Home
INFRARED MOTION SENSOR DPS28F USER'S MANUAL
Contents
1. eS Install procession before installing switch off power press the lock button of bottom cover with finger and pull off the top cover like 1 connect power the load with sensor according to connection wire method Install the sensor body on selected position with screw and dilatants like 2 make top cover aim at the body and button the cover like 3 install finish If you want to open the top cover you should press the lock button on both side with screwdriver and simultaneously pull off the top over like 4 lo dk button lackb utto ri E a im press ceiling press pre press push J pull off pull off 3 4 Install attention in sense range there should not be obstruction you should not install the unit facing window and where temperature change quickly like air conditioning stove to avoid false working in front of sense window there should not be moving object like hanging fan etc troubleshooting load doesn t work v check whether the connection of power and load is correct or not x check whether the load is good or not x check whether the working light you set accord with ambient light or not Sensitivity is low x Check whether in front of sense window there is isolation to affect sensor receiving signal x Check whether ambient temperature is too high x Check whether sense signal source is in sense range O Sensor can not shut off load automatically
2. 4 Like above you can repeat pressing button to make the adding and diminishing exchange until the number is needed Note 1 to avoid false pressing 2sec later after pressing and hold set time button it start to set time 2 After switch off power the time you set previously will not be saved it will resume default time normal mode 8sec impulse mode 50sec 3 during setting time to make number adding and diminishing exchange the interval between loosing button and pressing it again should not exceed 2sec otherwise the LED numeric will display OFF you must reset time from 0 Example set time 25sec and then set to 10sec Step1 after sensor enter working state press and hold set time button until LED numeric display 29 loosen button the number adding LED numeric display 000 001 009 019 029 Step2 within 2sec immediately press and hold button again until LED numeric display 25sec loosen button the number diminishing LED numeric display 029 028 025 LED numeric display OFF and setting finish LUX and SENS adjustment 1 use flat head screwdriver to turn the knob note to avoiding destroy the knob you should turn it lightly but not overexert 2 SENS adjustment by turning the SENS knob to adjust the detecting distance turn clockwise to increase sensitivity and counterclockwise turn to decrease it 30 LUX adjustment turn clockwise to increase working light and when turn to the end the unit can wor
3. INFRARED MOTION SENSOR DPS28F USER S MANUAL SUMMARY DPS28F has 3 high sensitivity detectors it adopts IC LED numeric display and SMT technology the 3 detectors compose wide detecting range it use infrared energy form human body as its control source when one enter its sense range it can start controlled load for example lamp after leaving the range the load will go out automatically within set time DPS28F has remote controller the controller can remote control the DPS28F 30m away from controller We can add new function for you and produce it according to your requirement Hope our product will take you convenience SPECIFICATION Power source 100V AC 130V AC Sense angle 360 220V AC 240V AC Remote control distance 30m wide place Power frequency 50 60Hz Working temperature 20 C 40 C power source emitter DC12V Relative humidity lt 93 RH emit frequency 433MHz Install height 1 5m 3 5m Light control lt 83LUX gt 1000 LUX adjustable Power consumption Working 0 45W static 0 1W Sense distance 4m 10m adjustable Sense motion speed 0 6 1 5m s Rated load 1200W 220V AC 240V AC 800W 100V AC 130V ACI Time delay normal mode Osec 999sec adjustable default 8sec Sense time interval impulse mode Osec 999sec adjustable default 50sec FUNCTION 1 accurate LED numeric display time delay function it can be accurate to sec 1sec 999sec for your choice operation simple and using conveni
4. ent 2 impulse mode is another new function when one enters its sense LED HUME RIC OG FLET range it will start load to turn on 0 5sec that give effect of alert signal in this mode the sense time interval is adjustable default is 50sec SET TIME button used to set time the details is in SET TIME WAY switch convert NORMAL mode and IMPULSE mode SENSE LED sensitivity SENS is adjustable Ye a e light control LUX is adjustable 2 remote controls are for your choice at will remote controller 1 or remote controller 2 on the load work always off 1 make the load stop working 2 in normal mode after convert to impulse mode press it to return normal mode impulse in normal mode press this key to convert to impulse mode Set time set needed time the details isin SET TIME me controllen 1 WAY Note 1 during sensing the emitter is ineffective 2 loosen the off key after 2sec pressing other key is effective SET TIME WAY In normal mode set time delay and in impulse mode set sense time interval 1 50sec later after switching on power the sensor enter working state now you can start to set time 2 Press and hold set time button LED numeric display number start to add from the right bit like following figure 3 Loose set time button and then within 2sec immediately press and hold button again LED numeric display number start to diminish from the right bit like following figure
5. k all day and all night counterclockwise turn to decrease it when turn to the end it only can work in the circumstance lt 3LUX you can turn the knob to other position according to your required working light Max sense distance 1m ENS Normal mode LED numeric display OFF Sense the load work for some time time delay is adjustable default is 8sec 1 slide switch to normal mode and the unit be in normal mode turn light control LUX knob to max and sensitivity knob SENS to certain position Switch on power the load doesn t work and LED numeric display reversing 50 00 when LED numeric display OFF the sensor enter working state 4 moving in the sensing range the LED numeric display moving to left that indicate the sense signal is detected 5 after receiving sense signal the sense LED lights and the load works keep human body hold still absolutely under no continual sensing condition the LED numeric display reversing time delay example default 8sec and it display reversing like 008 000 until the LED numeric display OFF the load stops working 6 like that sense once the load works for 8sec you can set other time delay Note after sense it for the first it receive sense signal again the time delay will recompute time from the second sense so when human body always move in the sense range the load will work always 7 using remote controller press on key make the load work always
6. press off key 1 make the load stop working 2 after convert to impulse mode press the key to return normal mode press impulse key convert to impulse mode note after switching off the unit return normal mode press Set time key set needed time delay the details is in SET TIME WAY Impulse mode LED numeric display OFF moving to left Sense the load work for 0 5sec the sense time interval is adjustable default is 50sec 1 Slide switch to impulse mode the unit be in impulse mode turn light control LUX Knob to max and sensitivity knob SENS to certain position Switch on power the load doesn t work and LED numeric display reversing 50 00 when LED numeric display OFF moving to left the sensor enter working state 4 moving in the sensing range after receiving sense signal the sense LED lights and the load works for 0 5sec then the LED numeric display compute reversing time interval example default 50sec and it display reversing like 050 00 when the LED numeric resume displaying OFF moving to left and you can sense again 5 like that sense once every at least 50sec you can set other time interval the load works for 0 5sec 6 using remote controller press on key make the load work always press off key make the load stop working press Set time key set needed sense time interval the details is in SET TIME WAY connection wire method CUHK ECTIOHW COLL rH output sensor a
7. x Check whether there is continual sensing signal in sense range or not v Whether power accord with specification required or not x Whether temperature near sensor changes quickly for example air conditioning heater etc
Download Pdf Manuals
Related Search
Related Contents
Graco 3A1211L User's Manual prensa de columna gato invertido “eg01514 VisualDMX Manual the error code list Fisher & Paykel OB30 User's Manual LEADPlus 2014 Tutorial and User Manual 3.Making UCon_Lin Interface the UConnect board USER MANUAL Masque nasal Mirage Kidsta™ Copyright © All rights reserved.
Failed to retrieve file