Home
DSW108D Smoke Alarm User's Manual
Contents
1. chirp sounds every about 30seconds it tells you to exchange your battery 4 Little smoke will not cause alarms so misinformation occurs only when you blow smoke to the alarms directly or you forget to turn on your ventilated facility while your cooking 5 Sometimes when you smoke the unit will alarm so you can just blow air to it to stop alarming REGULAR MAINTENANCE 1 Never use water cleaners or solvents to clean your smoke alarm since they may damage the unit 2 Test it at least once a week 3 Clean the smoke alarm at least once a month Gently vacuum off any dust using your household vacuum s soft brush attachment Open the cover and disconnect the battery gently vacuum the inside of the cover and the sensor chamber reconnect the battery close the smoke alarm and vacuum the outside of the cover test the smoke alarm 4 Use these batteries to replace the old one Carbon zinc EVEREADY 216 OR 2122 GOLDPEAK 1604P OR 1604S Alkaline EVEREADY 522 DURACELL MN1604 Ms1604 GOLDPEAK 1604A Lithium ULTRALIFE U9VL 5 When regularly checking you should save energy as possible as you can because the alarm energy consumption is very much Special attention 1 Choose durable battery as possible as you can that will make battery s using time longer 2 Notice whether the indicator lamp flash once 45sec normally or not There is two reasons that the indicator lamp don t flash One is that the battery s energy is sho
2. DSWIO8BD Smoke Alarm User s Manual DSW108D are photoelectric smoke alarms they are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches of bedding DSW108D accords with the ISO DIS 12239 Standard IMPORTANT PLEASE READ CAREFULLY AND KEEP IT This user s manual contains important information about your smoke alarm s operation To insure your safety you need install one alarm at least in your every single room Please don t open the smoke alarm for that may cause improper effect TECHNICAL PARAMETER Related Power DC9V AC110V AC220V Static Current lt 10uA Alarm Current lt 10mA Alarm Sonority lt 85dB 3m Low Voltage Alarm 6 5V 0 5V Working Temperature 10 C 50 C WHERE TO INSTALL SMOKE ALARMS 1 At first you need install them in your bedroom and routeway and should install one item in every bedroom at least 2 Stairway is important for you to rush out when fires occur so there must install smoke detectors 3 You at least require one smoke alarm on every floor including finished attics and basements 4 Install one alarm beside every electric facility 5 Install smoke alarms in the middle of ceiling because smog heat and flashes always lift to the top of rooms 6 If some reasons cause you can t install them in the middle of ceiling you need to install th
3. eiling or wall and make a mark at the center of each of the mounting slots with a pencil 3 Place the unit where it won t get covered with dust when you drill the mounting holes 4 Using a 6 5mm drill bit drill a hole through each pencil mark into 35mm deep 5 Insert the plastic screw anchors into the holes and tap them gently with a hammer Tighten the 3 30 screws into the screw anchors then loosen them two turns 6 Slide the smoke alarm base up to the screw heads end up in the narrow ends of the mounting slots then tighten the screws completely 7 Insert the 9V battery into the the box make sure the red pry is under the battery so the battery is stable Diagram 3 DIAGRAM 3 8 Ensure to insert battery before you install the alarm or you will destroy the unit 9 Close the cover with the alarm according to Diagram 4 and then finish your installation TEST It is important to test this unit weekly to make sure it is working properly Don t open the alarms by yourself return them to the seller if improperly and don t use fire to test your alarms 1 Press and hold the test button on the cover of the unit until the alarm sounds If it does not alarm make sure that the unit is receiving power and test it again If it still does no1 alarm replace it immediately or check your battery 2 The signal flashes once 30 seconds and while it alarms the signal will flash once 0 5 second 3 If the alarm makes low
4. em at least 10cm away from the wall 7 lf you like to install them on the wall they should be installed 10 30 5cm away under the ceiling Diagram 1 8 You need install more than one alarm when the length of your hall exceeds 9m 9 In an ablique roof room install the alarm 0 9m away from the top Diagram 2 10 How to install smoke alarms in a removable house The removable house is short of heat isolation so you d better install the alarm 10 30 5cm away from the ceiling for safety you need install another one near your bedroom too 10cm 4 MINIMUM Pa K A ANYWGERE IN THIS AREA oee Tma a Taman DIAGRAM 1 HORIZONTAL DISTANCE FROM PEAK DIAGRAM 2 SIDE WALL Za WHERE NOT TO INSTALL SMOKE ALARMS 1 Where combustion particles are produced Combustion particles form when something burns Avoid installing in the areas include poorly ventilated kitchens garages and furnace rooms Keep units at least 6m from the sources of combustion particles stove furnace water heater space heater if possible Ventilate these areas as much as possible 2 In air streams near kitchens Air currents can draw cooking smoke into the sensing chamber of a smoke alarm near the kitchen 3 In very damp humid or steamy areas or directly near bathrooms whith showers Keep units at least 3m away from showers saunas dishwhashers etc 4 Where the temperatures are regularly below 40 F 4 C or above 100F 38 C incl
5. rtage the other is that the battery is not fixed fitly The simple way is to replace the battery or refix the battery 6 After installation you must notice whether the key indicator flash once 45sec or not and press the key for several seconds to see whether the buzzer can give sound or not if do that shows normal Above is required to do otherwise the smoke alarm you installed probably don t work LIMITATIONS OF SMOKE ALARMS 1 United States NFPA72 tells that the safety of life is to be noticed by alarms before fire to confirm the correct escape way The fire systems help half of residents escape and we should help the old people women and children more because they are always the victims 2 Smoke alarms are not foolproof they can t prevent or extinguish fires they are not substitute for property or life insurance You need buy some fire fighting facilities 3 Sometimes the smoke is blocked by objects and can t reach the detector and if the wind blows the smoke away from the detector the unit won t work either HOW TO DO IN CASE OF FIRE 1 Call the Fire Department immediately after confirming the fire 2 Don t panic stay calmly and follow your family escape plan Get out of the house as quickly as possible don t stop to get dressed or collect anything 3 Feel doors before opening them to see if they are hot If a door is cool open it slowly Don t open a hot door use an alternate escape route 4 Cover yo
6. uding unheated buildings outdoor rooms porches or unfinished attics or basements 5 In very dusty dirty or greasy areas Don t install a smoke alarm directly over the stove or range Clean a laundry room unit frequently to keep it free of dust or lint 6 Near fresh air vents ceiling fans or in very drafty areas Drafts can blow smoke away from the unit preventing it from reaching the sensing chamber 7 In insect infested areas Insects can clog openings to the sensing chamber and cause unwanted alarms 8 Less than 305ram away from fluorescent lights Electrical noise can interfere with the sensor 9 In dead air space for example in Diagram 1 near the corner less than 10cm 10 If you have a smoking meeting room don t install the alarm there for the unit will alarm when several persons smoke HOW TO INSTALL THIS SMOKE ALARM SINGLE FLOOR PLAN o v o o MULTIPLE FLOOR PLAI O T ma BEDROOM BEDROOM O e O BEDROOM BEDROOM BEDROOM 9 o LIVING ROOM LIVING ROOM BEDROOM o 2 2X KITCHEN SMOKE ALARM FOR MINIMUM PROTECTION Z e Mha BASEWENT O SMOKE ALARM FOR ADDITIONAL PROTECTION Tools you will need Pencil Drill with 6 5ram drill bit Standard Flathead screwdrive Hammerr 1 Hold base firmly and push the hinge in then turn anti clockwise so release the base down 2 Hold the smoke alarm base against the c
7. ur nose and mouth with a cloth preferably wet Take short shallow breath 5 Meet at your planned place outside your home and do a head count to ensure everybody go out safely
Download Pdf Manuals
Related Search
Related Contents
Minolta DiMAGE Z6 User Guide Manual pdf MAPS DBL: A14247-003 - Medtronic Manuals: Region DOWNLOAD PDF Fisher-Price C5792 User's Manual UnityMol – SweetUnityMol User Manual (Version Nov Sämonitor minidrill - wtk Pelco HS8013 User's Manual Copyright © All rights reserved.
Failed to retrieve file