and controllers Power supply and module cables must be separated on opposite sides of the enclosure and must enter and exit through opposing enclosure walls NI 9481 Operating Instructions and Specifications 6 ni com Connecting the NI 9481 The NI 9481 has a 10 terminal detachable screw terminal connector that provides connections for 4 electromechanical relay channels CH0a CHOb CHia CH1b CH2a CH2b CH3a CH3b NC NC Qe ool som 25omg
Download Pdf Manuals
Related Search
Related Contents
PaperCut MF - Lexmark Embedded Print Release Manual EasyLink+ Quick User Guide V3_Layout 1 iGo PS00134-2008 power supply unit Windmere E0006F Use & Care Manual Full Service Manual - Pennsylvania Scale Company LITTERATURE : NOUVEAUTES AVRIL 2012 r m m E Atari System Reference Manual Gefen Digital Audio Switcher User's Manual Copyright © All rights reserved.