Home

USB Control Module Software Utilities User Guide

image

Contents

1. Search for Suitable Driver and click Software Utilities Install NEXT 1 On the Internet go to http www americandynamics net softDownloads home asp Install Hardware Device Drivers Fates 2 Click on the USB Control Module icon 4 device driver is a software program that enables a hardware device to work with SY an operating system 3 Click on the USB Control Module Software Utility icon 4 Download ADACSNET _ Utility X_XX zip file This wizard will complete the installation for this device oy USB Device 4 device driver is a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the Rene hee 5 Unzip this file to a temporary folder on the What do you want the wizard to do W nd OWS d es kto p Search for a suitable driver for my device tecommended C Display alist of the known drivers for this device so that can choose a specific 6 n th e te m po rary fo id er do u b e cl ick th e Setup exe file To Se 7 Follow Install Wizard prompts 8 Once installation completes delete the temporary file from the desktop USB CONTROL MODULE SOFTWARE UTILITIES 8200 0310 02 REV A USER GUIDE 2 of 6 Using Utilities Software This section describes how to e Use the software Load Utility to upload firmware updates to a dome camera or a USB module e Use the software to monitor and display
2. AMERICAN DYNAMICS USB Control Module Software Utilities User Guide Contents About the Software c ccccceccececcececcecececcececeecess 1 Software REQUIFEMENTS cccccceeeeeeeeeeeeeeeseeeeees 1 Software Installation c ccccceceececccececcececceceees 2 USB Driver Install c ccccccccececcececcececeececeeees 2 Software Utilities Install 2 Using Utilities Software cceeeeeeeeeeeeeeeeeees 3 Uploading New Firmware ccccsssseceeeeseeeeees 3 sensorNet Analyzer Dome Control 2004 Sensormatic USB CONTROL MODULE SOFTWARE UTILITIES USER GUIDE 1 of 6 About the Software The USB Control Module Software Utilities is service application software installed on a personal computer that enables e Firmware updates be uploaded to a dome camera or USB Control Module e SensorNet activity to be analyzed e Control of a dome camera from a personal computer via the USB Control Module Software Requirements USB Module and Cable Supplied PC Laptop hardware PC system with USB port Operating system Microsoft Windows 2000 or XP 8200 0310 02 REV A 8 Check Specify Location and click NEXT Software Installation E j j j j j Locate Driver Files This section describes how to install Service Where do you want Windows to search for driver files eS application software Search for driver files for the following hardware dev
3. 6147 6168 Lc Module 2 SDO 1 2843 6116 SDO 1 2843 6189 5 SDU 5 2507 6368 Load Snet Device File Load Progress Scan Complete Select Devices From List J Upload latest Rev The interface will display a file selection list box as shown below Select the appropriate file to be loaded to the dome and click LOAD SNET DEVICE Load progress is indicated in the File Load Progress window To return to the scan display click on any address with valid dome data in the SensorNet Devices window Flash Loader Rey 1 01 i x SensorNet Devices ae FO147 0107 hex a Addr Type Flash Rev 7 Snet F2507 0308 hex 1 SDU 0147 6108 C Module F2507 0309 hex 2 SDO 1 2843 9110 usb_app_020304 hex usb_app012904 hex v Load Snet Device 4 Device Add File Load Progress 3 SDO 1 2843 6169 5 SDU 5 2567 6368 Select load file from list V Upload latest Rev USB CONTROL MODULE SOFTWARE UTILITIES USER GUIDE Uploading to the USB Control Module To upload new code to the USB Control Module do the following 1 On the Internet go to http www americandynamics net softDownloads home asp 2 Click on the USB Control Module icon 3 Click on USB Control Module Firmware 4 Download the ADACSNET_Firmware_X_XX zip file to a temporary file on the Windows desktop 5 Unzip the ADACSNET_Firmware_X_XX zip file to C Program Files ADUtiI
4. After starting this application wait one minute before clicking this button or when an address higher than 16 is set for the first time to allow the USB Module to finish scanning the network for online domes Click to transmit a data packet to the dome s ping socket The dome returns the data and a comparison is made by the software application to determine if this data is the same as that transmitted The user display window indicates the transmitted packets Tx and how many received packets Rx are good To stop the ping test click STOP PING Alarm The state each alarm input is in is indicated by ALARM LEDS 1 3 A green led indicates the alarm is on a red led indicates the alarm is off Dome Menu Control Functions Click MENU to command the dome to enter the monitor s on screen menu mode as well as change the numeric keypad to the Menu Control View arrows To select the desired function click UP DOWN LEFT or RIGHT arrows to highlight the desired function then click SELECT Use the TOGGLE key to change the value of the function Click MENU to return to the Control View PEE American Dynamics Dome Control O Cameal Peel ie Flip Repeat Oo View Menu eal Pattern itm TE Auto IRIS QuickSet Close a Focus Zoom Start Fing 8200 0310 02 REV A
5. SensorNet activity e Use the software to control a dome camera On the desktop click START Programs and ADUtilisX_XX The USB Module Utility Panel appears 15 x 10 23 47 AM w USB Module Utility Panel 1 2 19 2004 sensorNet Analyzer Dome Control Get Info The Utility Panel displays buttons for three USB module utilities Load Utility SensorNet Analyzer and Dome Control Note The time and date are also displayed A Get Info button provides version information for each utility the USB module and the SnetUSB dll file The three buttons do the following Load Utility Use to upload new firmware code to either a dome camera or USB Module SensorNet Analyzer Use to monitor a SensorNet Network and to display the communication protocol and timing between a controller and any SensorNet device Dome Control Use to program and control a SensorNet dome camera USB CONTROL MODULE SOFTWARE UTILITIES USER GUIDE 3 of 6 Uploading New Firmware Use the Load Utility button to upload new code to the dome camera default or USB Control Module Note The Load Utility requires dome or module firmware be placed in the C Program Files ADUtilsX_XX folder Uploading to a Dome Camera 1 On the Internet go to http www americandynamics net softDownloads home asp Click on the SpeedDome icon Click on the appropriate dome firmware update Download the zip file to a
6. input of the dome camera Then on the USB Module Utility Panel click DOME CONTROL to display the Dome Control window i Dome Control Yer 1 01 ioj x American Dynamics Dome Control Camera 1 Peel Repeat Menu Reset ey Fad IRIS QuickSet a Zoom Focus NEAR m j e Flash Rev oe Functions in this window are as follows Select Dome Camera To enter the dome camera address click the numeric 0 9 keys and then SET The display indicates the currently selected camera To erase an incorrect number click CLR before SET Pan and Tilt Click and drag the black dot at the center of the joystick in the direction the dome is to go The farther the drag the faster the dome goes Release the mouse button to release the dot and stop the dome 8200 0310 02 REV A Zoom Out In Click OUT or IN to change the dome s field of view FOV Focus Far Near Click FAR or NEAR to manually focus the dome Iris Close Open Click CLOSE or OPEN to manually adjust the iris level of the dome Auto Click to return iris and focus functions to automatic View also known as Target Preset To go toa stored VIEW use the numeric keypad to enter the view number and click VIEW To store a view click SET enter the number and click VIEW Pattern also known as Tour To run a stored pattern enter the pattern number 1 3 using the numeric keypad and click PATTERN To repeat a pattern conti
7. temporary folder on the Windows desktop Extract the zip file to the C Program Files ADUtiIX_XX folder Delete the temporary file from the desktop On the USB Module Utility Panel press LOAD UTILITY The Flash Loader panel appears ensure Snet is selected w Flash Loader Rey 1 01 SensorNet Devices Upload Addr Type Flash Rev Snet C Module 1 SDU 6147 2 SDO 1 2843 3 SDO 1 2843 5 SDU 5 2507 Maz Snet Address 5 SGan Netiicik Load Snet Device File Load Progress Scan Complete Select Devices From List V Upload latest Rev Enter the maximum SensorNet address in the MAX SNET ADDRESS window Click SCAN NETWORK The SensorNet Devices window will list the address type and revision of each dome on the network 10 Click one or more domes to be updated Select domes in sequence using Shift click or domes not in sequence using Ctrl click Click LOAD SNET DEVICE to start the upload If the message file not found appears and an error is reported begin again at Step 1 11 8200 0310 02 REV A 12 13 Loading progress is indicated in the File Load Progress window If multiple domes were selected each dome loads in sequence Note If a dome does not respond with usable data as shown below for a device at address 4 double click the device address to be loaded x SensorNet Devices m Upload Addr Type Flash Rev Snet 1 SDU 7
8. E or the change from the previous packet DELTA e Start SensorNet Monitor On Off Click button turns green to display SensorNet packet activity To stop monitoring click STOP SENSORNET MONITOR button turns red If datalogging is enabled the datalog file is added to the Datalogging Files window list e Pause On Off Click button turns red to pause monitoring Click again to continue monitoring button turns green e Clear Display Click to clear the main display window e Data Logging On Off Click ON to store sensorNet data packets to a file The utility automatically generates a datalogging file name and displays it in the File Name window The file name contains the date time and has a mon extension Double clicking within the File Name USB CONTROL MODULE SOFTWARE UTILITIES USER GUIDE window highlights the file name and allows a file name to be created using the keyboard The mon extension is automatically added e Data Logging Files This window lists currently stored datalogging files Clicking a file name in this window enables the Analyze function e Analyze On Off When ON the utility displays the selected datalogging file in the main display window instead of current network activity Select OFF to turn off this function e Delete File Click file name in the Data Logging Files window Click DELETE FILE to delete Dome Control Connect the USB Control Module to the SensorNet
9. X_XxX 6 When finished delete the temporary file from the desktop 7 On the USB Module Utility Panel click LOAD UTILITY The Flash Loader panel appears i Flash Loader Rev 1 04 x Upload 61 dwn AD Utilities exe AD Utilities POM AD Utilities TT AD Utilities vbp 7 z Refresh Load USB Module File Load Progress Select Load File 8 Click REFRESH to display current files in the file selection window 9 In the Upload box click MODULE 10 Click LOAD USB MODULE to start the upload process Load progress is indicated in the File Load Progress window 11 To complete the firmware update power cycle the USB Control Module by temporarily disconnecting the USB connection 8200 0310 02 REV A 4 of 6 SensorNet Analyzer The SensorNet Analyzer is used to monitor SensorNet activity To use the analyzer 1 Connect SensorNet terminals of the USB module to the SensorNet network to be monitored 2 On the USB Module Utility Panel click SENSORNET ANALYZER The SensorNet Monitor Utility window appears Sensor Nel Hionibor i Time Sec He Dain inp goa a eae ae 1 hi ni iasi pp 7 This SensorNet Monitor Utility window displays SensorNet activity Packet information is displayed with a time stamp and function description Functions that appear in this window are as follows e Time Enables the time stamp to display time from the start of monitoring ABSOLUT
10. ice USB Driver Install a The wizard searches for suitable drivers in its driver database on your computer and in any of the following optional search locations that you specify O n th e nte rn et g O to To start the search click Next IF you are searching on a floppy disk or CD ROM drive i insert the floppy disk or CD before clicking Next http www americandynamics net softDownloads home asp Optional search locations 1 Click on the USB Control Module icon CD ROM dives IV Specify a location 2 Click on USB Control Module Drivers T Microsoft Windows Update 3 Select and download the Cancel ADACSNET_Drivers zip file 4 Unzip the ADACSNET_Drivers zip file to a 9 Click BROWSE and enter the path to the temporary folder on the Windows desktop temporary folder created in Step 4 5 Connect the USB module to a PC using the x supplied USB A B cable Windows should Insert the manufacturer s installation disk into the drive OK indicate that new USB hardware was found and J selected and then click OK will launch the Found New Hardware Wizard Cancel Welcome to the Found New Hardware Wizard This wierd helps pou natal a device diver for a hardwore device Copy manufacturer s files from D 10 Follow wizard prompts to finish USB driver installation 11 Once USB driver install completes delete the temporary folder from the desktop 6 Click NEXT 7 Check
11. nuously click REPEAT enter the pattern number 1 3 using the numeric keypad and click PATTERN To define a pattern click SET enter the pattern number 1 3 using the numeric keypad and click PATTERN Pan tilt and zoom the dome until the pattern has run To end the pattern click PATTERN To review the pattern just defined click PATTERN If the pattern is acceptable click SET and then PATTERN to replace the pattern designated at the beginning of the definition sequence Peel Click to have the dome perform the Apple Peel pattern Initiate any PTZ function to cancel this pattern Reset Double click to reset the dome camera Flip Click to move the pan axis of the dome camera 180 QuickSet Click to have the dome display the Quickset menu To begin any Quickset function enter the number on the video display and then click QUICKSET To clear the menu click QUICKSET again If you Know the number enter it before clicking QUICKSET to bypass the dome Quickset menu Vphase To adjust the selected dome s video phase Vphase click VPHASE or VPHASE USB CONTROL MODULE SOFTWARE UTILITIES USER GUIDE Flash Rev After starting this application wait one minute before clicking this button to allow the USB Module to finish scanning the network for online domes Click to display the dome flash revision level This information is displayed on the user display at the top of the application screen Start Ping