Home
        Operating Instructions Overvoltage arresters
         Contents
1.   F    40      85   C   40      185   F   5      95      non condensing     IP 66    Instruments with approvals can have different technical data depending on the version     For that reason the associated approval documents of these instruments have to be carefully  noted  They are part of the delivery or can be downloaded under www vega com via  VEGA Tools   and  serial number search  as well as via  Downloads  and  Approvals      D Reference temperature 25   C  77   F         14    Overvoltage arresters    B63 48  B63 32    8220    L NJ ZLOEE    33012 EN 130228    VEGA                                              8 Supplement  8 2 Dimensions  76mm 250 mm   2 99    9 84         C  56 mm      2 21    Fig  5  Dimensions B63 48  B63 32  1 Thread M20 x 1 5 or   2 NPT  depending on order specification  Overvoltage arresters    B63 48  B63 32 15    Printing date     VEGA    All statements concerning scope of delivery  application  practical use and operat   ing conditions of the sensors and processing systems correspond to the information  available at the time of printing    Subject to change without prior notice       VEGA Grieshaber KG  Schiltach Germany 2013           33012 EN 130228    VEGA Grieshaber KG Phone  49 7836 50 0  Am Hohenstein 113 Fax  49 7836 50 201  77761 Schiltach E mail  info de vega com    Germany www vega com    
2.  Connect wire end green yellow to the internal ground terminal in  the sensor housing  connect external ground terminal to potential  equalisation    9  Pull out terminal block inside B63 48  B63 32 with pliers       Overvoltage arresters  B63 48  B63 32 9    5 Connecting to power supply    VEGA       10  Push signal cables and screen through the cable gland and con   nect according to chapter  Wiring plan  to the terminals   11  Check all cable connections  especially the ground connection  to  make sure they are tightened sufficiently   12  Insert terminal block into its position by using the pliers  A me   chanical coding ensures the correct position   13  Screw cable gland into the thread of B63 48  B63 32  tighten  compression nut  The seal ring must completely encircle the  cable       io Display                         Fig  2  Overvoltage protection B63 48  B63 32 after installation and connection    14  Screw the housing cover back on  The electrical connection is hence finished        10    Overvoltage arresters    B63 48  B63 32    8220    L NJ ZLOEE    33012 EN 130228    VEGA    5 Connecting to power supply       5 3 Wiring plan  Wiring plan                                                                                   Fig  3  Wiring plan  sensor side  example single chamber housing  1 Connection cables of B63 48  B63 32  wire assignment see chart                Terminals sensor    Wire colour Polarity       1    Red           2    Black           Ground termina
3.  the instrument directly on to a spe   cialised recycling company and do not use the municipal collecting  points  These may be used only for privately used products according  to the WEEE directive     Correct disposal avoids negative effects on humans and the environ   ment and ensures recycling of useful raw materials     Materials  see chapter  Technical data     If you have no way to dispose of the old instrument properly  please  contact us concerning return and disposal        Overvoltage arresters    B63 48  B63 32 13    8 Supplement       8 Supplement    8 1 Technical data  General data  Version    Housing material  Weight approx     Electrical characteristics     Leakage current at nominal voltage  Internal resistance   Nominal leakage current   Band width    Signal circuit   Nominal voltage Signal     B63 48     B63 32   Screw terminals for cable cross section    Sensor circuit  Number of wires  Wire cross section  Cable length    Ambient conditions   Ambient temperature   Storage and transport temperature  Moisture    Electrical protective measures    Protection in assembled and connected  state    Approvals    The device can be screwed into the sensor housing  instead of the cable gland    316Ti  175 g  0 385 Ibs      lt 10 pA   10    lt  10 kA  8 20 us   1 MHz    9   48V DC 4     20 mA HART  9    V DC  Profibus PA  Foundation Fieldbus   lt  1mm   AWG 18     two signal cables  one ground cable  1 5 mm   AWG 14   250 mm  9 843 in      40      85   C   40      185 
4. 1     Please help us fulfill this obligation by observing the environmental  instructions in this manual    e Chapter  Packaging  transport and storage    e Chapter  Disposal        Overvoltage arresters    B63 48  B63 32    3 Product description       Scope of delivery    Constituent parts    Application area    Functional principle    3 Product description    3 1 Configuration  The scope of delivery encompasses   e Overvoltage arrester B63 48  B63 32  e Documentation      this operating instructions manual      Ex specific safety instructions and  if necessary  further certifi   cates    The following illustration shows the structure of B63 48  B63 32        D    my                                                Fig  1  Structure of B63 48  B63 32  1 Terminals for the signal cable input  unprotected side     2 B63 48  B63 32  3 Signal cable output to the sensor  protected side     3 2 Principle of operation    The overvoltage arresters B63 48  B63 32 are completely enclosed in  a stainless steel housing  They can be used for VEGA level and pres   sure sensors in two wire technology     e Type B63 48 for 4     20 mA HART sensors  e Type B63 32 for Profibus PA and Foundation Fieldbus sensors    B63 48  B63 32 overvoltage arresters reduce any voltage surges that  may reach the signal cables to a harmless level  The devices contain  voltage limiting components as well as gas conductors for bleeding  off impulses of up to 10 kA to ground        Overvoltage arresters    B63 48  B
5. 63 32    8220   L N3 c LO   e    33012 EN 130228    VEGA    3 Product description       Packaging    Transport    Transport inspection    Storage    Storage and transport  temperature    3 3 Packaging  transport and storage    Your instrument was protected by packaging during transport  Its  capacity to handle normal loads during transport is assured by a test  following ISO 4180     The packaging of standard instruments consists of environment   friendly  recyclable cardboard  For special versions  PE foam or PE  foil is also used  Dispose of the packaging material via specialised  recycling companies     Transport must be carried out under consideration of the notes on the  transport packaging  Nonobservance of these instructions can cause  damage to the device     The delivery must be checked for completeness and possible transit  damage immediately at receipt  Ascertained transit damage or con   cealed defects must be appropriately dealt with     Up to the time of installation  the packages must be left closed and  stored according to the orientation and storage markings on the  outside     Unless otherwise indicated  the packages must be stored only under  the following conditions     e Not inthe open   Dry and dust free   Not exposed to corrosive media  Protected against solar radiation  Avoiding mechanical shock and vibration    Storage and transport temperature see chapter  Supplement    Technical data   Ambient conditions   e Relative humidity 20     85         Overv
6. Operating Instructions    Overvoltage arresters  B63 48  B63 32        li     Document ID  33012                     Contents  Contents  1 About this document  dA UNCON gested ts died veecveey esterase i 3  1 2 Tar Q6t QrOUD is setcsss csscctessess seaaccs vopeetstececevesvesssecazeceecssxszdazecs  s 3  1 3 Symbolism Used iirinn i iie 3  2 For your safety  2 1 Authorised personnel                c  ceeccceeeese cee asics tsini  22 gt   APPONI USE  onnen ceases cces diglesseadevecesssatcacseeeietieseedne   2 3 Warning about incorrect use     2 4 General safety iNStruCtionS              cccceceeeeeteeeteeseeeeteeeeees  2 5 Safety label on the instrument  2 6 CE conformity  2 7 Safety instructions for Ex areas   0 2    cece ceeteeeteeeteeeteeeeees 5  2 8 Environmental instructions             cccccceeceeeeeeeeeeeeeeeteeeeeeees 5  3 Product description  3 1 COMP QUIAtION     0  eee eee ec cece eee cee eect ceeceeeeeeaeeeeeeeeseeseeeees 6  3 2 Principle of Operation              ccccceceeeeceeecee eens eeeeeeeeeeeeaeeenaes 6  3 3 Packaging  transport and storage    7  4 Instructions for installation  5 Connecting to power supply  5 1 Preparing the CONNECTION  irinaren 9  5 2 Connection procedures    eccna nnn 9  5 3  Wiring  plattisiecaiescrie secre aa E 11  6 Maintenance and fault rectification  Gl  Maint nanee isec tvtscnidvr eavan iriaren 12  6 2   Rectily taultS ireira av wei aessttveesteav sete eek 12  6 3 INStrUMeNTE PAIN sscec ese sseceven seers aeesees tes seeyeosteiestarv
7. elephone costs will be charged     Depending on the reason for the fault and the measures taken  the  steps described in chapter  Set up  may have to be carried out again     6 3 Instrument repair  If a repair is necessary  please proceed as follows     You can download a return form  23 KB  from our Internet homepage  www vega com under   Downloads   Forms and certificates   Repair  form      By doing this you help us carry out the repair quickly and without hav   ing to call back for needed information     e Print and fill out one form per instrument   e Clean the instrument and pack it damage proof   e Attach the completed form and  if need be  also a safety data  sheet outside on the packaging   e Please ask the agency serving you for the address of your return  shipment  You can find the respective contact data on our website  www vega com under   Company   VEGA worldwide        12    Overvoltage arresters    B63 48  B63 32    8220    L NA c LO   e    33012 EN 130228    7 Dismounting       7 Dismounting    7 1 Dismounting steps    Take note of chapters  Mounting  and  Connecting to power supply   and carry out the listed steps in reverse order     7 2 Disposal    The instrument consists of materials which can be recycled by spe   cialised recycling companies  We use recyclable materials and have  designed the parts to be easily separable     WEEE directive 2002 96 EG   This instrument is not subject to the WEEE directive 2002 96 EG and  the respective national laws  Pass
8. esvernss 12  7 Dismounting  GA DISMMOUNTING SlODS  isins runea rans egisi SSES sees 13  TEA  DISPOSAl E T T A ins Reaiecttaesealoees 13  8 Supplement  81  Technical Catal  iiciin antaas aae 14  8 2 DIMENSIONS 0 0 0    eee eee eee ceetee tence eeeeeeeeeeneeeeeeeaeeeeeeeeeneeees 15  Editing status  2013 02 05  2 Overvoltage arresters    B63 48  B63 32    8220    L NJ ZLOEE    33012 EN 130228    1 About this document        gt  me    1 About this document    1 1 Function   This operating instructions manual provides all the information you  need for mounting  connection and setup as well as important instruc   tions for maintenance and fault rectification  Please read this informa   tion before putting the instrument into operation and keep this manual  accessible in the immediate vicinity of the device     1 2 Target group    This operating instructions manual is directed to trained specialist  personnel  The contents of this manual should be made available to  these personnel and put into practice by them     1 3 Symbolism used   Information  tip  note   This symbol indicates helpful additional information    Caution  If this warning is ignored  faults or malfunctions can result   Warning  If this warning is ignored  injury to persons and or serious  damage to the instrument can result    Danger  If this warning is ignored  serious injury to persons and or  destruction of the instrument can result     Ex applications   This symbol indicates special instructions for Ex applicat
9. g    The B63 48  B63 32 exhibit a voltage resistance of 0 5 kV for one  minute in the signal circuit with respect to the stainless steel housing   but not with respect to the green yellow cable in the sensor circuit   This must be taken into account for the electrical installation    Before starting setup make sure that the power supply corresponds to  the specifications on the type label    In hazardous areas you must take note of the respective regulations   conformity and type approval certificates of the sensors and power  supply units     5 2 Connection procedure   Proceed as follows    1  Unscrew housing cover of the sensor   2  Ifa display and adjustment module is present  remove it accord   ing to the operating instructions of the sensor   3  Unscrew the cable gland    4  Push the connection cables through the cable gland into the sen   sor    5  Screw B63 48  B63 32 into the opening of the cable gland ac   cording to the description under  Mounting instructions     6  Shorten the connection cables of B63 48  B63 32 to the suitable  length  strip off the wire ends approx  1 cm  0 4 in     Note    To ensure an effective overvoltage protection  the connection cables  should be as short as possible  Unnecessary cable should not be  wound up and placed inside the sensor housing  This could influence  the protective function of B63 48  B63 32     7  Connect wire ends red and black according to chapter  Wiring  plan  and operating instructions of the respective sensor    8 
10. ions   List   The dot set in front indicates a list with no implied sequence   Action   This arrow indicates a single action     Sequence  Numbers set in front indicate successive steps in a procedure     Battery disposal  This symbol indicates special information about the disposal of bat   teries and accumulators        Overvoltage arresters    B63 48  B63 32    2 For your safety    VEGA       2 For your safety    2 1 Authorised personnel    All operations described in this operating instructions manual must  be carried out only by trained specialist personnel authorised by the  plant operator     During work on and with the device the required personal protective  equipment must always be worn     2 2 Appropriate use    B63 48  B63 32 are overvoltage arresters in two wire technology for  installation in VEGA level and pressure sensors     You can find detailed information on the application range in chapter   Product description      2 3 Warning about incorrect use    Inappropriate or incorrect use of the instrument can give rise to  application specific hazards  e g  vessel overfill or damage to system  components through incorrect mounting or adjustment     2 4 General safety instructions    This is a high tech instrument requiring the strict observance of stand   ard regulations and guidelines  The user must take note of the safety  instructions in this operating instructions manual  the country specific  installation standards as well as all prevailing safety regulatio
11. l    Green yellow                OE       iii                            Fig  4  Wiring plan B63 48  B63 32 side    1 To the sensor  2 Signal circuit       Overvoltage arresters    B63 48  B63 32    11       6 Maintenance and fault rectification VEGA       Reaction when malfunc   tions occur    Fault rectification    24 hour service hotline    Reaction after fault recti   fication    6 Maintenance and fault rectification    6 1 Maintenance    If the instrument is used properly  no special maintenance is required  in normal operation     To ensure the function of B63 48  B63 32  we recommend a regular  visual check at intervals of max  1 year for     e secure mounting   e mechanical damage or corrosion   e worn or otherwise damaged cables   e correct and clearly marked cable connections    6 2 Rectify faults    The operator of the system is responsible for taking suitable meas   ures to rectify faults     The first measure to be taken is to check the input output signal as  well as the power supply  In many cases  the causes can be deter   mined and faults can be quickly rectified     On site repair of B63 48  B63 32 is not possible     Should these measures not be successful  please call in urgent cases  the VEGA service hotline under the phone no   49 1805 858550     The hotline is available to you 7 days a week round the clock  Since  we offer this service world wide  the support is only available in the  English language  The service is free of charge  only the standard  t
12. ns and  accident prevention rules     The instrument must only be operated in a technically flawless and  reliable condition  The operator is responsible for trouble free opera   tion of the instrument     During the entire duration of use  the user is obliged to determine the  compliance of the necessary occupational safety measures with the  current valid rules and regulations and also take note of new regula   tions     2 5 Safety label on the instrument    The safety approval markings and safety tips on the device must be  observed     2 6 CE conformity    This device fulfills the legal requirements of the applicable EC guide   lines  By attaching the CE mark  VEGA provides a confirmation of  successful testing  You can find the CE conformity declaration in the  download area of  www vega com         Overvoltage arresters    B63 48  B63 32    8220    L NA c LO   e    33012 EN 130228    2 For your safety       2 7 Safety instructions for Ex areas    Please note the Ex specific safety information for installation and op   eration in Ex areas  These safety instructions are part of the operating  instructions manual and come with the Ex approved instruments     2 8 Environmental instructions    Protection of the environment is one of our most important duties   That is why we have introduced an environment management system  with the goal of continuously improving company environmental pro   tection  The environment management system is certified according  to DIN EN ISO 1400
13. oltage arresters    B63 48  B63 32 7    4 Instructions for installation    VEGA       4 Instructions for installation    B63 48  B63 32 overvoltage arresters are screwed into the position  of the cable gland on the sensor housing  The cable gland of the  sensor is screwed into the overvoltage arrester  No further assembly  is necessary     Caution   B63 48  B63 32 overvoltage arresters must not be used in a corrosive  environment     The thread on the overvoltage arrester must correspond to the thread  on the sensor housing  In order to maintain the enclosure rating of the  sensor  PTFE gasket strip must be used  First of all  screw in by hand   if necessary  use grease and finally tighten with a   turn with a SW 27  wrench        Overvoltage arresters    B63 48  B63 32    8220    L NJ ZLOEE    33012 EN 130228    VEGA    5 Connecting to power supply       Note safety instructions    Take note of safety  instructions for Ex  applications    A    5 Connecting to power supply    5 1 Preparing the connection  Always keep in mind the following safety instructions   e Connect only in the complete absence of line voltage    Danger    The stainless steel housing of B63 48  B63 32 has no electrical  function and therefore provides no internal or external connection to  ground or potential equalization    The plant operator is responsible for ensuring an adequate connec   tion  for example within the context of protective grounding  depend   ing on the installation and protection ratin
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Samsung LN6B60 User's Manual  La réforme des ryThmes éducaTifs au Pré sainT  Origo Tig 150-200 LiftArc  Tachograph programmer CD400 User manual CD400 V2.0  CMB16D-QC DMX - Light-O-Rama  Chief LSM5124 flat panel wall mount  1214 Horti Parcs et jardins 24 sept 2013  Samsung 931BW Uporabniški priročnik  Dx550C User Manual    Copyright © All rights reserved. 